Digital High-Accuracy Pressure Gauges
With Bottom
Connection
A four-digit LCD display allows for easy reading of measurements. The LCD shuts off automatically to extend battery life. Gauges are commonly used with pneumatic regulators, compressors, and in critical processes that require high accuracy, such as hydraulic and laboratory applications.
For technical drawings and 3-D models, click on a part number.
- For Use With: Air, Carbon Dioxide, Hydrogen, Nitrogen, Natural Gas
- Accuracy: ±1% Full Scale (Grade 1A)
Available Pressure Ranges | ||||
---|---|---|---|---|
Pressure Range | ||||
psi | bar | kg/cm2 | MPa | Resolution, psi |
0 to 145 | 0 to 10 | 0 to 10 | 0 to 1 | 0.1 |
Center Back Connection | ||||||||
---|---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Batteries Included | Mounting Orientation | Features | Each | |
NPT Male | ||||||||
1 3/4" | 1/8 | -10° to 140° | -10° to 140° | Yes | Any | 5-min. Automatic Shut-Off | 000000 | 000000 |
1 3/4" | 1/4 | -10° to 140° | -10° to 140° | Yes | Any | 5-min. Automatic Shut-Off | 000000 | 00000 |
NPT Male with Calibration Certificate Traceable to NIST | ||||||||
1 3/4" | 1/8 | -10° to 140° | -10° to 140° | Yes | Any | 5-min. Automatic Shut-Off | 00000000 | 000000 |
1 3/4" | 1/4 | -10° to 140° | -10° to 140° | Yes | Any | 5-min. Automatic Shut-Off | 00000000 | 000000 |
- For Use With: Air, Hydrogen, Nitrogen
- Accuracy: ±1% Full Scale (Not Graded)
Available Pressure Ranges | |||
---|---|---|---|
Pressure Range | |||
psi | MPa | bar | Resolution, psi |
0 to 30 | 0 to 0.2 | 0 to 2 | 0.01 |
0 to 100 | 0 to 0.7 | 0 to 6.9 | 0.1 |
0 to 300 | 0 to 2 | 0 to 20.7 | 0.1 |
Bottom Connection | ||||||||
---|---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Batteries Included | Mounting Orientation | Features | Each | |
NPT Male | ||||||||
2 1/2" | 1/4 | 0° to 185° | 15° to 140° | Yes | Any | 3-min. Automatic Shut-Off, Maximum Reading Recall | 00000000 | 0000000 |
NPT Male with Calibration Certificate Traceable to NIST | ||||||||
2 1/2" | 1/4 | 0° to 185° | 15° to 140° | Yes | Any | 3-min. Automatic Shut-Off, Maximum Reading Recall | 00000000 | 000000 |
- For Use With: Air, Water, Hydraulic Fluid, Gasoline, Diesel Fuel, Natural Gas
- Accuracy: ±1% Full Scale (Not Graded)
Available Pressure Ranges | |||
---|---|---|---|
Pressure Range | |||
psi | bar | MPa | Resolution, psi |
0 to 5 | 0 to 0.34 | 0 to 0.03 | 0.001 |
0 to 30 | 0 to 2 | 0 to 0.2 | 0.01 |
0 to 100 | 0 to 6.9 | 0 to 0.7 | 0.1 |
0 to 200 | 0 to 13.8 | 0 to 1.3 | 0.1 |
0 to 500 | 0 to 34.4 | 0 to 3.4 | 0.1 |
0 to 1,000 | 0 to 68.9 | 0 to 6.8 | 1 |
0 to 3,000 | 0 to 206 | 0 to 20.6 | 1 |
0 to 5,000 | 0 to 344 | 0 to 34.4 | 1 |
Bottom Connection | ||||||||
---|---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Batteries Included | Mounting Orientation | Features | Each | |
NPT Male | ||||||||
2 1/2" | 1/4 | 0° to 185° | 15° to 140° | Yes | Any | 3-min. Automatic Shut-Off, Maximum Reading Recall | 00000000 | 0000000 |
NPT Male Calibration Certificate Traceable to NIST | ||||||||
2 1/2" | 1/4 | 0° to 185° | 15° to 140° | Yes | Any | 3-min. Automatic Shut-Off, Maximum Reading Recall | 00000000 | 000000 |
Pressure Transmitters with Digital Display
- For Use With: Air, Argon, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±0.5%
- Pipe Connection: NPT Male
- Housing Material: 304 Stainless Steel
- Connection Material: 304 Stainless Steel
- Temperature Range: -40° to 185° F
Read pressure directly at the source and send data remotely with one device. Also known as transducers, these transmitters convert pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. As pressure increases, the output signal from the transmitter will increase. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the pressure range and output signal of the transmitter. Transmitters will only provide accurate readings within the rated pressure range.
