About Industry Designation for Cable Insulation
More
About NEMA Straight-Blade Plugs, Connectors, and Receptacles
More
About NEMA Plugs, Sockets, and Receptacles
More
About Extension Cords
More
Outlet Strips
Provide power to multiple devices with these outlet strips. A circuit breaker prevents damage from current overload and short circuits.
Telephone connections connect to a land line. The face of 360° outlets rotate a full circle.
Surge suppression outlet strips protect against damage from voltage spikes. Surge rating indicates how much energy the outlet strip can absorb before it needs to be replaced; the higher the number, the better the protection.
Fasten mounting clips to a surface, and snap the channel on the back of outlet strips into the clips.





No. of Sockets | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Total No. of Outlets | NEMA 5-15 | NEMA 5-20 | Outlet Ctr.-to-Ctr. | Cord Lg., ft. | Current, A | Voltage | Features | Material | Protection Type | Includes | Specifications Met | Each | |
NEMA 5-15 and NEMA 5-20 Socket with NEMA 5-20 Plug | |||||||||||||
24 | 22 | 2 | 2 3/4" | 15 | 20 | 125V AC | Lighted Power Switch | Aluminum | Circuit Breaker | Mounting Clips | UL Listed, C-UL Listed | 00000000 | 0000000 |
NEMA 5-15 and NEMA 5-20 Socket with NEMA L5-20 Plug | |||||||||||||
24 | 22 | 2 | 2 3/4" | 15 | 20 | 125V AC | Lighted Power Switch | Aluminum | Circuit Breaker | Mounting Clips | UL Listed, C-UL Listed | 00000000 | 000000 |



Telephone | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Total No. of Outlets | Outlet Ctr.-to-Ctr. (No.) | Connection Type | No. of Jacks | Cord Lg., ft. | Current, A | Voltage | Features | Material | Surge Rating | Protection Type | Specifications Met | Each | |
NEMA 5-15 Socket with NEMA 5-15 Plug | |||||||||||||
6 | 1 1/2" (4) 1 3/4" (2) | RJ11 | 2 | 15 | 15 | 125V AC | Lighted Power Switch | Steel | 1340J | Circuit Breaker, Surge Suppression | UL Listed | 0000000 | 000000 |
GFCI Outlet Strips




Keep personnel safe from electric shock with ground fault protection.
90° elbow plugs fit flush against a wall outlet, so they fit behind machinery or in areas where space is tight.
Outlet strips with a circuit breaker prevent damage from current overload and short circuits.
Flip-down covers protect outlets from dust when not in use.
Outlet strips with a manual reset prevent equipment from starting up unexpectedly after ground is established.
Total No. of Outlets | Outlet Ctr.-to-Ctr. (No.) | Cord Lg., ft. | Current, A | Voltage | Features | Material | Protection Type | Reset Type | Specifications Met | Color | Each | |
NEMA 5-15 Socket with NEMA 5-15 Plug | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
2 | 1 1/2" (2) | 6 | 15 | 125V AC | Test Button, Flip-Down Cover | Polycarbonate Plastic | GFCI | Manual | __ | Yellow | 0000000 | 000000 |
NEMA 5-15 Socket with 90° Elbow NEMA 5-15 Plug | ||||||||||||
6 | 1 1/4" (4) 1 3/4" (2) | 9 | 15 | 125V AC | Test Button, Lighted Power Switch | Steel | Circuit Breaker, GFCI | Manual | UL Listed | Yellow | 0000000 | 00000 |
Sure-Grip Outlet Strips
Also known as hospital-grade outlet strips, these outlets have an extra-tight fit to prevent plugs from detaching. They are marked with a green dot. A circuit breaker prevents damage from current overload and short circuits.
Outlets strips with coiled cord can stretch to reach a power source, then return to a tight coil for tangle-free storage.



Total No. of Outlets | Outlet Ctr.-to-Ctr. (No.) | Cord Lg., ft. | Retracted Lg., ft. | Current, A | Voltage | Features | Material | Specifications Met | Each | |
NEMA 5-15 Socket with NEMA 5-15 Plug | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
3 | 1 1/4" (2) 1 7/8" (1) | 9 | 3 | 13 | 125V AC | Coiled Cord, Green Dot | PVC Plastic | UL Listed | 00000000 | 000000 |
3 | 1 1/4" (2) 1 7/8" (1) | 11 | 3 1/2 | 13 | 125V AC | Coiled Cord, Green Dot | PVC Plastic | UL Listed | 00000000 | 00000 |
Interference-Limiting Outlet Strips
Filters between the outlets on these strips protect computers and other sensitive equipment from external signals that interfere with the equipment’s performance. A circuit breaker prevents damage from current overload and short circuits. Surge suppression protects devices from voltage spikes. The surge rating indicates how much energy the outlet strip can absorb before it needs to be replaced; the higher the number, the better the protection.



