Extended-Life Immersion Circulation Pumps for Water and Coolants
A sealless construction means these pumps have few moving parts that can fail and shorten service life. The intake can be completely submerged in liquid. Pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. They are gravity fed and require an elevated liquid source. Do not run dry.
12V DC pumps must be fully submerged in liquid to run.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Intake | Discharge | Overall | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Flow Rate @ 10 ft. of Head, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Electrical Connection Type | hp | Current | Pipe Size | Gender | Thread Type | Pipe Size | Gender | Thread Type | Lg. | Wd. | Ht. | Each | |
12V DC—Without Thermal Overload Protection | |||||||||||||||||||
2.7 | 0.5 | 11 | 50 | 5 | 32° to 120° | Hardwire | Subfractional | 0.9A | 1/4 | Male | NPT | 1/4 | Male | NPT | 4 15/16" | 2 1/4" | 3 1/4" | 0000000 | 0000000 |
Any-Direction Constant-Flow-Rate Pumps for Water
Mount these pumps in any position, even upside down. Pumps have a subfractional horsepower motor rated for intermittent use (return to room temperature before restarting). Also known as diaphragm pumps, they are for use in low-flow spraying, draining, and washdown applications. They are self-priming, which means they create a suction force to draw liquid upward. Pumps can run dry and do not require an initial fill, so they’re a good choice for applications without a constant flow of liquid. Do not use with solids.
Battery-operated pumps operate on a 12-volt battery. They are commonly used with agricultural sprayers and washers.
Pumps with a pressure switch automatically shut off the pump at the maximum pressure.
For technical drawings and 3-D models, click on a part number.
Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Flow Rate @ Pressure | Max. ft. of Head | Max. Pressure, psi | Max. Temp., °F | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Max. Self-Priming Ht., ft. | Lg. | Wd. | Ht. | Each | ||
12V DC—With Thermal Overload Protection and With Pressure Switch | ||||||||||||||||||
Hardwire | ||||||||||||||||||
B | 5.3 | 4.30 gpm @ 20 psi (46 ft. of head), 3.40 gpm @ 60 psi (138 ft. of head) | 120 | 60 | 140° | 17 | 1/2 | NPSM | Male | 1/2 | NPSM | Male | 8 | 10" | 4 15/16" | 4" | 0000000 | 0000000 |
12V DC—Without Thermal Overload Protection and With Pressure Switch | ||||||||||||||||||
Hardwire | ||||||||||||||||||
A | 1.8 | 1.45 gpm @ 20 psi (46 ft. of head), 1.22 gpm @ 60 psi (138 ft. of head) | 231 | 100 | 170° | 8.7 | 3/8 | NPT | Female | 3/8 | NPT | Female | 10 | 8 3/8" | 4" | 4 1/8" | 0000000 | 000000 |
A | 1.8 | 1.57 gpm @ 20 psi (46 ft. of head), 1.23 gpm @ 60 psi (138 ft. of head) | 138 | 60 | 170° | 7.2 | 3/8 | NPT | Female | 3/8 | NPT | Female | 12 | 8 3/8" | 4" | 4 1/8" | 0000000 | 000000 |
A | 3 | 2.69 gpm @ 20 psi (46 ft. of head) | 115 | 50 | 170° | 8 | 1/2 | NPSM | Male | 1/2 | NPSM | Male | 8 | 8 5/8" | 5" | 4 1/2" | 0000000 | 000000 |
A | 3.5 | 2.56 gpm @ 20 psi (46 ft. of head) | 115 | 50 | 130° | 9.9 | 1/2 | NPSM | Male | 1/2 | NPSM | Male | 9 | 8 5/8" | 5" | 4 1/2" | 0000000 | 000000 |
Harsh-Environment Compact Constant-Flow-Rate Pumps for Water and Oil
An aluminum enclosure around the motor provides protection in dusty and dirty environments. Designed to fit into small equipment, these pumps have miniature gears and a subfractional horsepower motor for low-flow applications. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Intake | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | hp | Current, A | Tube Connection Type | Gender | For Tube ID | Tube Connection Type | Gender | For Tube ID | Lg. | Wd. | Ht. | Each | |
12V DC—Without Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
0.61 gpm (78 oz./min.) | 20 | 800 | 10° to 180° | Subfractional | 2.2 | Barbed | Male | 3/16" | Barbed | Male | 3/16" | 4" | 1 3/4" | 2 1/2" | 0000000 | 000000 |
Portable Battery-Operated Drum Pumps for Diesel Fuel
For on-site diesel fuel dispensing at construction sites, on boats, and in other environments without electrical hookups, attach these portable pumps to any 12-volt battery.
