About Pressure Transmitters
More
Pressure and Vacuum Transmitters



- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy:
0-15 psi Pressure Range: ±1.5%
All Other Pressure Ranges: ±1% - Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material:
0-15 psi Pressure Range: 316L Stainless Steel
All Other Pressure Ranges: 304 Stainless Steel - Temperature Range: -40° to 255° F
Monitor and control vacuum pumps, air compressors, and hydraulics. These transmitters convert both pressure and vacuum into an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. As pressure increases, the output signal from the transmitter will increase. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure or vacuum range and output signal. Transmitters will only provide accurate readings within the rated pressure or vacuum range.
Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Transmitters with voltage output connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
All transmitters are rated NEMA 4X for use in washdown and corrosive environments. IP67 rated transmitters are protected from temporary submersion during washdowns. IP65 rated transmitters are protected from dust and low-pressure jets of water.
Transmitters with a micro M12 plug are compatible with micro M12 connectors.
For technical drawings and 3-D models, click on a part number.
Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-15 | 30-0 | 30 | 30 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 0000000 |
0-30 | 30-0 | 60 | 60 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 0000000 | 000000 |
0-45 | 30-0 | 90 | 90 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 0000000 | 000000 |
0-60 | 30-0 | 120 | 120 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 0000000 | 000000 |
0-85 | 30-0 | 170 | 170 | 9-36V DC | 1/4 | 2" | 15/16" | IP67, NEMA 4X | 00000000 | 000000 |
0-100 | 30-0 | 200 | 200 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 0000000 | 000000 |
0-150 | 30-0 | 300 | 300 | 9-36V DC | 1/4 | 2" | 15/16" | IP67, NEMA 4X | 00000000 | 000000 |
0-200 | 30-0 | 400 | 400 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 0000000 | 000000 |
0-300 | 30-0 | 600 | 600 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 0000000 | 000000 |
0-500 | 30-0 | 1,000 | 1,000 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 000000 |
Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-15 | 30-0 | 30 | 30 | 9-36V DC | 1/4 | 1 11/16" | 7/8" | IP67, NEMA 4X | 00000000 | 0000000 |
0-30 | 30-0 | 60 | 60 | 9-36V DC | 1/4 | 1 11/16" | 7/8" | IP67, NEMA 4X | 00000000 | 000000 |
0-45 | 30-0 | 90 | 90 | 9-36V DC | 1/4 | 1 11/16" | 7/8" | IP67, NEMA 4X | 00000000 | 000000 |
0-60 | 30-0 | 120 | 120 | 9-36V DC | 1/4 | 1 11/16" | 7/8" | IP67, NEMA 4X | 000000 | 000000 |
0-85 | 30-0 | 170 | 170 | 9-36V DC | 1/4 | 1 11/16" | 7/8" | IP67, NEMA 4X | 00000000 | 000000 |
0-100 | 30-0 | 200 | 200 | 9-36V DC | 1/4 | 1 11/16" | 7/8" | IP67, NEMA 4X | 00000000 | 000000 |
0-150 | 30-0 | 300 | 300 | 9-36V DC | 1/4 | 1 11/16" | 7/8" | IP67, NEMA 4X | 00000000 | 000000 |
0-200 | 30-0 | 400 | 400 | 9-36V DC | 1/4 | 1 11/16" | 7/8" | IP67, NEMA 4X | 00000000 | 000000 |
0-300 | 30-0 | 600 | 600 | 9-36V DC | 1/4 | 1 11/16" | 7/8" | IP67, NEMA 4X | 00000000 | 000000 |
0-500 | 30-0 | 1,000 | 1,000 | 9-36V DC | 1/4 | 1 11/16" | 7/8" | IP67, NEMA 4X | 00000000 | 000000 |
Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Electrical Connection Thread Size | Ht. | Wd. | Environmental Rating | Each | |
0-15 | 30-0 | 30 | 30 | 9-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 00000000 | 0000000 |
0-30 | 30-0 | 60 | 60 | 9-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 0000000 | 000000 |
0-45 | 30-0 | 90 | 90 | 9-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 00000000 | 000000 |
0-60 | 30-0 | 120 | 120 | 9-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 00000000 | 000000 |
0-85 | 30-0 | 170 | 170 | 9-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 00000000 | 000000 |
0-100 | 30-0 | 200 | 200 | 9-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 00000000 | 000000 |
0-150 | 30-0 | 300 | 300 | 9-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 00000000 | 000000 |
0-200 | 30-0 | 400 | 400 | 9-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 00000000 | 000000 |
0-300 | 30-0 | 600 | 600 | 9-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 00000000 | 000000 |
0-500 | 30-0 | 1,000 | 1,000 | 9-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 00000000 | 000000 |
Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-15 | 30-0 | 30 | 30 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 0000000 |
0-30 | 30-0 | 60 | 60 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 000000 |
0-45 | 30-0 | 90 | 90 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 000000 |
0-60 | 30-0 | 120 | 120 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 000000 |
