Panel-Mount Fixed-Flow-Rate Metering Pumps for Chemicals

Install these pumps in a panel cutout. Often used in food and beverage, pharmaceutical, and lab applications, they dispense small amounts of liquid at a set rate. Pumps can be wired to a switch for manual operation, or a PLC for automated equipment. The removable pump head includes an intake tube that quickly connects to your line with barbed fittings (not included). To change lines, disconnect tubing and twist and pull the head off the motor. Then twist on a replacement head (sold separately). Pumps come in three colors for easy identification or to match your existing equipment. All are self-priming and create suction to draw liquid upward. Mount pumps up to 28 ft. above your liquid source. They can run dry.
Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, ml/min. | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Wd. | Ht. | Dp. | Each | |
Blue | ||||||||||
24V DC | ||||||||||
Hardwire | ||||||||||
55 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 0000000 |
160 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
Clear | ||||||||||
24V DC | ||||||||||
Hardwire | ||||||||||
55 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
160 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
Green | ||||||||||
24V DC | ||||||||||
Hardwire | ||||||||||
55 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
160 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
Submersible Pumps for Water

Submerge these pumps to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.

Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
C | Plug | 3.5 | 2.5 | 10.2 | 35° to 120° | 1/150 hp | 1.1 | Screened | 1/4 | NPT | Male | 6 | 4 5/8" | 4 1/8" | 4 1/8" | 0000000 | 0000000 |
Impact-Resistant Submersible Pumps for Water

The durable epoxy-coated aluminum housing handles hard knocks in rough waters. Submerge these pumps to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Hardwire pumps must be wired to a plug (not included).
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | ||
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||
Hardwire | |||||||||||||||
A | 3.4 | 2 | 7.4 | 35° to 120° | 1/150 hp | 0.4 | Screened | 1/4 | NPT | Male | 4 1/4" | 4 1/8" | 4 1/8" | 0000000 | 0000000 |
Impact-Resistant Submersible/Open-Air Pumps for Water

Protected from impact by a durable epoxy-coated aluminum housing, these pumps can be submerged or connected remotely to a pipe in your line. Use to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Plug | |||||||||||||||||
A | 3.4 | 2 | 7.4 | 35° to 120° | 1/150 hp | 1.1 | 1/4 × 1/2 | NPT × NPT | Female × Male | 1/4 | NPT | Male | 4 1/8" | 4 1/8" | 4 5/8" | 0000000 | 0000000 |
Submersible Pumps for Chemicals

These pumps circulate solvent-based parts-washing solutions. Submerge in solutions that are UL classified as PJQU (flash point no lower than 100° F). Pumps must be wired to a plug (not included) to activate. Do not run dry. Not for use in heated parts washer applications.
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 3 Ft. of Head | @ 5 Ft. of Head | @ 7 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
B | 3.4 | 2.8 | 2 | 0.3 | 7.4 | 35° to 120° | 1/150 hp | 1.1 | Screened | 1/4 | NPT | Male | 4 1/4" | 4 5/8" | 4 1/8" | 0000000 | 0000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
B | 3.4 | 2.8 | 2 | 0.3 | 7.4 | 35° to 120° | 1/150 hp | 0.6 | Screened | 1/4 | NPT | Male | 4 1/4" | 4 5/8" | 4 1/8" | 0000000 | 000000 |
Condensate Pumps

Fully submersible, these pumps are designed for installation inside your condensate collection tank or drain pan. Use them to collect and remove condensate from air conditioners, refrigerators, dehumidifiers, and other equipment. They turn on and off automatically.
Max. Flow Rate, gpm | Level | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Discharge Pipe Size | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||
Plug | |||||||||||||||
3.4 | 2.4 | 10 | 4 | 1 3/4" | 1 1/4" | 35° to 120° | 1/150 hp | 1.1 | Screened | 1/4 NPT Male | 4 3/8" | 6 3/8" | 6 1/8" | 0000000 | 0000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||
Hardwire | |||||||||||||||
3.4 | 2.4 | 10 | 4 | 1 3/4" | 1 1/4" | 35° to 120° | 1/150 hp | 0.5 | Screened | 1/4 NPT Male | 4 3/8" | 6 3/8" | 6 1/8" | 0000000 | 000000 |
Flood Coolant Dispensers with Reservoir

These dispensers have a reservoir for recirculating coolant. They provide a constant flow of coolant, so they dissipate heat more efficiently than mist and droplet dispensers, making them suitable for cooling long machine cycles. Coolant strainers prevent debris from getting into the recirculated coolant.
Maximum flow rate and shut-off height are for water-soluble oil. Shut-off height is the maximum height to which the water-soluble oil can be pumped.
Nozzle | Reservoir | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., gal. | Max. Flow Rate | Max. Pressure, psi | Coolant Outlet Hose Lg. | Lg. | Type | Nozzle Material | O'all Ht. | Wd. | Dp. | Reservoir Material | Shut-Off Ht., ft. | For Max. SSU Viscosity Grade | Voltage | Features | Each | ||
For Use With Coolant, Water | |||||||||||||||||
B | 5 | 210 gph @ 1 ft. of head | 4.3 | 6 ft. | 12" | Flexible | Acetal Plastic | 8 1/2" | 16 7/8" | 11 1/4" | Polyethylene Plastic | 10.2 | 300 | 120V AC | Adjustable Flow, Coolant Strainer, Baffle, On/Off Valve | 00000000 | 0000000 |