About Extension Cords
More
Choosing an Electrical Switch
More
IEC Connectors
Pair these connectors with standard IEC power cords to bring power into or out of your electronic devices. Often used to convey power from wall outlets, there’s no need to wire your devices to an external power source. Instead, wire these connectors into your device with the terminals on the back of each connector. Most meet U.S. or international standards for safety.
Receptacles are often installed in electrical devices. Most also include shock protection. Class I shock protection means they're insulated and have a protective ground to prevent electrical shocks. Class II shock protection means there are two levels of insulation to prevent electrical shocks. Male receptacles are commonly used to bring power into an electronic device. Some accept a fuse to prevent short circuits and circuit overloads from damaging your devices. The fuses are sold separately. Female receptacles are frequently used to bring power out of one electronic device and into another. C13 receptacles are also known as Sheet F outlets. Screw-on connectors mount to devices with any panel thickness, as long as you can drill mounting holes into the device. Snap-in connectors mount to devices with snap-in tabs—no fasteners needed—but require a specific panel thickness and a precisely cut hole for secure mounting.
Tab terminal wire connections are more secure than screw and quick-disconnect terminal connections. Quick-disconnect terminal wire connections are faster to wire than screw and tab terminal connections. The terminals slide together with the quick-disconnect terminals on your wiring and are easily disconnected by hand, but still provide a strong hold.
IP-rated connectors meet standards for protecting you from making contact with a live circuit. The larger the first digit, the smaller the object it protects against. An IP30 rating means screwdrivers and other objects larger than 2.5 mm won't get in. And an IP40 rating means wire and other objects larger than 1 mm won't get in.
Connectors with a UL 94 rating have passed one of UL's flame tests. UL 94 V-0 means they self-extinguish within 10 seconds if they catch fire and won’t spread flames from dripping. UL 94 V-2 means they self-extinguish within 30 seconds if they catch fire, but may drip flaming particles.
For technical drawings and 3-D models, click on a part number.










For Fuse | For Panel Cutout | Each | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connector Component | IEC Style | Voltage | Current (Rating) | O'all Lg., mm | O'all Dia., mm | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Environmental Rating | Shock Protection Class | Specifications Met | 1-49 | 50-249 | 250-Up | |
Quick-Disconnect Terminals | ||||||||||||||||
Receptacle | C14 | 250V AC | 10A (UL), 10A (IEC) | 20 | 5 | 1.24" | 1.08" | 0.24" | -10° to 155° | IP40 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, IEC 60320, ENEC Marked | 0000000 | 00000 | 00000 | 00000 |
Receptacle | C14 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.83" | 1.12" | 0.31" | -10° to 155° | IP40 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, IEC 60320, ENEC Marked | 0000000 | 0000 | 0000 | 0000 |
Receptacle | C16 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.1" | 0.314" | -10° to 245° | IP40 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, IEC 60320, ENEC Marked | 0000000 | 0000 | 0000 | 0000 |
Receptacle | C16A | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.787" | 1.08" | 0.314" | -10° to 310° | IP40 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, IEC 60320, ENEC Marked | 0000000 | 0000 | 0000 | 0000 |
Receptacle | C18 | 250V AC | 10A (UL), 10A (IEC) | 20 | 5 | 1.24" | 1.08" | 0.1" | -10° to 155° | IP40 | II | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, IEC 60320, ENEC Marked | 0000000 | 0000 | 0000 | 0000 |
Receptacle | C18 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.83" | 1.12" | 0.31" | -10° to 155° | IP40 | II | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, IEC 60320, ENEC Marked | 0000000 | 0000 | 0000 | 0000 |
Tab Terminals | ||||||||||||||||
Receptacle | C14 | 250V AC | 10A (UL), 10A (IEC) | 20 | 5 | 1.24" | 1.08" | 0.24" | -10° to 155° | IP40 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, IEC 60320, ENEC Marked | 0000000 | 0000 | 0000 | 0000 |
Receptacle | C16 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.1" | 0.314" | -10° to 245° | IP40 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, IEC 60320, ENEC Marked | 0000000 | 0000 | 0000 | 0000 |
Receptacle | C18 | 250V AC | 10A (UL), 10A (IEC) | 20 | 5 | 1.24" | 1.08" | 0.1" | -10° to 155° | IP40 | II | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, IEC 60320, ENEC Marked | 0000000 | 0000 | 0000 | 0000 |
Receptacle | C18 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.83" | 1.12" | 0.31" | -10° to 155° | IP40 | II | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, IEC 60320, ENEC Marked | 0000000 | 0000 | 0000 | 0000 |










