How to Prime Your Pump
More
How to Determine Feet of Head
More
About Vacuum Pumps
More
About Process Pumps
More
About Drum Pumps
More
About Air Compressors
More
About Sump, Water-Removal, Condensate, and Submersible Pumps
More
Circulation Pumps for Water and Oil
These pumps can be used to move water and lubricating oil in boiler feed systems, cooling towers, and heat exchangers. The housing rotates for vertical or horizontal discharge. They have totally enclosed fan-cooled (TEFC) motors for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 10 ft. of Head | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | Motor Enclosure Type | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | |
120/230V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Hardwire | ||||||||||||||||||||
79 | 72 | 63 | 51 | 35 | 5 | 52 | 75 | 20 | Totally Enclosed Fan Cooled | 1 1/2 | 18/9 | 1 1/4 | Female | 1 | Female | 14 1/4" | 8 3/4" | 8 5/8" | 0000000 | 0000000 |
Replacement Seal Assembly | 00000000 | Each | 000000 |
Harsh-Environment Circulation Pumps for Water and Oil
The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Use these pumps to move water and lubricating oil in boiler feed systems, cooling towers, and heat exchangers. The housing rotates for vertical or horizontal discharge. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created, which allows the pump to draw liquid upward.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 10 ft. of Head | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | |
120/208-240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
100 | 91 | 79 | 66 | 48 | 7 | 52 | 75 | 20 | 1 1/2 | 16.6/9- 8.3 | 1 1/2 | Female | 1 1/2 | Female | 16 1/2" | 8 7/8" | 9 1/2" | 0000000 | 000000000 |
208-240/460V AC, Three Phase—Without Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
100 | 91 | 79 | 66 | 48 | 7 | 52 | 75 | 20 | 1 1/2 | 4.3- 4.2/2.2 | 1 1/2 | Female | 1 1/2 | Female | 16 3/8" | 8 7/8" | 9 1/2" | 0000000 | 00000000 |
Replacement Seal Assembly | 00000000 | Each | 000000 |
High-Head High-Efficiency Circulation Pumps for Water, Coolants, and Oil
Propel liquid higher and farther than standard high-efficiency circulation pumps. These pumps use less electricity to achieve the same flow rates as other circulation pumps. They have a totally enclosed fan cooled (TEFC) motor for use in dusty, dirty, and damp environments. Adjust the housing studs to make the discharge direction more vertical or horizontal. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids. They cannot be sold to the regions listed due to local energy efficiency requirements.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 70 ft. of Head | @ 80 ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Cannot Be Sold To | Each | |
208-240/460V AC, Three Phase | |||||||||||||||||
Hardwire | |||||||||||||||||
50 | 37 | 26 | 92 | 150 | 17 | 1 1/2 | 4.9- 4.6/2.3 | 1 1/4 | Female | 1 | Female | 16" | 7 7/8" | 9" | CA, Canada | 0000000 | 000000000 |
High-Head Circulation Pumps for Water, Coolants, and Oil
Propel liquid higher and farther than standard circulation pumps. They're commonly used with chillers, heat exchangers, and boiler feed systems. The motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | Impellers | ||||||||||||||||||||||
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 90 ft. of Head | @ 120 ft. of Head | @ 130 ft. of Head | @ 140 ft. of Head | @ 150 ft. of Head | @ 200 ft. of Head | @ 250 ft. of Head | @ 300 ft. of Head | @ 350 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | Each | ||
208-240/460V AC, Three Phase—Without Thermal Overload Protection | ||||||||||||||||||||||||||
Hardwire | ||||||||||||||||||||||||||
10 | 9 | 9 | 8 | 8 | 8 | 8 | 7 | 7 | 6 | 5 | 380 | 165 | 54 | 1 1/2 | 2.4; 4.6- 4.8 | 1 | Female | 1 | Female | 15 1/8" | 6 1/2" | 8 5/8" | 00000000 | 000000000 | 000000000 | 0000000 |
Maintenance Kits | 000000000 | Each | 0000000 |
Circulation Pumps for Water Sprinklers
These pumps have high flow rates for irrigation and landscaping. The open dripproof (ODP) motor is for use in clean, dry, and well-ventilated environments. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward. They can be mounted up to 25 ft. above your liquid source.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 40 ft. of Head | @ 50 ft. of Head | @ 60 ft. of Head | @ 70 ft. of Head | @ 80 ft. of Head | @ 90 ft. of Head | @ 100 ft. of Head | @ 110 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | |
120/240V AC, Single Phase | ||||||||||||||||||||||
Hardwire | ||||||||||||||||||||||
69 | 64 | 60 | 55 | 50 | 45 | 36 | 30 | 18 | 117 | 60 | 1 | 1 1/2 | 19.2/9.6 | 2 | Female | 1 1/2 | Female | 19 3/4" | 12 3/8" | 11 7/8" | 0000000 | 0000000 |
High-Flow Inline Circulation Pumps for Water
A high-horsepower motor handles four times the flow and twice the pressure of other inline circulation pumps. Install these pumps directly in your pipeline for applications such as hot-water circulation and hydronic heating and cooling. Mount horizontally or vertically. The motor cannot face downward; it’s cooled by the water being pumped. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Pumps | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake | Discharge | Overall | Required Pipe Connectors | ||||||||||||||
Max. Flow Rate, gpm | @ 30 ft. of Head | @ 40 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Thread Type | Pipe Size | Thread Type | Lg. | Wd. | Ht. | Each | Pair | ||
120/208-240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Hardwire | ||||||||||||||||||
150 | 122 | 90 | 46 | 145 | 1 | 1 1/2 | 17/9.5-8.6 | 2 | NPT | 2 | NPT | 9 3/4" | 14" | 20 1/2" | 0000000 | 000000000 | 0000000 | 0000000 |
208-240/460V AC, Three Phase—Without Thermal Overload Protection | ||||||||||||||||||
Hardwire | ||||||||||||||||||
150 | 122 | 90 | 46 | 145 | 1 | 1 1/2 | 4.7-4.6/2.3 | 2 | NPT | 2 | NPT | 8 1/2" | 14" | 17 3/8" | 0000000 | 00000000 | 0000000 | 000000 |
Self-Priming Circulation Pumps for Water and Coolants
Drain underground tanks and process wastewater with pumps that can be installed up to 20 ft. above your liquid source. They have an open dripproof (ODP) motor for use in clean, dry, and well-ventilated environments. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | Maintenance Kits | Impellers | ||||||||||||||||
Max. Flow Rate, gpm | @ 40 ft. of Head | @ 50 ft. of Head | @ 70 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | Each | Each | |||
120/240V AC, Single Phase— With Thermal Overload Protection | |||||||||||||||||||||
Hardwire | |||||||||||||||||||||
120 | __ | 65 | 42 | 93 | 75 | 1 | 1 1/2 | 22/11 | 1 1/2 | Female | 1 1/2 | Female | 18" | 7 3/8" | 10" | 00000000 | 0000000 | 00000000 | 000000 | 000000 | 00 |
150 | 77 | 64 | __ | 82 | 75 | 1 | 1 1/2 | 17/9 | 2 | Female | 2 | Female | 19 3/8" | 7 1/2" | 11 1/8" | 00000000 | 000000 | 000000 | 00 | 000000000 | 000000 |
240/460V AC, Three Phase— Without Thermal Overload Protection | |||||||||||||||||||||
Hardwire | |||||||||||||||||||||
120 | __ | 65 | 42 | 93 | 75 | 1 | 1 1/2 | 7/4 | 1 1/2 | Female | 1 1/2 | Female | 17 1/2" | 7 3/8" | 10" | 00000000 | 000000 | 000000 | 00 | 000000 | 00 |
150 | 77 | 64 | __ | 82 | 75 | 1 | 1 1/2 | 7/4 | 2 | Female | 2 | Female | 18 7/8" | 7 1/2" | 11 1/8" | 00000000 | 000000 | 000000 | 00 | 000000000 | 00000 |
Harsh-Environment Self-Priming Circulation Pumps for Water and Coolants
The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Install these pumps up to 20 ft. above your liquid source to drain underground tanks and process wastewater. They are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Pumps | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | Impellers | |||||||||||||||
Max. Flow Rate, gpm | @ 40 ft. of Head | @ 50 ft. of Head | @ 60 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | Each | ||
120/240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
82 | 53 | 40 | 23 | 70 | 75 | 1 | 1 1/2 | 18/9 | 1 1/4 | Female | 1 1/4 | Female | 18 1/2" | 8 7/8" | 7 1/4" | 00000000 | 0000000 | 000000000 | 000000 |
240/460V AC, Three Phase—Without Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
82 | 53 | 40 | 23 | 70 | 75 | 1 | 1 1/2 | 5/3 | 1 1/4 | Female | 1 1/4 | Female | 18 3/8" | 8 7/8" | 8 5/8" | 00000000 | 000000 | 000000000 | 00000 |
Stainless Steel Circulation Pumps for Chemicals
A 316 stainless steel housing sealed with fluoroelastomer resists mild chemicals and acids, such as coolant, oil, and phosphoric acid. These pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. They are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | Replacement Impellers | |||||||||||||||||
Max. Flow Rate, gpm | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Solids Dia. | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | Each | ||
