How to Prime Your Pump
More
How to Determine Feet of Head
More
About Process Pumps
More
About Drum Pumps
More
Smooth-Flow Drum Pumps for Water and Chemicals
Rotate the handle to dispense a continuous flow of liquid. A corrosion-resistant polypropylene housing allows these pumps to be used with detergents, cleaning fluids, and antifreeze.
Temp. Range, °F | Intake | Discharge (Spout End) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | For Hose ID | Hose Connection Type | Spout Type | Each | |
8 | 15-55 | 319 | Not Rated | 100° | 2 NPT | Drum Connector | 1 1/4" | 44 1/2" | 1" | Barbed | Removable | 00000000 | 0000000 |
8 | 15-55 | 704 | Not Rated | 180° | 2 NPT | Drum Connector | 1 5/8" | 40 1/4" | __ | __ | __ | 00000000 | 000000 |
Smooth-Flow Drum Pumps for Oil
Rotate the handle to dispense a continuous flow of liquid.
Removable spouts can be replaced with discharge tube for transfer applications.
Style C pumps dispense exactly one quart of liquid with each rotation of the handle.
Repair kits include components such as gaskets, pistons, and piston valves.
Temp. Range, °F | Intake | Discharge (Spout End) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Pipe Size | Thread Type | Spout Type | Each | |
11 | 55 | 420 | Not Rated | 300° | 2 NPT | Drum Connector | 1/2" | 40" | 3/4 | NPT | Removable | 000000 | 0000000 |
Optional Crank-Locking Device with Handle for Pump with Removable Spout | 0000000 | Each | 000000 |
Optional 3/4 NPT × 2 NPT Drum Connector for Pump with Removable Spout | 0000000 | Each | 00000 |
Optional Crank-Locking Device with Label, Locking Pin, and Nut for Pump with Removable Spout | 000000 | Each | 000000 |
Replacement Pump Head for Pump with Removable Spout | 000000 | Each | 000000 |
Repair Kit for Pump with Removable Spout | 0000000 | Each | 000000 |
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Hose OD | Hose Lg., ft. | Drum Pump Type | Spout Type | Each | |
11 | 55 | 420 | Not Rated | 300° | 2 NPT | Drum Connector | 1/2" | 40" | 5/8" | 8 | Crank Handle | Removable | 000000 | 0000000 |
Optional Crank-Locking Device with Handle | 0000000 | Each | 000000 |
Repair Kit | 0000000 | Each | 000000 |
Optional 3/4 NPT × 2 NPT Drum Connector | 0000000 | Each | 00000 |
Replacement Nozzle | 0000000 | Each | 00000 |
Optional Crank-Locking Device with Label, Locking Pin, and Nut | 000000 | Each | 000000 |
Replacement Hose | 0000000 | Each | 000000 |
Replacement Pump Head | 000000 | Each | 000000 |
Temp. Range, °F | Intake | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Discharge Location | For Discharge Tube ID | Drum Pump Type | Each | |
32 | 15-55 | 350 | 40° | 120° | 2 NPT | Drum Connector | 1" | 18"-36" | Spout End | 3/4" | Crank Handle | 0000000 | 0000000 |
Smooth-Flow Drum Pumps for Fuel
Rotate the handle to dispense a continuous flow of liquid. These pumps are rated for use with Class I and II flammable and combustible fuels.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Pumps with removable spout allow you to replace the spout with a 1" ID discharge tube for transfer applications.