For Fuse | For Panel Cutout | Each | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | O'all Lg., mm | O'all Dia., mm | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Environmental Rating | Shock Protection Class | Specifications Met | 1-49 | 50-249 | 250-Up | |
Quick-Disconnect Terminals | |||||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | __ | __ | 1.07" | 1 1/4" | 0.031"-0.079" | __ | __ | I | UL Recognized Component, CSA Certified, VDE Certified, IEC 60320 | 0000000 | 00000 | 00000 | 00000 |
C14 | 250V AC | 10A (UL), 10A (IEC) | __ | __ | 1.24" | 1.07" | 0.03"-0.08" | __ | __ | I | UL Recognized Component, CSA Certified, VDE Certified, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
C14 | 250V AC | 10A (UL), 10A (IEC) | 20 | 5 | 1.24" | 1.08" | 0.098" | -10° to 155° | IP40 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
C14 | 250V AC | 10A (UL), 10A (IEC) | 20 | 5 | 1.24" | 1.08" | 0.118" | -10° to 155° | IP40 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.098" | -10° to 155° | IP30 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.118" | -10° to 155° | IP30 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.81" | 1.06" | 0.031"-0.059" | __ | __ | I | UL Recognized Component, CSA Certified, VDE Certified, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
C16 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.059" | -10° to 245° | IP30 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
C16 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.098" | -10° to 245° | IP30 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
C16 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.118" | -10° to 245° | IP30 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
C16A | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.787" | 1.08" | 0.059" | -10° to 310° | IP30 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
C16A | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.787" | 1.08" | 0.118" | -10° to 310° | IP30 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
C18 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.06" | -10° to 155° | IP30 | II | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
Tab Terminals | |||||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 20 | 5 | 1.24" | 1.08" | 0.098" | -10° to 155° | IP40 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
C14 | 250V AC | 10A (UL), 10A (IEC) | 20 | 5 | 1.24" | 1.08" | 0.118" | -10° to 155° | IP40 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.06" | 0.031"-0.059" | __ | __ | I | UL Recognized Component, CSA Certified, VDE Certified, IEC 60320 | 0000000 | 0000 | 0000 | 000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.098" | -10° to 155° | IP30 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 000 |
C16 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.059" | -10° to 245° | IP30 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
C16 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.098" | -10° to 245° | IP30 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
C16 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.118" | -10° to 245° | IP30 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
C18 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.06" | -10° to 155° | IP30 | II | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |




For Panel Cutout | Each | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Environmental Rating | Shock Protection Class | Specifications Met | Environmental Rating | 1-49 | 50-249 | 250-Up | |
Quick-Disconnect Terminals | ||||||||||||||
C13 | 250V AC | 15A (UL), 10A (IEC) | 1" | 1.3" | 0.31" | -10° to 155° | IP30 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | IP30 | 0000000 | 00000 | 00000 | 00000 |
Tab Terminals | ||||||||||||||
C13 | 250V AC | 15A (UL), 10A (IEC) | 1" | 1.3" | 0.31" | -10° to 155° | IP30 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | IP30 | 0000000 | 0000 | 0000 | 0000 |




