We will reply to your message within an hour.
A finely threaded adjustment screw lets you make precise set pressure adjustments.
To gradually relieve pressure in lines for diesel fuel, fuel oil, gasoline, and kerosene, these valves begin opening at the set pressure and fully open at about 10% over the set pressure.
Design a valve specifically for your process media and set pressure. Choose from a valve for air, inert gas, water, hydraulic oil, fuel oil, gasoline, or diesel fuel and a set pressure.
For installation through thick insulation, these valves have an extra-long stem.
To withstand aggressive and corrosive solutions in miniature chemical-processing pipelines, these tiny valves have a chemical-resistant fluoroelastomer seal and a corrosion-resistant 303 stainless steel body.
Attach gauges or sensors to these valves so you can remove them for maintenance and calibration without depressurizing your line. They are also known as block and bleed valves.
The most chemical-resistant threaded valves we offer, these have a PTFE seal and an alloy body that can withstand extremely aggressive and corrosive chemicals, such as methyl ethyl ketone and toluene.
There’s no need to unbolt these valves for cleaning—remove the valve handle and slide the valve apart for inline access to internal components. Also known as elliptical valves, they have a fluoroelastomer seal and a polypropylene body to withstand aggressive and corrosive solutions in chemical-processing applications.
Insert tubing into the fittings on these valves—no heat, solder, or flux required. To withstand aggressive and corrosive solutions, they have a chemical-resistant fluoroelastomer seal and a plastic body.
Barbs grip onto tubing, providing a secure hold. To withstand aggressive and corrosive solutions in chemical-processing applications, these valves have a plastic body and a chemical-resistant seal.
Bolt these valves to ANSI flanges—they meet ASME dimensional standards. They have a plastic body and a seal that withstand aggressive and corrosive solutions in chemical-processing applications.
Protect personnel and equipment in the presence of diesel fuel, fuel oil, gasoline, and kerosene. Fire-tested to meet American Petroleum Institute (API) 607, Edition 4, these valves are designed to securely isolate fluid and prevent the spread of fire.
A low-profile handle allows these valves to fit in low-clearance pipelines for diesel fuel, fuel oil, and kerosene.
These valves have 37° flared tube fittings that form a tight seal on metal tubing lines to transfer diesel fuel, fuel oil, and gasoline.
For extra gripping power and a strong seal, these valves have Yor-Lok fittings with two sleeves that bite into tubing as you tighten the nut. They are compatible with Swagelok®, Let-Lok, and Parker A-Lok fittings. Use with diesel fuel, fuel oil, gasoline, and kerosene.
For applications sensitive to contamination, these valves stop flow without contacting the process media by pressing down on the outside of tubing.
Supply fuel oil to boilers, furnaces, and other equipment.
Limit wear and damage in high-cycling applications—these valves have additional seals that prevent leakage to reduce maintenance time.
Their ball-valve design allows these valves to handle three times the flow of butterfly valves.
Also known as diaphragm valves, these have a diaphragm that can handle dirty liquid, slurries, and abrasive media without damage.
With a ball-valve design, these valves can handle three times the flow of butterfly valves.
Use these valves to safely transfer fuel and oil.
For three times the flow of butterfly valves, these have a ball valve design.
Use these valves with NPT threaded pipe. They have a fluoroelastomer seal and a plastic body to withstand aggressive and corrosive solutions in chemical-processing applications. Turn the handle to adjust flow in small increments for metering, sampling, and other applications requiring fine flow control.
Valves have NPT connections for use with threaded pipe. Turn the handle to adjust the flow of butane, diesel fuel, fuel oil, gasoline, kerosene, natural gas, and propane in small increments.
Add fine flow control to tubing lines for oil, butane, diesel fuel, fuel oil, gasoline, kerosene, natural gas, and propane. These valves have a barbed fitting that grips onto tubing, providing a secure hold. Turn the handle to adjust flow in small increments.
To automatically shut off the flow of diesel fuel, fuel oil, kerosene, and oil in case of fire, these valves automatically close and the handle permanently fuses in place when the ambient temperature reaches 165° F.
These valves press down on the outside of tubing to adjust flow without contacting the process media.
The most chemical-resistant check valves in our offering, these have a PFA body to withstand methyl ethyl ketone, sodium hypochlorite, and other extremely harsh chemicals.
These valves open to allow flow in one direction and close when flow stops or reverses.
Bolt to ANSI flanges.
Barbs grip onto tubing, providing a secure hold.
For more than twice the temperature rating of standard check valves for oil and fuel, these have a heat-resistant fluoroelastomer seal that can withstand temperatures up to 500° F.
Install these valves between ANSI flanges.
Insert tubing into the fittings on these valves—no heat, solder, or flux required. All are for use with water, oil, air, and inert gas. They divert flow between ports in tubing lines.
There’s no need to unbolt these valves for cleaning—remove the handle and slide the valve apart for inline access to internal components. Also known as elliptical valves, they have a fluoroelastomer seal and a polypropylene body for diverting flow in chemical-processing applications.
Barbed fittings on these valves grip onto tubing, providing a secure hold. To divert flow between ports in chemical-processing applications, they have a chemical-resistant seal and a PVDF body to withstand aggressive and corrosive solutions.
Insert tubing into the fittings on these valves—no heat, solder, or flux required. Designed for diverting flow between ports in chemical tubing lines, they have a fluoroelastomer seal and a PVDF body to withstand aggressive and corrosive solutions.
Often used for chemical analysis and other laboratory testing, these valves have a PTFE seal and body to withstand aggressive and corrosive solutions. They operate on electricity to automatically divert flow between ports.
To minimize fluid loss when connecting and disconnecting your line, these couplings have flat faces for a close fit and shut-off valves to stop the flow—they meet ISO 16028, which is an international standard for hose couplings.
Quickly connect and disconnect hose lines used with a variety of chemicals, from adhesives to isopropyl alcohol and ink. Any part of these couplings that contacts fluid is made from 316 stainless steel, C-276 Hastelloy, PTFE, or fluoroelastomer to withstand the chemicals in your line.
Also known as dry disconnects and double shut-off couplings, these couplings make connecting and disconnecting your line quick and virtually spill-free. Built to stand up to petroleum products, such as diesel fuel and gasoline, their body and gasket are made from materials that won’t corrode from oil.
Minimize chemical and petroleum spills during accidental disconnects, such as a driver pulling away during loading. These couplings have a shut-off valve on each half to stop flow when they’re separated.