0-85 | 30-0 | 170 | 170 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 000000 |
0-100 | 30-0 | 200 | 200 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 000000 |
0-150 | 30-0 | 300 | 300 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 0000000 | 000000 |
0-200 | 30-0 | 400 | 400 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 000000 |
0-300 | 30-0 | 600 | 600 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 000000 |
0-500 | 30-0 | 1,000 | 1,000 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 000000 |
Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-15 | 30-0 | 30 | 30 | 14-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 0000000 |
0-30 | 30-0 | 60 | 60 | 14-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 000000 |
0-45 | 30-0 | 90 | 90 | 14-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 000000 |
0-60 | 30-0 | 120 | 120 | 14-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 000000 |
0-85 | 30-0 | 170 | 170 | 14-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 000000 |
0-100 | 30-0 | 200 | 200 | 14-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 000000 |
0-150 | 30-0 | 300 | 300 | 14-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 0000000 | 000000 |
0-200 | 30-0 | 400 | 400 | 14-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 000000 |
0-300 | 30-0 | 600 | 600 | 14-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 000000 |
0-500 | 30-0 | 1,000 | 1,000 | 14-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 000000 |
Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Electrical Connection Thread Size | Ht. | Wd. | Environmental Rating | Each | |
0-15 | 30-0 | 30 | 30 | 14-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 00000000 | 0000000 |
0-30 | 30-0 | 60 | 60 | 14-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 00000000 | 000000 |
0-45 | 30-0 | 90 | 90 | 14-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 00000000 | 000000 |
0-60 | 30-0 | 120 | 120 | 14-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 00000000 | 000000 |
0-85 | 30-0 | 170 | 170 | 14-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 00000000 | 000000 |
0-100 | 30-0 | 200 | 200 | 14-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 00000000 | 000000 |
0-150 | 30-0 | 300 | 300 | 14-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 00000000 | 000000 |
0-200 | 30-0 | 400 | 400 | 14-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 00000000 | 000000 |
0-300 | 30-0 | 600 | 600 | 14-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 00000000 | 000000 |
0-500 | 30-0 | 1,000 | 1,000 | 14-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 0000000 | 000000 |
Pressure and Vacuum Transmitters with Digital Display

- For Use With: Air, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±1%
- Pipe Connection Type: Threaded
- Housing Material: Glass-Reinforced Polyester
- Connection Material: 316L Stainless Steel
- Temperature Range: -10° to 175°F
Monitor and control vacuum pumps, air compressors, and hydraulics while viewing readings and warnings on the display. These transmitters, also called transducers, have two outputs, so you can program them to work as a transmitter, a switch, or both. When they reach their setpoint, they send electrical signals to your programmable logic controller (PLC) to trigger actions in your system. Adjust their reset point anywhere within the setpoint range. To change settings and receive error messages remotely from your PLC or computer, program one of the outputs to use IO Link. You need an IO-Link controller (not included) to connect to your interface.
Buttons on the display let you change your setpoint, measuring range, and other settings. To quickly tell the status of your process, you can program the color of the display to red and green. LEDs on the corners also notify you of your output’s switching status. Rotate the head to view the display from the best angle.
You must calibrate your PLC in order for it to interpret signals from these transmitters. As pressure increases, the output signal from the transmitter will increase. These transmitters only give accurate readings within the rated pressure or vacuum range.
All have an M12 plug to connect to M12 Connectors. When using both switching outputs and an IO-Link controller, they require four wires to connect. For their 4-20mA analog output, they need two wires to connect. View switch wiring diagrams by selecting a part number and clicking Product Detail.
To withstand wet environments, these transmitters have a 316L stainless steel connection and are IP rated. Their IP ratings also mean they’re dust tight and stand up to spraying water and brief submersion. UL and C-UL listed as well as CE marked, they meet strict American, Canadian, and European safety standards.
For technical drawings and 3-D models, click on a part number.
