About Pipe Size
More
About Pressure Gauges
More
About Pressure Transmitters
More
Digital High-Accuracy Pressure Gauges
Plastic Case With
Bottom Connection
A four-digit LCD display allows for easy reading of measurements. The LCD shuts off automatically to extend battery life. Gauges are commonly used with pneumatic regulators, compressors, and in critical processes that require high accuracy, such as hydraulic and laboratory applications.
For technical drawings and 3-D models, click on a part number.
- For Use With: Air
- Accuracy: ±0.5% Full Scale (Not Graded)
Available Pressure Ranges | ||||
---|---|---|---|---|
psi | atm | bar | kg/cm2 | Resolution, psi |
0 to 100 | 0 to 6.8 | 0 to 6.8 | 0 to 7 | 0.1 |
0 to 1,000 | 0 to 68 | 0 to 68.9 | 0 to 70.3 | 1 |
Gauge with Bottom Connection | 9V Alkaline Disposable Battery | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Dp. | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Batteries Included | Battery Size | Number of Batteries Required | Mounting Orientation | Features | Each | Pkg. Qty. | Pkg. | ||
NPT Female | |||||||||||||||
4 1/16" | 2 11/16" | 1 7/8" | 1/8 | -40° to 150° | 35° to 130° | No | 9V | 1 | Any | 1-hr. Automatic Shut-Off | 00000000 | 0000000 | 1 | 00000000 | 00000 |
- For Use With: Air, Carbon Dioxide, Hydrogen, Nitrogen, Natural Gas
- Accuracy: ±1% Full Scale (Grade 1A)
Available Pressure Ranges | ||||
---|---|---|---|---|
Pressure Range | ||||
psi | bar | kg/cm2 | MPa | Resolution, psi |
0 to 145 | 0 to 10 | 0 to 10 | 0 to 1 | 0.1 |
Center Back Connection | ||||||||
---|---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Batteries Included | Mounting Orientation | Features | Each | |
NPT Male | ||||||||
1 3/4" | 1/8 | -10° to 140° | -10° to 140° | Yes | Any | 5-min. Automatic Shut-Off | 000000 | 000000 |
1 3/4" | 1/4 | -10° to 140° | -10° to 140° | Yes | Any | 5-min. Automatic Shut-Off | 000000 | 00000 |
NPT Male with Calibration Certificate Traceable to NIST | ||||||||
1 3/4" | 1/8 | -10° to 140° | -10° to 140° | Yes | Any | 5-min. Automatic Shut-Off | 00000000 | 000000 |
1 3/4" | 1/4 | -10° to 140° | -10° to 140° | Yes | Any | 5-min. Automatic Shut-Off | 00000000 | 000000 |
Low-Pressure Gauges for Chemicals
A plastic or stainless steel guard, also known as an isolator, protects the gauge from damage caused by corrosive chemicals. Use them with pumps, filters, regulators, and in process lines to measure and display pressures.
Polypropylene and 316 stainless steel guards are more chemical resistant than PVC and CPVC guards.
For technical drawings and 3-D models, click on a part number.
- For Use With: Water, Salt Water, Hydraulic Fluid, Bleach, Boric Acid, and Carbon Dioxide
- Accuracy: ±2% Mid Scale (Grade B)
Available Pressure Ranges | |||||
---|---|---|---|---|---|
Pressure Range | Graduation Marks | Numeric Increments | |||
psi | kg/cm2 | psi | kg/cm2 | psi | kg/cm2 |
0 to 30 | 0 to 2.1 | 0.5 | 0.05 | 5 | 0.5 |
0 to 60 | 0 to 4.2 | 1 | 0.1 | 10 | 1 |
0 to 150 | 0 to 11.2 | 2 | 0.2 | 20 | 2 |
- For Use With: Water, Salt Water, Hydraulic Fluid, Bleach, Boric Acid, and Carbon Dioxide
- Accuracy: ±2% Mid Scale (Grade B)
Available Pressure Ranges | |||||
---|---|---|---|---|---|
Pressure Range | Graduation Marks | Numeric Increments | |||
psi | kg/cm2 | psi | kg/cm2 | psi | kg/cm2 |
0 to 30 | 0 to 2.1 | 0.5 | 0.05 | 5 | 0.5 |
0 to 60 | 0 to 4.2 | 1 | 0.1 | 10 | 1 |
0 to 150 | 0 to 11.2 | 2 | 0.2 | 20 | 2 |
- For Use With: Water, Salt Water, Hydraulic Fluid, Boric Acid, and Carbon Dioxide
- Accuracy: ±2% Mid Scale (Grade B)
Available Pressure Ranges | |||||
---|---|---|---|---|---|
Pressure Range | Graduation Marks | Numeric Increments | |||
psi | kg/cm2 | psi | kg/cm2 | psi | kg/cm2 |
0 to 30 | 0 to 2.1 | 0.5 | 0.05 | 5 | 0.5 |
0 to 60 | 0 to 4.2 | 1 | 0.1 | 10 | 1 |
0 to 150 | 0 to 11.2 | 2 | 0.2 | 20 | 2 |
Bottom Connection | ||||||||
---|---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Case Color | Guard Material | Guard Color | Each | |
NPT Female | ||||||||
2" | 1/4 | 40° to 240° | 40° to 240° | Black | Polypropylene Plastic | White | 0000000 | 0000000 |
3-in-1 Pressure and Vacuum Gauges
These portable gauges have three different dials to display pressure and vacuum measurements on a low, medium, and high scale. Also known as compound gauges, they measure both pressure and vacuum in hydraulic applications.
