About NEMA Straight-Blade Plugs, Connectors, and Receptacles
More
About NEMA Plugs, Sockets, and Receptacles
More
Straight-Blade Plugs, Sockets, and Receptacles
90° elbow plugs with a rotating face can be plugged in at any angle.
Receptacles for outlet boxes fit standard wall plates (not included).
Note: The current rating of your plug should not exceed that of your socket or receptacle.
For technical drawings and 3-D models, click on a part number.



Premium Straight-Blade Plugs, Sockets, and Receptacles
Built to handle tough, repetitive-use applications, these are more durable than standard straight-blade connectors.
Receptacles for outlet boxes fit standard wall plates (not included).
Note: The current rating of your plug should not exceed that of your socket or receptacle.
For technical drawings and 3-D models, click on a part number.




NEMA Style | Voltage | Current | OD | Wire Connection Type | For Cable OD | Environmental Rating | Specifications Met | Color | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
14-60 | 125V AC/250V AC | 60A | 2.9" | Screw Terminals | 0.63"-1.31" | IP20 | UL Listed, CSA Certified, UL 94 HB | Black | 0000000 | 0000000 |
15-60 | 250V AC | 60A | 2.9" | Screw Terminals | 0.63"-1.31" | IP20 | UL Listed, CSA Certified, UL 94 HB | Black | 0000000 | 000000 |
Non-Grounded | ||||||||||
18-60 | 120V AC/208V AC | 60A | 2.9" | Screw Terminals | 0.63"-1.31" | IP20 | UL Listed, UL 94 HB | Black | 0000000 | 000000 |




NEMA Style | Voltage | Current | Wd. | Wire Connection Type | For Cable OD | Specifications Met | Color | Each | |
Grounded | |||||||||
---|---|---|---|---|---|---|---|---|---|
14-60 | 125V AC/250V AC | 60A | 3.4" | Screw Terminals | 0.63"-1.31" | UL Listed, CSA Certified, UL 498, Fed. Spec. W-C-596G | Black | 0000000 | 0000000 |
15-60 | 250V AC | 60A | 3.4" | Screw Terminals | 0.63"-1.31" | UL Listed, CSA Certified, UL 498 | Black | 0000000 | 000000 |
Non-Grounded | |||||||||
18-60 | 120V AC/208V AC | 60A | 3.4" | Screw Terminals | 0.63"-1.31" | UL Listed, UL 498 | Black | 0000000 | 000000 |




NEMA Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Environmental Rating | Specifications Met | Color | Each | |
Grounded | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
14-60 | 125V AC/250V AC | 60A | 2.4" | Screw Terminals | Back, Side | Outlet Box | IP20 | UL Listed, CSA Certified, UL 94 V-0 | Black | 0000000 | 0000000 |
15-60 | 250V AC | 60A | 2.4" | Screw Terminals | Back, Side | Outlet Box | IP20 | UL Listed, CSA Certified, UL 94 V-0 | Black | 0000000 | 000000 |
Non-Grounded | |||||||||||
18-60 | 120V AC/208V AC | 60A | 2.3" | Screw Terminals | Back, Side | Outlet Box | IP20 | UL Listed, CSA Certified, UL 94 HB | Black | 0000000 | 000000 |
IEC Safe-Break Pin-and-Sleeve Connectors
These connectors meet international standards IEC 309-1 and 309-2, so they’re compatible with other IEC 309 devices. They allow you to connect and disconnect with the power on—spring-loaded contacts open like a switch when separating the connectors, preventing an electrical arc. All are approved as switch-rated connectors for branch and motor circuit disconnect switching. Connectors have a ground pin that is included in the number of wires. Rated NEMA 4X, 12, and IP69K, they're protected against corrosion, oil/coolant seepage, washdowns, and high-temperature, high-pressure washdowns.