For Panel Cutout | Each | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Environmental Rating | Shock Protection Class | Specifications Met | 1-49 | 50-249 | 250-Up | |
Quick-Disconnect Terminals | |||||||||||||
C13 | 250V AC | 15A (UL), 10A (IEC) | 1" | 1.28" | 0.031"-0.079" | __ | __ | I | UL Recognized Component, UL 94 V-2, CSA Certified, VDE Certified, IEC 60320 | 0000000 | 00000 | 00000 | 00000 |
C13 | 250V AC | 15A (UL), 10A (IEC) | 1" | 1.3" | 0.1" | -10° to 155° | IP30 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
C13 | 250V AC | 15A (UL), 10A (IEC) | 1" | 1.3" | 0.11" | -10° to 155° | IP30 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
Tab Terminals | |||||||||||||
C13 | 250V AC | 15A (UL), 10A (IEC) | 1" | 1.28" | 0.031"-0.079" | __ | __ | I | UL Recognized Component, UL 94 V-2, CSA Certified, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
C13 | 250V AC | 15A (UL), 10A (IEC) | 1" | 1.3" | 0.1" | -10° to 155° | IP30 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
C13 | 250V AC | 15A (UL), 10A (IEC) | 1" | 1.3" | 0.11" | -10° to 155° | IP30 | I | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CSA Certified, CE Marked, ENEC Marked, IEC 60320 | 0000000 | 0000 | 0000 | 0000 |
IEC Connectors with Power Switch
Switch your device on and off without needing a separate switch. These connectors work with industry standard cords often found on power supplies, appliances, and other electronic devices. Wire these connectors using the quick-disconnect terminals. They slide together with mating terminals for a secure hold that's also easy to pull apart to make repairs. The terminals are on the back of the connector, so the wiring stays inside your device.
Class I shock protection means they have insulation and a protective ground. They meet UL 94 V-0, so they self-extinguish within 10 seconds if they catch fire and won’t spread the fire by dripping. They’re also UL and C-UL recognized components, CE and ENEC marked, and CSA certified—they meet U.S., Canadian, and European safety standards.
Drill mounting holes in your device to mount screw-on connectors to housings of any thickness. Snap-in connectors secure with tabs. They do not require fasteners, but they do need a specific panel thickness on your device housing and a precisely cut hole for secure mounting.
The power switch on connectors with an indicator light illuminates when your device is on.
Shielded connectors protect against interference from nearby equipment.
Connectors for 20 mm-long fuses have a drawer to hold a fuse (sold separately), which prevents short circuits and circuit overloads from damaging your device.
For technical drawings and 3-D models, click on a part number.

Receptacle with
Fuse Circuit Protection


Receptacle with
Fuse Circuit Protection



For Fuse | For Panel Cutout | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | No. of Circuits Controlled | Switch Starting Position | Industry Designation | O'all Dia., mm | O'all Lg., mm | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Environmental Rating | Indicator Color | Each | |
Screw On | |||||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | 5 | 20 | 1.11" | 1.85" | 0.314" | -10° to 185° | IP40 | __ | 0000000 | 000000 |
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | 5 | 20 | 1.11" | 1.85" | 0.314" | -10° to 185° | IP40 | Green, Red | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | 1 Off (Normally Open) | SPST-NO | __ | __ | 1.24" | 1.09" | 0.24" | -10° to 155° | IP40 | __ | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.24" | -10° to 155° | IP40 | __ | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.24" | -10° to 155° | IP40 | Green, Red | 00000000 | 00000 |
Snap In | |||||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | __ | 2 Off (Normally Open) | DPST-NO | 5 | 20 | 1.88" | 1.13" | 0.039", 0.059", 0.079", 0.098" | 0° to 155° | IP40 | __ | 0000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 1 | 1 Off (Normally Open) | SPST-NO | __ | __ | 1.24" | 1.09" | 0.059" | -10° to 155° | IP40 | __ | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 1 | 1 Off (Normally Open) | SPST-NO | __ | __ | 1.24" | 1.09" | 0.098" | -10° to 155° | IP40 | __ | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.059" | -10° to 155° | IP40 | __ | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.059" | -10° to 155° | IP40 | Green, Red | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.098" | -10° to 155° | IP40 | __ | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.098" | -10° to 155° | IP40 | Green, Red | 00000000 | 00000 |

Receptacle with
Fuse Circuit Protection


For Fuse | For Panel Cutout | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | No. of Circuits Controlled | Switch Starting Position | Industry Designation | O'all Dia., mm | O'all Lg., mm | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Environmental Rating | Indicator Color | Each | |
Screw On | |||||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | 5 | 20 | 1.11" | 1.85" | 0.314" | -10° to 185° | IP40 | Green, Red | 00000000 | 000000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.24" | -10° to 155° | IP40 | Green, Red | 00000000 | 00000 |
Snap In | |||||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | __ | 2 Off (Normally Open) | DPST-NO | 5 | 20 | 1.88" | 1.13" | 0.039", 0.059", 0.079", 0.098" | 0° to 155° | IP40 | __ | 0000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.059" | -10° to 155° | IP40 | Green, Red | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.098" | -10° to 155° | IP40 | Green, Red | 00000000 | 00000 |

