About Timer Relays
More
Spade-Terminal Relays
Using a low-current signal, these relays are often used to control small motors and heaters. These relays attach to quick-disconnect terminals.
Surface mount relays, also known as power relays, have a slot on the flange for mounting them to flat surfaces.
Relay-socket mount relays, also known as ice cube relays, offer three ways to connect. Plug them into a socket (sold separately), connect them with quick-disconnect terminals, or solder wires directly to the terminals.
Relay-socket/surface mount relays can plug into a socket or mount to a flat surface.
Relay sockets mount directly on 35 mm DIN rail (also known as DIN 3 rail) for fast installation. They can also mount to a flat surface.

Number of Terminals | Input Voltage | Control Current, mA | Maximum Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
6 | 12V DC | 158 | 250V AC | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC 2 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 000000 |
6 | 24V AC | 71 | 250V AC | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC 2 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
6 | 24V DC | 79 | 250V AC | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC 2 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
6 | 120V AC | 20 | 250V AC | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC 2 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
6 | 240V AC | 10 | 250V AC | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC 2 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
DIN-Rail Mount Solid State Relays


Unlike mechanical relays, these solid state relays have no moving parts, so they require less maintenance and last longer, switch faster, and are quieter. They mount on 35 mm DIN rail (also known as DIN 3) for fast installation. An LED indicator lights up when these relays are connected, so you can quickly confirm that they’re wired correctly. IP20 rated, their terminals are recessed, so they prevent fingers and other objects from touching live circuits.
Relays with an integrated heat sink disperse heat to increase the relay’s current rating.
Relays with an integrated fan are best for applications that generate more heat. The fan automatically turns on to provide additional cooling. When the temperature exceeds 176° F, an alarm sends a signal to an external device, such as a controller or indicating light.
For technical drawings and 3-D models, click on a part number.
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage (Load Type) | Max. Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Features | Each | |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Two Phase | |||||||||||
6 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 2 | 25 A @ 220 V AC (Full Load) | 242V AC | 1 1/2 hp @ 115 V AC 3 hp @ 230 V AC | 4.33" | 2.13" | 3.427" | Integrated Heat Sink, LED Indicator | 0000000 | 0000000 |
6 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 2 | 25 A @ 600 V AC (Full Load) | 660V AC | 5 hp @ 230 V AC 10 hp @ 480 V AC | 4.33" | 2.13" | 3.427" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
6 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 2 | 40 A @ 600 V AC (Full Load) | 660V AC | 5 hp @ 230 V AC 10 hp @ 480 V AC | 4.33" | 2.84" | 4.66" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
6 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 2 | 75 A @ 600 V AC (Full Load) | 660V AC | 10 hp @ 230 V AC 20 hp @ 480 V AC | 5.55" | 2.84" | 4.679" | Integrated Heat Sink, Integrated Fan, LED Indicator | 0000000 | 000000 |
6 | 5V DC, 6V DC, 12V DC, 24V DC, 30V DC | 10 | 25 A @ 220 V AC (Full Load) | 242V AC | 1 1/2 hp @ 115 V AC 3 hp @ 230 V AC | 4.33" | 2.13" | 3.427" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
6 | 5V DC, 6V DC, 12V DC, 24V DC, 30V DC | 10 | 25 A @ 600 V AC (Full Load) | 660V AC | 5 hp @ 230 V AC 10 hp @ 480 V AC | 4.33" | 2.13" | 3.427" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
6 | 5V DC, 6V DC, 12V DC, 24V DC, 30V DC | 10 | 40 A @ 600 V AC (Full Load) | 660V AC | 5 hp @ 230 V AC 10 hp @ 480 V AC | 4.33" | 2.84" | 4.66" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
6 | 5V DC, 6V DC, 12V DC, 24V DC, 30V DC | 10 | 75 A @ 600 V AC (Full Load) | 660V AC | 10 hp @ 230 V AC 20 hp @ 480 V AC | 5.55" | 2.84" | 4.679" | Integrated Heat Sink, Integrated Fan, LED Indicator | 0000000 | 000000 |
DIN-Rail Mount Touch-Safe Screw Terminal Relays
Quickly and safely mount these relays on 35 mm DIN rail (also known as DIN 3). IP20 rated, they have recessed terminals that prevent fingers and other objects from touching live circuits.
Auxiliary contacts (sold separately) allow you to add a signaling device or control another relay. You can add one auxiliary contact to all of these relays. For relays with 12 terminals, you can add two side-mount auxiliary contacts.
Use replacement coils to swap out a broken coil or change the input voltage of a relay. They are only compatible with relays that have 12 terminals. The full load current of the relay must match the full load current range of the coil.
For technical drawings and 3-D models, click on a part number.