For technical drawings and 3-D models, click on a part number.
- For Use With: Air and Hydraulic Fluid
- Accuracy: ±2% Mid Scale (Grade B)
Left Gauge | Middle Gauge | Right Gauge | Bottom Connection | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Pressure Range, psi | Pressure Range, kg/cm2 | Vacuum Range, in. of Hg | Vacuum Range, cm of Hg | Pressure Range, psi | Pressure Range, kg/cm2 | Pressure Range, psi | Pressure Range, kg/cm2 | Environment Temp. Range | Process Temp. Range | Overall Dia. | Each | |
NPTF Male | ||||||||||||||
2" | 1/8 | 0 to 150 | 0 to 10 | 30 to 0 | 76 to 0 | 0 to 5,000 | 0 to 350 | 0 to 600 | 0 to 42 | -40° to 120° | -40° to 190° | 6 7/16" | 0000000 | 0000000 |
Pressure Transmitters for Compressed Air
- For Use With: Air, Argon, Nitrogen
- Accuracy: ±0.2%
- Connection: See table
- Housing Material: Polybutylene Plastic
- Connection Material: Nickel-Plated Brass
- Temperature Range: 25° to 120° F
With a pressure range common to most compressed air systems, use these transmitters to monitor your system's air pressure. Also known as transducers, these transmitters convert pressure to an electrical signal that can be interpreted by receiving devices such as remote displays and motor speed controls. They can also connect to a programmable logic controller (PLC) with two digital PNP switch outputs, so you can activate automated controls or alarms when a set pressure is reached. They have a digital display with buttons to change settings.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure range and output signal. As pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
UL and C-UL recognized components, CSA certified, and CE marked, they meet American, Canadian, and European safety standards.
Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Transmitters with voltage output connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
Add a panel-mounting bracket (sold separately) to mount these switches to a control panel for easy viewing and adjusting.
For technical drawings and 3-D models, click on a part number.
Analog Transmitter Output | Digital Switch Output | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Signal | No. of | Signal Type | No. of | Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Setpoint Range, psi | Input Voltage | Ht. | Wd. | Environmental Rating | Each | |
Wire Leads | |||||||||||||
1/8 NPT Male Pipe Connection | |||||||||||||
2.4-20mA | 1 | PNP | 2 | 14.5-145 | 145 | 218 | 14.5-145 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 000000 |
0.6-5V DC | 1 | PNP | 2 | 14.5-145 | 145 | 218 | 14.5-145 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
1/4" OD Push-to-Connect Tube Connection | |||||||||||||
2.4-20mA | 1 | PNP | 2 | 14.5-145 | 145 | 218 | 14.5-145 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
0.6-5V DC | 1 | PNP | 2 | 14.5-145 | 145 | 218 | 14.5-145 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
For Panel Cutout | ||||
---|---|---|---|---|
Ht. | Wd. | Mounting Hole Style | Each | |
1 7/32" | 1 7/32" | Straight | 0000000 | 00000 |
Pressure and Vacuum Transmitters for Compressed Air
- For Use With: Air, Argon, Nitrogen
- Accuracy: ±0.2%
- Connection: See table
- Housing Material: Polybutylene Plastic
- Connection Material: Nickel-Plated Brass
- Temperature Range: 25° to 120° F
Specifically made for compressed air and gas systems, these transmitters remotely monitor pressure and vacuum. Also known as transducers, they convert both pressure and vacuum into an electrical signal that can be interpreted by receiving devices, such as remote displays, and motor speed controls. They also have two digital PNP switch outputs that you can connect to your programmable logic controller (PLC) to activate automated controls or alarms when a set pressure or vacuum is reached. Change settings with the buttons on the digital display.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure or vacuum range and output signal. As pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure or vacuum range.
UL and C-UL recognized components, CSA certified, and CE marked, they meet American, Canadian, and European safety standards.
Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Transmitters with voltage output connect using three wires. Two wires connect to the power supply, and a separate wire sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
Add a panel-mounting bracket (sold separately) to mount these switches to a control panel for easy viewing and adjusting.