with Green Indicator Light
and Fuse Circuit Protection


with Red Indicator Light
and Fuse Circuit Protection





For Fuse | For Panel Cutout | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | No. of Circuits Controlled | Switch Starting Position | Industry Designation | O'all Dia., mm | O'all Lg., mm | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Environmental Rating | Each | |
Green Indicator | ||||||||||||||
Screw On | ||||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | 5 | 20 | 1.11" | 1.85" | 0.314" | -10° to 185° | IP40 | 0000000 | 000000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.24" | -10° to 155° | IP40 | 00000000 | 00000 |
Snap In | ||||||||||||||
C14 | 250V AC | 15A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.059" | -10° to 155° | IP40 | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.098" | -10° to 155° | IP40 | 00000000 | 00000 |
Green Indicator, Red Indicator | ||||||||||||||
Screw On | ||||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | 5 | 20 | 1.11" | 1.85" | 0.314" | -10° to 185° | IP40 | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.24" | -10° to 155° | IP40 | 00000000 | 00000 |
Snap In | ||||||||||||||
C14 | 250V AC | 15A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.059" | -10° to 155° | IP40 | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.098" | -10° to 155° | IP40 | 00000000 | 00000 |
Red Indicator | ||||||||||||||
Screw On | ||||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | 5 | 20 | 1.11" | 1.85" | 0.314" | -10° to 185° | IP40 | 0000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.24" | -10° to 155° | IP40 | 00000000 | 00000 |
Snap In | ||||||||||||||
C14 | 250V AC | 15A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.059" | -10° to 155° | IP40 | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.098" | -10° to 155° | IP40 | 00000000 | 00000 |
For Fuse | ||||
---|---|---|---|---|
For No. of Fuses | O'all Dia., mm | O'all Lg., mm | Each | |
2 | 5 | 20 | 00000000 | 00000 |
Harsh Environment IEC Connectors with Power Switch



Rated IP67, these connectors create a dust- and watertight seal where they fit into the housing of power supplies, appliances, and other electronic devices. Instead of hardwiring your devices, these connectors let you plug in a standard IEC power cord and turn the power on and off with a built-in switch. Wire these connectors using the quick-disconnect terminals; they slide together with matching terminals on your wiring for a secure hold that's also easy to pull apart to make repairs. The terminals are on the back of the connector, so the wiring stays inside your device.
To protect your devices, these connectors have a thermal circuit breaker that uses the excess heat when there’s overcurrent to trip the breaker and cut power. If there’s a short circuit, the breakers can safely stop up to a 2,000-Amp breakthrough current. These connectors also have Class I shock protection, so they’re insulated and have a protective ground.
These connectors meet UL 94 V-0, which means they self-extinguish within 10 seconds if they catch fire, and won’t spread the fire by dripping. They’re also UL and C-UL recognized components, and CE and ENEC marked, so they meet stringent safety standards.
For technical drawings and 3-D models, click on a part number.
UL Rating | IEC Rating | For Panel Cutout | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Current, A | Voltage | Frequency, Hz | Voltage | Frequency, Hz | No. of Circuits Controlled | Switch Starting Position | Industry Designation | Ht. | Wd. | Temp. Range, °F | Environmental Rating | Each | |
Male Receptacles | ||||||||||||||
Screw On | ||||||||||||||
C14 | 10 | 250V AC | 60 | 250V AC | 50 | 2 | 2 Off (Normally Open) | DPST-NO | 2.32" | 1.35" | -10° to 140° | IP67 | 00000000 | 000000 |
Multi-Outlet IEC Connectors






