About Motor Switches and Starters
More
Build-Your-Own Manual Motor Starters

Indicating Light
and Steel Wall Plate

Power Indicating
Light and Steel Housing


Assemble your own motor starter by combining a switch and a thermal overload element.
Thermal overload elements shut motors off if current exceeds the full-load current rating. To Order: Please specify the full-load current rating of your motor. If the full-load current rating is not shown on the motor’s faceplate, estimate the current rating (given the motor’s horsepower and voltage).
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Electrical Phase (hp) | Ht. | Wd. | Wire Connection Type | Environment | Environmental Rating | Each | |
With Power-Indicating Light | ||||||||
---|---|---|---|---|---|---|---|---|
Steel Wall Plate | ||||||||
2 | Single (3/4 hp @ 115 V DC) Single (3/4 hp @ 230 V DC) Single (1 hp @ 115 V AC) Single (1 hp @ 230 V AC) | 4.5" | 2.8" | Screw Terminals | Indoor Only | __ | 0000000 | 0000000 |
Steel Housing | ||||||||
1 | Single (1 hp @ 115 V AC) Single (1 hp @ 230 V AC) | 4.3" | 2.8" | Screw Terminals | Indoor Only | NEMA 1 | 0000000 | 000000 |
2 | Single (3/4 hp @ 115 V DC) Single (3/4 hp @ 230 V DC) Single (1 hp @ 115 V AC) Single (1 hp @ 230 V AC) | 4.3" | 2.8" | Screw Terminals | Indoor Only | NEMA 1 | 0000000 | 000000 |
Without Power-Indicating Light | ||||||||
Steel Wall Plate | ||||||||
1 | Single (1 hp @ 115 V AC) Single (1 hp @ 230 V AC) | 4.5" | 2.8" | Screw Terminals | Indoor Only | __ | 0000000 | 00000 |
Steel Housing | ||||||||
1 | Single (1 hp @ 115 V AC) Single (1 hp @ 230 V AC) | 4.3" | 2.8" | Screw Terminals | Indoor Only | NEMA 1 | 0000000 | 000000 |
2 | Single (3/4 hp @ 115 V DC) Single (3/4 hp @ 230 V DC) Single (1 hp @ 115 V AC) Single (1 hp @ 230 V AC) | 4.3" | 2.8" | Screw Terminals | Indoor Only | NEMA 1 | 0000000 | 000000 |
Enclosed Heavy Duty Build-Your-Own Manual Motor Starters
Combine a switch with a thermal overload element to build a starter that can handle high-current-rated motors. All are housed in a durable steel enclosure. They’re also known as NEMA starters.
NEMA 12 rated switches are protected from oil/coolant dripping.
Thermal overload elements shut motors off if current exceeds the full-load current rating. Three elements are required. To Order: Please specify the full-load current rating of your motor. If the full-load current rating is not shown on the motor’s faceplate, estimate the current rating (given the motor’s horsepower and voltage).
For technical drawings and 3-D models, click on a part number.


NEMA Contact Size | Electrical Phase (hp) | Housing Material | Ht. | Wd. | Dp. | Wire Connection Type | Environment | Environmental Rating | Specifications Met | Each | |
NEMA 1 Motor Starters | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
M0 | Three (2 hp @ 115 V AC) Three (3 hp @ 230 V AC) Three (5 hp @ 460 V AC) | Painted Steel | 7.6" | 4.7" | 5" | Screw Terminals | __ | NEMA 1 | UL Listed, CSA Certified | 0000000 | 0000000 |
M1 | Three (3 hp @ 115 V AC) Three (7 1/2 hp @ 230 V AC) Three (10 hp @ 460 V AC) | Painted Steel | 7.6" | 4.7" | 5" | Screw Terminals | __ | NEMA 1 | UL Listed, CSA Certified | 0000000 | 00000000 |
NEMA 12 Motor Starters | |||||||||||
M0 | Three (2 hp @ 115 V AC) Three (3 hp @ 230 V AC) Three (5 hp @ 460 V AC) | Painted Steel | 9.4" | 5.5" | 5" | Screw Terminals | Oily | NEMA 12 | UL Listed, CSA Certified | 0000000 | 00000000 |
M1 | Three (3 hp @ 115 V AC) Three (7 1/2 hp @ 230 V AC) Three (10 hp @ 460 V AC) | Painted Steel | 9.4" | 5.5" | 5" | Screw Terminals | Oily | NEMA 12 | UL Listed, CSA Certified | 0000000 | 00000000 |

Each | ||
000000 | 000000 |
Heavy Duty Build-Your-Own Manual Motor Starters
Combine a switch and a thermal overload element to build a starter that can handle high-current-rated motors. They’re also known as NEMA starters.
Thermal overload elements shut motors off if current exceeds the full-load current rating. Three elements are required. To Order: Please specify the full-load current rating of your motor. If the full-load current rating is not shown on the motor’s faceplate, estimate the current rating (given the motor’s horsepower and voltage).
For technical drawings and 3-D models, click on a part number.