Control | hp @ Switching Voltage | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Power | Switching Current @ Voltage (Load Type) | Max. Switching Voltage | Single Phase | Ht. | Wd. | Dp. | Each | |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | ||||||||||
6 | 24V AC, 24V DC | 2VA | 25 A @ 240 V AC (Resistive Load) | 240 V AC | 3/4 hp @ 120 V AC 2 hp @ 240 V AC | 3.5" | 0.7" | 2.4" | 0000000 | 000000 |
6 | 120V AC, 120V DC | 2VA | 25 A @ 240 V AC (Resistive Load) | 240 V AC | 3/4 hp @ 120 V AC 2 hp @ 240 V AC | 3.5" | 0.7" | 2.4" | 0000000 | 00000 |
Circuit Board Relays


Smaller than relays with electrical wiring, these relays fit in compact devices. Mount them through holes on circuit boards with their solder pin terminals. Use them to control heaters, fans, and other high-power components from a low-power circuit.
For technical drawings and 3-D models, click on a part number.
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage | Mechanical Life Cycles | Ht. | Wd. | Dp. | Pin Lg. | Each | |
Mechanical | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | |||||||||||
6 | 12V DC | 141 | 50 A @ 400 V AC | 400V AC | 1,000,000 | 2" | 1.3" | 2.3" | 0.18" | 0000000 | 000000 |
14 | 12V DC | 240 | 100 A @ 400 V AC | 400V AC | 1,000,000 | 2.1" | 2.1" | 2.3" | 0.18" | 0000000 | 00000 |
14 | 24V DC | 120 | 100 A @ 400 V AC | 400V AC | 1,000,000 | 2.1" | 2.1" | 2.3" | 0.18" | 0000000 | 00000 |
Solid State Screw Terminal Relays


With no moving parts, these solid-state relays are fast switching and require less maintenance, last longer, and are quieter than mechanical switches.
Relays with high-starting-current protection are designed with integrated circuits that prevent damage from the large burst of electricity when a device, such as a motor or pump, turns on.
Relays with LED indicator let you quickly spot whether a relay is on or off.
Heat sinks disperse heat to increase the relay’s current rating. Mount them to 35 mm DIN rail (also known as DIN 3 rail) for fast installation. They also mount to flat surfaces. Before mounting one-circuit relays, silicone compound or a thermal pad should be placed between the heat sink and relay. Silicone compound is sold separately for heat sinks that do not include it but require it. Two-circuit relays don’t require silicone for mounting.
For technical drawings and 3-D models, click on a part number.
Relays | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current | Heat Sinks | ||||||||||||
Number of Terminals | Input Voltage | Without Heat Sink | With Heat Sink | Switching Voltage | Max. Switching Voltage | Ht. | Wd. | Dp. | Environmental Rating | Each | Each | ||
2 Circuit Controlled with 2 Off (Normally Open)—DPST-NO | |||||||||||||
Relays with High-Starting-Current Protection and Covered Terminals and LED Indicator | |||||||||||||
6 | 4V DC, 6V DC, 12V DC, 24V DC, 30V DC | 5A | 50A | 600V AC | 660V AC | 2.3" | 1.8" | 1.3" | IP20 | 0000000 | 0000000 | 0000000 | 0000000 |
6 | 4V DC, 6V DC, 12V DC, 24V DC, 30V DC | 7.5A | 75A | 600V AC | 660V AC | 2.3" | 1.8" | 1.3" | IP20 | 0000000 | 000000 | 0000000 | 000000 |
Open-Style Screw Terminal Relays

Use these relays with industrial automation systems, security and emergency lighting, and small motors. They’re also known as power relays. Hardwire them to your circuit using the screw terminals.
Optional covers protect contacts from dust and dirt.
For technical drawings and 3-D models, click on a part number.
Relays | Optional Covers | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Each | Each | ||
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | ||||||||||||
6 | 24V AC | 395 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 000000 | 0000000 | 000000 |
6 | 120V AC | 79 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
6 | 240V AC | 40 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
6 | 12V DC | 167 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
6 | 24V DC | 83 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
Infrequent-Cycle Relays