Distribute power from one electronic device to several others with these connectors. By housing multiple outlets in a single unit, they save space and time spent on installation. They’re compatible with IEC power cords, which are the industry standard for power connections. The outlets are C13 receptacles, also known as Sheet F outlets.
Wire these connectors into your device with the terminals on the back of each outlet. They mount to your device with snap-in tabs—no fasteners needed—but require a specific panel thickness and a precisely cut hole for secure mounting.
All meet international standards for safety. They are rated for Class I Shock Protection, meaning they have insulation and a protective ground.
Solder connections are more secure than quick-disconnect terminals. These connectors meet UL 94 V-2, which means they’ll self-extinguish within 30 seconds if they catch fire, but may drip flaming particles.
Quick-disconnect terminals are faster to wire than solder connections. The terminals slide together with the quick-disconnect terminals on your wiring and are easily disconnected by hand, but still provide a strong hold. Rated IP30, these connectors prevent objects larger than 2.5 mm, such as screwdrivers, from making contact with a live circuit and shocking you. They also meet UL 94 V-0, so they’ll self-extinguish within 10 seconds if they catch fire and won’t spread flames from dripping.
For technical drawings and 3-D models, click on a part number.
UL Rating | TUV Rating | For Panel | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current, A | Frequency, Hz | Current, A | Frequency, Hz | Cutout Ht. | Cutout Wd. | Thick. | Temp. Range, °F | Color | Each | |
Grounded | ||||||||||||
C13 | 250V AC | 15 | 60 | 10 | 50 | 1.9" | 1.3" | 0.05"-0.07" | 15° to 155° | Black | 0000000 | 00000 |
UL Rating | TUV Rating | For Panel | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current, A | Frequency, Hz | Current, A | Frequency, Hz | Cutout Ht. | Cutout Wd. | Thick. | Temp. Range, °F | Color | Each | |
Grounded | ||||||||||||
C13 | 250V AC | 15 | 60 | 10 | 50 | 2.8" | 1.3" | 0.05"-0.07" | 15° to 155° | Black | 0000000 | 00000 |
UL Rating | TUV Rating | For Panel | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current, A | Frequency, Hz | Current, A | Frequency, Hz | Cutout Ht. | Cutout Wd. | Thick. | Temp. Range, °F | Color | Each | |
Grounded | ||||||||||||
C13 | 250V AC | 15 | 60 | 10 | 50 | 3.8" | 1.3" | 0.05"-0.07" | 15° to 155° | Black | 0000000 | 00000 |
UL Rating | IEC Rating | For Panel | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current, A | Frequency, Hz | Current, A | Frequency, Hz | Cutout Ht. | Cutout Wd. | Thick. | Temp. Range, °F | Color | Each | |
Grounded | ||||||||||||
C13 | 250V AC | 15 | 60 | 10 | 50 | 3.8" | 1.3" | 0.06" | 15° to 155° | Black | 0000000 | 000000 |
Combination Inlet/Outlet IEC Connectors



Send power to your device using the inlet, then route power to another device through the outlet—all with standard IEC power cords. Compared to using separate receptacles, these combination connectors are quicker to install and have a more streamlined appearance. Snap the connector into your panel—tabs on the side hold them in place without needing fasteners. Then solder your power supply to the wire terminals for a secure, permanent bond. C13 receptacles are also known as Sheet F outlets.
Rated IP30, these connectors prevent objects greater than 2.5mm wide, such as screwdrivers, from touching internal components and accidentally shocking you. With Class I shock protection, they’re insulated and have a protective ground.
These connectors meet UL 94 V-0, which means they self-extinguish within 10 seconds if they catch fire, and won’t spread the fire by dripping. They’re also UL recognized, CE marked, CSA certified, and ENEC marked, so you know they meet stringent safety standards.
For technical drawings and 3-D models, click on a part number.
UL Rating | IEC Rating | For Panel | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current, A | Frequency, Hz | Voltage | Current, A | Frequency, Hz | Cutout Ht. | Cutout Wd. | Thick. | Temp. Range, °F | Color | Each | |
Grounded | |||||||||||||
C13 (Female), C14 (Male) | 125V AC | 15 | 60 | 250V AC | 10 | 50 | 2" | 1.3" | 0.03"-0.08" | -10° to 155° | Black | 0000000 | 00000 |
EMI Filtering IEC Connectors with Power Switch
With a built-in switch, these connectors run power to appliances, power supplies, and other electronic devices while also filtering damaging EMI (electromagnetic interference). Instead of hardwiring your devices, add these connectors and plug in a standard IEC power cord. Wire these connectors using the quick-disconnect terminals; they slide together with matching terminals on your wiring for a secure hold that's also easy to pull apart to make repairs. The terminals are on the back of the connector, so the wiring stays inside your device. For the best EMI filtering performance, choose a connector with a current rating at or slightly above your device's current requirements.
Rated IP40, these connectors prevent objects larger than a 1 mm-wd. wire from touching internal components and accidentally shocking you. With Class I shock protection, they’re insulated and have a protective ground. Some have a fuse drawer to hold a fuse, which prevents short circuits and circuit overloads from damaging your device. The fuses are sold separately.
These connectors meet UL 94 V-0, which means they self-extinguish within 10 seconds if they catch fire, and won’t spread the fire by dripping. They’re also UL and C-UL recognized components, ENEC marked, and CSA certified, so they meet stringent safety standards.
Screw-on connectors mount to housings of any thickness, as long as you can drill mounting holes into them. Snap-in connectors have tabs on the side to mount to housings without using fasteners. But, they require a specific panel thickness and precisely cut hole for secure mounting.
Shielded connectors protect against interference from nearby equipment.
For technical drawings and 3-D models, click on a part number.


