About Air Preparation
More
Power-Saving Panel-Mount Timer Switches
Push and release the button to activate—no electricity required.
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Set Time | Ht. | Wd. | Dp. | Wire Connection Type | No. of Terminals | Dp. Behind Panel | For Panel Cutout Dia. | For Max. Panel Thick. | Each | |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 10 A @ 120 V AC/240 V AC | 2 sec.-1 min. | 1 7/16" | 1" | 1 1/2" | Solder Lugs | 4 | 1 1/16" | 15/32" | 3/16" | 0000000 | 0000000 |
Timer-Operated Compressed Air Drain Valves
Set the electronic timer on these drain valves to open automatically at your specified time interval. They’re excellent for compressed air systems with high oil content because they resist clogging when water, oil, and sediment combine to form sludge. Install drain valves after separators, dryers, filters, and aftercoolers to collect and remove water from your air line.
Drain valves that meet NEMA 4 are rated for protection from dirt and washdowns. Drain valves that meet NEMA 4X are rated for protection from dirt, washdowns, and corrosion.
Install optional strainers before drain valves to prevent damage from debris in your pipeline.
For technical drawings and 3-D models, click on a part number.
Drain Valves | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Outlet | Overall | Optional Strainers | |||||||||||||||
Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Discharge Cap., gpm | Max. Pressure, psi | Ht. | Wd. | Dp. | Cycle Interval | Drain Time | Max. Temp., °F | Includes | Each | Each | ||
Brass Housing—IP65, NEMA 4 Enclosure | ||||||||||||||||||
Electric Powered, 24V DC—Hardwire | ||||||||||||||||||
1/4 | NPT | Female | 1/4 | NPT | Female | 4.5 | 230 | 4 1/2" | 2" | 3 1/2" | 1-45 min. | 0.5-10 sec. | 130° | __ | 0000000 | 0000000 | 0000000 | 000000 |
3/8 | NPT | Female | 3/8 | NPT | Female | 1.2 | 230 | 4 1/2" | 2" | 3 1/2" | 1-45 min. | 0.5-10 sec. | 130° | __ | 0000000 | 000000 | 0000000 | 00000 |
1/2 | NPT | Female | 1/2 | NPT | Female | 4.5 | 230 | 4 1/2" | 2" | 3 1/2" | 1-45 min. | 0.5-10 sec. | 130° | __ | 0000000 | 000000 | 0000000 | 00000 |
Electric Powered, 120V AC—Three-Prong Plug | ||||||||||||||||||
1/4 | NPT | Female | 1/4 | NPT | Female | 4.8 | 230 | 4 1/4" | 1 3/4" | 3 1/2" | 1-45 min. | 0.5-10 sec. | 130° | __ | 0000000 | 000000 | 0000000 | 00000 |
1/4 | NPT | Female | 1/4 | NPT | Female | 15 | 300 | 4 5/8" | 2 1/2" | 3 5/8" | 1-45 min. | 0.5-10 sec. | 130° | __ | 0000000 | 000000 | 0000000 | 00000 |
3/8 | NPT | Female | 3/8 | NPT | Female | 7 | 230 | 4 1/4" | 1 3/4" | 3 1/2" | 1-45 min. | 0.5-10 sec. | 130° | __ | 0000000 | 000000 | 0000000 | 00000 |
3/8 | NPT | Female | 3/8 | NPT | Female | 19 | 300 | 4 5/8" | 2 1/2" | 3 5/8" | 1-45 min. | 0.5-10 sec. | 130° | __ | 0000000 | 000000 | 0000000 | 00000 |
1/2 | NPT | Female | 1/2 | NPT | Female | 7 | 230 | 4 1/4" | 1 3/4" | 3 1/2" | 1-45 min. | 0.5-10 sec. | 130° | __ | 0000000 | 000000 | 0000000 | 00000 |
1/2 | NPT | Female | 1/2 | NPT | Female | 15 | 300 | 4 5/8" | 2 1/2" | 3 5/8" | 1-45 min. | 0.5-10 sec. | 130° | __ | 0000000 | 000000 | 0000000 | 00000 |
Brass Housing—NEMA 1 Enclosure | ||||||||||||||||||
Electric Powered, 120V AC—Three-Prong Plug | ||||||||||||||||||
1/4 | NPT | Female | 1/4 | NPT | Female | 1.2 | 200 | 3 1/4" | 4" | 4 1/4" | 1-60 min. | 1-30 sec. | 120° | __ | 0000000 | 000000 | 0000000 | 00000 |
Brass Housing—NEMA 4X Enclosure | ||||||||||||||||||
Electric Powered, 120V AC—Three-Prong Plug | ||||||||||||||||||
1/4 | NPT | Female | 1/4 | NPT | Female | 2.9 | 200 | 4 1/8" | 6" | 3 3/4" | 0-50 min. | 1-15 sec. | 180° | Strainer | 0000000 | 000000 | 000000 | 00 |
1/2 | NPT | Female | 1/2 | NPT | Female | 6 | 300 | 4" | 6" | 3 3/4" | 0-50 min. | 1-15 sec. | 180° | Strainer | 00000000 | 000000 | 000000 | 00 |
Electric Powered, 240V AC—Hardwire | ||||||||||||||||||
1/4 | NPT | Female | 1/4 | NPT | Female | 2.9 | 200 | 4 1/8" | 6" | 3 3/4" | 0-50 min. | 1-15 sec. | 180° | Strainer | 0000000 | 000000 | 000000 | 00 |
Replacement Filter Screens for Optional Strainers | 0000000 | Each | 00000 |
Timer-Operated Compressed Air Drain Valves with Digital Display
Use the digital display to set these valves to open automatically at precise intervals. They’re excellent for compressed air systems with high oil content because they resist clogging when water, oil, and sediment combine to form sludge. Install drain valves after separators, dryers, filters, and aftercoolers to collect and remove water from your air line. They meet NEMA 4 for protection from dirt and washdowns.
