How to Identify and Measure Fittings
Pipe size is an industry designation, not the actual size. View information about how to measure threaded and unthreaded pipe and pipe fittings.
More
Standard-Wall Plastic Pipe Fittings for Water
Connect these fittings to Schedule 40 plastic pipe–they are the industry standard for residential and commercial low-pressure plumbing and water supply applications. They are plastic for good corrosion resistance.
Fittings for drinking water meet NSF/ANSI Standard 61.
Attach socket-connect ends to unthreaded pipe or another socket-connect fitting with a PVC primer and cement (also known as solvent weld).
To prevent leaks in threaded connections, apply a sealant to the male threads. For plastic threads, apply a non-hardening, plastic-compatible sealant. Tape or sealants with PTFE are not recommended for plastic-to-plastic connections. Fittings that meet ASTM D1784, ASTM D1785, and ASTM D4066 adhere to specifications and testing requirements for material quality.
Note: For fittings that are not rated for pressure, you can use the pressure rating of the plastic pipe as a reference. Threaded fittings are limited to 50% of the rated pressure of the pipe.
Warning: Never use plastic pipe fittings and pipe with compressed air or gas.
For technical drawings and 3-D models, click on a part number.
- For Use With: Drinking Water, Water
- Maximum Temperature: 140° F
- Specifications Met: ASTM D1784, NSF/ANSI 61
- Pipe Nipples and Pipe: Use Schedule 40 Aluminum, Iron, PVC Plastic, Stainless Steel, Steel
- Flanges: Use Schedule 40 PVC Plastic
Saddle-tap tee adapters allow you to create additional outlets and connections in metal or plastic pipe. To install, shut down your line and drill a hole in the pipe where you want to create a connection. Position the saddle over the hole so the gasket and lip are fully engaged and secure with the included nuts, bolts, and washers.
Pipe Size | Socket Depth | For Pipe Size | For Pipe OD | For Hole Dia. | OD | ID | Wall Thick. | Material | Color | Max. Pressure | Each | |
1 1/2 | 1/2" | 4 | 4 1/2" | 1 3/4" | 1 29/32" | 1.61" | 0.145" | PVC Plastic | White | 200 psi @ 72° F | 0000000 | 0000000 |
1 1/2 | 29/32" | 3 | 3 1/2" | 2 1/4" | 1 29/32" | 1.61" | 0.145" | PVC Plastic | White | 200 psi @ 72° F | 0000000 | 00000 |
2 | 3/8" | 3 | 3 1/2" | 2 1/4" | 2 3/8" | 2.067" | 0.154" | PVC Plastic | White | 200 psi @ 72° F | 0000000 | 00000 |
2 | 7/16" | 4 | 4 1/2" | 2 1/4" | 2 3/8" | 2.067" | 0.154" | PVC Plastic | White | 200 psi @ 72° F | 0000000 | 000000 |
2 | 11/16" | 6 | 6 5/8" | 2 1/4" | 2 3/8" | 2.067" | 0.154" | PVC Plastic | White | 200 psi @ 72° F | 0000000 | 000000 |
3 | 1/2" | 4 | 4 1/2" | 3" | 3 1/2" | 3.068" | 0.216" | PVC Plastic | White | 200 psi @ 72° F | 0000000 | 000000 |
- For Use With: Drinking Water, Water
- Maximum Temperature: 140° F
- Specifications Met: ASTM D1784, NSF/ANSI 61
- Pipe Nipples and Pipe: Use Schedule 40 Aluminum, Iron, PVC Plastic, Stainless Steel, Steel
- Flanges: Use Schedule 40 PVC Plastic
Fittings with stainless steel collar have a reinforcement on the female threads to prevent the threads from cracking.
Saddle-tap tee adapters allow you to create additional outlets and connections in metal or plastic pipe. To install, shut down your line and drill a hole in the pipe where you want to create a connection. Position the saddle over the hole so the gasket and lip are fully engaged and secure with the included nuts, bolts, and washers.