For technical drawings and 3-D models, click on a part number.
Analog Transmitter Output | Digital Switch Output | Setpoint Range | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Signal | No. of | Signal Type | No. of | Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Pressure, psi | Vacuum, in. of Hg | Input Voltage | Ht. | Wd. | Environmental Rating | Each | |
Wire Leads | |||||||||||||||
1/8 NPT Male Pipe Connection | |||||||||||||||
4-20mA | 1 | PNP | 2 | 0-14.5 | 29-0 | 14.5 | 72 | 0-14.5 | 29-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 000000 |
1-5V DC | 1 | PNP | 2 | 0-14.5 | 29-0 | 14.5 | 72 | 0-14.5 | 29-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
1/4" OD Push-to-Connect Tube Connection | |||||||||||||||
4-20mA | 1 | PNP | 2 | 0-14.5 | 29-0 | 14.5 | 72 | 0-14.5 | 29-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
1-5V DC | 1 | PNP | 2 | 0-14.5 | 29-0 | 14.5 | 72 | 0-14.5 | 29-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
For Panel Cutout | ||||
---|---|---|---|---|
Ht. | Wd. | Mounting Hole Style | Each | |
1 7/32" | 1 7/32" | Straight | 0000000 | 00000 |
Vacuum Transmitters for Compressed Air
- For Use With: Air, Argon, Nitrogen
- Accuracy: ±0.2%
- Connection: See table
- Housing Material: Polybutylene Plastic
- Connection Material: Nickel-Plated Brass
- Temperature Range: 25° to 120° F
Designed for compressed air and gas systems, these transmitters remotely monitor vacuum. Also known as transducers, they convert vacuum to an electrical signal that can be interpreted by receiving devices, such as remote displays, and motor speed controls. They also have two digital PNP switch outputs that you can connect to your programmable logic controller (PLC) to activate automated controls or alarms when a set vacuum is reached. Change settings and view readings on the digital display.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's vacuum range and output signal. As vacuum decreases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated vacuum range.
UL and C-UL recognized components, CSA certified, and CE marked, they meet American, Canadian, and European safety standards.
Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Transmitters with voltage output connect using three wires. Two wires connect to the power supply, and a separate wire sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
Add a panel-mounting bracket (sold separately) to mount these switches to a control panel for easy viewing and adjusting.
For technical drawings and 3-D models, click on a part number.
Analog Transmitter Output | Digital Switch Output | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Signal | No. of | Signal Type | No. of | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Setpoint Range, in. of Hg | Input Voltage | Ht. | Wd. | Environmental Rating | Each | |
Wire Leads | |||||||||||||
1/8 NPT Male Pipe Connection | |||||||||||||
4-20mA | 1 | PNP | 2 | 30-0 | 15 | 72 | 30-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 000000 |
1-5V DC | 1 | PNP | 2 | 30-0 | 15 | 72 | 30-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
1/4" OD Push-to-Connect Tube Connection | |||||||||||||
4-20mA | 1 | PNP | 2 | 30-0 | 15 | 72 | 30-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
1-5V DC | 1 | PNP | 2 | 30-0 | 15 | 72 | 30-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
For Panel Cutout | ||||
---|---|---|---|---|
Ht. | Wd. | Mounting Hole Style | Each | |
1 7/32" | 1 7/32" | Straight | 0000000 | 00000 |
Ultra-High-Accuracy Digital Test Gauges for Pressure
With an accuracy of ±0.05%, these have the highest accuracy of all our test gauges. Use them for testing, calibrating, laboratory applications, and other critical processes that require precision. They have a five-digit LCD display that allows for easy reading of measurements.
For technical drawings and 3-D models, click on a part number.