For use with equipment that cycles on and off, these relays meet UL 508 for air conditioning and heating. Connections are accessible from the front, so you can mount relays side-by-side. Also known as definite-purpose contactors.
Also Available: Auxiliary contacts for 3.8"-7.2" Ht. relays. They allow you to add a signaling device or control another relay. Please select 6564K99, then select the McMaster-Carr part number of your relay and whether you want to switch one circuit on (1 Normally Open) or off (1 Normally Closed).
For technical drawings and 3-D models, click on a part number.
Switching Current @ 600V AC | hp @ Switching Voltage | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Power | Full Load | Resistive Load | Single Phase | Three Phase | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | ||||||||||||
With Quick-Disconnect and Screw Terminals | ||||||||||||
4 | 24V AC | 6.5VA | 20A | 30A | 1 1/2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 000000 |
4 | 24V AC | 6.5VA | 25A | 35A | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
4 | 24V AC | 6.5VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
4 | 24V AC | 6.5VA | 40A | 50A | 3 hp @ 115 V AC 7 1/2 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 000000 |
4 | 24V AC | 7VA | 15A | 20A | 3/4 hp @ 115 V AC 2 hp @ 230 V AC | 3 hp @ 230 V AC 5 hp @ 460 V AC 5 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 00000 |
4 | 24V AC | 10VA | 50A | 65A | 3 hp @ 115 V AC 10 hp @ 230 V AC | 15 hp @ 230 V AC 30 hp @ 460 V AC 30 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
4 | 24V AC | 19VA | 90A | 120A | 7 1/2 hp @ 115 V AC 20 hp @ 230 V AC | 30 hp @ 230 V AC 50 hp @ 460 V AC 50 hp @ 575 V AC | 5" | 3.7" | 4.4" | 0.25" | 00000000 | 000000 |
4 | 24V AC | 50.4VA | 60A | 75A | 5 hp @ 115 V AC 10 hp @ 230 V AC | 20 hp @ 230 V AC 40 hp @ 460 V AC 40 hp @ 575 V AC | 3.8" | 2.6" | 4" | 0.25" | 00000000 | 000000 |
4 | 24V AC | 50.4VA | 75A | 90A | 5 hp @ 115 V AC 15 hp @ 230 V AC | 20 hp @ 230 V AC 50 hp @ 460 V AC 50 hp @ 575 V AC | 3.8" | 2.6" | 4" | 0.25" | 00000000 | 000000 |
4 | 120V AC | 6.5VA | 20A | 30A | 1 1/2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
4 | 120V AC | 6.5VA | 25A | 35A | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
4 | 120V AC | 6.5VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
4 | 120V AC | 6.5VA | 40A | 50A | 3 hp @ 115 V AC 7 1/2 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 000000 |
4 | 120V AC | 7VA | 15A | 20A | 3/4 hp @ 115 V AC 2 hp @ 230 V AC | 3 hp @ 230 V AC 5 hp @ 460 V AC 5 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 00000 |
4 | 120V AC | 10VA | 50A | 65A | 3 hp @ 115 V AC 10 hp @ 230 V AC | 15 hp @ 230 V AC 30 hp @ 460 V AC 30 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
4 | 120V AC | 19VA | 90A | 120A | 7 1/2 hp @ 115 V AC 20 hp @ 230 V AC | 30 hp @ 230 V AC 50 hp @ 460 V AC 50 hp @ 575 V AC | 5" | 3.7" | 4.4" | 0.25" | 00000000 | 000000 |
4 | 120V AC | 50.4VA | 60A | 75A | 5 hp @ 115 V AC 10 hp @ 230 V AC | 20 hp @ 230 V AC 40 hp @ 460 V AC 40 hp @ 575 V AC | 3.8" | 2.6" | 4" | 0.25" | 00000000 | 000000 |
4 | 120V AC | 50.4VA | 75A | 90A | 5 hp @ 115 V AC 15 hp @ 230 V AC | 20 hp @ 230 V AC 50 hp @ 460 V AC 50 hp @ 575 V AC | 3.8" | 2.6" | 4" | 0.25" | 00000000 | 000000 |
4 | 24V DC | 3.1W | 15A | 20A | 3/4 hp @ 115 V AC 2 hp @ 230 V AC | 3 hp @ 230 V AC 5 hp @ 460 V AC 5 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
4 | 24V DC | 3.1W | 25A | 35A | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
4 | 24V DC | 3.1W | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | __ | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
4 | 24V DC | 3.1W | 40A | 50A | 3 hp @ 115 V AC 7 1/2 hp @ 230 V AC | __ | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
4 | 24V DC | 3.1W | 50A | 65A | 3 hp @ 115 V AC 10 hp @ 230 V AC | 15 hp @ 230 V AC 30 hp @ 460 V AC 30 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
4 | 24V DC | 5.1W | 60A | 75A | 5 hp @ 115 V AC 10 hp @ 230 V AC | 20 hp @ 230 V AC 40 hp @ 460 V AC 40 hp @ 575 V AC | 3.8" | 2.6" | 4" | 0.25" | 00000000 | 000000 |
4 | 24V DC | 5.1W | 75A | 90A | 5 hp @ 115 V AC 15 hp @ 230 V AC | 20 hp @ 230 V AC 50 hp @ 460 V AC 50 hp @ 575 V AC | 3.8" | 2.6" | 4" | 0.25" | 00000000 | 000000 |
4 | 208V AC, 240V AC | 6.5VA | 20A | 30A | 1 1/2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
4 | 208V AC, 240V AC | 6.5VA | 25A | 35A | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
4 | 208V AC, 240V AC | 6.5VA | 30A | 40A | 2 hp @ 115 V AC 5 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
4 | 208V AC, 240V AC | 6.5VA | 40A | 50A | 3 hp @ 115 V AC 7 1/2 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 000000 |
4 | 208V AC, 240V AC | 7VA | 15A | 20A | 3/4 hp @ 115 V AC 2 hp @ 230 V AC | 3 hp @ 230 V AC 5 hp @ 460 V AC 5 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 00000 |
4 | 208V AC, 240V AC | 10VA | 50A | 65A | 3 hp @ 115 V AC 10 hp @ 230 V AC | 15 hp @ 230 V AC 30 hp @ 460 V AC 30 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
4 | 208V AC, 240V AC | 19VA | 90A | 120A | 7 1/2 hp @ 115 V AC 20 hp @ 230 V AC | 30 hp @ 230 V AC 50 hp @ 460 V AC 50 hp @ 575 V AC | 5" | 3.7" | 4.4" | 0.25" | 00000000 | 000000 |
4 | 208V AC, 240V AC | 50.4VA | 60A | 75A | 5 hp @ 115 V AC 10 hp @ 230 V AC | 20 hp @ 230 V AC 40 hp @ 460 V AC 40 hp @ 575 V AC | 3.8" | 2.6" | 4" | 0.25" | 00000000 | 000000 |
4 | 208V AC, 240V AC | 50.4VA | 75A | 90A | 5 hp @ 115 V AC 15 hp @ 230 V AC | 20 hp @ 230 V AC 50 hp @ 460 V AC 50 hp @ 575 V AC | 3.8" | 2.6" | 4" | 0.25" | 00000000 | 000000 |
Sequenced Latching Relays