240/460V AC, Three Phase—With Thermal Overload Protection | |||||||||||||||||||||
Hardwire | |||||||||||||||||||||
95 | 80 | 55 | 20 | __ | 49 | 100 | 3/16" | 50 | 1 1/2 | 3.9/2 | 1 1/2 | Female | 1 1/4 | Female | 16" | 9" | 8 3/4" | 0000000 | 000000000 | 0000000 | 0000000 |
110 | 100 | 80 | 58 | 28 | 70 | 100 | 3/32" | 50 | 1 1/2 | 3.9/2 | 1 1/2 | Female | 1 1/4 | Female | 16" | 9" | 8 3/4" | 0000000 | 00000000 | 0000000 | 000000 |
Maintenance Kit for Pumps with 3/16" or 3/32" Max. Solids Dia. | 0000000 | Each | 0000000 |
Self-Priming Stainless Steel Circulation Pumps for Chemicals
Self-priming up to 6 ft., these pumps have a stainless steel housing sealed with PTFE to resist chemicals such as ammonia and detergents as well as harsh solvents including methyl ethyl ketone (MEK). The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 30 ft. of Head | @ 40 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | ||
120/240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
2 | 100 | 65 | 45 | 50 | 75 | 20 | 1 1/2 | 18/9 | 1 1/2 | Female | 1 1/2 | Female | 16 1/2" | 8 3/4" | 9 1/2" | 0000000 | 000000000 |
240/460V AC, Three Phase—Without Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
4 | 100 | 65 | 45 | 50 | 75 | 20 | 1 1/2 | 5/3 | 1 1/2 | Female | 1 1/2 | Female | 16 1/4" | 8 3/4" | 9 1/2" | 0000000 | 00000000 |
Circulation Pumps for Food and Beverage
Commonly used in food, beverage, and dairy processing, these pumps are 3-A certified to meet sanitary design standards. They have quick-clamp intake and discharge connections to facilitate cleaning. The discharge connection rotates 360° for easy connection to your line. Motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Pumps | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (Female) | Discharge (Female) | Overall | Replacement Impellers | |||||||||||||
Max. Flow Rate, gpm | @ 50 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Tube Connection Type | For Tube OD | Tube Connection Type | For Tube OD | Lg. | Wd. | Ht. | Each | Each | ||
208-240/460V AC, Three Phase—Without Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
85 | 50 | 44 | 24 | 800 | 1 1/2 | 4-3.8/1.9 | Quick-Clamp | 1 1/2" | Quick Clamp | 1 1/2" | 16 1/4" | 6 1/2" | 7 1/4" | 00000000 | 000000000 | 0000000 | 0000000 |
Circulation Pumps for Fuel and Flammable Liquid
Pump fuel and flammable liquids, such as isopropyl alcohol and xylene. These pumps have an explosion-proof motor that is rated for environments where hazardous material is present. Maximum temperature is 250° F or the boiling point of the liquid being pumped, whichever is lower. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Pumps | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Pipe Size | Overall | Replacement Impellers | ||||||||||||||
Max. Flow Rate, gpm | @ 30 ft. of Head | @ 40 ft. of Head | @ 60 ft. of Head, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Intake (Female, NPT) | Discharge (Female, NPT) | Lg. | Wd. | Ht. | Each | Each | ||
208-240/460V AC, Three Phase—Hardwire | |||||||||||||||||
115 | 100 | 90 | 60 | 81 | 150 | 264 | 1 1/2 | 5-4.6/2.3 | 1 1/2 | 1 | 16 3/8" | 11 7/8" | 8 1/2" | 0000000 | 000000000 | 00000000 | 0000000 |
Maintenance Kit | 00000000 | Each | 0000000 |
Circulation Pumps for Hot Oil
Transfer hot oil up to 650° F in demanding applications such as plastic mold injecting and chemical processing. These pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. They are gravity fed and require an elevated liquid source. Do not run dry or use with solids. They cannot be sold to the regions listed due to local energy efficiency requirements.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 60 ft. of Head | @ 70 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | Max. Temp., °F | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Cannot Be Sold To | Each | |
240/460V AC, Three Phase—Without Thermal Overload Protection | ||||||||||||||||||
Hardwire | ||||||||||||||||||
66 | 55 | 43 | 80 | 150 | 32 | 650° | 1 1/2 | 4.6/2.3 | 1 1/2 | Female | 1 1/4 | Female | 20" | 9" | 10" | CA, Canada | 0000000 | 000000000 |
Constant-Flow-Rate Pumps for Water
Also known as gear pumps, these produce a smooth flow of liquid for applications such as cooling engines, powering hydraulic equipment, and extracting liquid from holding tanks. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward. Do not use with solids. Pumps can be used in dusty, dirty, and damp environments.
