About Motor Switches and Starters
More
Spade-Terminal Relays
![](/prerenderstable/mvPRE/contents/gfx/imagecache/767/7678k62c1-d01c-digital-master1559749159-p9@halfx_636953279683269310.png?ver=imagenotfound)
Using a low-current signal, these relays are often used to control small motors and heaters. These relays attach to quick-disconnect terminals.
Surface-mount relays have a slot on the flange for mounting them to flat surfaces.
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Maximum Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | |
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Surface Mount | ||||||||||
4 | 24V AC | 71 | 30 A @ 240 V AC | 250V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 000000 |
4 | 120V AC | 20 | 30 A @ 240 V AC | 250V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
4 | 240V AC | 10 | 30 A @ 240 V AC | 250V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
DIN-Rail Mount Solid State Relays
![](/prerenderstable/mvPRE/contents/gfx/imagecache/745/7456k78c1-d01c-digital-master1551467805-p9@halfx_636661989618903172.png?ver=imagenotfound)
Unlike mechanical relays, these solid state relays have no moving parts, so they require less maintenance and last longer, switch faster, and are quieter. They mount on 35 mm DIN rail (also known as DIN 3) for fast installation. An LED indicator lights up when these relays are connected, so you can quickly confirm that they’re wired correctly. IP20 rated, their terminals are recessed, so they prevent fingers and other objects from touching live circuits.
Relays with an integrated heat sink disperse heat to increase the relay’s current rating.
For technical drawings and 3-D models, click on a part number.
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage (Load Type) | Max. Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Features | Each | |
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Single Phase | |||||||||||
4 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC, 24V DC, 48V DC, 60V DC, 120V DC | 13 | 30 A @ 230 V AC (Full Load) | 264V AC | 3/4 hp @ 115 V AC 2 hp @ 230 V AC | 4.33" | 0.89" | 4.917" | Integrated Heat Sink, LED Indicator | 0000000 | 0000000 |
4 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC, 24V DC, 48V DC, 60V DC, 120V DC | 22 | 30 A @ 600 V AC (Full Load) | 660V AC | 3/4 hp @ 115 V AC 2 hp @ 230 V AC | 4.33" | 0.89" | 4.917" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
4 | 3V DC, 6V DC, 12V DC, 24V DC, 30V DC | 11 | 30 A @ 230 V AC (Full Load) | 264V AC | 3/4 hp @ 115 V AC 2 hp @ 230.000 V AC | 4.33" | 0.89" | 4.917" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
4 | 4V DC, 6V DC, 12V DC, 24V DC, 30V DC | 13 | 30 A @ 600 V AC (Full Load) | 660V AC | 3/4 hp @ 115 V AC 2 hp @ 230 V AC | 4.33" | 0.89" | 4.917" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
3 Circuits Controlled with 3 Off (Normally Open)—3PST-NO | |||||||||||
Three Phase | |||||||||||
8 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC, 24V DC, 48V DC, 60V DC, 120V DC | 2 | 30 A @ 600 V AC (Full Load) | 660V AC | 5 hp @ 230 V AC 10 hp @ 480 V AC | 4.33" | 2.84" | 4.66" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
8 | 5V DC, 6V DC, 12V DC, 24V DC, 30V DC | 10 | 30 A @ 600 V AC (Full Load) | 660V AC | 5 hp @ 230 V AC 10 hp @ 480 V AC | 4.33" | 2.84" | 4.66" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
Open-Style Screw Terminal Relays
![](/prerenderstable/mvPRE/contents/gfx/imagecache/738/7384k11c1-d01c-digital-master1551467804-p9@halfx_636661386085202843.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/738/7384k41c1-d01c-digital-master1551467804-p9@halfx_636661423542446952.png?ver=imagenotfound)
Use these relays with industrial automation systems, security and emergency lighting, and small motors. They’re also known as power relays. Hardwire them to your circuit using the screw terminals.
Optional covers protect contacts from dust and dirt.