These relays switch through a series of different circuit configurations every time they receive an input voltage. The input voltage latches them in position, so they don’t require a constant voltage to stay switched. Use them to control motors, pumps, and lighting. The covered terminals prevent contact with live connections. Mount to 35 mm DIN rail. Also known as step relays.
For technical drawings and 3-D models, click on a part number.
Switch Starting Position | Input Voltage | Control Power | Switching Current @ 120V AC | Max. Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Each | |
2 Circuits Controlled—DPST-NO | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
With 6 Terminals | ||||||||||
1st Signal—2 Off (Normally Open) 2nd Signal—2 On (Normally Closed) | 24V AC | 6.5VA | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 000000 |
1st Signal—2 Off (Normally Open) 2nd Signal—2 On (Normally Closed) | 120V AC | 6.5VA | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—2 Off (Normally Open) 2nd Signal—2 On (Normally Closed) | 240V AC | 6.5VA | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—2 Off (Normally Open) 2nd Signal—2 On (Normally Closed) | 12V DC | 5W | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—2 Off (Normally Open) 2nd Signal—2 On (Normally Closed) | 24V DC | 5W | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—2 Off (Normally Open) 2nd Signal—1 On (Normally Closed) and 1 Off (Normally Open) 3rd Signal—2 On (Normally Closed) | 24V AC | 6.5VA | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—2 Off (Normally Open) 2nd Signal—1 On (Normally Closed) and 1 Off (Normally Open) 3rd Signal—2 On (Normally Closed) | 120V AC | 6.5VA | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—2 Off (Normally Open) 2nd Signal—1 On (Normally Closed) and 1 Off (Normally Open) 3rd Signal—2 On (Normally Closed) | 240V AC | 6.5VA | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—2 Off (Normally Open) 2nd Signal—1 On (Normally Closed) and 1 Off (Normally Open) 3rd Signal—2 On (Normally Closed) | 12V DC | 5W | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—2 Off (Normally Open) 2nd Signal—1 On (Normally Closed) and 1 Off (Normally Open) 3rd Signal—2 On (Normally Closed) | 24V DC | 5W | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
Enclosed Relays