Pumps that cannot be sold to Canada are restricted by local energy efficiency requirements.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Intake (NPT) | Discharge (NPT) | Overall | Chemical Resistance | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Motor Enclosure Type | Lg. | Wd. | Ht. | Cannot Be Sold To | Each | |
230/460V AC, Three Phase—Without Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
10.2 | 150 | 100,000 | 32° to 140° | 1 1/2 | 4.4/2.2 | 1/2 | Female | 1/2 | Female | Totally Enclosed Fan Cooled | 19 13/16" | 9 5/16" | 7 1/4" | Canada | 0000000 | 000000000 |
Sanitary Electric Drum Pumps
Commonly used in food, beverage, pharmaceutical, and cosmetic processing, these pumps are designed for sanitary environments. The discharge connection can be easily disassembled for cleaning. Pumps do not include a drum connector.
Pumps with a maximum viscosity of 100,000 cP handle a wide range of liquid thicknesses from water up to lotions and pie fillings.
For technical drawings and 3-D models, click on a part number.
Temp. Range, °F | Intake | Discharge | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | For Drum Opening Size, mm | Tube OD | Tube Lg. | Tube Connection Type | For Tube OD | Thermal Protection | Each | |
190V AC, 380V AC, 230V AC, 460V AC; Three Phase—Hardwire | |||||||||||||||
Aluminum Housing | |||||||||||||||
7 | 87 | 55 | 100,000 | 15° | 300° | 1 1/2 hp | 6.4, 3.2, 5.8, 2.9 | 50 | 2" | 39" | Quick Clamp | 1 1/2" | Without Thermal Overload Protection | 0000000 | 0000000000 |
Energy-Efficient Sump Pumps for Sewage Water
These pumps have a heavy duty motor with sealed bearings that generates a flow rate similar to our other sump pumps for sewage water while using fewer amps. Use them to transfer raw sewage water with solids up to 2" in diameter. The float switch is wired to the pump. Submerge while in use and do not run dry.
Pump with wire leads can be connected to a three-pronged plug or wired directly to a power source.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | O'all | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Feet of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Hardwire with 25 ft. Cord and Wire Leads | ||||||||||||||||||||
139 | 124 | 106 | 100 | 33 | 2" | 29" | 15" | 35° to 100° | 1 1/2 hp | 6.4 | 2 | NPT | Female | 24" | 28 1/8" | 21" | 9" | 8" | 00000000 | 000000000 |
Portable Sewage Water-Removal Pumps
Transfer raw sewage water that contains solids up to 2” in diameter. These pumps have a float switch with a separate cord that can unplug, so you can replace the switch without replacing the whole pump. The length of the float switch cord is adjustable. Turn-on and turn-off levels will vary according to the length of the cord. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Pumps with male discharge port have a horizontal discharge.
Pumps with female discharge port have a vertical discharge.
