Inlet | Internal Outlet Connection | External Outlet Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Thread Size | Thread Type | Gender | For Valve Type | CGA Number | Gender | Thread Size | Thread Type | Gender | Cable Lg. | Each | |
1 5/16"-5 | Acme | Female | POL/Acme (Type 1) | CGA 510 | Female | 1 5/16"-5 | Acme | Male | 30" | 0000000 | 000000 |
Distance-Measuring Modules for Development Boards
Stream distance readings to your development board in real time. Set up these modules near your robotics, production lines, or liquid monitoring systems to capture changing positioning.
Ultrasonic modules use sound pulses to measure distance. They can be used in low lighting. However, they may not be accurate on soft, small, or oddly shaped objects that won’t reflect sound waves properly.
Infrared LED modules bounce light off an object and back into their own sensor to measure distance. Those with a Qwiic connection are easily installed using Qwiic cords.
Laser modules quickly and accurately detect objects up to 40 meters away. Choose them to measure the distance of fast-moving objects.
Modules with I2C protocol make setup and data collection simple. They convert readings into an electrical signal to transmit to your board.
Sensing Distance | Accuracy | Output Data Frequency, Hz | Input Voltage | Lg. | Wd. | Ht. | Each | |
2 cm-4 m | ±0.3 cm | 40 | 5V DC | 1 3/4" | 3/4" | 1/2" | 0000000 | 00000 |
Output Data | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensing Distance | Resolution | Accuracy | Resolution, bit | Frequency, Hz | Input Voltage | Communication Protocol | I2C Address | Connection Type | No. of Qwiic Connections | No. of Wire Leads | Wire Lead Lg. | Lg. | Wd. | Ht. | Each | |
4 cm-30 cm | __ | __ | __ | 50 | 4.5-5.5V DC | __ | __ | Wire Leads | __ | 3 | 5" | 1 3/4" | 3/4" | 9/16" | 0000000 | 000000 |
10 cm-80 cm | __ | __ | __ | 20 | 4.5-5.5V DC | __ | __ | Wire Leads | __ | 3 | 5" | 1 3/4" | 3/4" | 9/16" | 0000000 | 00000 |
5 cm-10 m | 1 cm | ±1 cm | 7 | 200 | 3.3V DC | I2C | 0x62 | Qwiic | 2 | __ | __ | 2 5/16" | 1" | 7/8" | 0000000 | 00000 |
Output Data | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensing Distance | Resolution | Accuracy | Resolution | Frequency | Input Voltage | Communication Protocol | I2C Address | Connection Type | No. of Wire Leads | Wire Lead Lg. | Lg. | Wd. | Ht. | Environmental Rating | Each | |
1 m-40 m | 1 cm | ±2.5 cm | 7 bit | 1 kHz | 4.75-5V DC | I2C | 0x62 | Wire Leads | 6 | 7 3/4" | 2 1/8" | 1" | 1 5/16" | IP07 | 0000000 | 0000000 |