2W3P
Male

2W3P
Male

3W4P
Male

AC,
4W5P Male

3W4P
Male
Face Dia. | No. of Poles | No. of Ground Connections | No. of Wires | Industry Designation | Electrical Phase | Current | Wire Connection Type | For Wire Gauge | For Cable OD | Temp. Range, °F | Environmental Rating | Choose a Voltage | Each | |
2.5" | 3 | 1 | 2 | 2W3P | Single | 60A | Screw Terminals | 8-2 | 0.5"-1.45" | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 0000000 | 0000000 | |
2.5" | 4 | 1 | 3 | 3W4P | Three | 60A | Screw Terminals | 8-2 | 0.5"-1.45" | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 0000000 | 000000 | |
2.5" | 5 | 1 | 4 | 4W5P | Three | 60A | Screw Terminals | 8-2 | 0.5"-1.45" | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 277V AC/480V AC | 0000000 | 000000 |


2W3P
Female

2W3P
Female

3W4P
Female

AC,
4W5P Female

3W4P
Female
Face Dia. | No. of Poles | No. of Ground Connections | No. of Wires | Industry Designation | Electrical Phase | Current | Wire Connection Type | For Wire Gauge | For Cable OD | Temp. Range, °F | Features | Environmental Rating | Choose a Voltage | Each | |
2.5" | 3 | 1 | 2 | 2W3P | Single | 60A | Screw Terminals | 8-2 | 0.5"-1.45" | -40° to 165° | Cord Grip, Power-Indicating Light | NEMA 4X, NEMA 12, IP69K | 0000000 | 0000000 | |
2.5" | 4 | 1 | 3 | 3W4P | Three | 60A | Screw Terminals | 8-2 | 0.5"-1.45" | -40° to 165° | Cord Grip, Power-Indicating Light | NEMA 4X, NEMA 12, IP69K | 0000000 | 00000000 | |
2.5" | 5 | 1 | 4 | 4W5P | Three | 60A | Screw Terminals | 8-2 | 0.5"-1.45" | -40° to 165° | Cord Grip, Power-Indicating Light | NEMA 4X, NEMA 12, IP69K | 277V AC/480V AC | 0000000 | 00000000 |


2W3P
Female

2W3P
Female

3W4P
Female

AC,
4W5P Female

3W4P
Female
Face Dia. | No. of Poles | No. of Ground Connections | No. of Wires | Industry Designation | Electrical Phase | Current | Wire Connection Type | For Wire Gauge | Features | Temp. Range, °F | Environmental Rating | Choose a Voltage | Each | |
2.5" | 3 | 1 | 2 | 2W3P | Single | 60A | Screw Terminals | 8-2 | Cord Grip, Power-Indicating Light | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 0000000 | 0000000 | |
2.5" | 4 | 1 | 3 | 3W4P | Three | 60A | Screw Terminals | 8-2 | Cord Grip, Power-Indicating Light | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 0000000 | 00000000 | |
2.5" | 5 | 1 | 4 | 4W5P | Three | 60A | Screw Terminals | 8-2 | Cord Grip, Power-Indicating Light | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 277V AC/480V AC | 0000000 | 00000000 |
Safe-Break Pin-and-Sleeve Connectors
Connect and disconnect with the power on—spring-loaded contacts open like a switch when separating the connectors, preventing an electrical arc. These connectors are approved as switch-rated connectors for branch circuit and motor circuit disconnect switching. When mated, they form a NEMA 4X rated connection that resists corrosion and protects against washdowns. A ground pin is included in the number of wires.
Receptacles include a junction box with a conduit entry hub.
Finger drawplates (sold separately) create a grip around plugs and sockets or receptacles, making it easier to pull them together tightly when mating.
Caps (sold separately) protect plugs when not in use.
For technical drawings and 3-D models, click on a part number.


