Air-Inflatable Plugs
Conform to wide and out-of-round pipes with these inflatable plugs. Also known as pneumatic plugs, they're designed for temporary seals since they can lose pressure over time. Inflate with a hand pump (sold separately); an air compressor may overinflate the plug and cause damage. Tether the plugs using either the eyebolt or chain/ring so they don't get lost or stuck in your pipes. Maximum air back pressure is the amount of pressure a plug can withstand without moving. Maximum water back pressure refers to the pressure resulting from the height of the water above the plug.
For Pipe | Deflated | Max. Back Pressure | Material | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Size | ID | Dia. | Ht. | Air, psi | Water, ft. of head | Required Inflation Pressure, psi | Temp. Range, °F | Seal | Chain/Ring | Each | |
3/4 to 1 1/4 | 0.75"-1.30" | 3/4" | 3 3/4" | 17 | 40 | 45 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 000000 |
1 1/4 to 1 1/2 | 1.17"-1.75" | 1 1/8" | 5 1/2" | 13 | 30 | 40 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 000000 | 00000 |
1 1/4 to 2 | 1.25"-2.10" | 1 1/4" | 5 9/16" | 17 | 40 | 40 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 00000 |
2 | 1.90"-2.25" | 1 3/4" | 2 13/16" | 13 | 30 | 40 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 000000 | 00000 |
2 to 3 | 1.90"-3.10" | 1 3/4" | 5 9/16" | 17 | 40 | 35 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 00000 |
2 1/2 | 2.34"-2.75" | 2 5/16" | 4 1/2" | 13 | 30 | 35 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 000000 | 00000 |
3 | 2.77"-3.25" | 2 5/8" | 5 1/4" | 13 | 30 | 35 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 000000 | 00000 |
3 to 4 | 2.80"-4.25" | 2 5/8" | 5 3/16" | 17 | 40 | 40 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 00000 |
4 | 3.41"-4.25" | 3 1/4" | 6 1/2" | 13 | 30 | 30 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 000000 | 00000 |
4 to 6 | 3.40"-6.25" | 3 1/4" | 9 1/2" | 17 | 40 | 30 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 000000 |
5 | 4.60"-5.25" | 4 1/2" | 7 3/4" | 13 | 30 | 30 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 000000 |
6 | 5.44"-6.25" | 5 1/4" | 9" | 13 | 30 | 30 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 000000 | 000000 |
For Pipe | Deflated | Max. Back Pressure | Material | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Size | ID | Dia. | Ht. | Air, psi | Water, ft. of head | Required Inflation Pressure, psi | Temp. Range, °F | Seal | Eyebolt | Each | |
4 to 6 | 3.75"-6.25" | 3 1/2" | 9 13/16" | 17 | 40 | 30 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 0000000 |
4 to 8 | 3.95"-8.25" | 3 1/2" | 23" | 15 | 35 | 45 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 000000 |
6 to 8 | 5.25"-8.25" | 5" | 14" | 17 | 40 | 30 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 000000 |
6 to 12 | 5.50"-12.25" | 5 1/4" | 25" | 15 | 35 | 45 | 0° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 000000 |
8 | 7.00"-8.25" | 6 3/4" | 10 1/4" | 17 | 40 | 25 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 000000 | 000000 |
8 to 12 | 7.00"-12.25" | 6 3/4" | 16" | 11 | 25 | 20 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 000000 |
8 to 12 | 7.50"-12.25" | 6 3/4" | 19 7/8" | 15 | 35 | 45 | 0° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 000000 |
8 to 16 | 7.50"-16.25" | 7 1/4" | 28" | 15 | 35 | 45 | 0° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 000000 |
10 | 9.00"-10.25" | 8 3/4" | 11 3/4" | 17 | 40 | 25 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 000000 | 000000 |
12 | 10.50"-12.25" | 10 1/4" | 13 3/4" | 17 | 40 | 25 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 000000 | 000000 |
12 to 18 | 10.75"-18.25" | 10 3/4" | 25" | 15 | 35 | 45 | 0° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 000000 |
12 to 24 | 11.00"-24.25" | 10 3/4" | 37" | 15 | 35 | 45 | 0° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 00000000 |
16 | 14.00"-16.25" | 13 3/4" | 19 3/4" | 13 | 30 | 25 | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 000000 |
24 to 48 | 20.50"-50.00" | 19" | 84 1/2" | 10 | 23 | 25 | 0° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 00000000 |
Air- and Water-Inflatable Plugs
Penetrate tight pipe junctures with the most flexible expansion plugs we offer. To inflate with air, use a hand pump (sold separately). Whether you fill with air or water, a pressure relief valve will prevent over expanding. Maximum air back pressure is the amount of pressure a plug can withstand without moving. Maximum water back pressure refers to the pressure resulting from the height of the water above the plug.
