About Sump, Water-Removal, Condensate, and Submersible Pumps
More
How to Prime Your Pump
More
How to Determine Feet of Head
More
About Process Pumps
More
Low-Maintenance Plastic Circulation Pumps for Water and Coolants
Eliminate seal wear and leakage with pumps that use magnets to turn the impeller. They’re often used with electroplating and photographic solutions. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.

Flow Rate, gpm | Intake | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 10 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | hp | Current, A | Pipe Size | Gender | Thread Type | Pipe Size | Gender | Thread Type | Lg. | Wd. | Ht. | Each | |
115V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Plug | ||||||||||||||||||
9 | 5 | 16.1 | 7 | 20 | 35° to 150° | 1/20 hp | 1.4 | 1/2 | Female | NPT | 1/2 | Male | NPT | 8 7/8" | 3 3/4" | 4 7/8" | 0000000 | 0000000 |
Harsh-Environment Low-Maintenance Plastic
Circulation Pumps for Water and Coolants

These pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. The impeller is turned with magnets to eliminate seal wear and leakage for a long service life. Pumps are often used with electroplating and photographic solutions. They are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 5 ft. of Head | @ 10 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
10 | 7 | 5 | 16.3 | 7 | 20 | 1/20 | 0.8 | 1/2 | Female | 1/2 | Male | 8 1/2" | 4" | 4 3/8" | 0000000 | 0000000 |
Submersible Pumps for Salt Water

Circulate salt water in submerged and open-air applications. These pumps use magnets to turn the impellers so there is no shaft seal to wear out. They must be wired to a plug (not included) to activate. Do not run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
8.5 | 8 | 19 | 35° to 130° | 1/20 hp | 2 | 3/4 | NPT | Female | 1/2 | NPT | Male | 4 7/8" | 7 3/8" | 4 3/4" | 00000000 | 0000000 |
Condensate Pumps with Tank

Equipped with a built-in container for condensate, these pumps work alongside your system to remove condensate from air conditioners, refrigerators, dehumidifiers, and other equipment. They are not submersible. A safety switch turns off your equipment in case of pump failure. Pumps turn on and off automatically.
Hardwire pumps must be wired to a power source.
Style D pumps withstand higher temperatures than the other styles.

Max. Flow Rate, gpm | Level | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Electrical Connection Type | Tank Capacity, gal. | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Tube Connection Type | For Tube OD | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
D | Hardwire | 1 | 1.8 | 1.6 | 1.4 | 25 | 11 | 3 3/16" | 7/8" | 35° to 190° | 1/20 hp | 1.3 | Compression | 3/8" | 10 1/8" | 6" | 12" | 0000000 | 0000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
D | Hardwire | 1 | 1.8 | 1.6 | 1.4 | 25 | 11 | 3 3/16" | 7/8" | 35° to 190° | 1/20 hp | 0.9 | Compression | 3/8" | 10 1/8" | 6" | 12" | 0000000 | 000000 |