Temp. Range, °F | Intake | Discharge (Spout End) | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Pipe Size | Thread Type | Gender | Features | Each | |
11 | 55 | 420 | Not Rated | 300° | 2 NPT | Drum Connector | 3/4" | 22"-40" | 3/4 | NPT | Male | Drip Pan, Internal Flame Arrester, Strainer | 0000000 | 0000000 |
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Hose OD | Hose Lg., ft. | Features | Each | |
11 | 55 | 420 | Not Rated | 300° | 2 NPT | Drum Connector | 3/4" | 22"-40" | 3/4" | 8 | Internal Flame Arrester, Nozzle Hanger, Strainer, Vacuum Breaker | 0000000 | 0000000 |
Electric Drum Pumps with Nozzle for Fuel
Pump fuel in hazardous environments with flammable gases. Pumps are UL listed for Class I, Divisions 1 and 2, Group D.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Style A pumps have a circuit breaker to prevent overload. Pumps with automatic shut-off nozzle turn off when the tank is full.
Style B pumps have a metering nozzle that registers total volume up to 99,999.9 gallons. Lock with a padlock (not included). A bypass valve prevents pressure buildup when the nozzle is closed.
Anti-siphon kit prevents reverse flow with a vacuum breaker and includes all hose, fittings, and seals required for installation. Pedestal kit converts your pump from a drum mount to a pedestal mount.
Temp. Range, °F | Intake | Discharge | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | For Drum Opening Size | Tube OD | Tube Lg. | Hose ID | Hose Lg., ft. | Hose OD | Nozzle Type | Electrical Connection Type | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
12 | 15 | 10 | -20° | 125 | 1/8 hp | 1.5 | 4.8 | 2 NPT | 1 7/16" | 22"-40" | 3/4" | 12 | 1 5/32" | Automatic Shut-Off | Hardwire | 0000000 | 0000000 |
Temp. Range, °F | Intake | Discharge | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max.Lift, ft. | For Drum Opening Size | Gender | Pipe Size | Thread Type | Hose ID | Hose Lg., ft. | Hose OD | Nozzle Type | Max. Shackle Dia. | Electrical Connection Type | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
20 | 22 | 10 | -40° | 150 | 1/3 hp | 5.5 | 10 | 2 NPT | Female | 1 1/4 | NPT | 3/4" | 12 | 1 1/8" | Lockable, Manual Shut-Off, Metering | 3/8" | Hardwire | 0000000 | 000000000 |
Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals
Alter the flow rate for versatile dispensing. These pumps do not include a drum connector.
Pumps | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Intake | Discharge | Repair Parts | |||||||||||||||
Flow Rate, gpm | Discharge Pressure, psi | For Container Size, gal. | Min. | Max. | Horsepower | Current, A | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Electrical Connection Type | Each | |||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
A | 0-18.5 | 9 | 30 | 15° | 120° | 1/4 hp | 1.5 | 32 mm | Wall Bracket | 1 1/4" | 27" | 3/4" | 1" | 60" | Plug | 00000000 | 0000000 | 00000000 |
A | 0-18.5 | 9 | 55 | 15° | 120° | 1/4 hp | 1.5 | 32 mm | Wall Bracket | 1 1/4" | 39" | 3/4" | 1" | 60" | Plug | 00000000 | 000000 | 00000000 |
Hazardous Location High-Flow Battery-Operated Drum Pumps with Nozzle for Fuel
These pumps are C-UL listed for Class I, Division 2, Group D for use in environments with flammable gases. Operating on a 12-volt battery, use them to transfer and drain fuel such as gasoline, diesel fuel, and kerosene. Lock the nozzle with a padlock (not included).
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Pumps with automatic shut-off nozzle turn off when the tank is full.
