Spade-Terminal Relays
Using a low-current signal, these relays are often used to control small motors and heaters. These relays attach to quick-disconnect terminals.
Surface mount relays, also known as power relays, have a slot on the flange for mounting them to flat surfaces.
Relay-socket mount relays, also known as ice cube relays, offer three ways to connect. Plug them into a socket (sold separately), connect them with quick-disconnect terminals, or solder wires directly to the terminals.
Relay-socket/surface mount relays can plug into a socket or mount to a flat surface.
Relay sockets mount directly on 35 mm DIN rail (also known as DIN 3 rail) for fast installation. They can also mount to a flat surface.
For technical drawings and 3-D models, click on a part number.


Relays | Relay Sockets with Screw Terminals | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Maximum Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | ||
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | ||||||||||||
11 | 12V AC | 230 | 250V AC | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 0000000 | 0000000 | 000000 |
11 | 24V AC | 115 | 250V AC | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
11 | 120V AC | 24 | 250V AC | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
11 | 240V AC | 12 | 250V AC | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
11 | 12V DC | 100 | 250V AC | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
11 | 24V DC | 51 | 250V AC | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |


With Screw
Terminals
Relays | Relay Sockets with Screw Terminals | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Maximum Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | ||
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | ||||||||||||
11 | 24V AC | 67 | 250V AC | 1/2 hp @ 240 V AC | 1.8" | 1.3" | 1.4" | 0.2" | 00000000 | 000000 | 0000000 | 000000 |
11 | 24V DC | 59 | 250V AC | 1/2 hp @ 240 V AC | 1.8" | 1.3" | 1.4" | 0.2" | 00000000 | 00000 | 0000000 | 00000 |
Compact Spade-Terminal Relays


Fit these relays where standard spade-terminal relays are too big. You can connect them three ways. Plug them into a socket (sold separately), connect them with quick-disconnect terminals, or solder wires directly to the terminals. An LED indicator shows you the status of the relay, so you know it’s connected and wired correctly.
Relays that control 2 or more circuits have a lockable test button, so you can test their function. When you press the button, the relay switches contacts. Use this button when checking a relay for proper function before installing it, or when investigating issues with wired relays.
Relay sockets mount directly on 35 mm DIN rail (also known as DIN 3 rail) for fast installation. You can also mount them to a flat surface using screws.
For technical drawings and 3-D models, click on a part number.
Relays | Relay Sockets with Screw Terminals | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Maximum Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | ||
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | ||||||||||||
Relay-Socket Mount | ||||||||||||
11 | 24V AC | 63 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | 00000000 | 000000 | 0000000 | 000000 |
11 | 120V AC | 13 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
11 | 240V AC | 6 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
11 | 12V DC | 117 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
11 | 24V DC | 58 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
DIN-Rail Mount Interface Relays

Isolate input and output circuits to prevent damage from voltage spikes, reduce signal interference, and amplify signal. These relays interface between your controller and components—they receive a signal from the controller to switch power on or off to the components. All have an LED indicator that shows you if your switch is actuated, so you know it’s connected and wired correctly. Use them to communicate signals to devices like motors or sensors. Mount them on 35 mm DIN rail (also known as DIN 3 rail).
Relays with PLC output protection prevent voltage spikes created by the relay from damaging the output channel on your programmable logic controller (PLC).
For technical drawings and 3-D models, click on a part number.
Relays with Relay Sockets | Replacement Relays | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ 240V AC | hp @ Switching Voltage | Ht. | Wd. | Dp. | Features | Each | Each | ||
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | ||||||||||||
With Screw Terminals | ||||||||||||
11 | 24V AC | 53 | 10A | 1/3 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 000000 | 00000000 | 000000 |
11 | 120V AC | 12 | 10A | 1/3 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 |
11 | 12V DC | 86 | 10A | 1/3 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 |
11 | 24V DC | 40 | 10A | 1/3 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 |
Circular-Pin Relays


The circular pin terminals plug into relay sockets for easy installation. Also known as ice cube relays.
Relays rated for horsepower (hp) are built to handle tough, repetitive-use applications.
Relays with a lockable test button allow you to test whether a relay is working without an electrical signal. They’re helpful for testing relays before you install them, or for checking that installed relays are working properly.
Relay sockets (sold separately) mount to 35 mm DIN rail (also known as DIN 3 rail) or can be mounted to a flat surface.
Relays | Relay Sockets | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Features | Each | Each | ||
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | |||||||||||||
11 | 24V AC | 84 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 0000000 | 000000 | 0000000 | 000000 |
11 | 24V AC | 96 | 10 A @ 240 V AC | 250V AC | __ | 1.4" | 1.4" | 2.1" | Lockable Test Button | 0000000 | 00000 | 0000000 | 00000 |
11 | 120V AC | 18 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 0000000 | 00000 | 0000000 | 00000 |
11 | 120V AC | 19 | 10 A @ 240 V AC | 250V AC | __ | 1.4" | 1.4" | 2.1" | Lockable Test Button, LED Power Indicator | 0000000 | 00000 | 0000000 | 00000 |
11 | 12V DC | 100 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 0000000 | 00000 | 0000000 | 00000 |
11 | 12V DC | 112 | 10 A @ 240 V AC | 250V AC | __ | 1.4" | 1.4" | 2.1" | Lockable Test Button | 0000000 | 00000 | 0000000 | 00000 |
11 | 24V DC | 52 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 0000000 | 00000 | 0000000 | 00000 |
11 | 24V DC | 55 | 10 A @ 240 V AC | 250V AC | __ | 1.4" | 1.4" | 2.1" | Lockable Test Button | 0000000 | 00000 | 0000000 | 00000 |
11 | 240V AC | 9 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 0000000 | 00000 | 0000000 | 00000 |
11 | 240V AC | 9 | 10 A @ 240 V AC | 250V AC | __ | 1.4" | 1.4" | 2.1" | Lockable Test Button | 0000000 | 00000 | 0000000 | 00000 |
Hazardous Location Relays

Sealed for safety, these relays are a good choice for hazardous locations where combustible or corrosive gases may be present.
Relays with circular-pin terminals or quick-disconnect terminals are hermetically sealed—completely air- and watertight—to shield internal parts from gases, moisture, and other contaminants. They plug into relay sockets (sold separately) for easy installation.
Relay sockets mount to 35 mm DIN rail (also known as DIN 3 rail) or flat surfaces.
For technical drawings and 3-D models, click on a part number.
Relays | Relay Sockets | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Environmental Rating | Each | Each | ||
Circular-Pin Terminals—Hermetically Sealed | |||||||||||||
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | |||||||||||||
11 | 120V AC | 100 | 12 A @ 120 V AC/240 V AC | 300V AC | 1/3 hp @ 120 V AC | 1.6" | 1.4" | 2.1" | NEC Class I Division 2 Groups A, B, C, D | 00000000 | 0000000 | 0000000 | 000000 |