Face Dia. | No. of Poles | No. of Ground Connections | No. of Wires | Industry Designation | Electrical Phase | Current | Wire Connection Type | For Wire Gauge | For Cable OD | Temp. Range, °F | Environmental Rating | Choose a Voltage | Each | |
2.2" | 4 | 1 | 3 | 3W4P | Three | 60A | Screw Terminals | 12-4 | 0.2"-0.82" | -40° to 140° | IP66, IP67, IP69K, NEMA 4X | 0000000 | 0000000 |


Face Dia. | No. of Poles | No. of Ground Connections | No. of Wires | Industry Designation | Electrical Phase | Current | Wire Connection Type | For Wire Gauge | For Cable OD | Temp. Range, °F | Environmental Rating | Choose a Voltage | Each | |
2.2" | 4 | 1 | 3 | 3W4P | Three | 60A | Screw Terminals | 12-4 | 0.2"-0.82" | -40° to 140° | IP66, IP67, IP69K, NEMA 4X | 0000000 | 0000000 |


Conduit | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Face Dia. | No. of Poles | No. of Ground Connections | No. of Wires | Industry Designation | Electrical Phase | Current | Wire Connection Type | For Wire Gauge | Trade Size | Thread Type | Temp. Range, °F | Environmental Rating | Choose a Voltage | Each | |
2.2" | 4 | 1 | 3 | 3W4P | Three | 60A | Screw Terminals | 12-4 | 1 | NPT | -40° to 140° | IP66, IP67, IP69K, NEMA 4X | 0000000 | 0000000 |

For Connector Current | Includes | Each | |
60 A | Two Drawplates, Two Gaskets | 00000000 | 000000 |

For Connector Current | For Face Dia. | Manufacturer | Manufacturer Model No. | Material | Color | Environmental Rating | Each | |
60 A | 2.2" | Meltric | 61-6A426 | Neoprene Rubber | Black | IP66, IP67, IP69K, NEMA 4X | 00000000 | 000000 |

For Connector Current | Material | Each | |
60 A | Polyester Plastic | 00000000 | 000000 |

For Connector Current | Material | Each | |
30 A, 60 A | Polyester Plastic | 00000000 | 000000 |
Hazardous Location Safe-Break Pin-and-Sleeve Connectors
Use connectors where ignitable gas and dust may be present, such as in refineries and silos. They are CSA certified for Class I, Division 2, Groups A, B, C, and D; and Class II, Division 2, Groups F and G. All have a chamber that withstands the pressure of an internal ignition—isolating it from spreading to the surrounding environment. They're rated IP66 and IP67 for protection from washdowns and temporary submersion.
Finger drawplates (sold separately) create a grip around plugs and sockets or receptacles, making it easier to pull them together tightly when mating.
Caps (sold separately) protect plugs when not in use.
For technical drawings and 3-D models, click on a part number.

For Connector Current | Includes | Each | |
60 A | Two Drawplates, Two Gaskets | 00000000 | 000000 |

For Connector Current | For Face Dia. | Manufacturer | Manufacturer Model No. | Material | Color | Each | |
60 A | 3.1" | Meltric | 22-6A426 | Neoprene Rubber | Black | 0000000 | 000000 |
IEC Pin-and-Sleeve Connectors
These connectors meet international standards IEC 60309-1 and 60309-2, so they’re compatible with other IEC 60309 devices. They have a nonconductive nylon housing so they’re safer to use than components made of metal. Plugs have a notch that must line up with a keyway in sockets and receptacles when mating. All have a ground pin that is included in the number of wires.
IP67 rated connectors protect against dust and submersion.


3W4P
Male

3W4P
Male


3W4P
Female

3W4P
Female
Corrosion-Resistant Pin-and-Sleeve Connectors
When used together, connectors maintain a watertight and corrosion-resistant NEMA 4X connection. All meet UL 1686 and are fully interchangeable with other UL 1686 configured and listed devices.
3W4P (three wire four pole) connectors have a ground pin that is included in the number of poles. They are marked 3W4P.
Receptacles include a mounting box with a conduit entry hub.
For technical drawings and 3-D models, click on a part number.