Setpoint Range | Configurable Analog Transmitter/Digital Switch Output | Configurable Digital Switch Output | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure Range, psi | Vacuum Range, in. of Hg | Max. Continuous and Short-Term Pressure, psi | Pressure, psi | Vacuum, in. of Hg | Input Voltage | Pipe Size | Ht. | Wd. | No. of | Current | Signal Type | No. of | Signal Type | Scale | Each | |
NPT Female | ||||||||||||||||
0-14.5 | 29.5-0 | 145 | 0-14.5 | 29.5-0 | 18-30V DC | 1/4 | 3 9/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | in. of H2O, in. of Hg, kPa, mbar, psi | 0000000 | 0000000 |
0-145 | 29.7-0 | 1,085 | 0-145 | 29.7-0 | 18-30V DC | 1/4 | 3 9/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
0-362.5 | 29.5-0 | 2,175 | 0-362.5 | 29.5-0 | 18-30V DC | 1/4 | 3 9/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
NPT Male | ||||||||||||||||
0-14.5 | 29.5-0 | 145 | 0-14.5 | 29.5-0 | 18-30V DC | 1/4 | 3 9/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | in. of H2O, in. of Hg, kPa, mbar, psi | 0000000 | 000000 |
0-145 | 29.7-0 | 1,085 | 0-145 | 29.7-0 | 18-30V DC | 1/4 | 3 9/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
0-360 | 29.5-0 | 2,175 | 0-360 | 29.5-0 | 18-30V DC | 1/4 | 3 9/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
BSPP Female | ||||||||||||||||
0-7.3 | 14.8-0 | 145 | 0-7.3 | 14.8-0 | 18-30V DC | 1/4 | 3 9/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | in. of H2O, kPa, mbar, psi | 0000000 | 000000 |
0-14.5 | 1.4-0 | 145 | 0-14.5 | 1.4-0 | 18-30V DC | 1/4 | 3 9/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | in. of H2O, kPa, mbar, psi | 0000000 | 000000 |
0-14.5 | 29.5-0 | 145 | 0-14.5 | 29.5-0 | 18-30V DC | 1/4 | 3 9/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | in. of H2O, in. of Hg, kPa, mbar, psi | 0000000 | 000000 |
0-87 | 29.5-0 | 600 | 0-87 | 29.5-0 | 18-30V DC | 1/4 | 3 9/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
0-145 | 29.7-0 | 1,085 | 0-145 | 29.7-0 | 18-30V DC | 1/4 | 3 9/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
0-360 | 29.5-0 | 2,175 | 0-360 | 29.5-0 | 18-30V DC | 1/4 | 3 9/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
BSPP Male | ||||||||||||||||
0-7.3 | 14.8-0 | 145 | 0-7.3 | 14.8-0 | 18-30V DC | 1/4 | 3 11/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
0-14.5 | 1.4-0 | 145 | 0-14.5 | 1.4-0 | 18-30V DC | 1/4 | 3 11/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
0-14.5 | 29.5-0 | 145 | 0-14.5 | 29.5-0 | 18-30V DC | 1/4 | 3 11/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | in. of H2O, in. of Hg, kPa, mbar, psi | 0000000 | 000000 |
0-87 | 29.5-0 | 600 | 0-87 | 29.5-0 | 18-30V DC | 1/4 | 3 11/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
0-145 | 29.7-0 | 1,085 | 0-145 | 29.7-0 | 18-30V DC | 1/4 | 3 11/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
0-360 | 29.5-0 | 145 | 0-360 | 29.5-0 | 18-30V DC | 1/4 | 3 11/16" | 1 3/8" | 1 | 4-20mA | NPN, PNP | 1 | NPN, PNP | bar, MPa, psi | 0000000 | 000000 |
High-Accuracy Pressure and Vacuum Transmitters

- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±0.25%
- Pipe Connection: NPT Male
- Housing Material: 304 Stainless Steel
- Connection Material: 17-4 PH Stainless Steel
- Temperature Range: -40° to 255° F
With an accuracy of ±0.25%, use these transmitters in applications that require highly accurate measurement of both pressure and vacuum, such as activating vacuum pumps. All come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy. They convert pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. As pressure increases, the output signal from the transmitter will increase. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the pressure range and output signal of the transmitter. Transmitters will only provide accurate readings within the rated pressure range.
Rated IP67 and NEMA 4X, these transmitters seal out dust and water from temporary submersion. All are CE marked, so they meet European safety standards.
These transmitters connect using two wires to send a 4-20mA current output. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
For technical drawings and 3-D models, click on a part number.