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | ID | Lg., ft. | Nozzle Type | Max. Shackle Dia. | Thermal Protection | Each | |
12V DC | |||||||||||||||||||
25 | 20 | 10 | -20° | 125° | 4/10 hp | 35 | 15 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1 | Female | NPT | 1" | 18 | Automatic Shut-Off, Lockable | 5/16" | With Thermal Overload Protection | 0000000 | 000000000 |
25 | 20 | 10 | -20° | 125° | 4/10 hp | 35 | 15 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1 | Female | NPT | 1" | 18 | Manual Shut-Off, Lockable | 5/16" | With Thermal Overload Protection | 0000000 | 000000 |
High-Pressure Constant-Flow-Rate Pumps
Commonly called rotary vane pumps, these are designed to pump water at high pressures in low-flow applications. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. They have a built-in bypass relief valve to prevent pressure buildup. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Intake | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Pressure, psi | Max. Viscosity | Temp. Range, °F | hp | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Lg. | Wd. | Ht. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
0.8 | 240 | Not Rated | 30° to 195° | 1/4 | 5 | 3/8 | NPT | Female | 3/8 | NPT | Female | 12" | 6" | 6" | 00000000 | 0000000 |
120/240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
1.8 | 240 | Not Rated | 30° to 195° | 1/3 | 5.6/2.8 | 3/8 | NPT | Female | 3/8 | NPT | Female | 12" | 6" | 6" | 00000000 | 000000 |
2.3 | 240 | Not Rated | 30° to 195° | 1/2 | 7.2/3.6 | 3/8 | NPT | Female | 3/8 | NPT | Female | 12" | 6" | 6" | 00000000 | 000000 |
High-Pressure Constant-Flow-Rate Pumps without Motor for Water
Commonly called rotary vane pumps, they have a built-in bypass relief valve to prevent pressure buildup. Attach an electric motor with a speed reducer or a belt pulley to alter the pump speed. Use a NEMA 56C frame motor. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids. They meet NSF/ANSI 61 safety standards for use with drinking water systems.
Pumps with a 303 stainless steel housing are more corrosion resistant than pumps with a brass housing.
Intake (NPT) | Discharge (NPT) | Overall | Shaft | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity | For Motor Power Source | Required hp | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Lg. | Wd. | Dp. | Center-to-Base Lg. | Each | |
Brass Housing | ||||||||||||||||||
0.8 | 554 | 240 | Not Rated | Electric | 1/4 | 3/8 | Female | 3/8 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 0000000 |
1.8 | 554 | 240 | Not Rated | Electric | 1/3 | 3/8 | Female | 3/8 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
2.3 | 554 | 240 | Not Rated | Electric | 1/2 | 3/8 | Female | 3/8 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
4.3 | 554 | 240 | Not Rated | Electric | 3/4 | 1/2 | Female | 1/2 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
5.4 | 554 | 240 | Not Rated | Electric | 1 | 1/2 | Female | 1/2 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
303 Stainless Steel Housing | ||||||||||||||||||
2.3 | 554 | 240 | Not Rated | Electric | 1/2 | 3/8 | Female | 3/8 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
4.3 | 554 | 240 | Not Rated | Electric | 3/4 | 1/2 | Female | 1/2 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
5.4 | 554 | 240 | Not Rated | Electric | 1 | 1/2 | Female | 1/2 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
Maintenance Kits for Air-Powered Transfer Pumps
Replace worn or broken parts on your transfer pump. Match your pump’s manufacturer and model number to select the right kit.
Smooth-Operating Hydraulic Pumps
For technical drawings and 3-D models, click on a part number.
Inlet Connection— NPT | Outlet Connection— NPT | Overall | Shaft | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SAE Trade Size | Fixed Displacement Rate, cu. in./rev. | Max. Flow Rate, gpm | Max. Pressure, psi | Max. Speed, rpm | Pipe Size | Dash Size | Pipe Size | Dash Size | Ht. | Lg. | Dia. | Lg. | Mounting Hole Ctr-to-Ctr | Drive Direction | Each | |
Opposite Side Ports | ||||||||||||||||
A | 0.6 | 4.6 | 1,500 | 1,800 | 1 | 16 | 1/2 | 08 | 4 13/16" | 6 5/16" | 3/4" | 1 7/16" | 4 3/16" | Clockwise | 0000000 | 000000000 |
A | 1.19 | 9.2 | 1,500 | 1,800 | 1 | 16 | 1/2 | 08 | 4 13/16" | 6 3/4" | 3/4" | 1 7/16" | 4 3/16" | Clockwise | 0000000 | 00000000 |