Panel-Mount Timer Switches


Install these switches in a panel cutout to automatically turn electrical equipment on or off after a set interval.
Switches with set time recall retain the last setting; push the button to start the timer over at the same interval, eliminating the need to reset the dial with every use.
Wire Leads | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Set Time | Input Voltage | Dia. | Dp. | For Panel Cutout Dia. | For Max. Panel Thick. | Wire Connection Type | No. of Terminals | No. of | Lg. | Each | |
Dial Reset | ||||||||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 min.-30 min. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 0000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 hrs.-12 hrs. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 hrs.-60 hrs. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 2 hrs.-24 hrs. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 5 min.-60 min. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 20 A @ 120 V AC/240 V AC | 1 min.-15 min. | 120V AC/240V AC | 2 9/16" | 1 9/16" | 13/32" | 1/8" | Screw Terminals | 3 | __ | __ | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 20 A @ 120 V AC/240 V AC | 1 min.-30 min. | 120V AC/240V AC | 2 3/4" | 1 5/8" | 2 19/32" | 1/4" | Screw Terminals | 3 | __ | __ | 0000000 | 000000 |
Push Reset with Set Time Recall | ||||||||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 min.-30 min. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 hrs.-12 hrs. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 hrs.-60 hrs. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 2 hrs.-24 hrs. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 5 min.-60 min. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
Replacement Knob for 20A Switches | 0000000 | Each | 00000 |
Power-Saving Panel-Mount Timer Switches

Push and release the button to activate—no electricity required.
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Set Time | Ht. | Wd. | Dp. | Wire Connection Type | No. of Terminals | Dp. Behind Panel | For Panel Cutout Dia. | For Max. Panel Thick. | Each | |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 10 A @ 120 V AC/240 V AC | 2 sec.-1 min. | 1 7/16" | 1" | 1 1/2" | Tab Terminals | 4 | 1 1/16" | 15/32" | 3/16" | 0000000 | 0000000 |
Panel-Mount Set-to-the-Minute Time and Day Activated Switches


Install these switches in a panel cutout. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. The seven-day timing cycle can perform a different program each day of the week. All have an override to bypass the programmed on/off settings. A backup battery maintains the program during a power outage.
Two-circuit switches can apply a different program to each circuit.
For Panel Cutout | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Industry Designation | Ht. | Wd. | Dp. | Ht. | Wd. | Wire Connection Type | Each | |
7-Day Timing Cycle | ||||||||||||||
1 | 15 A @ 277 V AC | 12V AC/24V AC/24V DC | 20 per Day | 1 min. | Push Button | SPDT | 2.8" | 2.8" | 1.5" | 2.63" | 2.63" | Screw Terminals | 00000000 | 0000000 |
1 | 15 A @ 277 V AC | 120V AC/277V AC | 20 per Day | 1 min. | Push Button | SPDT | 2.8" | 2.8" | 1.5" | 2.63" | 2.63" | Screw Terminals | 000000000 | 000000 |
2 | 15 A @ 250 V AC | 120V AC/240V AC | 20 per Day | 1 min. | Push Button | SPST-NO | 2.8" | 2.8" | 2.2" | 2.68" | 2.68" | Screw Terminals | 00000000 | 000000 |
Surface/DIN-Rail Mount Set-to-the-Minute Time and Day Activated Switches


Mount these switches to a flat surface or attach to DIN rail. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. All have an override to bypass the programmed on/off settings. A backup battery maintains the program during a power outage.
24-hour switches repeat the same program daily. They control two circuits and can apply a different program to each circuit.
Seven-day switches can perform a different program each day of the week.
Mounting | For Panel Cutout | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Industry Designation | Ht. | Wd. | Dp. | Fasteners Included | No. of Holes | For DIN Rail Ht., mm | Ht. | Wd. | Wire Connection Type | Each | |
24-Hour Timing Cycle | |||||||||||||||||
2 | 15 A @ 250 V AC | 120V AC/240V AC | 12 per Day | 1 min. | Push Button | SPST-NO | 3.8" | 3.8" | 2.2" | No | 2 | 35 | 3.62" | 3.62" | Screw Terminals | 00000000 | 0000000 |
7-Day Timing Cycle | |||||||||||||||||
1 | 15 A @ 277 V AC | 12V AC/24V AC/24V DC | 20 per Day | 1 min. | Push Button | SPDT | 4.1" | 2.9" | 2.2" | __ | __ | __ | __ | __ | Screw Terminals | 000000000 | 000000 |
1 | 15 A @ 277 V AC | 120V AC/277V AC | 20 per Day | 1 min. | Push Button | SPDT | 4.1" | 2.9" | 2.2" | __ | __ | __ | __ | __ | Screw Terminals | 000000000 | 000000 |
1 | 15 A @ 277 V AC | 120V AC/277V AC | 50 per Day | 1 min. | Push Button | SPDT | 4.1" | 2.9" | 2.2" | __ | __ | __ | __ | __ | Screw Terminals | 000000000 | 000000 |
Panel-Mount Time and Day Activated Switches

Install these switches in a panel cutout and program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times. As UL and C-UL Recognized Components that are also CE Marked, these switches meet American, Canadian, and European safety standards.
24-hour switches repeat the same program daily.
Seven-day switches can perform a different program each day of the week. They come with an override to bypass their programmed settings.
For Panel Cutout | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Tripper Type | With Override | Industry Designation | Ht. | Wd. | Dp. | Ht. | Wd. | Wire Connection Type | Specifications Met | Each | |
24-Hour Timing Cycle | |||||||||||||||||
1 | 21 A @ 250 V AC | 120V AC | 48 per Day | 15 min. | Trippers | Captive | __ | SPDT | 2.8" | 2.8" | 1.5" | 2.63" | 2.63" | Quick-Disconnect Terminals | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 0000000 | 000000 |
7-Day Timing Cycle | |||||||||||||||||
1 | 21 A @ 250 V AC | 120V AC | 6 per Day | 2 hrs. | Trippers | Captive | With Override | SPDT | 2.8" | 2.8" | 1.5" | 2.63" | 2.63" | Quick-Disconnect Terminals | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 0000000 | 000000 |