Face Dia. | No. of Poles | No. of Ground Connections | No. of Wires | Industry Designation | Electrical Phase | Current | Voltage | Wire Connection Type | For Wire Gauge | For Cable OD | Temp. Range, °F | Each | ||
A | 2.3" | 3 | 0 | 3 | 3W3P | Three | 60A | 250V DC/600V AC | Screw Terminals | 6-2 | 0.65"-1.5" | -55° to 100° | 0000000 | 0000000 |
B | 2.5" | 4 | 0 | 4 | 4W4P | Three | 60A | 250V DC/600V AC | Screw Terminals | 6-2 | 0.65"-1.5" | -55° to 100° | 0000000 | 000000 |
C | 2.5" | 4 | 1 | 3 | 3W4P | Three | 60A | 250V DC/600V AC | Screw Terminals | 6-2 | 0.65"-1.5" | -55° to 100° | 0000000 | 000000 |




Face Dia. | No. of Poles | No. of Ground Connections | No. of Wires | Industry Designation | Electrical Phase | Current | Voltage | Wire Connection Type | For Wire Gauge | For Cable OD | Temp. Range, °F | Each | ||
A | 2.3" | 3 | 0 | 3 | 3W3P | Three | 60A | 250V DC/600V AC | Screw Terminals | 6-2 | 0.65"-1.5" | -55° to 100° | 0000000 | 0000000 |
B | 2.5" | 4 | 0 | 4 | 4W4P | Three | 60A | 250V DC/600V AC | Screw Terminals | 6-2 | 0.65"-1.5" | -55° to 100° | 0000000 | 000000 |
C | 2.5" | 4 | 1 | 3 | 3W4P | Three | 60A | 250V DC/600V AC | Screw Terminals | 6-2 | 0.65"-1.5" | -55° to 100° | 0000000 | 00000000 |




Conduit | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Face Dia. | No. of Poles | No. of Ground Connections | No. of Wires | Industry Designation | Electrical Phase | Current | Voltage | Wire Connection Type | For Wire Gauge | Trade Size | Thread Type | Temp. Range, °F | Each | ||
A | 2.3" | 3 | 0 | 3 | 3W3P | Three | 60A | 250V DC/600V AC | Screw Terminals | 6-2 | 1 1/2 | NPT | -55° to 100° | 0000000 | 0000000 |
B | 2.5" | 4 | 0 | 4 | 4W4P | Three | 60A | 250V DC/600V AC | Screw Terminals | 6-2 | 1 1/2 | NPT | -55° to 100° | 0000000 | 000000 |
C | 2.5" | 4 | 1 | 3 | 3W4P | Three | 60A | 250V DC/600V AC | Screw Terminals | 6-2 | 1 1/2 | NPT | -55° to 100° | 0000000 | 000000 |
Flat Pin-and-Sleeve Connectors
Reduce the likelihood of slips and falls in high-traffic areas—plugs and sockets won't roll when stepped on. Ground pins are included in the number of wires.
For technical drawings and 3-D models, click on a part number.

No. of Poles | No. of Ground Connections | No. of Wires | Current (Voltage) | Wire Connection Type | For Wire Gauge | For Cable OD | Ht. | Wd. | Temp. Range, °F | Each | |
2 | 1 | 3 | 60A (125V AC); 60A (250V AC); 60A (125V DC) | Screw Terminals | 6 | 0.1"-0.86" | 1.2" | 3.4" | -5° to 265° | 000000 | 000000 |

No. of Poles | No. of Ground Connections | No. of Wires | Current (Voltage) | Wire Connection Type | For Wire Gauge | For Cable OD | Ht. | Wd. | Temp. Range, °F | Each | |
2 | 1 | 3 | 60A (125V AC); 60A (250V AC); 60A (125V DC) | Screw Terminals | 6 | 0.1"-0.86" | 1.2" | 3.4" | -5° to 265° | 000000 | 000000 |