How to Prime Your Pump
More
How to Determine Feet of Head
More
About Process Pumps
More
Fixed-Flow-Rate Metering Pumps for Chemicals
Also known as peristaltic pumps and tubing pumps, these maintain a fixed flow rate. Pumps are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Mount them up to 25 feet above your liquid source. All can run dry. Do not use with solids.

Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gal./day (For Tube ID) | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Lg. | Wd. | Ht. | Includes | Each | |
120V AC/240V AC,Single Phase—Plug | |||||||||||
Norprene and Santoprene Rubber Wetted Parts Material | |||||||||||
6.00 (1/8") 12.00 (3/16") 20.00 (1/4") | 25 | 5,000 | 33° to 104° | Not Rated | 2 | 5 5/8" | 6 1/4" | 5 3/4" | 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60), 9" Lg. of 1/4" ID Norprene Tubing (Shore A60) | 000000000 | 0000000 |
26.00 (1/8") 56.00 (3/16") 91.00 (1/4") | 25 | 5,000 | 33° to 104° | Not Rated | 2 | 5 5/8" | 6 1/4" | 5 3/4" | 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60), 9" Lg. of 1/4" ID Norprene Tubing (Shore A60) | 000000000 | 000000 |
42.00 (1/8") 88.00 (3/16") 144.00 (1/4") | 25 | 5,000 | 33° to 104° | Not Rated | 2 | 5 5/8" | 6 1/4" | 5 3/4" | 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60), 9" Lg. of 1/4" ID Norprene Tubing (Shore A60) | 000000000 | 000000 |
77.00 (1/8") 162.00 (3/16") 265.00 (1/4") | 25 | 5,000 | 33° to 104° | Not Rated | 2 | 5 5/8" | 6 1/4" | 5 3/4" | 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60), 9" Lg. of 1/4" ID Norprene Tubing (Shore A60) | 000000000 | 000000 |
122.00 (1/8") 257.00 (3/16") 421.00 (1/4") | 25 | 5,000 | 33° to 104° | Not Rated | 2 | 5 5/8" | 6 1/4" | 5 3/4" | 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60), 9" Lg. of 1/4" ID Norprene Tubing (Shore A60) | 000000000 | 000000 |
For Maximum Viscosity, cP | Each | |
5,000 | 000000000 | 0000000 |
For Flow Rate, gal./day | Each | |
For Norprene and Santoprene Wetted Parts Material | ||
---|---|---|
1-376 | 00000000 | 000000 |
Panel-Mount Fixed-Flow-Rate Metering Pumps for Chemicals

Install these pumps in a panel cutout. Often used in food and beverage, pharmaceutical, and lab applications, they dispense small amounts of liquid at a set rate. Pumps can be wired to a switch for manual operation, or a PLC for automated equipment. The removable pump head includes an intake tube that quickly connects to your line with barbed fittings (not included). To change lines, disconnect tubing and twist and pull the head off the motor. Then twist on a replacement head (sold separately). Pumps come in three colors for easy identification or to match your existing equipment. All are self-priming and create suction to draw liquid upward. Mount pumps up to 28 ft. above your liquid source. They can run dry.
Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, ml/min. | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Wd. | Ht. | Dp. | Each | |
Blue | ||||||||||
24V DC | ||||||||||
Hardwire | ||||||||||
55 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 0000000 |
160 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
Clear | ||||||||||
24V DC | ||||||||||
Hardwire | ||||||||||
55 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
160 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
Green | ||||||||||
24V DC | ||||||||||
Hardwire | ||||||||||
55 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
160 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
High-Viscosity Metering Pumps for Chemicals


Rated for liquids with a viscosity up to 5,000 centipoise, these pumps can be used with thick chemicals such as electropolishing solutions. An adjustment dial allows you to alter flow rate in 2.5% increments of the maximum flow without the hassle of changing tubing. Often used in boiler feed systems and water treatment, they're compatible with chemicals such as cleaning fluids and acid-washing solutions. Pumps are self-priming and create suction to draw liquid upward. They can run dry.
Pumps | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube | Overall | Replacement Tubing | ||||||||||||
Flow Rate, gal./day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Current, A | ID | OD | Lg. | Wd. | Ht. | Includes | Each | Each | ||
120V AC/240V AC, Single Phase—With Open Intake and Discharge Connections | ||||||||||||||
Plug | ||||||||||||||
0.2-21 | 25 | 5,000 | 33° to 104° | 2 | 1/8", 3/16", 1/4" | 3/8", 7/16" | 5 5/8" | 6 1/4" | 5 3/4" | 9" Lg. of 1/4" ID Norprene Tubing (Shore A60), 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60) | 000000000 | 0000000 | 00000000 | 000000 |
0.9-97 | 25 | 5,000 | 33° to 104° | 2 | 1/8", 3/16", 1/4" | 3/8", 7/16" | 5 5/8" | 6 1/4" | 5 3/4" | 9" Lg. of 1/4" ID Norprene Tubing (Shore A60), 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60) | 000000000 | 000000 | 00000000 | 00000 |
4-449 | 25 | 5,000 | 33° to 104° | 2 | 1/8", 3/16", 1/4" | 3/8", 7/16" | 5 5/8" | 6 1/4" | 5 3/4" | 9" Lg. of 1/4" ID Norprene Tubing (Shore A60), 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60) | 000000000 | 000000 | 00000000 | 00000 |
5.7-579 | 25 | 5,000 | 33° to 104° | 0.22 | 1/8", 3/16", 1/4" | 3/8", 7/16" | 8 13/16" | 7 1/8" | 5 1/2" | 9" Lg. of 1/4" ID Norprene Tubing (Shore A60), 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60) | 000000000 | 000000 | 00000000 | 00000 |
28-847 | 20 | 5,000 | 33° to 95° | 2 | 3/8" | 5/8" | 10 1/4" | 6 1/4" | 7 1/4" | 14" Lg. of 3/8" ID Norprene Tubing (Shore A60) | 000000000 | 000000 | 00000000 | 00000 |
High-Flow Metering Pumps for Chemicals