To change settings and receive error messages remotely from your PLC or computer, program one of the outputs to use IO Link. You need an IO-Link controller (not included) to connect to your interface.
All have an M12 plug to connect to M12 sockets. When using the analog current output they require two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices. These transmitters can also connect using three wires to send an analog voltage output—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply. View switch wiring diagrams by selecting a part number and clicking Product Detail.
All transmitters are rated IP67 for protection from temporary submersion. UL and C-UL listed as well as CE marked, they meet strict American, Canadian, and European safety standards.
Configurable Analog Transmitter/Digital Switch Output | Configurable Digital Switch Output | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Setpoint Range, psi | Input Voltage | Pipe Size | Ht. | Wd. | No. of | Current | Voltage | Signal Type | No. of | Signal Type | Environmental Rating | Each | |
4-Pole Micro M12 Plug Connection | ||||||||||||||||
0-29 | 29 | 55 | 0-29 | 18-30V DC | 1/4 | 3 3/4" | 1 11/32" | 1 | 4-20mA | 0-10V DC | NPN, PNP | 1 | NPN, PNP | IP67 | 00000000 | 0000000 |
0-73 | 73 | 145 | 0-73 | 18-30V DC | 1/4 | 3 3/4" | 1 11/32" | 1 | 4-20mA | 0-10V DC | NPN, PNP | 1 | NPN, PNP | IP67 | 00000000 | 000000 |
0-145 | 145 | 290 | 0-145 | 18-30V DC | 1/4 | 3 3/4" | 1 11/32" | 1 | 4-20mA | 0-10V DC | NPN, PNP | 1 | NPN, PNP | IP67 | 00000000 | 000000 |
0-290 | 290 | 580 | 0-290 | 18-30V DC | 1/4 | 3 3/4" | 1 11/32" | 1 | 4-20mA | 0-10V DC | NPN, PNP | 1 | NPN, PNP | IP67 | 00000000 | 000000 |
0-725 | 725 | 1,450 | 0-725 | 18-30V DC | 1/4 | 3 3/4" | 1 11/32" | 1 | 4-20mA | 0-10V DC | NPN, PNP | 1 | NPN, PNP | IP67 | 00000000 | 000000 |
0-1,450 | 1,450 | 2,900 | 0-1,450 | 18-30V DC | 1/4 | 3 3/4" | 1 11/32" | 1 | 4-20mA | 0-10V DC | NPN, PNP | 1 | NPN, PNP | IP67 | 00000000 | 000000 |
0-3,625 | 3,625 | 5,800 | 0-3,625 | 18-30V DC | 1/4 | 3 3/4" | 1 11/32" | 1 | 4-20mA | 0-10V DC | NPN, PNP | 1 | NPN, PNP | IP67 | 00000000 | 000000 |
0-5,800 | 5,800 | 9,425 | 0-5,800 | 18-30V DC | 1/4 | 3 3/4" | 1 11/32" | 1 | 4-20mA | 0-10V DC | NPN, PNP | 1 | NPN, PNP | IP67 | 00000000 | 000000 |
0-8,700 | 8,700 | 14,500 | 0-8,700 | 18-30V DC | 1/4 | 3 3/4" | 1 11/32" | 1 | 4-20mA | 0-10V DC | NPN, PNP | 1 | NPN, PNP | IP67 | 00000000 | 000000 |
Pressure Transmitters for Compressed Air
- For Use With: Air, Argon, Nitrogen
- Accuracy: ±0.2%
- Connection: See table
- Housing Material: Polybutylene Plastic
- Connection Material: Nickel-Plated Brass
- Temperature Range: 25° to 120° F
With a pressure range common to most compressed air systems, use these transmitters to monitor your system's air pressure. Also known as transducers, these transmitters convert pressure to an electrical signal that can be interpreted by receiving devices such as remote displays and motor speed controls. They can also connect to a programmable logic controller (PLC) with two digital PNP switch outputs, so you can activate automated controls or alarms when a set pressure is reached. They have a digital display with buttons to change settings.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure range and output signal. As pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
UL and C-UL recognized components, CSA certified, and CE marked, they meet American, Canadian, and European safety standards.
Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Transmitters with voltage output connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
Add a panel-mounting bracket (sold separately) to mount these switches to a control panel for easy viewing and adjusting.
For technical drawings and 3-D models, click on a part number.
Analog Transmitter Output | Digital Switch Output | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Signal | No. of | Signal Type | No. of | Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Setpoint Range, psi | Input Voltage | Ht. | Wd. | Environmental Rating | Each | |
Wire Leads | |||||||||||||
1/8 NPT Male Pipe Connection | |||||||||||||
2.4-20mA | 1 | PNP | 2 | 14.5-145 | 145 | 218 | 14.5-145 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 000000 |
0.6-5V DC | 1 | PNP | 2 | 14.5-145 | 145 | 218 | 14.5-145 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
1/4" OD Push-to-Connect Tube Connection | |||||||||||||
2.4-20mA | 1 | PNP | 2 | 14.5-145 | 145 | 218 | 14.5-145 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
0.6-5V DC | 1 | PNP | 2 | 14.5-145 | 145 | 218 | 14.5-145 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
For Panel Cutout | ||||
---|---|---|---|---|
Ht. | Wd. | Mounting Hole Style | Each | |
1 7/32" | 1 7/32" | Straight | 0000000 | 00000 |
Pressure and Vacuum Transmitters with Digital Display
- For Use With: Air, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±1%
- Pipe Connection Type: Threaded
- Housing Material: Glass-Reinforced Polyester
- Connection Material: 316L Stainless Steel
- Temperature Range: -10° to 175°F
Monitor and control vacuum pumps, air compressors, and hydraulics while viewing readings and warnings on the display. These transmitters, also called transducers, have two outputs, so you can program them to work as a transmitter, a switch, or both. When they reach their setpoint, they send electrical signals to your programmable logic controller (PLC) to trigger actions in your system. Adjust their reset point anywhere within the setpoint range. To change settings and receive error messages remotely from your PLC or computer, program one of the outputs to use IO Link. You need an IO-Link controller (not included) to connect to your interface.
Buttons on the display let you change your setpoint, measuring range, and other settings. To quickly tell the status of your process, you can program the color of the display to red and green. LEDs on the corners also notify you of your output’s switching status. Rotate the head to view the display from the best angle.
You must calibrate your PLC in order for it to interpret signals from these transmitters. As pressure increases, the output signal from the transmitter will increase. These transmitters only give accurate readings within the rated pressure or vacuum range.
All have an M12 plug to connect to M12 Connectors. When using both switching outputs and an IO-Link controller, they require four wires to connect. For their 4-20mA analog output, they need two wires to connect. View switch wiring diagrams by selecting a part number and clicking Product Detail.
To withstand wet environments, these transmitters have a 316L stainless steel connection and are IP rated. Their IP ratings also mean they’re dust tight and stand up to spraying water and brief submersion. UL and C-UL listed as well as CE marked, they meet strict American, Canadian, and European safety standards.
For technical drawings and 3-D models, click on a part number.