Pipe Size | Socket Depth | For Pipe Size | For Pipe OD | For Hole Dia. | OD | ID | Wall Thick. | Material | Collar Material | Color | Max. Pressure | Each | |
NPT Threads | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1/2 | 5/16" | 2 | 2 3/8" | 3/4" | 27/32" | 0.622" | 0.109" | PVC Plastic | Stainless Steel | White | 200 psi @ 72° F | 0000000 | 000000 |
3/4 | 5/16" | 2 | 2 3/8" | 7/8" | 1 3/64" | 0.824" | 0.113" | PVC Plastic | Stainless Steel | White | 200 psi @ 72° F | 0000000 | 00000 |
3/4 | 27/32" | 4 | 4 1/2" | 1 1/8" | 1 3/64" | 0.824" | 0.113" | PVC Plastic | Stainless Steel | White | 200 psi @ 72° F | 0000000 | 000000 |
1 | 5/16" | 2 | 2 3/8" | 1 1/8" | 1 5/16" | 1.049" | 0.133" | PVC Plastic | Stainless Steel | White | 200 psi @ 72° F | 0000000 | 00000 |
1 | 7/16" | 4 | 4 1/2" | 1 1/8" | 1 5/16" | 1.049" | 0.133" | PVC Plastic | Stainless Steel | White | 200 psi @ 72° F | 0000000 | 000000 |
2 | 11/16" | 6 | 6 5/8" | 2 1/4" | 2 3/8" | 2.067" | 0.154" | PVC Plastic | Stainless Steel | White | 200 psi @ 72° F | 0000000 | 000000 |
- For Use With: Drinking Water, Water
- Maximum Temperature: 140° F
- Specifications Met: ASTM D1784, NSF/ANSI 61
- Pipe Nipples and Pipe: Use Schedule 40 PVC Plastic
- Flanges: Use Schedule 40 PVC Plastic
Tee outlet adapters allow you to create additional outlets and connections in plastic pipe. Use a PVC primer and cement to secure the tee outlet into position, then drill a hole through the fitting and pipe. They are also known as branch connectors.
Pipe Size | For Pipe Size | Material | Color | Each | |
NPT Threads | |||||
---|---|---|---|---|---|
1/8 | 1/2 | PVC Plastic | White | 00000000 | 00000 |
1/8 | 3/4 | PVC Plastic | White | 00000000 | 0000 |
1/2 | 1/2 | PVC Plastic | White | 00000000 | 0000 |
1/2 | 1 | PVC Plastic | White | 00000000 | 0000 |
1/2 | 3/4 | PVC Plastic | White | 00000000 | 0000 |
3/4 | 1 | PVC Plastic | White | 00000000 | 0000 |
3/4 | 3/4 | PVC Plastic | White | 00000000 | 0000 |
1 | 1 | PVC Plastic | White | 00000000 | 0000 |
Thick-Wall Plastic Pipe Fittings for Water
Connect these fittings to Schedule 80 pipe–they have thicker, stronger walls than standard-wall fittings so they can handle heavy duty industrial plumbing and water supply applications, such as water processing, waste water treatment, and irrigation. Fittings are plastic for good corrosion resistance. They meet ASTM specifications and testing requirements for material quality.
Fittings for drinking water meet NSF/ANSI Standard 61.
To prevent leaks in threaded connections, apply a sealant to the male threads. For plastic threads, apply a non-hardening, plastic-compatible sealant. Tape or sealants with PTFE are not recommended for plastic-to-plastic connections.
Note: For fittings that are not rated for pressure, you can use the pressure rating of the plastic pipe as a reference. Threaded fittings are limited to 50% of the rated pressure of the pipe.
Warning: Never use plastic pipe fittings and pipe with compressed air or gas.
For technical drawings and 3-D models, click on a part number.