Transmitters with Calibration Certificate Traceable to NIST | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
4-20mA Current Output—Wire Leads | ||||||||||
0-15 | 29.9-0 | 15 | 30 | 9-30V DC | 1/4 | 2 1/8" | 1" | IP67, NEMA 4X | 0000000 | 0000000 |
0-25 | 29.9-0 | 25 | 50 | 9-30V DC | 1/4 | 2 1/8" | 1" | IP67, NEMA 4X | 0000000 | 000000 |
0-50 | 29.9-0 | 50 | 100 | 9-30V DC | 1/4 | 2 1/8" | 1" | IP67, NEMA 4X | 0000000 | 000000 |
0-100 | 29.9-0 | 100 | 200 | 9-30V DC | 1/4 | 2 1/8" | 1" | IP67, NEMA 4X | 0000000 | 000000 |
Pressure and Vacuum Transmitters for Compressed Air
- For Use With: Air, Argon, Nitrogen
- Accuracy: ±0.2%
- Connection: See table
- Housing Material: Polybutylene Plastic
- Connection Material: Nickel-Plated Brass
- Temperature Range: 25° to 120° F
Specifically made for compressed air and gas systems, these transmitters remotely monitor pressure and vacuum. Also known as transducers, they convert both pressure and vacuum into an electrical signal that can be interpreted by receiving devices, such as remote displays, and motor speed controls. They also have two digital PNP switch outputs that you can connect to your programmable logic controller (PLC) to activate automated controls or alarms when a set pressure or vacuum is reached. Change settings with the buttons on the digital display.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure or vacuum range and output signal. As pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure or vacuum range.
UL and C-UL recognized components, CSA certified, and CE marked, they meet American, Canadian, and European safety standards.
Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Transmitters with voltage output connect using three wires. Two wires connect to the power supply, and a separate wire sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
Add a panel-mounting bracket (sold separately) to mount these switches to a control panel for easy viewing and adjusting.
For technical drawings and 3-D models, click on a part number.

Analog Transmitter Output | Digital Switch Output | Setpoint Range | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Signal | No. of | Signal Type | No. of | Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Pressure, psi | Vacuum, in. of Hg | Input Voltage | Ht. | Wd. | Environmental Rating | Each | |
Wire Leads | |||||||||||||||
1/8 NPT Male Pipe Connection | |||||||||||||||
4-20mA | 1 | PNP | 2 | 0-14.5 | 29-0 | 14.5 | 72 | 0-14.5 | 29-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 000000 |
1-5V DC | 1 | PNP | 2 | 0-14.5 | 29-0 | 14.5 | 72 | 0-14.5 | 29-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
1/4" OD Push-to-Connect Tube Connection | |||||||||||||||
4-20mA | 1 | PNP | 2 | 0-14.5 | 29-0 | 14.5 | 72 | 0-14.5 | 29-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |
1-5V DC | 1 | PNP | 2 | 0-14.5 | 29-0 | 14.5 | 72 | 0-14.5 | 29-0 | 12-24V DC | 1 3/16" | 1 3/16" | IP40 | 0000000 | 00000 |

For Panel Cutout | ||||
---|---|---|---|---|
Ht. | Wd. | Mounting Hole Style | Each | |
1 7/32" | 1 7/32" | Straight | 0000000 | 00000 |
Easy-Setup Pressure and Vacuum Transmitters

- For Use With: Air, Argon, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±0.075%
- Pipe Connection: NPT Male
- Housing Material: Aluminum
- Connection Material: Hastelloy
- Temperature Range: -40° to 180° F
These transmitters automatically compensate for error introduced into both pressure and vacuum measurements by vibrations as well as temperature fluctuations, so you do not need to program corrections for these factors into your receiving device. Use the keypad to set the pressure range, choose the unit of measure, and zero the transmitter. Transmitters convert pressure and vacuum to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. They will only provide accurate readings within the rated pressure or vacuum range.
All transmitters meet IP66 and NEMA 4X for use in washdown environments and have a Hastelloy diaphragm to resist harsh chemicals.
These transmitters typically connect using two wires to send a 4-20mA current output. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices. They can also be configured using three or four wires.
For technical drawings and 3-D models, click on a part number.
Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Communication Protocol | Environmental Rating | Each | |
4-20mA Current Output—Screw Terminals | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
-5-5 | 10-0 | 5 | 145 | 11-55V DC | 1/2 | 5 3/16" | 5 3/16" | HART | IP66, NEMA 4X | 0000000 | 0000000 |
-14.5-30 | 29.5-0 | 30 | 580 | 11-55V DC | 1/2 | 5 3/16" | 5 3/16" | HART | IP66, NEMA 4X | 0000000 | 000000 |
-14.5-150 | 29.5-0 | 150 | 870 | 11-55V DC | 1/2 | 5 3/16" | 5 3/16" | HART | IP66, NEMA 4X | 0000000 | 000000 |
-14.5-450 | 29.5-0 | 450 | 2,175 | 11-55V DC | 1/2 | 5 3/16" | 5 3/16" | HART | IP66, NEMA 4X | 0000000 | 000000 |
-14.5-1,500 | 29.5-0 | 1,500 | 2,900 | 11-55V DC | 1/2 | 5 3/16" | 5 3/16" | HART | IP66, NEMA 4X | 0000000 | 000000 |
Hazardous Location Easy-Setup Pressure and Vacuum Transmitters

- For Use With: Air, Argon, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±0.075%
- Pipe Connection: NPT Male
- Housing Material: Aluminum
- Connection Material: Hastelloy
- Temperature Range: -40° to 180° F
Used in hazardous locations, these transmitters safely convert pressure and vacuum into an electrical signal to measure liquids, gases, and steam. NEC rated for safety, these transmitters are explosion proof, so they can be used in environments containing flammable gases and vapors.
These transmitters automatically compensate for error in both pressure and vacuum measurements caused by vibrations and temperature fluctuations, so you don’t need to separately program corrections into your receiving device. Use the keypad to set the pressure or vacuum range, choose the unit of measure, and zero the transmitter. These transmitters convert pressure and vacuum to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers (PLCs), and motor speed controls, to control equipment or monitor pressure. Transmitters will only provide accurate readings within the rated pressure or vacuum range.
Rated NEMA 4X and IP66, they protect against dirt, dust, rust, harsh weather, and washdowns, and their Hastelloy connection resists corrosive chemicals.
These transmitters commonly connect using two wires to send a 4-20mA current output. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices. Three- and four-wire configurations are also possible.
For technical drawings and 3-D models, click on a part number.
Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Communication Protocol | Environmental Rating | Each | |
4-20mA Current Output—Screw Terminals | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
-5-5 | 10-0 | 5 | 145 | 11-55V DC | 1/2 | 5 1/8" | 4 3/8" | HART | NEC Class I Divisions 1, 2 Groups A, B, C, D; IP66; NEMA 4X | 0000000 | 0000000 |
-14.5-30 | 29.5-0 | 30 | 580 | 11-55V DC | 1/2 | 5 1/8" | 4 3/8" | HART | NEC Class I Divisions 1, 2 Groups A, B, C, D; IP66; NEMA 4X | 0000000 | 000000 |
-14.5-150 | 29.5-0 | 150 | 870 | 11-55V DC | 1/2 | 5 1/8" | 4 3/8" | HART | NEC Class I Divisions 1, 2 Groups A, B, C, D; IP66; NEMA 4X | 0000000 | 000000 |
-14.5-450 | 29.5-0 | 450 | 2,175 | 11-55V DC | 1/2 | 5 1/8" | 4 3/8" | HART | NEC Class I Divisions 1, 2 Groups A, B, C, D; IP66; NEMA 4X | 0000000 | 000000 |
-14.5-1,500 | 29.5-0 | 1,500 | 2,900 | 11-55V DC | 1/2 | 5 1/8" | 4 3/8" | HART | NEC Class I Divisions 1, 2 Groups A, B, C, D; IP66; NEMA 4X | 0000000 | 000000 |
Wireless Pressure and Vacuum Transmitters

- For Use With: Air, Argon, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±1.5%
- Pipe Connection: See table
- Housing Material: Polycarbonate Plastic
- Connection Material: Stainless Steel
- Temperature Range: -4° to 158° F
Monitor your system’s pressure and vacuum from a smartphone or tablet via Bluetooth. These battery-powered transmitters send alerts if equipment requires your attention, so they’re good for preventative maintenance and route-based monitoring. Install the app on your smart device, set your parameters, and monitor pressure and vacuum from up to 300 ft. away. Transmitters let you choose how often you’d like to receive the data. Connect them directly to your equipment with the threaded stem.
For the most precise readings, choose a transmitter that can read slightly above and below your system’s pressure and vacuum range. Transmitters will only provide accurate readings within the rated pressure or vacuum range.
Rated IP65, they're dust tight and are protected against washdowns.
Turn your transmitter into a portable system by adding a quick coupling (not included). Good for on-the-go monitoring, this lets you make fast, temporary connections to equipment in different locations.
For technical drawings and 3-D models, click on a part number.
Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Wireless Range, ft. | Ht. | Wd. | Batteries Included | Environmental Rating | Manufacturer (Series) | Each | |
Bluetooth Connection | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
1/4 NPT Male | |||||||||||
0-14.5 | 29-0 | 14.5 | 29 | 300 | 2 11/16" | 1 7/8" | Yes | IP65 | Parker (Sensonode Blue) | 0000000 | 0000000 |