For Pipe | Deflated | Max. Back Pressure | Water Inlet | Material | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Size | ID | Dia. | Ht. | Air, psi | Water, ft. of head | Required Inflation Pressure, psi | Thread Type | Hose Size | Gender | Temp. Range, °F | Seal | Fitting | Each | |
1 1/2 to 2 | 1.50"-2.00" | 1 3/16" | 7 5/8" | 13 | 30 | 50 | GHT | 3/4 | Female | 35° to 95° | Natural Rubber | Brass | 0000000 | 000000 |
3 to 4 | 2.75"-4.25" | 2 11/16" | 9" | 13 | 30 | 50 | GHT | 3/4 | Female | 35° to 95° | Natural Rubber | Brass | 0000000 | 00000 |
4 to 6 | 3.75"-6.25" | 3 1/2" | 11" | 13 | 30 | 30 | GHT | 3/4 | Female | 35° to 95° | Natural Rubber | Brass | 0000000 | 00000 |
5 to 8 | 4.75"-8.25" | 4 1/2" | 14 1/2" | 13 | 30 | 35 | GHT | 3/4 | Female | 35° to 95° | Natural Rubber | Brass | 0000000 | 000000 |
10 to 12 | 9.75"-12.25" | 6 7/8" | 20" | 11 | 25 | 30 | GHT | 3/4 | Female | 35° to 95° | Natural Rubber | Brass | 0000000 | 000000 |
14 to 16 | 13.75"-16.25" | 8 1/4" | 22" | 11 | 25 | 15 | GHT | 3/4 | Female | 35° to 95° | Natural Rubber | Brass | 0000000 | 000000 |
Air- and Water-Inflatable Plugs for Wye-Joints
These extra-long plugs allow you to seal off two pipes at the same time. They have two separate inflation chambers to release back pressure gradually and prevent splash back as water clears the drain line. To inflate with air, use a hand pump (sold separately). Whether you fill with air or water, a pressure relief valve will prevent over expanding. Maximum air back pressure is the amount of pressure a plug can withstand without moving. Maximum water back pressure refers to the pressure resulting from the height of the water above the plug.
For Pipe | Deflated | Max. Back Pressure | Water Inlet | Material | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Size | ID | Dia. | Ht. | Air, psi | Water, ft. of head | Required Inflation Pressure, psi | Thread Type | Hose Size | Gender | Temp. Range, °F | Seal | Fitting | Includes | Each | |
2 to 3 | 2.00"-3.10" | 1 3/4" | 19 1/2" | 13 | 30 | 60 | GHT | 3/4 | Female | 35° to 95° | Natural Rubber | Brass | 4-ft. Lg. Air Hose | 0000000 | 0000000 |
3 to 4 | 2.75"-4.25" | 2 1/2" | 23 1/2" | 13 | 30 | 60 | GHT | 3/4 | Female | 35° to 95° | Natural Rubber | Brass | 4-ft. Lg. Air Hose | 0000000 | 000000 |
4 to 6 | 4.00"-6.25" | 2 5/8" | 30" | 13 | 30 | 50 | GHT | 3/4 | Female | 35° to 95° | Natural Rubber | Brass | 4-ft. Lg. Air Hose | 0000000 | 000000 |
Air-Inflatable Plugs for Tee Connections
Often used for plumbing tests, these plugs thread into tees and inflate to block flow across the pipe. After your test is complete, deflate the bladder to drain the fluid from your line. Leave the plug installed while the draining the pipe—the threads create a leak-free seal, so no water will splash out. Also known as pneumatic plugs, they can lose pressure over time, so they’re designed for temporary seals. To inflate, use a hand pump (not included) since an air compressor might overinflate and burst them.