Relays | Optional Covers | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | ||||||||||||
4 | 24V AC | 395 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 000000 | 0000000 | 000000 |
4 | 120V AC | 79 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
4 | 240V AC | 40 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
4 | 12V DC | 167 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
4 | 24V DC | 83 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||
5 | 24V AC | 395 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
5 | 120V AC | 79 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
5 | 240V AC | 40 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
5 | 12V DC | 167 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
5 | 24V DC | 83 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | ||||||||||||
6 | 24V AC | 395 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
6 | 120V AC | 79 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
6 | 240V AC | 40 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
6 | 12V DC | 167 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
6 | 24V DC | 83 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||
8 | 24V AC | 395 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3.3" | 2.5" | 2.4" | 0000000 | 00000 | 0000000 | 00000 |
8 | 120V AC | 79 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3.3" | 2.5" | 2.4" | 0000000 | 00000 | 0000000 | 00000 |
8 | 240V AC | 40 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3.3" | 2.5" | 2.4" | 0000000 | 00000 | 0000000 | 00000 |
8 | 12V DC | 167 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3.3" | 2.5" | 2.4" | 0000000 | 00000 | 0000000 | 00000 |
8 | 24V DC | 83 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3.3" | 2.5" | 2.4" | 0000000 | 00000 | 0000000 | 00000 |
Infrequent-Cycle Relays
![](/prerenderstable/mvPRE/contents/gfx/imagecache/656/6564k851c1-d01c-digital-master1559317090-p9@halfx_636949173465042724.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/656/6564k744c1-d01c-digital-master1551467803-p9@halfx_636588559877948124.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/656/6564k952c1-d01c-digital-master1551467803-p9@halfx_636588577693220522.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/656/6564k101c1-d01c-digital-master1551467803-p9@halfx_636588537707567892.png?ver=imagenotfound)
For use with equipment that cycles on and off, these relays meet UL 508 for air conditioning and heating. Connections are accessible from the front, so you can mount relays side-by-side. Also known as definite-purpose contactors.
Enclosures (sold separately) are NEMA 1 rated to protect contacts from corrosion.
Also Available: Auxiliary contacts for 3.8"-7.2" Ht. relays. They allow you to add a signaling device or control another relay. Please select 6564K99, then select the McMaster-Carr part number of your relay and whether you want to switch one circuit on (1 Normally Open) or off (1 Normally Closed).
For technical drawings and 3-D models, click on a part number.
Switching Current @ 600V AC | hp @ Switching Voltage | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Power | Full Load | Resistive Load | Single Phase | Three Phase | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | |
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | ||||||||||||
With Quick-Disconnect and Screw Terminals | ||||||||||||
2 | 24V AC | 6VA | 25A | 30A | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 000000 |
2 | 24V AC | 6VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
2 | 120V AC | 6VA | 25A | 30A | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
2 | 120V AC | 6VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
2 | 208V AC, 240V AC | 6VA | 25A | 30A | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
2 | 208V AC, 240V AC | 6VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | ||||||||||||
With Quick-Disconnect and Screw Terminals | ||||||||||||
4 | 24V AC | 6.5VA | 20A | 30A | 1 1/2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
4 | 24V AC | 6.5VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
4 | 120V AC | 6.5VA | 20A | 30A | 1 1/2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
4 | 120V AC | 6.5VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
4 | 24V DC | 3.1W | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | __ | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
4 | 208V AC, 240V AC | 6.5VA | 20A | 30A | 1 1/2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
4 | 208V AC, 240V AC | 6.5VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
3 Circuits Controlled with 3 Off (Normally Open)—3PST-NO | ||||||||||||
With Quick-Disconnect and Screw Terminals | ||||||||||||
6 | 24V AC | 7VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | 10 hp @ 230 V AC 15 hp @ 460 V AC 15 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
6 | 120V AC | 7VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | 10 hp @ 230 V AC 15 hp @ 460 V AC 15 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
6 | 24V DC | 3.1W | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | 10 hp @ 230 V AC 15 hp @ 460 V AC 15 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
6 | 208V AC, 240V AC | 7VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | 10 hp @ 230 V AC 15 hp @ 460 V AC 15 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
4 Circuits Controlled with 4 Off (Normally Open)—4PST-NO | ||||||||||||
With Quick-Disconnect and Screw Terminals | ||||||||||||
8 | 24V AC | 50.4VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | 10 hp @ 230 V AC 15 hp @ 460 V AC 15 hp @ 575 V AC | 3.8" | 2.7" | 3.4" | 0.25" | 00000000 | 000000 |
8 | 120V AC | 50.4VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | 10 hp @ 230 V AC 15 hp @ 460 V AC 15 hp @ 575 V AC | 3.8" | 2.7" | 3.4" | 0.25" | 00000000 | 000000 |
8 | 24V DC | 5.1W | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | 10 hp @ 230 V AC 15 hp @ 460 V AC 15 hp @ 575 V AC | 3.8" | 2.7" | 3.4" | 0.25" | 00000000 | 000000 |
8 | 208V AC, 240V AC | 50.4VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | 10 hp @ 230 V AC 15 hp @ 460 V AC 15 hp @ 575 V AC | 3.8" | 2.7" | 3.4" | 0.25" | 00000000 | 000000 |
Enclosures for 60A 3PST-NO Relays and 4PST-NO Relays | 00000000 | Each | 0000000 |
Touch-Safe DIN-Rail Mount Infrequent-Cycle Relays
Operate equipment that cycles on and off from your control cabinet. Often called definite-purpose contactors, these relays meet UL 508 for use with air conditioning and heating. They mount directly to 35 mm DIN rail (also known as DIN 3 rail) for fast installation. These relays have recessed terminals that prevent fingers and other objects from touching live circuits.