- For Use With: Drinking Water, Water
- Maximum Temperature: 140° F
- Specifications Met: ASTM D1784, NSF/ANSI 61
- Pipe Nipples and Pipe: Use Schedule 80 Aluminum, Iron, PVC Plastic, Stainless Steel, Steel
- Flanges: Use Class 150 PVC Plastic
Saddle-tap tee adapters allow you to create additional outlets and connections in metal or plastic pipe. To install, shut down your line and drill a hole in the pipe where you want to create a connection. Position the saddle over the hole so the gasket and lip are fully engaged and secure with the included nuts, bolts, and washers.
Pipe Size | For Pipe Size | For Pipe OD | For Hole Dia. | Material | Collar Material | Color | Max. Pressure | Each | |
NPT Threads | |||||||||
---|---|---|---|---|---|---|---|---|---|
1/2 | 2 | 2 3/8" | 3/4" | PVC Plastic | Stainless Steel | Dark Gray | 200 psi @ 72° F | 0000000 | 000000 |
1/2 | 3 | 3 1/2" | 7/8" | PVC Plastic | Stainless Steel | Dark Gray | 200 psi @ 72° F | 0000000 | 00000 |
1/2 | 4 | 4 1/2" | 1 1/8" | PVC Plastic | Stainless Steel | Dark Gray | 200 psi @ 72° F | 0000000 | 000000 |
3/4 | 2 | 2 3/8" | 7/8" | PVC Plastic | Stainless Steel | Dark Gray | 200 psi @ 72° F | 0000000 | 00000 |
3/4 | 3 | 3 1/2" | 7/8" | PVC Plastic | Stainless Steel | Dark Gray | 200 psi @ 72° F | 0000000 | 00000 |
3/4 | 4 | 4 1/2" | 1 1/8" | PVC Plastic | Stainless Steel | Dark Gray | 200 psi @ 72° F | 0000000 | 000000 |
1 | 2 | 2 3/8" | 1 1/8" | PVC Plastic | Stainless Steel | Dark Gray | 200 psi @ 72° F | 0000000 | 00000 |
1 | 3 | 3 1/2" | 1 1/8" | PVC Plastic | Stainless Steel | Dark Gray | 200 psi @ 72° F | 0000000 | 00000 |
1 | 4 | 4 1/2" | 1 1/8" | PVC Plastic | Stainless Steel | Dark Gray | 200 psi @ 72° F | 0000000 | 000000 |
1 1/2 | 3 | 3 1/2" | 2 1/4" | PVC Plastic | Stainless Steel | Dark Gray | 200 psi @ 72° F | 0000000 | 00000 |
1 1/2 | 4 | 4 1/2" | 1 3/4" | PVC Plastic | Stainless Steel | Dark Gray | 200 psi @ 72° F | 0000000 | 000000 |
2 | 4 | 4 1/2" | 2 1/4" | PVC Plastic | Stainless Steel | Dark Gray | 200 psi @ 72° F | 0000000 | 000000 |
2 | 6 | 6 5/8" | 2 1/4" | PVC Plastic | Stainless Steel | Dark Gray | 200 psi @ 72° F | 0000000 | 000000 |
CPVC Pipe Fittings for Hot Water
Made of CPVC, these fittings can handle high temperatures. They have thick, strong walls to handle heavy duty industrial plumbing and water supply applications, such as water processing and waste water treatment. They also have good corrosion resistance. These fittings are comparable to Corzan. Some meet ASTM D1784 specifications and testing requirements for material quality.
Fittings for drinking water meet NSF/ANSI Standard 61.
Schedule 80 fittings have thick, strong walls for heavy duty, industrial applications.
Warning: Never use plastic pipe fittings and pipe with compressed air or gas.
For technical drawings and 3-D models, click on a part number.