Install optional strainers before drain valves to prevent damage from debris in your pipeline.
For technical drawings and 3-D models, click on a part number.
Drain Valves | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Outlet | Overall | Optional Strainers | |||||||||||||||
Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Discharge Cap., gpm | Max. Pressure, psi | Ht. | Wd. | Dp. | Cycle Interval | Drain Time | Display Type | Max. Temp., °F | Each | Each | ||
Brass Housing with LED Display—IP65, NEMA 4 Enclosure | ||||||||||||||||||
Electric Powered, 120V AC—Three-Prong Plug | ||||||||||||||||||
1/4 | NPT | Female | 1/4 | NPT | Female | 7 | 230 | 3 3/4" | 1 3/4" | 3 1/2" | 0-99 hrs. | 0-99 hrs. | LED | 130° | 000000 | 0000000 | 0000000 | 000000 |
3/8 | NPT | Female | 3/8 | NPT | Female | 7 | 230 | 3 3/4" | 1 3/4" | 3 1/2" | 0-99 hrs. | 0-99 hrs. | LED | 130° | 000000 | 000000 | 0000000 | 00000 |
1/2 | NPT | Female | 1/2 | NPT | Female | 7 | 230 | 3 3/4" | 1 3/4" | 3 1/2" | 0-99 hrs. | 0-99 hrs. | LED | 130° | 000000 | 000000 | 0000000 | 00000 |
Replacement Filter Screens for Optional Strainers | 0000000 | Each | 00000 |
High-Pressure Timer-Operated Compressed Air Drain Valves
These withstand at least double the pressure of our other timer-operated drain valves. Set the electronic timer to open automatically at your specified time interval. These drain valves are excellent for compressed air systems with high oil content because they resist clogging when water, oil, and sediment combine to form sludge. Install drain valves after separators, dryers, filters, and aftercoolers to collect and remove water from your air line.
Drain valves that meet NEMA 4 are rated for protection from dirt and washdowns. Drain valves that meet NEMA 4X are rated for protection from dirt, washdowns, and corrosion.
Install optional strainers before drain valves to prevent damage from debris in your pipeline.
For technical drawings and 3-D models, click on a part number.
Drain Valves | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Outlet | Overall | Optional Strainers | ||||||||||||||
Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Discharge Cap., gpm | Max. Pressure, psi | Ht. | Wd. | Dp. | Cycle Interval | Drain Time | Max. Temp., °F | Each | Each | ||
Brass Housing—IP65, NEMA 4 Enclosure | |||||||||||||||||
Electric Powered, 120V AC—Three-Prong Plug | |||||||||||||||||
1/4 | NPT | Female | 1/4 | NPT | Female | 3 | 1,200 | 4 1/2" | 2" | 3 3/8" | 1-45 min. | 0.5-10 sec. | 130° | 0000000 | 0000000 | 000000 | 00 |
3/8 | NPT | Female | 3/8 | NPT | Female | 4 | 1,200 | 4 1/2" | 2" | 3 3/4" | 1-45 min. | 0.5-10 sec. | 130° | 0000000 | 000000 | 000000 | 00 |
1/2 | NPT | Female | 1/2 | NPT | Female | 3 | 1,200 | 4 1/2" | 2" | 3 3/8" | 1-45 min. | 0.5-10 sec. | 130° | 0000000 | 000000 | 000000 | 00 |
1/2 | NPT | Female | 1/2 | NPT | Female | 18 | 600 | 6" | 6 3/8" | 3" | 1-24 hrs. | 1-15 min. | 140° | 00000000 | 000000 | 000000 | 00 |
Bronze Housing—NEMA 4X Enclosure | |||||||||||||||||
Electric Powered, 120V AC—Three-Prong Plug | |||||||||||||||||
1/2 | NPT | Female | 1/2 | NPT | Female | 1.25 | 600 | 7" | 7 5/8" | 4" | 1-50 min. | 5 sec. | 180° | 00000000 | 000000 | 0000000 | 000000 |
3/4 | NPT | Female | 3/4 | NPT | Female | 2.5 | 600 | 7 1/2" | 7 5/8" | 4" | 1-50 min. | 5 sec. | 180° | 00000000 | 000000 | 000000 | 00 |
1 | NPT | Female | 1 | NPT | Female | 4.3 | 600 | 7 3/4" | 7 5/8" | 4" | 1-50 min. | 5 sec. | 180° | 00000000 | 000000 | 000000 | 00 |
316 Stainless Steel Housing—NEMA 4X Enclosure | |||||||||||||||||
Electric Powered, 120V AC—Three-Prong Plug | |||||||||||||||||
1/2 | NPT | Female | 1/2 | NPT | Female | 1.25 | 2,000 | 7" | 7 5/8" | 4" | 1-50 min. | 5 sec. | 180° | 00000000 | 000000 | 000000 | 00 |