Setpoint Range | Configurable Analog Transmitter/Digital Switch Output | Configurable Digital Switch Output | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure Range, psi | Vacuum Range, in. of Hg | Max. Continuous and Short-Term Pressure, psi | Pressure, psi | Vacuum, in. of Hg | Input Voltage | Pipe Size | Ht. | Wd. | No. of | Current | Signal Type | No. of | Signal Type | Scale | Each | |
NPT Female | ||||||||||||||||
0-145 | 29.7-0 | 1,085 | 0-145 | 29.7-0 | 18-30V DC | 1/4 | 3 9/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 0000000 |
0-362.5 | 29.5-0 | 2,175 | 0-362.5 | 29.5-0 | 18-30V DC | 1/4 | 3 9/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
NPT Male | ||||||||||||||||
0-145 | 29.7-0 | 1,085 | 0-145 | 29.7-0 | 18-30V DC | 1/4 | 3 9/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
0-360 | 29.5-0 | 2,175 | 0-360 | 29.5-0 | 18-30V DC | 1/4 | 3 9/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
BSPP Female | ||||||||||||||||
0-87 | 29.5-0 | 600 | 0-87 | 29.5-0 | 18-30V DC | 1/4 | 3 9/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
0-145 | 29.7-0 | 1,085 | 0-145 | 29.7-0 | 18-30V DC | 1/4 | 3 9/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
0-360 | 29.5-0 | 2,175 | 0-360 | 29.5-0 | 18-30V DC | 1/4 | 3 9/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
BSPP Male | ||||||||||||||||
0-7.3 | 14.8-0 | 145 | 0-7.3 | 14.8-0 | 18-30V DC | 1/4 | 3 11/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
0-14.5 | 1.4-0 | 145 | 0-14.5 | 1.4-0 | 18-30V DC | 1/4 | 3 11/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
0-87 | 29.5-0 | 600 | 0-87 | 29.5-0 | 18-30V DC | 1/4 | 3 11/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
0-145 | 29.7-0 | 1,085 | 0-145 | 29.7-0 | 18-30V DC | 1/4 | 3 11/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
0-360 | 29.5-0 | 145 | 0-360 | 29.5-0 | 18-30V DC | 1/4 | 3 11/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
Pressure and Vacuum Transmitters for Compressed Air
- For Use With: Air, Argon, Nitrogen
- Accuracy: ±0.2%
- Connection: See table
- Housing Material: Polybutylene Plastic
- Connection Material: Nickel-Plated Brass
- Temperature Range: 25° to 120° F
Specifically made for compressed air and gas systems, these transmitters remotely monitor pressure and vacuum. Also known as transducers, they convert both pressure and vacuum into an electrical signal that can be interpreted by receiving devices, such as remote displays, and motor speed controls. They also have two digital PNP switch outputs that you can connect to your programmable logic controller (PLC) to activate automated controls or alarms when a set pressure or vacuum is reached. Change settings with the buttons on the digital display.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure or vacuum range and output signal. As pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure or vacuum range.
UL and C-UL recognized components, CSA certified, and CE marked, they meet American, Canadian, and European safety standards.
Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Transmitters with voltage output connect using three wires. Two wires connect to the power supply, and a separate wire sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
Add a panel-mounting bracket (sold separately) to mount these switches to a control panel for easy viewing and adjusting.
For technical drawings and 3-D models, click on a part number.
Analog Transmitter Output | Digital Switch Output | Setpoint Range | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Signal | No. of | Signal Type | No. of | Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Pressure, psi | Vacuum, in. of Hg | Input Voltage | Ht. | Wd. | Environmental Rating | Each | |
Wire Leads | |||||||||||||||
1/8 NPT Male Pipe Connection | |||||||||||||||
4-20mA | 1 | PNP | 2 | 0-14.5 | 29-0 | 14.5 | 72 | 0-14.5 | 29-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 000000 |
1-5V DC | 1 | PNP | 2 | 0-14.5 | 29-0 | 14.5 | 72 | 0-14.5 | 29-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
1/4" OD Push-to-Connect Tube Connection | |||||||||||||||
4-20mA | 1 | PNP | 2 | 0-14.5 | 29-0 | 14.5 | 72 | 0-14.5 | 29-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
1-5V DC | 1 | PNP | 2 | 0-14.5 | 29-0 | 14.5 | 72 | 0-14.5 | 29-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
For Panel Cutout | ||||
---|---|---|---|---|
Ht. | Wd. | Mounting Hole Style | Each | |
1 7/32" | 1 7/32" | Straight | 0000000 | 00000 |
Vacuum Transmitters for Compressed Air
- For Use With: Air, Argon, Nitrogen
- Accuracy: ±0.2%
- Connection: See table
- Housing Material: Polybutylene Plastic
- Connection Material: Nickel-Plated Brass
- Temperature Range: 25° to 120° F
Designed for compressed air and gas systems, these transmitters remotely monitor vacuum. Also known as transducers, they convert vacuum to an electrical signal that can be interpreted by receiving devices, such as remote displays, and motor speed controls. They also have two digital PNP switch outputs that you can connect to your programmable logic controller (PLC) to activate automated controls or alarms when a set vacuum is reached. Change settings and view readings on the digital display.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's vacuum range and output signal. As vacuum decreases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated vacuum range.