An enclosure covers the terminals on these relays to help prevent damage from dust or accidental bumps. They have an LED indicator, so you can quickly see what switching position your relay is in. Hardwire them to your equipment with the included wire leads. Rated NEMA 1, these relays are intended for indoor use only.
For technical drawings and 3-D models, click on a part number.
Wire Lead | Conduit Connection | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input Voltage | Control Current, mA | Switching Current @ 277V AC | Max. Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Lg. | Number of | Gender | Trade Size | Thread Type | Environmental Rating | Each | |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | |||||||||||||||
120V AC | 105 | 30A | 277V AC | 1 hp @ 120 V AC 2 hp @ 277 V AC | 4" | 4" | 1.8" | 16" | 6 | Male | 1/2 | NPT | NEMA 1 | 0000000 | 000000 |
208V AC, 240V AC, 277V AC | 105 | 30A | 277V AC | 1 hp @ 120 V AC 2 hp @ 277 V AC | 4" | 4" | 1.8" | 16" | 6 | Male | 1/2 | NPT | NEMA 1 | 0000000 | 00000 |
High-Current Lighting Relays
Switch lighting systems on and off—these relays can handle the high switching current on large overhead light systems. They control multiple circuits, so you can manage several lights across your facility with just one relay. For example, use them to switch overhead lights along with lighted signs in different parts of your warehouse. These relays come set for normally-open switching, but you can change them to normally-closed by turning the contacts around with a screwdriver.
Electrically held relays can handle switching on and off frequently. However, because they need constant input voltage to keep the relay switched, they make a humming noise when switched on.
Mechanically held relays are ideal for applications that don’t need to be switched very often, such as lights that stay on all day. Since they switch on and off with a quick burst of input voltage rather than needing constant power, they’re more energy efficient than electrically held relays.

Number of Terminals | Input Voltage | Control Power | Switching Current @ Voltage (Light Technology) | Max. Switching Voltage | Mechanical Life Cycles | Ht. | Wd. | Dp. | Each | |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
6 | 120V AC | 30VA | 30 A @ 120 V AC (Fluorescent) 20 A @ 120 V AC (Tungsten) | 132V AC | 4,000,000 | 5" | 2.9" | 3.1" | 0000000 | 0000000 |

Number of Terminals | Input Voltage | Control Power | Switching Current @ Voltage (Light Technology) | Max. Switching Voltage | Mechanical Life Cycles | Ht. | Wd. | Dp. | Each | |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
6 | 120V AC | 30VA | 30 A @ 120 V AC (Fluorescent) 20 A @ 120 V AC (Tungsten) | 132V AC | 1,000,000 | 8.8" | 2.9" | 3.3" | 0000000 | 0000000 |
High-Starting-Current DIN-Rail Mount Timer Relays

Reduce voltage fluctuations and stress on shafts and bearings when starting up three-phase motors. These timer relays start with motor contacts in a star configuration, then switch to a delta configuration after a set delay. Since star configuration takes less voltage to start than delta, these relays prevent voltage dips that often happen when a motor starts and are gentler on mechanical parts. Mount these relays directly to 35 mm DIN rail (also known as DIN 3 rail) for quick installation.
For technical drawings and 3-D models, click on a part number.
Timing Range | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Terminals | Input Voltage | Control Current, mA | Timer Relay Function | No. of | Overall | Switching Current @ 240V AC | Max. Switching Voltage | Ht. | Wd. | Dp. | Each | |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | ||||||||||||
5 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 30V DC, 48V DC, 60V DC, 120V DC, 240V DC | 5 | Star-to-Delta | 6 | 0.1 sec.-20 min. | 6A | 250V AC | 3.4" | 0.7" | 2.4" | 0000000 | 000000 |