Maximum air back pressure is the amount of pressure a plug can withstand without moving. Maximum water back pressure refers to the pressure resulting from the height of the water above the plug.
For Pipe | Deflated | Max. Back Pressure | Material | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Size | ID | Dia. | Ht. | Air, psi | Water, ft. of head | Required Inflation Pressure, psi | Temp. Range, °F | Seal | Thread | Each | |
NPT Male | |||||||||||
1 1/2 | 1.61" | 1 1/2" | 4 3/4" | 13 | 30 | 30 | 0° to 125° | Natural Rubber | ABS Plastic | 0000000 | 000000 |
2 | 2.067" | 2 3/8" | 5 13/16" | 13 | 30 | 35 | 0° to 125° | Natural Rubber | ABS Plastic | 0000000 | 00000 |
3 | 3.068" | 3 1/2" | 7 3/8" | 13 | 30 | 35 | 0° to 125° | Natural Rubber | ABS Plastic | 0000000 | 00000 |
4 | 4.026" | 4 1/2" | 8 1/2" | 13 | 30 | 35 | 0° to 125° | Natural Rubber | ABS Plastic | 0000000 | 00000 |
6 | 6.065" | 6 5/8" | 11" | 13 | 30 | 25 | 0° to 125° | Natural Rubber | ABS Plastic | 0000000 | 000000 |
Air-Inflatable Plugs with Bypass
Conform to wide and out-of-round pipes with these inflatable plugs. Also known as pneumatic plugs, they're designed for temporary seals since they can lose pressure over time. Use the bypass tube on these plugs to add air, water, and other fluid to your pipeline or to relieve pressure while testing.
Inflate with a hand pump (sold separately); an air compressor may overinflate the plug and cause damage. Tether the plugs using either the eyebolt or chain/ring so they don't get lost or stuck in your pipes during installation. Pull on the tether for quick and easy removal once testing is complete.
Maximum air back pressure is the amount of pressure a plug can withstand without moving.
Maximum water back pressure refers to the pressure resulting from the height of the water above the plug.
For Pipe | Deflated | Max. Back Pressure | Bypass | Material | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Size | ID | Dia. | Ht. | Chain Lg., ft. | Air, psi | Water, ft. of head | Required Inflation Pressure, psi | Pipe Size | Thread Type | Gender | Temp. Range, °F | Seal | Chain/Ring | Each | |
1 1/2 | 1.49"-1.88" | 1 3/8" | 3 13/16" | 1 | 22 | 50 | 40 | 1/4 | NPT | Male | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 0000000 |
2 | 1.88"-2.25" | 1 3/4" | 6" | 1 | 22 | 50 | 40 | 1/8 | NPT | Female | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 000000 |
3 | 2.62"-3.25" | 2 1/2" | 8" | 1 | 22 | 50 | 40 | 1/2 | NPT | Female | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 000000 |
For Pipe | Deflated | Max. Back Pressure | Bypass | Material | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Size | ID | Dia. | Ht. | Air, psi | Water, ft. of head | Required Inflation Pressure, psi | Pipe Size | Thread Type | Gender | Temp. Range, °F | Seal | Eyebolt | Each | |
4 | 3.25"-4.25" | 3 1/8" | 8" | 22 | 50 | 40 | 3/4 | NPT | Female | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 0000000 |
6 | 4.50"-6.25" | 4 1/2" | 7" | 13 | 30 | 35 | 1 1/2 | NPT | Female | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 000000 |
8 | 7.00"-8.25" | 6 3/4" | 10" | 13 | 30 | 35 | 3 | NPT | Female | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 000000 |
10 | 9.00"-10.25" | 8 3/4" | 11 3/4" | 13 | 30 | 35 | 3 | NPT | Female | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 000000 |
12 | 10.50"-12.25" | 10 1/4" | 13 3/4" | 13 | 30 | 35 | 3 | NPT | Female | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 000000 |
16 | 14.00"-16.00" | 13 3/4" | 19 3/4" | 13 | 30 | 35 | 3 | NPT | Female | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 0000000 | 000000 |
12 to 24 | 11.25"-24.00" | 11" | 37" | 13 | 30 | 45 | 3 | NPT | Male | -20° to 125° | Natural Rubber | Zinc-Plated Steel | 00000000 | 00000000 |
Water-Powered Drain Cleaners
Flush out clogs with your garden hose. These drain cleaners attach to a hose and expand to form a seal while the water pressure dislodges the blockage.