UL and C-UL recognized components, CSA certified, and CE marked, they meet American, Canadian, and European safety standards.
Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Transmitters with voltage output connect using three wires. Two wires connect to the power supply, and a separate wire sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
Add a panel-mounting bracket (sold separately) to mount these switches to a control panel for easy viewing and adjusting.
For technical drawings and 3-D models, click on a part number.
Analog Transmitter Output | Digital Switch Output | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Signal | No. of | Signal Type | No. of | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Setpoint Range, in. of Hg | Input Voltage | Ht. | Wd. | Environmental Rating | Each | |
Wire Leads | |||||||||||||
1/8 NPT Male Pipe Connection | |||||||||||||
4-20mA | 1 | PNP | 2 | 30-0 | 15 | 72 | 30-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 000000 |
1-5V DC | 1 | PNP | 2 | 30-0 | 15 | 72 | 30-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
1/4" OD Push-to-Connect Tube Connection | |||||||||||||
4-20mA | 1 | PNP | 2 | 30-0 | 15 | 72 | 30-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
1-5V DC | 1 | PNP | 2 | 30-0 | 15 | 72 | 30-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
For Panel Cutout | ||||
---|---|---|---|---|
Ht. | Wd. | Mounting Hole Style | Each | |
1 7/32" | 1 7/32" | Straight | 0000000 | 00000 |
Ultra-High-Accuracy Digital Test Gauges for Pressure
With an accuracy of ±0.05%, these have the highest accuracy of all our test gauges. Use them for testing, calibrating, laboratory applications, and other critical processes that require precision. They have a five-digit LCD display that allows for easy reading of measurements.
For technical drawings and 3-D models, click on a part number.
- For Use With: Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water
- Accuracy: ±0.05% Full Scale (Grade 5A)
Available Pressure Ranges | ||||||
---|---|---|---|---|---|---|
Pressure Range | ||||||
psi | kPa | bar | kg/cm2 | MPa | in. of H2O | Resolution, psi |
0 to 10 | 0 to 65 | 0 to 0.6 | 0 to 0.7 | 0 to 0.06 | 0 to 270 | 0.001 |
0 to 15 | 0 to 100 | 0 to 1 | 0 to 1 | 0 to 0.1 | 0 to 410 | 0.001 |
0 to 30 | 0 to 200 | 0 to 2 | 0 to 2 | 0 to 0.2 | 0 to 830 | 0.001 |
0 to 60 | 0 to 410 | 0 to 4 | 0 to 4 | 0 to 0.4 | 0 to 1,600 | 0.001 |
0 to 100 | 0 to 680 | 0 to 6 | 0 to 7 | 0 to 0.6 | 0 to 2,700 | 0.01 |
0 to 160 | 0 to 1,100 | 0 to 11 | 0 to 11 | 0 to 1.1 | 0 to 4,400 | 0.01 |
0 to 200 | 0 to 1,300 | 0 to 13 | 0 to 14 | 0 to 1.3 | 0 to 5,500 | 0.01 |
0 to 300 | 0 to 2,000 | 0 to 20 | 0 to 20 | 0 to 2 | 0 to 8,300 | 0.01 |
0 to 600 | 0 to 4,100 | 0 to 40 | 0 to 40 | 0 to 4 | 0 to 16,600 | 0.01 |
0 to 800 | 0 to 5,500 | 0 to 55 | 0 to 55 | 0 to 5 | 0 to 22,100 | 0.01 |
0 to 1,000 | 0 to 6,800 | 0 to 65 | 0 to 70 | 0 to 6 | 0 to 27,700 | 0.1 |
0 to 2,000 | 0 to 13,700 | 0 to 135 | 0 to 140 | 0 to 13 | 0 to 55,400 | 0.1 |
0 to 3,000 | 0 to 20,600 | 0 to 205 | 0 to 210 | 0 to 20 | 0 to 83,100 | 0.1 |
0 to 5,000 | 0 to 34,400 | 0 to 340 | 0 to 350 | 0 to 30 | __ | 0.1 |
Bottom Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|
Dial Dia. | Pipe Size | Environment Temperature Range, °F | Process Temperature Range, °F | Environmental Rating | Features | Digit Ht. | Batteries Included | Each | |
NPT Male—Calibration Certificate Traceable to NIST | |||||||||
3" | 1/4 | -40° to 180° | 0° to 150° | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 IP65 | Configurable Automatic Shut-Off (2 min., 5 min., 15 min., 30 min., or Never) | 1 1/8" | Yes | 0000000 | 000000000 |
High-Accuracy Digital Test Gauges for Pressure
Not only do these gauges have an accuracy of ±0.25%, they also have a four-digit LCD display that allows for easy reading of measurements. Use them for testing, calibrating, laboratory applications, and other critical applications that require precision.