Auxiliary contacts (sold separately) allow you to add a signaling device or control another relay.
For technical drawings and 3-D models, click on a part number.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/911/9114t371c1-d01c-digital-master1551467810-p9@halfx_636676078023373348.png?ver=imagenotfound)
Switching Current @ 600V AC | hp @ Switching Voltage | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Power | Full Load | Resistive Load | Max. Switching Voltage | Single Phase | Three Phase | Ht. | Wd. | Dp. | Each | |
Relays | ||||||||||||
4 Circuits Controlled with 4 Off (Normally Open)—4PST-NO | ||||||||||||
12 | 24V AC | 6.5VA | 20A | 30A | 600V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 000000 |
12 | 24V AC | 6.5VA | 25A | 30A | 600V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 24V AC | 6.5VA | 30A | 32A | 600V AC | 2 hp @ 120 V AC 5 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 120V AC | 6.5VA | 20A | 30A | 600V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 120V AC | 6.5VA | 25A | 30A | 600V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 120V AC | 6.5VA | 30A | 32A | 600V AC | 2 hp @ 120 V AC 5 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 240V AC | 6.5VA | 20A | 30A | 600V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 240V AC | 6.5VA | 25A | 30A | 600V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 240V AC | 6.5VA | 30A | 32A | 600V AC | 2 hp @ 120 V AC 5 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 24V DC | 5.4W | 20A | 30A | 600V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | 0000000 | 000000 |
Relays with 1 Off (Normally Open) Auxiliary Contact | ||||||||||||
3 Circuits Controlled with 3 Off (Normally Open)—3PST-NO | ||||||||||||
12 | 24V AC | 6.5VA | 20A | 30A | 600V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 24V AC | 6.5VA | 25A | 30A | 600V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 24V AC | 6.5VA | 30A | 32A | 600V AC | 2 hp @ 120 V AC 5 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 120V AC | 6.5VA | 20A | 30A | 600V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 120V AC | 6.5VA | 25A | 30A | 600V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 120V AC | 6.5VA | 30A | 32A | 600V AC | 2 hp @ 120 V AC 5 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 240V AC | 6.5VA | 20A | 30A | 600V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 24V DC | 5.4W | 20A | 30A | 600V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | 0000000 | 000000 |
12 | 24V DC | 5.4W | 25A | 30A | 600V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | 0000000 | 000000 |
12 | 24V DC | 5.4W | 30A | 32A | 600V AC | 2 hp @ 120 V AC 5 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | 0000000 | 000000 |
High-Starting-Current Vehicle Relays
![](/prerenderstable/mvPRE/contents/gfx/imagecache/967/9672k31c1-d01c-digital-master1551470515-p9@halfx_636598422852049303.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/967/9672k29c1-d01c-digital-master1551467820-p9@halfx_636827980571855428.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/822/8228k13p1-@halfx_636957645588385648.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/822/8228k42p1-@halfx_636957645359958546.png?ver=imagenotfound)
Crimp-On
Terminals
Also known as automotive relays, these relays can handle high starting (inrush) currents.
Relays for surface mounting have a tab for added security in high-vibration applications.