No. of Outlets | Outlet Ctr.-to-Ctr. | Cord Lg., ft. | Current, A | Voltage | Features | Surge Rating | Material | Protection Type | Circuit Breaker Trip Current, A | Specifications Met | Color | Each | |
NEMA 5-15 Socket with 90° Elbow NEMA 5-15 Plug | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2 | 1 1/2" | 6 | 15 | 125V AC | Lighted Power Switch | 1450J | Steel | Circuit Breaker, Surge Suppression | 12 | UL Listed | Gray | 0000000 | 000000 |
Covered-Cord Outlet Strips



A combination of an outlet box, cord, and duct, these outlet strips minimize tripping hazards and protect the cord from damage. The cord extends two feet beyond the end of the duct. They have a 90° elbow plug that fits flush against a wall outlet, so they fit behind machinery or in areas where space is tight. Use tape with adhesive on both sides to secure duct.
No. of Outlets | Outlet Ctr.-to-Ctr. | Cord Lg., ft. | Duct Lg., ft. | Current, A | Voltage | Material | Specifications Met | Choose a Color | Each | |
NEMA 5-15 Socket with 90° Elbow NEMA 5-15 Plug | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
2 | 1 9/16" | 6 | 4 | 13 | 125V AC | PVC Plastic | UL Listed | 00000000 | 000000 | |
2 | 1 9/16" | 7 | 5 | 13 | 125V AC | PVC Plastic | UL Listed | 00000000 | 00000 | |
2 | 1 9/16" | 8 | 6 | 13 | 125V AC | PVC Plastic | UL Listed | 00000000 | 00000 | |
2 | 1 9/16" | 12 | 10 | 13 | 125V AC | PVC Plastic | UL Listed | 00000000 | 00000 |
Outlet Splitters





Convert one outlet into multiple outlets.
Style D has a durable metal housing. It includes mounting hardware to attach to a receptacle.
Styles E-J have USB ports to charge mobile devices.
Splitters with surge suppression protect devices from voltage spikes. Surge rating indicates how much energy the outlet strip can absorb before it needs to be replaced. The higher the number, the better the protection.




Current, A | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Style | No. of Outlets | USB Connection Type (No. of Ports) | NEMA 5-15 Socket | USB Port | Voltage | Material | Specifications Met | Color | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | ||||||||||
E | 2 | A (1) C (1) | 15 | 3.1 3.1 | 125V AC | Plastic | ETL Listed, C-ETL Listed | White | 000000 | 000000 |
F | 2 | A (2) | 15 | 2.4 | 125V AC | Plastic | ETL Listed, C-ETL Listed | White | 000000 | 00000 |
Temperature-Controlled Outlet Splitters



Automatically power heating and cooling devices on and off when temperatures rise or drop. With two outlets each, you can run multiple devices. Plug them into a standard wall outlet.
Heating outlet splitters turn the power on when your space drops below a set temperature. They cut the power once temperatures warm up. Splitters that turn on at 20° F are often used to switch on engine and battery heaters when working in cold temperatures. Splitters that turn on at 35° F work best with heaters to warm a space and prevent freezing.
Cooling outlet splitters turn the power on when your space rises above a set temperature. They’re often used to turn on fans or other devices for cooling, ventilation, and air circulation. These outlet splitters cut the power once temperatures cool off.
For technical drawings and 3-D models, click on a part number.
On/Off Temp. | No. of Outlets | Current, A | Voltage | Material | Specifications Met | Color | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | ||||||||
---|---|---|---|---|---|---|---|---|
Heating/Power | ||||||||
20° F On, 30° F Off | 2 | 15 | 120V AC | Plastic | UL Listed, C-UL Listed | White | 0000000 | 000000 |
35° F On, 45° F Off | 2 | 15 | 120V AC | Plastic | UL Listed, C-UL Listed | White | 0000000 | 00000 |
Cooling/Power | ||||||||
78° F On, 70° F Off | 2 | 15 | 120V AC | Plastic | UL Listed, C-UL Listed | Red | 0000000 | 00000 |
Bench-Top Outlet Strips

Mount these outlet strips to a desktop or workbench with the mounting hardware, or set them on a surface. The outlets have internal shutters to prevent the insertion of foreign objects. These outlet strips have a 90° elbow plug that fits flush against a wall outlet, so they fit behind machinery or in areas where space is tight. The plug also has an outlet on the back to connect equipment. Use the USB ports to charge mobile devices.





