Circuit Board Safety Relays

Reduce connection errors on circuit boards that control machine guards and other safety devices. Also known as force-guided contact relays, they have contact pairs that won’t close at the same time, even if contacts stick or weld shut. These relays take up less space on a board than those with electrical wiring because their solder pin terminals mount directly through circuit board holes. Use them to control high-power components, such as fans and heaters, from a low-power circuit.
Relays with surge suppression coverage protect sensitive electronics from damage and malfunction by eliminating voltage spikes. Switching off a relay can generate surges of 300 to 500 volts, but a diode within these relays suppresses these surges. An LED indicator on these relays lights up when they’re on, so you know at a glance if they’re wired correctly.
For technical drawings and 3-D models, click on a part number.
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage | Mechanical Life Cycles | Ht. | Wd. | Dp. | Pin Lg. | Features | Surge Suppression Coverage | Each | |
6 Circuits Controlled with 3 Off (Normally Open) and 3 On (Normally Closed)—6PST-3NO/3NC | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
14 | 12V DC | 41 | 6 A @ 240 V AC/30 V DC | 250V AC, 125V DC | 10,000,000 | 0.9" | 0.5" | 2" | 0.14" | Interlocked Opposing Contacts | __ | 0000000 | 000000 |
14 | 12V DC | 43 | 6 A @ 240 V AC/30 V DC | 250V AC, 125V DC | 10,000,000 | 0.9" | 0.5" | 2" | 0.14" | Interlocked Opposing Contacts, LED Indicator | Full | 0000000 | 00000 |
14 | 24V DC | 20 | 6 A @ 240 V AC/30 V DC | 250V AC, 125V DC | 10,000,000 | 0.9" | 0.5" | 2" | 0.14" | Interlocked Opposing Contacts | __ | 0000000 | 00000 |
14 | 24V DC | 22 | 6 A @ 240 V AC/30 V DC | 250V AC, 125V DC | 10,000,000 | 0.9" | 0.5" | 2" | 0.14" | Interlocked Opposing Contacts, LED Indicator | Full | 0000000 | 00000 |