Max. Flow Rate, gpm | Level | Discharge (NPT) | Min. Sump Pit | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Gender | Dia. | Dp. | Dia. | Ht. | Wd. | Each | |
240V AC, Single Phase | |||||||||||||||||||
Hardwire with 25 ft. Cord | |||||||||||||||||||
__ | 114 | 79 | 46 | 2" | 5 1/2" | 20"-22" | 4"-12" | 35° to 100° | 1 1/2 hp | 8.4 | 2 | Male | 22" | 24" | __ | 19" | 10" | 0000000 | 000000000 |
134 | 114 | 77 | 41 | 2" | 5 1/2" | 20"-22" | 4"-12" | 35° to 130° | 1 1/2 hp | 8.4 | 2 | Female | 22" | 24" | 10" | 18" | __ | 0000000 | 00000000 |
High-Head Submersible Pumps for Water
Also known as deep-well submersible pumps, use these pumps to transfer drinking water from wells and cisterns up to 250 ft. deep. They are activated by a pressure switch and must be hardwired. Do not run dry.
For technical drawings and 3-D models, click on a part number.
Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Ft. of Head, ft. | Removes Water Down To, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Ht. | Specifications Met | Each | |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||
Hardwire | ||||||||||||||
16.4 | 223.5 | 250 | 68° to 104° | 1 1/2 hp | 13.1 | Screened | 1 1/2 | NPT | Female | 3 15/16" | 27 3/16" | NSF/ANSI 61, UL Listed | 0000000 | 000000000 |
Oil-Free Electric Vacuum Pumps
Since these pumps don't require lubrication, there’s no risk of oil contamination. Maximum flow rate is the rate at which air is pumped before a vacuum is created. Flow rate steadily decreases as the pump generates the vacuum. The larger the tank, the longer it will take to form a vacuum.
Style C pumps withstand harsh operating conditions. Use to service machinery and refrigeration and circulation systems.
Intake | Discharge | O'all | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Max. Vacuum, in. of Hg | Max. Flow Rate, cfm | Temp. Range, °F | Volume, dBA | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Lg. | Wd. | Ht. | Each | |
Hardwire | |||||||||||||||||
C | 27.5 | 10.5 | 35° to 100° | 75 | 1 1/2 hp | 10/21 | 1/4 | NPT | Female | 1/4 | NPT | Female | 21" | 12 1/4" | 8 1/2" | 000000 | 000000000 |
Pumps for Hydraulic Jacks
Connect these pumps to a ram to create a hydraulic jack. Use hose to connect; add a pressure gauge to monitor hydraulic oil pressure levels and guard against overload.
Style 7 and 8 pumps operate from up to 10 ft. away using the included wired remote.
Pumps with two-speeds are quick to pump until the load is engaged, then pump more slowly for precise positioning.
Warning: Never use to support people or loads over people.
For technical drawings and 3-D models, click on a part number.
Pump | Mounting | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Working Orientation | Oil Capacity, cu. in. | No. of Speeds | Lg. | Wd. | Ht. | Max. Pressure, psi | Pipe Size | Thread Type | Gender | Material | Fasteners Included | No. of Holes | Hole Dia. | Plug Type | Includes | Each | |
Electric | ||||||||||||||||||
8 | Vertical | 590 | 2 | 11 1/2" | 9 1/2" | 19 5/8" | 10,000 | 3/8 | NPTF | Female | Aluminum, Steel | No | 4 | 1/2" | NEMA 5-20 | Remote Control with 10-ft. Cord | 0000000 | 000000000 |
Fire Sprinkler Air Compressors
Pressurize air for sprinkler systems. These compressors turn on when the tank falls to the activation pressure and they turn off when the tank reaches the maximum pressure. UL and C-UL listed, as well as CSA and CSA-US certified, they meet U.S. and Canadian safety standards.
For technical drawings and 3-D models, click on a part number.
Air Compressors | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure, psi | Outlet | Overall | Replacement Drive Belts | |||||||||||||
Maximum | Actuation | Maximum Flow Rate | hp | Full Load Current, A | Tank Capacity, gal. | Volume, dB | Pipe Size | Thread Type | Gender | Length | Width | Height | Each | Each | ||
Single Phase, 120V AC/230V AC | ||||||||||||||||
40 | 30 | 10.9 cfm @ 40 psi | 1 1/2 | 15.8 | 30 | 77 | 1/2 | NPT | Female | 39" | 16 1/2" | 34 1/4" | 00000000 | 000000000 | 00000000 | 000000 |