Metering Pumps for Chemicals
An adjustment screw lets you increase or decrease flow rate without the hassle of changing tubing. Often used in boiler feed systems and water treatment, these pumps are compatible with chemicals such as cleaning fluids and acid-washing solutions. Pumps are self-priming and create suction to draw liquid upward. They can run dry.
Pumps | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube | Overall | Replacement Collars | Replacement Tubing | ||||||||||||||
Flow Rate, gal./day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | ID | OD | Lg. | Wd. | Ht. | Includes | Each | Each | Each | |||
120V AC, Single Phase | |||||||||||||||||
Plug | |||||||||||||||||
2-12 | 25 | 200 | 35° to 100° | 1/64 hp | 0.3 | 3/16" | 3/8" | 8" | 7" | 6" | 9" Lg. of Tygon Tubing (Shore A70) | 00000000 | 0000000 | 00000000 | 000000 | 00000000 | 000000 |
3-20 | 25 | 200 | 35° to 100° | 1/64 hp | 0.3 | 1/4" | 7/16" | 8" | 7" | 6" | 9" Lg. of Tygon Tubing (Shore A70) | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 00000 |
Replacement Pump Head | 00000000 | Each | 000000 |