For high-volume chemical sampling and draining, these pumps have a powerful motor that enables them to move 2,592 gallons of liquid per day. They're commonly used with ammonia, acid-washing solutions, and cleaning fluids. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Pumps are self-priming and create a suction force to draw liquid upward. Mount up to 15 feet above your liquid source. They can run dry. Do not use with solids.
Intake | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gal./day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | For Tube ID | Tube Connection Type | For Tube ID | Tube Connection Type | Lg. | Wd. | Ht. | Includes | Each | |
120V AC, Single Phase | |||||||||||||||
Plug | |||||||||||||||
2,592 | 20 | 1,000 | 35° to 160° | 1/4 hp | 3.1 | 1/2" | Barbed | 1/2" | Barbed | 10" | 5 1/2" | 10" | 10 5/8" Lg. of 1/2" ID Tygon Tubing (Shore A61) | 0000000 | 0000000 |
Metering Pumps for Chemicals

An adjustment screw lets you increase or decrease flow rate without the hassle of changing tubing. Often used in boiler feed systems and water treatment, these pumps are compatible with chemicals such as cleaning fluids and acid-washing solutions. Pumps are self-priming and create suction to draw liquid upward. They can run dry.
Pumps | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube | Overall | Replacement Collars | Replacement Tubing | ||||||||||||||
Flow Rate, gal./day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | ID | OD | Lg. | Wd. | Ht. | Includes | Each | Each | Each | |||
120V AC, Single Phase | |||||||||||||||||
Plug | |||||||||||||||||
2-12 | 25 | 200 | 35° to 100° | 1/64 hp | 0.3 | 3/16" | 3/8" | 8" | 7" | 6" | 9" Lg. of Tygon Tubing (Shore A70) | 00000000 | 0000000 | 00000000 | 000000 | 00000000 | 000000 |
3-20 | 25 | 200 | 35° to 100° | 1/64 hp | 0.3 | 1/4" | 7/16" | 8" | 7" | 6" | 9" Lg. of Tygon Tubing (Shore A70) | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 00000 |
Replacement Pump Head | 00000000 | Each | 000000 |
High-Pressure Metering Pumps for Chemicals

These pumps can be used with pressures four times higher than standard pumps. An adjustment dial lets you alter flow rate in 2.5% increments of the maximum flow without the hassle of changing tubing. Often used in boiler feed systems and water treatment, they're compatible with chemicals such as cleaning fluids and acid-washing solutions. Pumps are self-priming and create suction to draw liquid upward. They can run dry.
Pumps | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Discharge | Overall | Replacement Pump Heads | Replacement Tubing | ||||||||||||||
Flow Rate, gal./day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Tube ID | Tube OD | Lg. | Wd. | Ht. | Includes | Each | Each | Each | |||
120V AC, Single Phase | |||||||||||||||||
Plug | |||||||||||||||||
0.3-5 | 100 | 1,500 | 35° to 125° | 1/30 hp | 1.7 | 3/16" | 1/4" | 11" | 5" | 6" | 20-ft. Lg. of LDPE Plastic Intake/Discharge Tubing | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 | 000000 |
0.8-17 | 100 | 1,500 | 35° to 125° | 1/30 hp | 1.7 | 3/16" | 1/4" | 11" | 5" | 6" | 20-ft. Lg. of LDPE Plastic Intake/Discharge Tubing | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 00000 |
2-40 | 100 | 1,500 | 35° to 125° | 1/30 hp | 1.7 | 3/16" | 1/4" | 11" | 5" | 6" | 20-ft. Lg. of LDPE Plastic Intake/Discharge Tubing | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 00000 |