Receptacle with
Fuse Circuit Protection




For Fuse | For Panel Cutout | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | No. of Circuits Controlled | Switch Starting Position | Industry Designation | For No. of Fuses | O'all Dia., mm | O'all Lg., mm | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Environmental Rating | Each | |
Screw On | |||||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 1 | 1 Off (Normally Open) | SPST-NO | __ | __ | __ | 1.31" | 1.15" | 0.314" | -10° to 185° | IP40 | 00000000 | 000000 |
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | __ | 1.31" | 1.15" | 0.314" | -10° to 185° | IP40 | 00000000 | 00000 |
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | 2 | 5 | 20 | 1.17" | 1.94" | 0.314" | -10° to 185° | IP40 | 0000000 | 00000 |
Snap In | |||||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 1 | 1 Off (Normally Open) | SPST-NO | __ | __ | __ | 1.3" | 1.16" | 0.039"-0.118" | -10° to 185° | IP40 | 00000000 | 00000 |
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | __ | 1.3" | 1.16" | 0.039"-0.118" | -10° to 185° | IP40 | 00000000 | 00000 |
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | 2 | 5 | 20 | 1.16" | 1.94" | 0.039"-0.118" | -10° to 185° | IP40 | 0000000 | 00000 |
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | 2 | 5 | 20 | 1.88" | 1.13" | 0.039", 0.059", 0.079", 0.098" | -10° to 185° | IP40 | 0000000 | 00000 |
For Fuse | ||||
---|---|---|---|---|
For No. of Fuses | O'all Dia, mm | O'all Lg., mm | Each | |
2 | 5 | 20 | 00000000 | 00000 |
EMI Filtering IEC Connectors
Bring power into electronic devices while protecting them from harmful electromagnetic interference (EMI). All of these connectors are compatible with standard IEC power cords. Often used to convey power from wall outlets, there’s no need to wire your devices to an external power source. Instead, wire these connectors into your device with the terminals on the back of each connector. When selecting a connector, make sure the current is at or slightly above the requirements of your device for the best EMI filtering performance.
All of these connectors meet U.S. and international standards for safety. They also meet UL 94 V-0, which means they self-extinguish within 10 seconds if they catch fire, and won’t spread the fire by dripping. Rated IP40, these connectors prevent objects larger than 1 mm, such as wire, from making contact with a live circuit and shocking you. They also include shock protection. Class I shock protection means they're insulated and have a protective ground to prevent electrical shocks.
Screw-on connectors mount to devices with any panel thickness, as long as you can drill mounting holes into the device. Snap-in connectors mount to devices with snap-in tabs—no fasteners needed—but require a specific panel thickness and a precisely cut hole for secure mounting.
Quick-disconnect terminal wire connections are faster to wire than tab terminal connections. The terminals slide together with the quick-disconnect terminals on your wiring and are easily disconnected by hand, but still provide a strong hold.
For technical drawings and 3-D models, click on a part number.



For Panel Cutout | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Environmental Rating | Shock Protection Class | Specifications Met | Each | |
Quick-Disconnect Terminals | |||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 0.85" | 1.14" | 0.315" | -10° to 185° | IP40 | I | UL Recognized Component, C-UL Recognized Component, ENEC Marked, CE Marked, UL 94 V-0 | 00000000 | 000000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 0.85" | 1.14" | 0.315" | -10° to 185° | IP40 | I | UL Recognized Component, C-UL Recognized Component, ENEC Marked, CE Marked, UL 94 V-0 | 00000000 | 00000 |



For Panel Cutout | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Environmental Rating | Shock Protection Class | Specifications Met | Each | |
Quick-Disconnect Terminals | |||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 0.85" | 1.16" | 0.032"-0.079" | -10° to 185° | IP40 | I | UL Recognized Component, C-UL Recognized Component, ENEC Marked, CE Marked, UL 94 V-0 | 00000000 | 000000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 0.85" | 1.16" | 0.032"-0.079" | -10° to 185° | IP40 | I | UL Recognized Component, C-UL Recognized Component, ENEC Marked, CE Marked, UL 94 V-0 | 00000000 | 00000 |
Vehicle DC Connectors
Power ancillary devices, such as chargers for electronics, from a vehicle. When used together, the plug and socket create a moisture-resistant seal. Used separately, they are compatible with devices that have standard 12-volt plugs and sockets. All have a moisture-proof, corrosion-resistant housing.
For technical drawings and 3-D models, click on a part number.