Relays | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current @ Voltage | Relay Sockets with Crimp-On Terminals | Relay Sockets with Wire Leads | ||||||||||||||
Number of Terminals | Input Voltage | Off (Normally Open) Circuit Position | On (Normally Closed) Circuit Position | Max. Switching Voltage | Max. Starting Current, A | Control Current, mA | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | Each | |||
For Relay Socket | ||||||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||||
5 | 12V DC | 30 A @ 12 V DC | 20 A @ 12 V DC | 18V DC | 150 | 138 | 1.02" | 1.02" | 0.94" | 0.25" | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 000000 |
For Relay Socket and Surface Mounting | ||||||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||||
5 | 12V DC | 30 A @ 12 V DC | 20 A @ 12 V DC | 18V DC | 150 | 138 | 1.1" | 1.1" | 1" | 0.25" | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
Analog-Input Proportional-Control Relays
![](/prerenderstable/mvPRE/contents/gfx/imagecache/704/7048n15-@halfx_1691090512.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/704/7048n19-@halfx_1691090604.png?ver=imagenotfound)
Often used to regulate the speed of AC fans or keep a heater at a set temperature, these relays connect directly to sensors to calculate and adjust output power. This allows you to use an analog input without converting it to a digital signal to control output power. They are solid state and have no moving parts, so they require less maintenance and last longer, are quieter, and switch faster than mechanical relays. IP20 rated, they have recessed terminals that prevent fingers and other objects from touching live circuits. An integrated heat sink disperses heat to increase the relay’s current rating. The LED indicator shows input voltage loss and internal relay faults, so you can easily check that your system is operating properly.
Mount them on 35 mm DIN rail (also known as DIN 3 rail) for fast installation. They also mount to flat surfaces.
All relays have phase-angle switching to accurately control all types of loads. This mode signals at non-zero voltage, which can produce electrical noise. Choose relays with full-cycle switching for resistive loads. This mode signals at zero voltage, so electrical interference is lower than phase-angle switching.
Single-phase relays can be set to switch every 1, 4, or 16 cycles. When used with infrared heaters, they have an option to switch at the half cycle and again at the full cycle. When switching at 16 cycles or at the half cycle, these relays have a soft-start option to increase the output slower in high-inrush current applications.
Three-phase relays switch every cycle.
Relays with a potentiometer input can connect to an external potentiometer for manual control.
For technical drawings and 3-D models, click on a part number.
Input | Output | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Voltage | Current | No. of | Voltage | Current | No. of | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage | Ht. | Wd. | Dp. | Features | Each | |
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | |||||||||||||||
Single Phase with Phase Angle Switching Mode | |||||||||||||||
4 | __ | 4-20mA | 1 | 85-265V AC | 30A | 1 | 50 | 30 A @ 230 V AC | 265V AC | 4.33" | 1.4" | 4.08" | Integrated Heat Sink, LED Indicator, Recessed Terminals | 0000000 | 0000000 |
4 | __ | 4-20mA | 1 | 190-550V AC | 30A | 1 | 50 | 30 A @ 480 V AC | 550V AC | 4.33" | 1.4" | 4.08" | Integrated Heat Sink, LED Indicator, Recessed Terminals | 0000000 | 000000 |
9 | 0-10V DC | __ | 1 | 85-265V AC | 30A | 1 | 50 | 30 A @ 230 V AC | 265V AC | 4.33" | 1.4" | 4.08" | Integrated Heat Sink, LED Indicator, Recessed Terminals, Potentiometer Input | 0000000 | 000000 |
9 | 0-10V DC | __ | 1 | 190-550V AC | 30A | 1 | 50 | 30 A @ 480 V AC | 550V AC | 4.33" | 1.4" | 4.08" | Integrated Heat Sink, LED Indicator, Recessed Terminals, Potentiometer Input | 0000000 | 000000 |
3 Circuits Controlled with 3 Off (Normally Open)—3PST-NO | |||||||||||||||
Three Phase with Phase Angle and Full Cycle Switching Mode | |||||||||||||||
8 | __ | 4-20mA | 1 | 180-660V AC | 30A | 3 | 50 | 30 A @ 600 V AC | 660V AC | 4.3" | 2.84" | 4.95" | Integrated Heat Sink, LED Indicator, Recessed Terminals | 0000000 | 000000 |
Solid State Surface-Mount Timer Relays
![](/prerenderstable/mvPRE/contents/gfx/imagecache/745/7457k35c1-d01c-digital-master1550881232-p9@halfx_636598986844970000.png?ver=imagenotfound)
Attach these relays to a flat surface using the mounting hole. They have no moving parts, so compared to mechanical switches, they require less maintenance, last longer, and are quieter.