- For Use With: Acetic Acid (10%), Calcium Chloride, Deionized Water, Drinking Water, Hydrochloric Acid (25%), Nitric Acid (10%), Phosphoric Acid (85%), Salt Water, Sodium Hydroxide (50%), Sulfuric Acid (75%), Water
- Maximum Temperature: 200° F
- Specifications Met: ASTM D1784, NSF/ANSI 61
- Pipe Nipples and Pipe: Use Schedule 80 CPVC Plastic
- Flanges: Use Class 150 CPVC Plastic
To prevent leaks in threaded connections, apply a non-hardening, plastic-compatible sealant to the male threads. Tape or sealants with PTFE are not recommended for plastic-to-plastic threaded connections. When making a threaded connection be careful not to overtighten the threads. To prevent cracks and leaks, finger tighten the fitting, then wrench-tighten one to two turns.
Saddle-tap tees allow you to create additional outlets and connections in metal or plastic pipe. They clamp on for an easy way to install and maintain systems.
Pipe Size | For Pipe Size | For Pipe OD | For Hole Dia. | Material | Schedule | Color | Max. Pressure | Each | |
NPT Threads | |||||||||
---|---|---|---|---|---|---|---|---|---|
1/2 | 2 | 2 3/8" | 3/4" | CPVC Plastic | 80 | Light Gray | 230 psi @ 72° F | 00000000 | 000000 |
1/2 | 3 | 3 1/2" | 7/8" | CPVC Plastic | 80 | Light Gray | 230 psi @ 72° F | 00000000 | 00000 |
1/2 | 4 | 4 1/2" | 1 1/8" | CPVC Plastic | 80 | Light Gray | 230 psi @ 72° F | 00000000 | 000000 |
3/4 | 2 | 2 3/8" | 7/8" | CPVC Plastic | 80 | Light Gray | 230 psi @ 72° F | 00000000 | 00000 |
3/4 | 3 | 3 1/2" | 7/8" | CPVC Plastic | 80 | Light Gray | 230 psi @ 72° F | 00000000 | 00000 |
3/4 | 4 | 4 1/2" | 1 1/8" | CPVC Plastic | 80 | Light Gray | 230 psi @ 72° F | 00000000 | 000000 |
1 | 2 | 2 3/8" | 1 1/8" | CPVC Plastic | 80 | Light Gray | 230 psi @ 72° F | 00000000 | 00000 |
1 | 3 | 3 1/2" | 1 1/8" | CPVC Plastic | 80 | Light Gray | 230 psi @ 72° F | 00000000 | 00000 |
1 | 4 | 4 1/2" | 1 1/8" | CPVC Plastic | 80 | Light Gray | 230 psi @ 72° F | 00000000 | 000000 |
1 1/2 | 3 | 3 1/2" | 2 1/4" | CPVC Plastic | 80 | Light Gray | 230 psi @ 72° F | 00000000 | 00000 |
1 1/2 | 4 | 4 1/2" | 1 3/4" | CPVC Plastic | 80 | Light Gray | 230 psi @ 72° F | 00000000 | 000000 |
2 | 4 | 4 1/2" | 2 1/4" | CPVC Plastic | 80 | Light Gray | 230 psi @ 72° F | 00000000 | 000000 |
2 | 6 | 6 5/8" | 2 1/4" | CPVC Plastic | 80 | Light Gray | 200 psi @ 72° F | 00000000 | 000000 |
Low-Pressure Clamp-On Connectors for Drain, Waste, and Vent
To make installing and maintaining systems easy, these connectors come with clamps that form a strong seal on pipe and fittings once tightened.
Saddle-tap adapters allow you to tap into an existing pipeline. They have wraparound clamps that provide nearly 360° contact with pipe; as the clamps are tightened, pressure is uniformly distributed around the pipe for maximum support. To install, shut down your line and drill a hole in the pipe where you want to create a connection. Position the saddle over the hole and tighten the clamps.
For technical drawings and 3-D models, click on a part number.
- For Use With: Air, Water
- Temperature Range: 0° to 110° F
- For Pipe Material: PVC Plastic
- For Use With: Air, Water
- Temperature Range: 0° to 110° F
- For Pipe Material: PVC Plastic