Voltage | Current | For No. of Wires | Wire Connection Type | For Wire Gauge | For Cable OD | OD | Lg. | Color | Features | Temp. Range, °F | Each | |
12V DC | 10A | 2 | Screw Terminals | 16 | 0.2"-0.31" | 0.9" | 3.7" | Black | Power-Indicating Light | -5° to 265° | 000000 | 000000 |
Mini Connectors
Often used to send power and signal to automated systems, motors, and pumps, these mini connectors carry higher currents than M5, M8, and M12 connectors. A threaded housing securely mates with other mini connectors and won’t come loose from shaking or vibration. They have a standard pole layout and housing thread size to reduce the chance you’ll mis-mate connectors.
Receptacles thread into panels and walls, so they work well in stationary or permanent installations. Receptacles with epoxy-coated zinc housing resist corrosion and weld-slag for use in harsh environments.
When mated, these connectors meet IP or NEMA ratings. IP67 rated connectors protect against dust and temporary submersion.
Caps protect connectors and maintain their IP and NEMA ratings when not in use.
For technical drawings and 3-D models, click on a part number.


Housing Thread | Mounting | 1 ft. Wire Lead Lg. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Face Dia. | Voltage | Current | Wire Lead Gauge | Color | Housing Material | Size | Type | Pipe Size | Thread Type | For Panel Cutout Dia. | Max. Temp., °F | Environmental Rating | Each | |
4 | 0.55" | 600V AC/600V DC | 10A | 16 | Black | Epoxy-Coated Zinc | 7/8"-16 | UNS | 1/2 | NPT | 0.88" | 220° | IP67 | 00000000 | 000000 |


Housing Thread | Mounting | 1 ft. Wire Lead Lg. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Face Dia. | Voltage | Current | Wire Lead Gauge | Color | Housing Material | Size | Type | Pipe Size | Thread Type | For Panel Cutout Dia. | Max. Temp., °F | Environmental Rating | Each | |
4 | 0.55" | 600V AC/600V DC | 10A | 16 | Black | Epoxy-Coated Zinc | 7/8"-16 | UNS | 1/2 | NPT | 0.88" | 220° | IP67 | 00000000 | 000000 |

Thread | ||||||
---|---|---|---|---|---|---|
For Face Dia. | Size | Type | Material | Temp. Range, °F | Each | |
Internal Thread | ||||||
0.55" | 7/8"-16 | UNS | Anodized Aluminum | 0° to 220° | 00000000 | 000000 |
Harsh Environment Mini Connectors
Send higher current than M5, M8, and M12 connectors near tough industrial jobs, such as welding and metal machining. These mini connectors have a stainless steel housing or TPE cable that resists abrasion and cracking from exposure to water, chemicals, oil, coolant, or weld slag. They’re commonly used to send power and signal to automated systems, motors, and pumps. A threaded housing securely mates with other mini connectors to keep out contaminants and won’t come loose from shaking or vibration. They have a standard pole layout and housing thread size to reduce the chance you’ll mis-mate connectors.
When mated, these connectors meet IP67 and NEMA 6P for protection against dust, submersion, washdowns, and weather.
Receptacles thread into panels and walls, so they work well in stationary or permanent installations.
Caps protect connectors and maintain their IP and NEMA ratings when not in use.
For technical drawings and 3-D models, click on a part number.


