Filter by
Test End Component
Measures
Display Type
For Fluke Model Number
Electrical Safety Rating
Manufacturer Model Number
Test End Type
Certification
DFARS Specialty Metals
Electrical Resistance Meters
![]() |
Check that floors, garments, and other work surfaces won’t discharge static electricity. These laboratory-grade meters are made in the U.S. and certified to NIST standards for accuracy and reliability. They’re essential in server rooms, clean rooms, and other environments where static could harm sensitive electronics. Also known as surface resistance meters, they’re fully compliant with ANSI for testing and validating workplace static control systems.
To prevent static discharge, surface resistance needs to be less than 1×109 ohms. Our meters measure resistance as high as 1×1012 ohms, with the results clearly displayed on a crisp OLED screen. Readings are exact to two places, with no rounding to the nearest exponent like with less sophisticated meters.
Each meter comes with leads and two 5 lb. probes. Place one probe on a surface to measure the resistance to the ground (Rtg), or place both on a surface to measure the point-to-point resistance between them (Rtt).
Small Parts Probe—Use the small parts probe (sold separately) to measure resistance on small items or in hard-to-access areas, such as server racks or semiconductor assembly lines.
Packaging Probe—Use the packaging probe (sold separately) to measure the resistance of thin packaging and films.
Batteries | |||||||||
---|---|---|---|---|---|---|---|---|---|
Resistance | Accuracy | Features | Includes | Included | Size | No. Required | Each | ||
1× 10^3 Ω to 1× 10^12 Ω | -10% to 10% | Battery Life Indicator, Data Memory | 1 Alligator Clip, 1 Carrying Case, 1 Ground Plug Adapter, 2 Probe Spacers (10" Lg. and 36" Lg.), 2 Test Leads, 2 Test Probes | Yes | AA | 4 | 000000 | 000000000 |
Fluke Test Lead Sets
![]() | ![]() |
Model Number FTPL-1 | Model Number TL175 |
![]() | ![]() |
Model Number TL222 | Model Number TL224 |
![]() | ![]() |
Model Number TL26A | Model Number TL27 |
![]() | ![]() |
Model Number TL28A | Model Number TL40 |
![]() | ![]() |
Model Number TL71 | Model Number TL75 |
![]() | ![]() |
Model Number TL76 | Model Number TL910 |
Connect to Fluke multimeters with a set of red and black test leads.
The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Mfr. Model No. | For Fluke Model No. | Test End | Connection End | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | Certification | No. of Cords | Cord Lg. | Color | Test End Material | Pair | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FTPL-1 | 289 | Notched Threaded Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Nickel-Plated Brass | 00000000 | 0000000 | |
TL175 | 77IV, 113, 114, 115, 116, 117, 175, 177, 179, 233, 287, 289 | Notched Threaded Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Nickel-Plated Brass | 00000000 | 00000 | |
TL222 | 83V, 87V, 787 | Sheathed Banana Plug | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT III, 1,000V; CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 60" | Black, Red | Copper | 00000000 | 00000 | |
TL224 | 87V, 107, 179, 233, 287, 3000 | Sheathed Banana Plug | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT III, 1,000V; CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 60" | Black, Red | Copper | 00000000 | 00000 | |
TL26A | 83V, 87V, 88V/A, 107, 179, 287, 289 | Serrated Alligator Clip | Sheathed Standard Banana Plug | 30 | 30 | 8 | — | CSA Certified, CSA-US Certified | 2 | 60" | Black, Red | Nickel-Plated Copper | 00000000 | 00000 | |
TL27 | 107, 175, 177, 179, 787 | Sheathed Banana Plug | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT III, 1,000V | CSA Certified, CSA-US Certified | 2 | 60" | Black, Red | Copper | 00000000 | 00000 | |
TL28A | 88V/A, 107, 175, 177, 179, 287, 289 | Serrated Alligator Clip | Sheathed Standard Banana Plug | 30 | 30 | 10 | CAT I, 30V | CSA Certified, CSA-US Certified | 2 | 60" | Black, Red | Copper | 00000000 | 00000 | |
TL40 | 83V, 87V, 88V/A, 287, 289, 787 | Retractable Probe Tip | Sheathed Standard Banana Plug | 600 | 600 | 3 | CAT II, 600V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Stainless Steel | 00000000 | 00000 | |
TL71 | 27 II, 28 II, 83V, 87V, 88V, 114, 115, 116, 117, 175, 177, 179, 233, 787, 789 | Notched Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Nickel-Plated Brass | 00000000 | 00000 | |
TL75 | 83V, 87V, 113, 175, 177, 179, 287, 289, 787, 789 | Notched Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Nickel-Plated Brass | 00000000 | 00000 | |
TL76 | 87V, 107, 179, 287, 289, 787 | Pointed Threaded Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT II, 1,000V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Nickel-Plated Brass | 00000000 | 00000 | |
TL910 | 83V, 87V, 287, 289, 787 | Pointed Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 3 | CAT II, 1,000V | CSA Certified, CSA-US Certified | 2 | 40" | Black, Red | Gold-Plated Copper | 00000000 | 00000 |
Fluke Test Lead Kits
![]() |
These kits include a set of red and black Fluke test leads with a variety of interchangeable tips.