Rigid cleaners have a ribbed rubber cylinder to grip the inside of your pipe. Crossbar drain adapters can be added to those that are for use with sinks as well as showers/tubs, so they can be used on drains that have crossbars.
Flexible cleaners have a bag-style cylinder that can move through pipe curves and elbows.
Cleaners with a 3/8 NPT male nozzle or NH/NST threads can be capped to convert them into a plug for stopping your line (cap sold separately). Thread a plug (sold separately) into cleaners with NPT threads to use them as plug for stopping your line.
Faucet adapters (sold separately) allow your faucet to accept a 3/4 GHT female connector.
Drain Cleaners | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Connection | Crossbar Drain Adapters | ||||||||||
For Use With | For Pipe ID | Pressure Range, psi | Deflated Lg. | Hose Size | Gender | Cylinder Material | Includes | Each | Each | ||
Rigid | |||||||||||
Floor Drains | 3"-6" | 40-80 | 11" | 3/4 | Female | Rubber | __ | 0000000 | 000000 | 000000 | 00 |
Sewer Pipe | 4"-6" | 40-80 | 11" | 3/4 | Female | Rubber | __ | 00000000 | 00000 | 000000 | 00 |
Sewer Pipe | 6"-10" | 40-80 | 16" | 3/4 | Female | Rubber | __ | 0000000 | 000000 | 000000 | 00 |
Sewer Pipe | 10"-12" | 40-80 | 20" | 3/4 | Female | Rubber | __ | 00000000 | 000000 | 000000 | 00 |
Showers/Tubs, Sinks | 1"-2" | 40-80 | 4 3/4" | 3/4 | Female | Rubber | __ | 0000000 | 00000 | 0000000 | 000000 |
Showers/Tubs, Sinks | 1 1/2"-3" | 40-80 | 6 1/2" | 3/4 | Female | Rubber | __ | 0000000 | 00000 | 0000000 | 00000 |
Sinks | 3/4"-1 1/2" | 40-80 | 5" | 3/4 | Female | Rubber | __ | 00000000 | 00000 | 0000000 | 00000 |
Flexible | |||||||||||
Floor Drains, Garbage Disposals, Grease Traps, Septic Tanks, Showers/Tubs, Toilets | 1 3/8"-1 1/2" | 30-80 | 8 3/4" | 3/4 | Female | Fabric | Backflow Preventer | 0000000 | 00000 | 000000 | 00 |
Floor Drains, Garbage Disposals, Grease Traps, Septic Tanks, Showers/Tubs, Toilets | 1 1/2"-2 1/2" | 30-80 | 9 1/4" | 3/4 | Female | Fabric | Backflow Preventer | 0000000 | 00000 | 000000 | 00 |
Floor Drains, Garbage Disposals, Grease Traps, Septic Tanks, Showers/Tubs, Toilets | 2 1/2"-3" | 30-80 | 13" | 3/4 | Female | Fabric | Backflow Preventer | 0000000 | 00000 | 000000 | 00 |
Floor Drains, Garbage Disposals, Grease Traps, Septic Tanks, Showers/Tubs, Toilets | 3"-4" | 30-80 | 14 3/4" | 3/4 | Female | Fabric | Backflow Preventer | 0000000 | 000000 | 000000 | 00 |
Floor Drains, Garbage Disposals, Grease Traps, Septic Tanks, Showers/Tubs, Toilets | 4"-6" | 30-80 | 20 1/4" | 3/4 | Female | Fabric | 3/8 NPT Male Nozzle | 000000 | 000000 | 000000 | 00 |
Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Use With | For Pipe ID | Pressure Range, psi | Deflated Lg. | Pipe Size | Gender | Cylinder Material | Includes | Each | |
Flexible | |||||||||
Floor Drains, Garbage Disposals, Grease Traps, Septic Tanks, Showers/Tubs, Toilets | 1 3/8"-1 1/2" | 30-100 | 8 3/4" | 1/8 | Female | Fabric | Backflow Preventer | 00000000 | 000000 |
Floor Drains, Garbage Disposals, Grease Traps, Septic Tanks, Showers/Tubs, Toilets | 1 3/8"-2 1/2" | 30-100 | 9 1/4" | 1/8 | Female | Fabric | Backflow Preventer | 00000000 | 00000 |
Floor Drains, Garbage Disposals, Grease Traps, Septic Tanks, Showers/Tubs, Toilets | 2 1/2"-3" | 30-100 | 13" | 1/4 | Female | Fabric | Backflow Preventer | 00000000 | 000000 |
Floor Drains, Garbage Disposals, Grease Traps, Septic Tanks, Showers/Tubs, Toilets | 3"-4" | 30-100 | 14 3/4" | 1/4 | Female | Fabric | Backflow Preventer | 00000000 | 000000 |
Floor Drains, Garbage Disposals, Grease Traps, Septic Tanks, Showers/Tubs, Toilets | 4"-6" | 30-100 | 20 1/4" | 1/4 | Female | Fabric | Backflow Preventer | 00000000 | 000000 |
Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Use With | For Pipe ID | Pressure Range, psi | Deflated Lg. | Fire Hose Trade Size | Gender | Swivel Type | Cylinder Material | Each | |
Flexible | |||||||||
Floor Drains, Garbage Disposals, Grease Traps, Septic Tanks, Showers/Tubs, Toilets | 5"-8" | 30-100 | 25" | 2 1/2 | Female | Swivels Until Tightened | Fabric | 00000000 | 0000000 |
Floor Drains, Garbage Disposals, Grease Traps, Septic Tanks, Showers/Tubs, Toilets | 5"-10" | 30-100 | 37" | 2 1/2 | Female | Swivels Until Tightened | Fabric | 00000000 | 000000 |
Stainless Steel Cap for 2623K106 and 2623K107 | 00000000 | Each | 000000 |
Water-Powered Drain Cleaning Kits
Flush out clogs with a garden hose. These drain cleaners attach to the included hose and expand to form a seal while the water pressure dislodges the blockage. Its ribbed cylinder grips the inside of the pipe. Also includes a faucet adapter that allows you to connect the hose to your faucet.
Connection | Hose | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Pipe ID | For Use With | Cylinder Material | Hose Size | Thread Type | Gender | Lg., ft. | Size | Thread Type | Gender | No. of Drain Cleaners | Includes | Each | |
Rigid | |||||||||||||
1"-6" | Floor Drains, Showers/Tubs, Sinks | Rubber | 3/4 | GHT | Female | 10 | 3/4 | GHT | Female × Male | 3 | Carrying Case, Crossbar Drain Adapter, Faucet Adapter | 0000000 | 000000 |