Temp. Range, °F | Intake | Discharge | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | Includes | Hose Connection Type | For Hose ID | Hose Connection Type | For Hose ID | Features | Each | |
12V DC, Single Phase | |||||||||||||||
13 | 21 | 5.3 | 25° | 100° | Not Rated | 18 | 6 | 6 1/2-ft. Battery Cable with Clamps | Barbed | 3/4" | Barbed | 3/4" | Bypass Relief Valve | 00000000 | 0000000 |
Portable Battery-Operated Drum Pumps with Nozzle for Diesel Fuel
A nozzle and hose allow you to dispense directly into your container. For on-site diesel fuel dispensing at construction sites, on boats, and in other environments without electrical hookups, attach these portable pumps to any 12-volt battery.
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | Includes | Hose Connection Type | For Hose ID | ID | Lg., ft. | Features | Each | |
12V DC, Single Phase | |||||||||||||||
13 | 14 | 5.3 | 25° | 100° | Not Rated | 22 | 6 | 6 1/2-ft. Battery Cable with Clamps | Barbed | 3/4" | 3/4" | 13 | Bypass Relief Valve | 00000000 | 0000000 |
Battery-Operated Drum Pumps with Nozzle for Fuel
Operating on a 12-volt battery, these pumps transfer and drain fuel such as gasoline, diesel fuel, and kerosene. Lock the nozzle with a padlock (not included).
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Pumps with metering nozzle record total volume up to 99,999.9 gallons.
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | ID | Lg., ft. | Nozzle Type | Each | |
12V DC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
15 | 12 | 30 | -15° | 150° | 1/4 hp | 20 | 8 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1" | 20"-34 3/4" | 3/4" | 12 | Manual Shut-Off, Lockable | 0000000 | 0000000 |
15 | 12 | 30 | -15° | 150° | 1/4 hp | 20 | 8 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1" | 20"-34 3/4" | 3/4" | 12 | Metering, Manual Shut-Off | 0000000 | 000000 |
Hazardous Location High-Flow Battery-Operated Drum Pumps with Nozzle for Fuel
These pumps are C-UL listed for Class I, Division 2, Group D for use in environments with flammable gases. Operating on a 12-volt battery, use them to transfer and drain fuel such as gasoline, diesel fuel, and kerosene. Lock the nozzle with a padlock (not included).
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Pumps with automatic shut-off nozzle turn off when the tank is full.
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | ID | Lg., ft. | Nozzle Type | Max. Shackle Dia. | Thermal Protection | Each | |
12V DC | |||||||||||||||||||
25 | 20 | 10 | -20° | 125° | 4/10 hp | 35 | 15 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1 | Female | NPT | 1" | 18 | Automatic Shut-Off, Lockable | 5/16" | With Thermal Overload Protection | 0000000 | 000000000 |
25 | 20 | 10 | -20° | 125° | 4/10 hp | 35 | 15 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1 | Female | NPT | 1" | 18 | Manual Shut-Off, Lockable | 5/16" | With Thermal Overload Protection | 0000000 | 000000 |
Heavy Duty Battery-Operated Water-Removal Pumps
This pump has an impact-resistant aluminum housing and handles larger solids than other battery-operated water-removal pumps. Attach it to a 12-volt battery to remove water in locations without power. Pump is gravity fed and requires an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Discharge | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate @ 5 Ft. of Head, gpm | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Ht. | Each | |
12V DC—With Thermal Overload Protection | |||||||||||||
41 | 20 | 1/4" | 1/4" | 35° to 190° | 1/3 hp | 30 | 1 1/2 | NPT | Female | 9 37/64" | 22 3/64" | 000000 | 000000000 |
Compact Water-Removal Pumps
Also known as bilge pumps, these remove fresh and salt water from spots where other pumps don’t fit. They have an internal sensor, so they turn on when they detect water and turn off when the water is removed. Pumps are fully submersible. They are gravity fed and require an elevated liquid source to fully fill the pump before turning on.
Pumps for 12 volts DC work with 12-volt batteries.