The connection end on the test leads is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Mfr. Model No. | For Fluke Model No. | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | Includes | Cord Lg. | Color | Each | ||
---|---|---|---|---|---|---|---|---|---|---|---|
TL220 | 27 II, 28 II, 83V, 87V, 114, 115, 116, 117, 123, 175, 177, 179, 233, 287, 289, 373, 374, 787, 789 | 1,000 | 1,000 | 10 | CAT II, 1,000V | Two Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug Two Needle Tips Two Insulated Plunger Style Alligator Clips | 59" | Black, Red | 0000000 | 0000000 | |
TLK-225 | 27 II, 28 II, 83V, 87V, 175, 177, 179, 287, 289, 787, 789, 1577, 1587 | 1,000 | 1,000 | 1 | CAT IV, 600V | Two Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug Two Needle Tips Two Insulated Alligator Clips Two Retractable Grabbers Two Retractable Precision Grabbers Two Retractable Precision Hooks Pouch | 59" | Black, Red | 0000000 | 000000 | |
TLK289 | 287, 289, 376, 381 | 1,000 | 1,000 | 3 | CAT II, 1,000V | Two Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug Two Needle Tips Two Insulated Alligator Clips Two Retractable Grabbers Two Retractable Precision Hooks Thermocouple Magnetic Hanger Pouch | 59" | Black, Red | 0000000 | 000000 |
Magnetic Fluke Multimeter Hangers
![]() | ![]() |
Free up your hands while using your Fluke multimeter by suspending it from this hanger.
Mfr. Model No. | For Fluke Model No. | Each | ||
---|---|---|---|---|
TPAK | 77IV, 83V, 87V, 88V, 113, 114, 115, 116, 117, 175, 177, 179, 233, 287, 289, 789, 1577, 1587 | 0000000 | 000000 |
Fluke Multimeter Cases
![]() | ![]() | ![]() | ![]() | ![]() |
Fabric Case | Hard Case | Leather Case | Tool Bag | Fabric Holster |
Mfr. Model No. | Case Type | Performance | For Fluke Model No. | Each | ||
---|---|---|---|---|---|---|
C25 | Fabric Case | — | 83V, 87V, 88V, 175, 177, 179, 787, 789, 1577, 1587 | 0000000 | 000000 | |
C35 | Fabric Case | — | 83V, 87V, 113, 233 | 0000000 | 00000 | |
C101 | Hard Case | — | 27 II, 28 II, 83V, 87V, 287, 1577, 1587, T5-600, T5-1000 | 0000000 | 000000 | |
C116 | Fabric Case | — | 233, 287, 289 | 0000000 | 00000 | |
C520A | Leather Case | — | T5-600, T5-1000 | 0000000 | 00000 | |
C550 | Tool Bag | — | 27 II, 28 II, 77IV, 83V, 87V, 114, 115, 116, 117, 175, 177, 179, 233, 287, 289, 324, 355, 373, 374, 376, 381, 787, 789, 1577, 1587, 3000 FC, T5-600, T5-1000 | 0000000 | 000000 | |
CXT170 | Hard Case | Weatherproof | 114, 115, 116, 117, 175, 177, 179, 787, 1577, 1587 | 0000000 | 000000 | |
CXT80 | Hard Case | Weatherproof | 287, 289 | 0000000 | 000000 | |
H5 | Fabric Holster | — | T5-600, T5-1000 | 0000000 | 00000 |
Fluke Instrumentation Process Control Multimeters
![]() |
With these combination loop calibrators and multimeters, check for current control loop issues in PLCs, motors, and fans in addition to taking other electrical measurements. When used as a loop calibrator, the current input as well as the percentage of the input scale is shown on the dual display, giving you quick diagnostic information. Fluke is known for quality and durability.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters | Multimeters with Calibration Certificate | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Max. DC Current, amp | Hardware Features | Display Count | Includes | Each | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
787B | CAT III, 1,000V | AC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 0.1% | 0.44 | 0.44 | Lead Storage, Overload Protection | 4,000 | Alligator Clips, Test Leads | 0000000 | 000000000 | 0000000 | 000000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
789 | CAT IV, 600V | AC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 0.1% | 0.44 | 0.44 | Overload Protection | 4,000 | Alligator Clips, Test Leads | 000000 | 00000000 | 00000000 | 00000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Data-Logging Multimeters
![]() |
Record measurements from electrical tests over time to identify intermittent issues such as voltage spikes and temporary power flow problems. Review data captured by these high-quality and durable Fluke multimeters in real-time or save it for future analysis.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Software—To download and analyze data on a computer, software is required (not included). Connect your multimeter to a computer with the included USB cord.