- For Use With: Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water
- Accuracy: ±0.05% Full Scale (Grade 5A)
Available Pressure Ranges | ||||||
---|---|---|---|---|---|---|
Pressure Range | ||||||
psi | kPa | bar | kg/cm2 | MPa | in. of H2O | Resolution, psi |
0 to 10 | 0 to 65 | 0 to 0.6 | 0 to 0.7 | 0 to 0.06 | 0 to 270 | 0.001 |
0 to 15 | 0 to 100 | 0 to 1 | 0 to 1 | 0 to 0.1 | 0 to 410 | 0.001 |
0 to 30 | 0 to 200 | 0 to 2 | 0 to 2 | 0 to 0.2 | 0 to 830 | 0.001 |
0 to 60 | 0 to 410 | 0 to 4 | 0 to 4 | 0 to 0.4 | 0 to 1,600 | 0.001 |
0 to 100 | 0 to 680 | 0 to 6 | 0 to 7 | 0 to 0.6 | 0 to 2,700 | 0.01 |
0 to 160 | 0 to 1,100 | 0 to 11 | 0 to 11 | 0 to 1.1 | 0 to 4,400 | 0.01 |
0 to 200 | 0 to 1,300 | 0 to 13 | 0 to 14 | 0 to 1.3 | 0 to 5,500 | 0.01 |
0 to 300 | 0 to 2,000 | 0 to 20 | 0 to 20 | 0 to 2 | 0 to 8,300 | 0.01 |
0 to 600 | 0 to 4,100 | 0 to 40 | 0 to 40 | 0 to 4 | 0 to 16,600 | 0.01 |
0 to 800 | 0 to 5,500 | 0 to 55 | 0 to 55 | 0 to 5 | 0 to 22,100 | 0.01 |
0 to 1,000 | 0 to 6,800 | 0 to 65 | 0 to 70 | 0 to 6 | 0 to 27,700 | 0.1 |
0 to 2,000 | 0 to 13,700 | 0 to 135 | 0 to 140 | 0 to 13 | 0 to 55,400 | 0.1 |
0 to 3,000 | 0 to 20,600 | 0 to 205 | 0 to 210 | 0 to 20 | 0 to 83,100 | 0.1 |
0 to 5,000 | 0 to 34,400 | 0 to 340 | 0 to 350 | 0 to 30 | __ | 0.1 |
Bottom Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|
Dial Dia. | Pipe Size | Environment Temperature Range, °F | Process Temperature Range, °F | Environmental Rating | Features | Digit Ht. | Batteries Included | Each | |
NPT Male—Calibration Certificate Traceable to NIST | |||||||||
3" | 1/4 | -40° to 180° | 0° to 150° | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 IP65 | Configurable Automatic Shut-Off (2 min., 5 min., 15 min., 30 min., or Never) | 1 1/8" | Yes | 0000000 | 000000000 |
Tire Inflator Gauges
Mate these gauges to a compressed air line to measure pressure while inflating tires. They are strong enough to stand up to constant use.
Indicator bar readouts slide out of the top of the gauge to display pressure readings.
Gauges that meet OSHA 29 CFR 1910.177 are designed to safely fill sidewall truck tires. They have a hose long enough to inflate the tires from a safe distance.
Gauges with a rubber sleeve prevent metal-to-metal contact with your tire to avoid damaging it.Gauges with a clip-on Schrader connection don't require you to hold them while you’re filling up your tire.
Pressure Range | Hose | Air Inlet | Air Outlet | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Head Type | Number of Heads | psi | kg/cm2 | Numeric Increments, psi | Indicator Bar Material | Lg. | Material | Pipe Size | Thread Type | Thread Size | Thread Type | Schrader Valve Connection Type | Features | Each | |
Zinc-Plated Zinc | |||||||||||||||
Angled | 2 | 10-120 | 1-5 | 2 | Brass | 12" | Rubber | 1/4 | NPT | 0.305"-32 | Schrader | Press-and-Hold | Rubber Sleeve | 00000000 | 000000 |
Straight | 1 | 10-90 | 1-5 | 2 | Brass | 12" | Rubber | 1/4 | NPT | 0.305"-32 | Schrader | Press-and-Hold | Rubber Sleeve | 00000000 | 00000 |
Pressure Range | Hose | Air Inlet | Air Outlet | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Head Type | Number of Heads | psi | kPa | Numeric Increments, psi | Lg. | Material | Pipe Size | Thread Type | Thread Size | Thread Type | Schrader Valve Connection Type | Specifications Met | Each | |
Chrome-Plated Zinc | ||||||||||||||
Straight | 1 | 0-150 | 0-1,030 | 0.1 | 5ft. | Rubber | 1/4 | NPT | 0.305"-32 | Schrader | Clip On | OSHA Compliant 29 CFR 1910.177 | 00000000 | 0000000 |
Straight | 1 | 0-150 | 0-1,030 | 0.1 | 10ft. | Rubber | 1/4 | NPT | 0.305"-32 | Schrader | Clip On | OSHA Compliant 29 CFR 1910.177 | 00000000 | 000000 |
Straight | 1 | 0-150 | 0-1,030 | 0.1 | 15ft. | Rubber | 1/4 | NPT | 0.305"-32 | Schrader | Clip On | OSHA Compliant 29 CFR 1910.177 | 00000000 | 000000 |
Compression Testers
Check engine compression to maintain top performance. Testers have a quick-release coupler between the hose and the gauge.
Hose | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Readout Type | For Engine Type | Adapter Sizes Included, mm | Scale | Pressure Range, psi | Accuracy | Dial Dia. | Lg. | Material | External Reinforcement | Includes | Each | |
Dial | Gasoline | 14 | psi, kg/cm2, bar, kPa | 0-300 | ±2% | 3" | 15" | Rubber | Braided | Replacement Valve Core | 0000000 | 000000 |