Delayed start (delay-on-make) relays allow you to set how long it takes for the relay to turn on after input voltage is applied. For example, a drill starts pumping a lubricant immediately, but it does not start rotating until the set time has elapsed.
Delayed switch-off (delay-on-break) relays activate with a switch instead of input voltage. When the switch is turned off, the relay remains on for a programmed amount of time before turning off. For example, a projector’s light is turned off with a switch, but its cooling fan continues to run for a set time.
Interval relays use input voltage to turn on for a programmed amount of time. For example, when a part moving down a conveyor reaches a certain location, a cleaning spray comes on for a set time.
Repeat cycle relays turn on for a duration, then off for the same duration. They alternate between the two cycles until input voltage is removed. A common example would be a flashing light.
Switch-on (single-shot) relays require a switch to activate the relay. They’ll stay on for a programmed amount of time. For example, lights in a storage room are turned on with a switch and stay on for a set time before turning off.
For technical drawings and 3-D models, click on a part number.
Timing Range | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | No. of | Overall | Switching Current @ Voltage | Max. Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Each | |
Delayed Start (Delay-on-Make) | ||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||
5 | 120V AC | 36 | 1 | 0.1 sec.-10 sec. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 000000 |
5 | 120V AC | 36 | 1 | 0.1 min.-10 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 1 min.-100 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 0.1 sec.-10 sec. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 0.1 min.-10 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 1 min.-100 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
Delayed Switch-Off (Delay-on-Break) | ||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||
6 | 120V AC | 36 | 1 | 0.1 sec.-10 sec. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
6 | 120V AC | 36 | 1 | 0.1 min.-10 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
6 | 120V AC | 36 | 1 | 1 min.-100 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
6 | 24V DC | 41 | 1 | 0.1 sec.-10 sec. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
6 | 24V DC | 41 | 1 | 0.1 min.-10 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
6 | 24V DC | 41 | 1 | 1 min.-100 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
Interval | ||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||
5 | 120V AC | 36 | 1 | 0.1 sec.-10 sec. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 0.1 min.-10 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 1 min.-100 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 0.1 sec.-10 sec. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 0.1 min.-10 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 1 min.-100 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
Repeat Cycle | ||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||
5 | 120V AC | 36 | 1 | 0.1 sec.-10 sec. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 0.1 min.-10 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
5 | 120V AC | 36 | 1 | 1 min.-100 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 0.1 sec.-10 sec. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 0.1 min.-10 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
5 | 24V DC | 41 | 1 | 1 min.-100 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
Switch-On (Single-Shot) | ||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||
6 | 120V AC | 36 | 1 | 0.1 sec.-10 sec. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
6 | 120V AC | 36 | 1 | 1 sec.-100 sec. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
6 | 120V AC | 36 | 1 | 10 sec.-1,000 sec. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
6 | 120V AC | 36 | 1 | 0.1 min.-10 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
6 | 120V AC | 36 | 1 | 1 min.-100 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
6 | 24V DC | 41 | 1 | 0.1 sec.-10 sec. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
6 | 24V DC | 41 | 1 | 1 sec.-100 sec. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
6 | 24V DC | 41 | 1 | 0.1 min.-10 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
6 | 24V DC | 41 | 1 | 1 min.-100 min. | 30 A @ 240 V AC/24 V DC | 240V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3" | 2" | 1.4" | 00000000 | 00000 |
Energy-Saving Motor Starters
![](/prerenderstable/mvPRE/contents/gfx/imagecache/711/7112t44-@halfx_637114785353057791.png?ver=imagenotfound)
Save electricity and extend motor life by reducing the motor's starting current. These starters gradually start and stop motors. Use them on motors where torque varies, such as pumps, compressors, and conveyors. All have an auxiliary contact to send a signal or connect to another device, such as an alarm or indicating light.
For technical drawings and 3-D models, click on a part number.
Switching | Time, sec. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Full Load Current, A | Input Voltage | Voltage | Current | Electrical Phase (hp) | Acceleration | Deceleration | Ht. | Wd. | Mount. Location | For DIN Rail Ht., mm | Each | |
Motor Starters with 1 Auxiliary Contact—1 Off (Normally Open) | ||||||||||||
28 | 24V DC | 208-600V AC | 30A | Three (10 hp @ 240 V AC) Three (20 hp @ 480 V AC) | 1-20 | 0-20 | 6.3" | 1.8" | DIN Rail, Surface | 35 | 0000000 | 0000000 |