Multimeters | Multimeters with Calibration Certificate | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Data Log Cap. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Max. DC Current, amp | Hardware Features | Display Count | Includes | Each | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
287 | 10,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 0000000 | 0000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
289 | 15,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Impedance, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 000000 | 0000000 | 00000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Water-Resistant Multimeters
![]() |
For taking electrical measurements in washdown environments, choose the durability and quality of Fluke multimeters with an IP67-rated housing.
Average-Sensing AC Calculation—Average-sensing multimeters take accurate AC measurements when testing equipment that has a linear load and draws current in a smooth sine wave, such as standard induction motors.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Max. DC Current, amp | Hardware Features | Display Count | Includes | Enclosure Rating | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Average-Sensing AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
27 II | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 0.1% | 10 | 10 | Overload Protection | 6,000 | Alligator Clips, Test Leads | IP67 | 000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Clamp-on-Jaw Multimeters
![]() |
Jaws surround a cable to test current without interrupting the circuit, making these high-quality, durable Fluke multimeters especially useful for testing high current. They include test leads to perform other electrical tests.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters | Test Leads | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Multimeters | Multimeters with Calibration Certificate | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Mfr. Model No. | Jaw Opening | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Max. DC Current, amp | Display Count | Includes | Each | Each | Pair | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
325 | 1.18" | CAT III, 600V; CAT IV, 300V | AC Current, AC Voltage, Capacitance, DC Voltage, Resistance, Temperature | 600 | 600 | 1% | 400 | — | 6,000 | Carrying Case, Temperature Probe, Test Leads | 00000000 | 0000000 | 00000000 | 0000000 | 00000000 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
355 | 2.3" | CAT IV, 600V | AC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance | 600 | 1,000 | 1% | 2,000 | 2,000 | 10,000 | Alligator Clips, Carrying Case, Test Leads, Test Probes | 00000000 | 00000000 | ——— | 0 | ——— | 0 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Open-Jaw Multimeters
![]() |
Run a cable through the open jaw to test current without interrupting the circuit. These multimeters are especially useful for high current measurements and include test leads to perform other electrical tests. Fluke multimeters are known for quality and durability.
Average-Sensing AC Calculation—Average-sensing multimeters take accurate AC measurements when testing equipment that has a linear load and draws current in a smooth sine wave, such as standard induction motors.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Jaw Opening | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Display Count | Includes | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Average-Sensing AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
T5-600 | 0.5" | CAT III, 600V | AC Current, AC Voltage, DC Voltage, Resistance | 600 | 600 | 1% | 100 | 1,000 | Test Leads | 0000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
T5-1000 | 0.5" | CAT IV, 600V | AC Current, AC Voltage, DC Voltage, Resistance | 1,000 | 1,000 | 1% | 100 | 1,000 | Test Leads | 0000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Test Lead Tips
![]() |
Adapt Fluke test leads to perform electrical tests in tight spaces. Attach these tips to test leads that have 4 mm banana plugs.
Test End | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | For Fluke Model No. | Test End Component | Connection End | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | Color | Material | Insulation Material | Pair | ||
TP1 | 83V, 87V, 175, 177, 179, 373, 374, 376, 381, 787, 789, T+PRO, T5-1000, T5-600 | Needle Tip | Standard Banana Jack | 1,000 | 1,000 | 10 | CAT II, 1,000V | Black, Red | Stainless Steel | Polypropylene | 0000000 | 000000 |
Fluke Test Lead Sensors
![]() | ![]() |
Model Number 80BK-A | Model Number 80TK |
Take temperature readings with a Fluke multimeter.
Model Number 80BK-A—Fluke 80BK-A is a temperature probe and works with Fluke multimeters that measure temperature. It has 4 mm standard banana jack connection ends that attach to Fluke test leads that have 4 mm banana plugs.
Model Number 80TK—Fluke 80TK is a thermocouple converter that adapts a Fluke multimeter without a temperature function to a thermometer using the included temperature probe. It has 4 mm standard banana plug connection ends that attach to 4 mm banana jacks on Fluke multimeters.
Mfr. Model No. | For Fluke Model No. | Temp. Range, ° F | AC Voltage, V AC | DC Voltage, V DC | Test End Component | Connection End | Cord Lg. | Test End Insulation Material | Each | ||
---|---|---|---|---|---|---|---|---|---|---|---|
80BK-A | 28 II, 87V, 116, 179, 233, 287, 289 | -40 to 500 | — | — | Needle Tip | Sheathed Standard Banana Jack | 39" | PTFE | 0000000 | 000000 | |
80TK | 27 II, 28 II, 114, 115, 116, 117, 123, 175, 177, 179, 233, 287, 289, 789 | -40 to 500 | 24 | 60 | Needle Tip | Sheathed Standard Banana Plug | 39" | PTFE | 0000000 | 000000 |