For technical drawings and 3-D models, click on a part number.
- For Use With: Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water
- Accuracy: ±0.25% Full Scale (Not Graded)
Available Pressure Ranges | |||
---|---|---|---|
Pressure Range | |||
psi | bar | MPa | Resolution, psi |
0 to 3 | 0 to 1 | 0 to 1.4 | 0.01 |
0 to 5 | 0 to 1 | 0 to 1.4 | 0.01 |
0 to 15 | 0 to 1 | 0 to 1.4 | 0.01 |
0 to 30 | 0 to 2 | 0 to 1.4 | 0.1 |
0 to 100 | 0 to 7 | 0 to 1.4 | 0.1 |
0 to 199.9 | 0 to 14 | 0 to 1.4 | 0.1 |
0 to 300 | 0 to 20 | 0 to 2 | 1 |
0 to 500 | 0 to 35 | 0 to 3.5 | 1 |
0 to 1,000 | 0 to 70 | 0 to 7 | 1 |
0 to 3,000 | 0 to 200 | 0 to 20 | 1 |
0 to 5,000 | 0 to 350 | 0 to 35 | 1 |
Dial | Bottom Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Pipe Size | Environment Temperature Range, °F | Process Temperature Range, °F | Environment | Features | Digit Ht. | Batteries Included | Each | |
NPT Male | ||||||||||
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | __ | 5-min. Automatic Shut-Off | 1/2" | Yes | 0000000 | 0000000 |
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | Hazardous Location | 5-min. Automatic Shut-Off | 1/2" | Yes | 0000000 | 000000 |
NPT Male—Calibration Certificate Traceable to NIST | ||||||||||
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | __ | 5-min. Automatic Shut-Off | 1/2" | Yes | 0000000 | 000000 |
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | Hazardous Location | 5-min. Automatic Shut-Off | 1/2" | Yes | 0000000 | 000000 |
- For Use With: Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water
- Accuracy: ±0.25% Full Scale (Not Graded)
Available Pressure Ranges | |||
---|---|---|---|
Pressure Range | |||
psi | bar | MPa | Resolution, psi |
0 to 3 | 0 to 1 | 0 to 1.4 | 0.01 |
0 to 5 | 0 to 1 | 0 to 1.4 | 0.01 |
0 to 15 | 0 to 1 | 0 to 1.4 | 0.01 |
0 to 30 | 0 to 2 | 0 to 1.4 | 0.1 |
0 to 100 | 0 to 7 | 0 to 1.4 | 0.1 |
0 to 199.9 | 0 to 14 | 0 to 1.4 | 0.1 |
0 to 300 | 0 to 20 | 0 to 2 | 1 |
0 to 500 | 0 to 35 | 0 to 3.5 | 1 |
0 to 1,000 | 0 to 70 | 0 to 7 | 1 |
0 to 3,000 | 0 to 200 | 0 to 20 | 1 |
0 to 5,000 | 0 to 350 | 0 to 35 | 1 |
Dial | Bottom Connection | ||||||||
---|---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Pipe Size | Environment Temperature Range, °F | Process Temperature Range, °F | Digit Ht. | Wire Connection Type | Input Voltage | Each | |
NPT Male | |||||||||
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | 1/2" | Wire Leads | 8-24V AC, 9-32V DC | 0000000 | 0000000 |
NPT Male—Calibration Certificate Traceable to NIST | |||||||||
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | 1/2" | Wire Leads | 8-24V AC, 9-32V DC | 0000000 | 000000 |