Each | ||
000000 | 000000 |
Energy-Saving Motor Starters

Save electricity and extend motor life by reducing the motor's starting current. These starters gradually start and stop motors. Use them on motors where torque varies, such as pumps, compressors, and conveyors. All have an auxiliary contact to send a signal or connect to another device, such as an alarm or indicating light.
For technical drawings and 3-D models, click on a part number.
Switching | Time, sec. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Full Load Current, A | Input Voltage | Voltage | Current | Electrical Phase (hp) | Acceleration | Deceleration | Ht. | Wd. | Mount. Location | For DIN Rail Ht., mm | Each | |
Motor Starters with 1 Auxiliary Contact—1 Off (Normally Open) | ||||||||||||
3 | 24V DC | 208-600V AC | 3A | Three (3/4 hp @ 240 V AC) Three (2 hp @ 480 V AC) | 1-20 | 0-20 | 4.7" | 1.8" | DIN Rail, Surface | 35 | 000000 | 0000000 |
9 | 24V DC | 208-600V AC | 9A | Three (2 hp @ 240 V AC) Three (5 hp @ 480 V AC) | 1-20 | 0-20 | 5.5" | 1.8" | DIN Rail, Surface | 35 | 0000000 | 000000 |
15 | 24V DC | 208-600V AC | 16A | Three (5 hp @ 240 V AC) Three (10 hp @ 480 V AC) | 1-20 | 0-20 | 5.5" | 1.8" | DIN Rail, Surface | 35 | 0000000 | 000000 |
28 | 24V DC | 208-600V AC | 30A | Three (10 hp @ 240 V AC) Three (20 hp @ 480 V AC) | 1-20 | 0-20 | 6.3" | 1.8" | DIN Rail, Surface | 35 | 0000000 | 000000 |
59 | 24V DC | 208-600V AC | 60A | Three (20 hp @ 240 V AC) Three (40 hp @ 480 V AC) | 1-20 | 0-20 | 8.7" | 2.8" | Surface | __ | 0000000 | 000000 |
Overload Protectors for Motor Starters

Upgrade motor starters that use thermal overload protection with these solid-state overloads—they don't use heating elements, so enclosure ventilation and cooling is not required. All have a full-load amp adjustment dial to accommodate circuits with different full-load amp ratings.
If the full-load amp rating is not shown on your motor’s faceplate, estimate the current rating (given the motor’s horsepower and voltage).
For technical drawings and 3-D models, click on a part number.
Overload Current, A | Trip Time, sec. | Overload Protection Class | Motor Protection | Ht. | Wd. | Dp. | Wire Connection Type | Specifications Met | Each | |
2 Auxilliary Contacts with 1 Off (Normally Open), 1 On (Normally Closed) | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Single Phase | ||||||||||
3-12 | 5, 10, 20, 30 | 5, 10, 20, 30 | Overvoltage, Phase Loss | 2.2" | 3.5" | 3.2" | Screw Terminals | UL Listed, CSA Certified | 0000000 | 0000000 |
5.5-22 | 5, 10, 20, 30 | 5, 10, 20, 30 | Overvoltage, Phase Loss | 2.2" | 3.5" | 3.2" | Screw Terminals | UL Listed, CSA Certified | 0000000 | 000000 |
Three Phase | ||||||||||
0.75-3.4 | 5, 10, 20, 30 | 5, 10, 20, 30 | Overvoltage, Phase Loss | 3.2" | 3.5" | 3.2" | Screw Terminals | UL Listed, CSA Certified | 0000000 | 000000 |
3-12 | 5, 10, 20, 30 | 5, 10, 20, 30 | Overvoltage, Phase Loss | 2.2" | 3.5" | 3.2" | Screw Terminals | UL Listed, CSA Certified | 0000000 | 000000 |
5.5-22 | 5, 10, 20, 30 | 5, 10, 20, 30 | Overvoltage, Phase Loss | 2.2" | 3.5" | 3.2" | Screw Terminals | UL Listed, CSA Certified | 0000000 | 000000 |
10-40 | 5, 10, 20, 30 | 5, 10, 20, 30 | Overvoltage, Phase Loss | 2.2" | 3.5" | 3.2" | Screw Terminals | UL Listed, CSA Certified | 0000000 | 000000 |
13-52 | 5, 10, 20, 30 | 5, 10, 20, 30 | Overvoltage, Phase Loss | 2.3" | 4.5" | 4" | Screw Terminals | UL Listed, CSA Certified | 0000000 | 000000 |