Housing Thread | 1 ft. Wire Lead Lg. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Face Dia. | Voltage | Current | Wire Lead Gauge | Housing Material | Size | Type | Type | For Panel Cutout Dia. | Max. Temp., °F | Environmental Rating | Mounting Pipe Size | Each | |
4 | 0.55" | 600V AC/600V DC | 10A | 16 | Stainless Steel | 7/8"-16 | UNS | NPT | 0.88" | 190° | IP67, NEMA 6P | 1/2 | 0000000 | 000000 |


Housing Thread | 1 ft. Wire Lead Lg. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Face Dia. | Voltage | Current | Wire Lead Gauge | Housing Material | Size | Type | Type | For Panel Cutout Dia. | Max. Temp., °F | Environmental Rating | Mounting Pipe Size | Each | |
4 | 0.55" | 600V AC/600V DC | 10A | 16 | Stainless Steel | 7/8"-16 | UNS | NPT | 0.88" | 190° | IP67, NEMA 6P | 1/2 | 0000000 | 000000 |

Thread | ||||||
---|---|---|---|---|---|---|
For Face Dia. | Size | Type | Material | Temp. Range, °F | Each | |
Internal Thread | ||||||
0.55" | 7/8"-16 | UNS | Stainless Steel | 0° to 220° | 00000000 | 000000 |
Servomotor M23 Connectors


with
Mounting Holes
Use these connectors with servomotor, servocontrollers, and servodrives in automated equipment and assembly lines. Rated NEMA 4X, IP67, and IP69K, they resist corrosion and protect against high-pressure, high-temperature washdowns. When mating connectors, the gender, housing thread location, and pole layout must be opposite. Poles are numbered on the face of the connector.
Signal connectors communicate between servocontrollers, servodrives, and servomotors.
For technical drawings and 3-D models, click on a part number.

Clockwise
(12 Pole Shown)

Connectors | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Low-Current | High-Current | Replacement Housings | Replacement Inserts | ||||||||||||
No. of Poles | Pole Layout | No. of Poles | Current | For Wire Gauge | No. of Poles | Current | For Wire Gauge | Voltage | For Panel Cutout Dia. | Each | Each | Each | |||
Receptacle—External Thread | |||||||||||||||
19 | Clockwise | 16 | 8A | 28-17 | 3 | 10A | 28-17 | 100V AC/100V DC | 1" | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 000000 |
Receptacle with 4 Mounting Holes—External Thread | |||||||||||||||
19 | Clockwise | 16 | 8A | 28-17 | 3 | 10A | 28-17 | 100V AC/100V DC | 0.79" | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
Protect M23 connectors when not in use.
Thread | ||||
---|---|---|---|---|
Size | Pitch, mm | Material | Each | |
Internal Thread | ||||
M23 | 1 | Nickel-Plated Brass | 0000000 | 00000 |
CB Radio Connectors

Housing Thread | Mounting Thread | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | Pin Dia. | Wire Connection Type | For Wire Gauge | Housing Material | Size | Pitch, mm | OD | Lg. | For Panel Cutout Dia. | Size | Type | Temp. Range, °F | Each | |
Screw Together with External Thread | ||||||||||||||||
3 | 120V AC | 10A | 0.093" | Solder | 16 | Nickel-Plated Zinc | M16 | 1 | 0.71" | 0.78" | 0.64" | 5/8"-27 | UNS | -20° to 85° | 0000000 | 000000 |
Electronic Equipment Outlet Strips



Power computers, lab equipment, and office machines that have IEC connections. These outlet strips have a circuit breaker to prevent damage from current overload and short circuits. Connect an IEC C13 power cord (not included) to the plug on the end to power these outlet strips.
For technical drawings and 3-D models, click on a part number.
Mounting Holes | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outlets | Outlet Ctr.-to-Ctr. | Current, A | Voltage | Features | Material | Protection Type | Mounting Fasteners Included | No. of | Dia | Specifications Met | Color | Each | |
IEC C13 Socket with IEC C14 Plug | |||||||||||||
4 | 7/8" | 10 | 250V AC | IEC C14 Inlet Connector, Power Switch | ABS Plastic | Circuit Breaker | No | 1 | 0.24" | UL Listed | Black | 0000000 | 000000 |
Vehicle Extension Cords

Plug these cords into a vehicle outlet to power a device from the vehicle's battery. The connectors resists moisture and corrosion. An attached cap seals out water when the extension cord is not in use.
Lg., ft. | Retracted Lg. | Wire Gauge | Current, A | Voltage | Power-Indicating Light | Color | Each | |
Vehicle Plug × Vehicle Socket | ||||||||
---|---|---|---|---|---|---|---|---|
6 | 14" | 18 | 10 | 12V DC | Without Power-Indicating Light | Black | 000000 | 000000 |