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Sensor Time Interval | Horsepower | Current, A | For Tube ID | Gender | Dia. | Ht. | Each | |
ABS Plastic Housing | |||||||||||||
Hardwire with 2 ft. Cord | |||||||||||||
5 | 1 | 11 | 1/4" | 30° to 140° | 2.5 min. | Not Rated | 1.6 | 3/4" | Male | 3" | 4" | 0000000 | 000000 |
10 | 3 | 10 | 1/4" | 30° to 140° | 2.5 min. | Not Rated | 3.7 | 1", 1 1/8" | Male | 3" | 5" | 0000000 | 000000 |
Miniature Metering Pumps for Chemicals
With a footprint that's only a few inches in any direction, these pumps fit into compact systems to dispense small amounts of acids, cleaning fluids, and other chemicals. They're often used in sterilization, photochemical, and water treatment systems. Choose from pumps with either a 4-20mA or 1-5V DC input signal that controls the flow rate.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
External | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gal./day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Current, A | Signal | Voltage | For Intake Tube ID | For Discharge Tube ID | For Tube OD | Lg. | Wd. | Ht. | Each | |
12V DC—With Thermal Overload Protection | ||||||||||||||
Hardwire | ||||||||||||||
14 | 29 | 6 | 30° to 100° | 1.5 | __ | 1-5V DC | 1/8" | 1/8" | 1/4" | 4" | 2 1/2" | 3 5/8" | 000000 | 0000000 |
14 | 29 | 6 | 30° to 100° | 1.5 | 4-20mA | __ | 1/8" | 1/8" | 1/4" | 4" | 2 1/2" | 3 5/8" | 000000 | 000000 |
Syringe Pumps for Chemicals
Dispense precise amounts of fluid from a syringe. Commonly used in chemical and pharmaceutical research, fiber production, and equipment calibration, these pumps maintain a steady flow rate for accurate filling and measuring. Use the color touchscreen to set parameters such as flow rate, force, and volume; schedule start and stop times; and create and save custom operations. Pumps work with glass, plastic, and stainless steel syringes from 0.5 µl to 60 ml. Mount horizontally or vertically; the touchscreen rotates.
Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, ml/min. | Temp. Range, °F | Microstep Size | Step Angle | For Syringe Size | Lg. | Wd. | Ht. | Specifications Met | Features | Each | |
12V DC | |||||||||||
Plug | |||||||||||
88.3 | 40° to 100° | 0.063 | 0.9° | 0.5µL to 60ml | 9" | 7 1/2" | 5" | CE Marked; ETL Listed; UL Listed | LCD Display, RS-485 Port, USB Outlet | 0000000 | 000000000 |
Miniature Low-Flow Air Compressors/Vacuum Generators
These air compressors/vacuum generators are continuous duty and must be hardwired. They do not require lubricant and produce nonlubricated air.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Pressure, psi | Max. Flow Rate @ psi | Vacuum Rating, in. of Hg | Full Load Current | Vol., dBA | Lg. | Wd. | Ht. | For Tube ID | Lubricant Required | Electrical Connection Type | Each | |
12V DC | ||||||||||||
3 | 0.019 cfm @ 3 0.042 cfm @ 0 | 12 | 40 mA | 45 | 1 3/4" | 15/16" | 1 5/16" | 0.14" | No | Hardwire | 0000000 | 0000000 |
10 | 0.064 cfm @ 10 0.117 cfm @ 0 | 22 | 442 mA | 45 | 3 1/16" | 1 3/16" | 2 3/16" | 0.16" | No | Hardwire | 0000000 | 000000 |
12 | 0.148 cfm @ 12 0.254 cfm @ 0 | 25 | 2.3 A | 52 | 4 7/8" | 1 7/8" | 3 1/16" | 0.13" | No | Hardwire | 0000000 | 000000 |
Air Compressors with DC Motor
Get compressed air from a DC power source—these compressors can run on a 12-volt vehicle battery (not included) for use on trucks and heavy equipment, or a DC generator. Use them to inflate tires, clean filters, and operate light-duty tools, such as nailers, hammers, and small impact wrenches. For best results with a vehicle battery, use a deep-cycle, large-cell battery rated for continuous use.
Connector assemblies come with a three-foot hose and a connector that can be fixed to a panel or frame for operating compressors installed in difficult-to-reach locations, such as under a vehicle.
Compressor | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Outlet (Female) | Overall | |||||||||||
Max. Pressure, psi | Max. Flow Rate @ psi | hp | Full Load Current, A | Vol., dBA | Pipe Size | Thread Type | Lubricant Required | Lg. | Wd. | Ht. | Each | |
12V DC | ||||||||||||
200 | 7.9 cfm @ 200 8 cfm @ 100 9 cfm @ 75 | 2 1/5 | 180 | 83 | 3/8 | NPT | Yes | 21" | 7" | 11" | 0000000 | 000000000 |
Air Pumps
Pump with vehicle plug connects to a 12-volt vehicle outlet. Pump with spring clamps connects directly to a 12-volt vehicle battery.
Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Max. Pressure, psi | For Valve Type | Cord Lg. | Lg. | Wd. | Ht. | Air Hose Lg. | Includes | Housing Material | Each | |
Vehicle Battery Powered with Vehicle Plug | ||||||||||
12V DC | ||||||||||
60 | Schrader | 9 ft. | 9 1/4" | 3" | 5 1/2" | 3ft. | Pressure Gauge | Aluminum | 0000000 | 000000 |
Vehicle Battery Powered with Spring Clamps | ||||||||||
12V DC | ||||||||||
120 | Schrader | 9 ft. | 10" | 3" | 5 1/2" | 12ft. | Pressure Gauge | Aluminum | 0000000 | 00000 |