3/4 | NPT | Female | 3/4 | NPT | Female | 2.5 | 600 | 7 1/2" | 7 5/8" | 4" | 1-50 min. | 5 sec. | 180° | 00000000 | 000000 | 000000 | 00 |
1 | NPT | Female | 1 | NPT | Female | 4.3 | 600 | 7 3/4" | 7 5/8" | 4" | 1-50 min. | 5 sec. | 180° | 00000000 | 000000 | 000000 | 00 |
Replacement Filter Screens for Optional Strainers | 0000000 | Each | 00000 |
Timer-Operated Air On/Off Valves
Install these valves on your air storage tank outlet—at the end of the day, they automatically close to save energy. While in the off position, the tank stays pressurized so the compressor doesn't run when you don't need it to, even if there are small leaks from pipe fittings, drip legs, and other downstream connections. Also known as solenoid valves, these valves actuate when voltage is applied to the electrical connection. They operate on a timer that can be programmed to work with a regular schedule, but they also have a manual override if your schedule changes. They gradually open to prevent system damage from suddenly starting flow.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
For technical drawings and 3-D models, click on a part number.
Cycles | No. of Ports | Pipe Size | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. On/Off, per Week | Timing | Flow | Inlet | Outlet | Inlet | Outlet | Flow Coefficient (Cv) | Max. Pressure, psi | Temp. Range, °F | Voltage | Electrical Connection Type | Cord Lg. | Lg. | Wd. | Ht. | Each | |
NPT Female Inlet × NPT Female Outlet | |||||||||||||||||
Brass Body with LCD Display | |||||||||||||||||
50 | 7 Day | 2 | 1 | 1 | 1 | 1 | 78.8 | 230 | 35° to 140° | 120V AC | Three-Prong Plug | 6 ft. | 2 15/16" | 6 3/16" | 7 5/32" | 0000000 | 0000000 |
Robot-Arm-Mounted Electrically Operated Air On/Off Valves
With two 2-way integrated solenoid valves, these electrically controlled valves direct airflow to venturi pumps, which generate the suction you need to run end-of-arm tools, such as vacuum cups. You can use the two solenoid valves with two different pumps to operate two vacuum cups, or use one valve with a pump and the other to create a burst of air for removing parts that may not drop when the airflow stops, such as those with adhesive on them. All of these valves are curved and have a foam mounting pad that fits collaborative robot arms. Use the hook-and-loop straps to secure them in place—close to your tools, but out of the way.
These valves have a vacuum switch that uses analog and PNP digital feedback to send information about your pump’s vacuum level to your controller. The switch has an LED display that shows the vacuum setting and status. Set and change the vacuum setting with push buttons. These valves have a normally closed starting position, which means airflow is blocked until the valves are actuated. All of the electrical connections you need are included.
Valves with 90° elbow M8 plug will work with FANUC CRX and Universal Robots models. They include a USB flash drive with software for Universal Robots, called URCap, that plugs into your teach pendant to program the valve.
For technical drawings and 3-D models, click on a part number.
For Tube OD, mm | O'all | With Wire Leads | With 90° Elbow M8 Plug | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Outlet | Exhaust | Flow Coefficient (Cv) | Maximum Flow Rate @ 80 psi | Max. Pressure, psi | Temp. Range, °F | Voltage | Lg. | Ht. | Each | For Robot Arm Manufacturer (Series/Model No.) | Each | ||
Push-to-Connect Female Inlet, Outlet, and Exhaust | ||||||||||||||
Plastic Body | ||||||||||||||
6 | 6 | 6 | 0.24 | 6 scfm | 100 | 35° to 120° | 24V DC | 3 1/2" | 4 1/8" | 0000000 | 0000000 | FANUC (CRX 5iA, 10iA, 10iA/L, 20iA/L, 25iA) Universal Robots (UR3; UR3e; UR5; UR5e; UR10; UR10e; UR16; UR16e) | 0000000 | 0000000 |