How to Identify and Measure Fittings
Pipe size is an industry designation, not the actual size. View information about how to measure threaded and unthreaded pipe and pipe fittings.
More
Threaded Swivel Hose Fittings for Water
Use these fittings with power washer guns and in other high-pressure water supply applications. They have ball bearings, so they can swivel 360° before and after installation as needed to prevent hose kinking. Fittings are 416 stainless steel for good corrosion resistance.
For technical drawings and 3-D models, click on a part number.
Quick-Disconnect Hose Couplings for Pressure Testing
Add quick connection points for mechanical gauges and other diagnostic equipment to your line. These couplings are also known as test ports and diagnostic couplings. To take a reading, connect a socket to your gauge using a hose assembly. Then push the socket into a plug that’s permanently threaded into a test port on your line. No threading or unthreading is necessary. Add additional plugs to your line to take measurements at different points. To quickly move the gauge to a different test port, pull back the sleeve on the socket to disengage.
A complete coupling consists of a plug and socket (both sold separately). The plug and socket both have a shut-off valve to stop flow when the coupling is separated, so they're sometimes called double shut-off couplings. They meet ISO 15171-1, which is an international standard for dimensional and performance standards of flat-face diagnostic push-to-connect couplings.
Note: To ensure a correct fit, make sure that the plug and socket have the same coupling size. Pressure ratings are given for static (constant) pressure conditions.
For technical drawings and 3-D models, click on a part number.
- Maximum Pressure: 6,000 psi @ 72° F
- Maximum Vacuum: 27.4 in. of Hg @ 72° F
- Temperature Range: -40° to 250° F
- Compatible With: Parker PD-Series, Eaton/Aeroquip FD90, Faster DF
- Specifications Met: ISO 15171-1, SAE J1502
Plugs are also known as nipples.
- Maximum Pressure: 6,000 psi @ 72° F
- Maximum Vacuum: 27.4 in. of Hg @ 72° F
- Temperature Range: -40° to 250° F
- Compatible With: Parker PD-Series, Eaton/Aeroquip FD90, Faster DF
- Specifications Met: ISO 15171-1, SAE J1502
Plugs are also known as nipples.
- Maximum Pressure: 6,000 psi @ 72° F
- Maximum Vacuum: 27.4 in. of Hg @ 72° F
- Temperature Range: -40° to 250° F
- Compatible With: Parker PD-Series, Eaton/Aeroquip FD90, Faster DF
- Specifications Met: ISO 15171-1, SAE J1502
Plugs are also known as nipples.
UN/UNF (SAE Straight) male threads have a gasket to prevent leaks. They’re also known as O-ring boss threads.
- Maximum Pressure: 6,000 psi @ 72° F
- Maximum Vacuum: 27.4 in. of Hg @ 72° F
- Temperature Range: -40° to 250° F
- Compatible With: Parker PD-Series, Eaton/Aeroquip FD90, Faster DF
- Specifications Met: ISO 15171-1, SAE J1502
Push-to-connect sockets form a coupling when you push the plug into the socket and hear a click. To disconnect, slide the sleeve on the socket forward until the plug ejects.
- Maximum Pressure: 6,000 psi @ 72° F
- Maximum Vacuum: 27.4 in. of Hg @ 72° F
- Temperature Range: -40° to 250° F
- Compatible With: Parker PD-Series, Eaton/Aeroquip FD90, Faster DF
- Specifications Met: ISO 15171-1, SAE J1502
Push-to-connect sockets form a coupling when you push the plug into the socket and hear a click. To disconnect, slide the sleeve on the socket forward until the plug ejects.
For Plug Tip | |||||||
---|---|---|---|---|---|---|---|
Coupling Size | Overall Lg. | Lg. | Dia. | Pipe Size | Dash Size | Each | |
Steel | |||||||
1/8 | 2 1/4" | 3/16" | 1/2" | 1/4 | 04 | 0000000 | 000000 |
Quick-Install Pressure Test Fittings
Male Outlet Adapter with
Intermittent Swivel
NPT Female
Outlet Adapter
Female Outlet Adapter
with Intermittent Swivel
Thread these fittings onto your testing equipment by hand for a secure connection in testing applications—no tools, tape, or sealant required. Use them with gauges and other equipment as a temporary connection. When pressure is applied, the O-ring on the outlet presses against the testing equipment, creating a tight seal.
Adapters with intermittent swivel rotate 360° until tightened for easy installation.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Max. Pressure, psi | Temperature Range, °F | Gasket Material | For Use With | Each | |
NPT Female Inlet × NPT Male Outlet Adapter with Intermittent Swivel | ||||||
---|---|---|---|---|---|---|
416 Stainless Steel | ||||||
1/8 × 1/8 | 5,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 0000000 |
1/4 × 1/4 | 5,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
3/8 × 3/8 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
1/2 × 1/2 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
3/4 × 3/4 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
1 × 1 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
NPT Male Inlet × NPT Female Outlet Adapter | ||||||
416 Stainless Steel | ||||||
1/8 × 1/8 | 5,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
1/4 × 1/4 | 5,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
3/8 × 3/8 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
1/2 × 1/2 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
3/4 × 3/4 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
1 × 1 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
NPT Male Inlet × NPT Female Outlet Adapter with Intermittent Swivel | ||||||
416 Stainless Steel | ||||||
1/8 × 1/8 | 5,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
1/4 × 1/4 | 5,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
3/8 × 3/8 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
1/2 × 1/2 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
3/4 × 3/4 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |
1 × 1 | 4,000 | -65° to 212° | Polyurethane Rubber | Air, Argon, Diesel Fuel, Fuel Oil, Gasoline, Hydraulic Fluid, Hydraulic Fluid (Petroleum Based), Natural Gas, Nitrogen, Oxygen, Water | 0000000 | 000000 |