No. of Outlets | Outlet Ctr.-to-Ctr. | USB Connection Type (No. of Ports) | Cord Lg., ft. | Current, A | Voltage | Features | Material | Specifications Met | Choose a Color | Each | |
NEMA 5-15 Socket with 90° Elbow NEMA 5-15 Plug | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
2 | 1 1/8" | A (2) | 6 | 15 | 125V AC | Internal Shutters, Three-Prong Outlet | Polycarbonate Plastic | ETL Listed, C-ETL Listed | White | 0000000 | 000000 |
2 | 1 1/8" | A (1) C (1) | 6 | 15 | 120V AC | Internal Shutters, Three-Prong Outlet | Polycarbonate Plastic | ETL Listed, C-ETL Listed | 0000000 | 00000 |
Rack-Mount Outlet Strips

Mount these strips into standard 19” wide electronics racks, enclosures, and cabinets. All have a circuit breaker to prevent damage from current overload and short circuits.
Front outlets power external components. Rear outlets power components inside the cabinet.



Mounting Holes | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Total No. of Outlets | Outlet Ctr.-to-Ctr. | Cord Lg., ft. | Current, A | Voltage | Features | Material | Protection Type | Mounting Fasteners Included | No. of | Dia. | Specifications Met | Each | |
NEMA 5-15 Socket with NEMA 5-15 Plug | |||||||||||||
Outlet Strips with Front and Rear Outlets | |||||||||||||
6 | 1 1/2" | 6 | 15 | 125V AC | Lighted Power Switch, Power-Indicating Light | Steel | Circuit Breaker | No | 4 | 0.25" | C-UL Recognized Component, UL Recognized Component | 00000000 | 0000000 |
6 | 1 1/2" | 15 | 15 | 125V AC | Lighted Power Switch, Power-Indicating Light | Steel | Circuit Breaker | No | 4 | 0.25" | C-UL Recognized Component, UL Recognized Component | 00000000 | 000000 |
Magnet-Mount Outlet Strips



No need for mounting hardware—these outlet strips have magnets on the back to stick to steel walls, cabinets, and other magnetic surfaces. Mount them off the ground to reduce tripping hazards in your facility. The magnets are rated for 25 lbs. of force, so they won’t accidentally get knocked down or pulled off. A circuit breaker prevents damage from current overload and short circuits.



Total No. of Outlets | Outlet Center-to-Center (No.) | Cord Lg., ft. | Current, A | Voltage | Features | Material | Protection Type | Specifications Met | Each | |
NEMA 5-15 Socket with NEMA 5-15 Plug | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
6 | 1 1/2" (4) 1 3/4" (2) | 6 | 15 | 125V AC | Lighted Power Switch | Steel | Circuit Breaker | UL Listed, C-UL Listed | 0000000 | 000000 |
Extension Cord Splitters
Power multiple devices from the same outlet with these splitters.
Two-outlet and three-outlet splitters plug into an outlet or extension cord.Splitters with a 90° elbow plug sit flush against wall outlets to fit in tight spaces.
Use SJT and SPT-2 splitters in dry or damp locations. STW splitters have a water-resistant insulation.Splitters with a quick-release tab let you unplug devices by pressing down with your thumb.
For technical drawings and 3-D models, click on a part number.











Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg., ft. | Wire Ga. | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Features | Specifications Met | Color | Each | |
NEMA 1-15 Plug × NEMA 1-15 Socket | ||||||||||||
1 | 18, 16 | 10 | 125V AC | Without Power-Indicating Light | 0.28" | PVC Plastic | SPT-2 | Quick-Release Tab | UL Listed, C-UL Listed | White | 00000000 | 000000 |
NEMA 5-15 Plug × NEMA 5-15 Socket | ||||||||||||
1 | 16 | 13 | 125V AC | Without Power-Indicating Light | 0.33" | PVC Plastic | SJT | __ | UL Listed, C-UL Listed | Black | 00000000 | 00000 |
1 | 14 | 15 | 125V AC | Without Power-Indicating Light | 0.37" | PVC Plastic | SJT | __ | UL Listed, C-UL Listed | Black | 00000000 | 00000 |
2 | 12 | 15 | 125V AC | Without Power-Indicating Light | 0.56" | Rubber | STW | __ | UL Listed | Yellow | 0000000 | 00000 |
90° Elbow NEMA 5-15 Plug × NEMA 5-15 Socket | ||||||||||||
1 | 14 | 15 | 125V AC | Without Power-Indicating Light | 0.37" | PVC Plastic | SJT | __ | UL Listed, C-UL Listed | Black | 00000000 | 00000 |
NEMA L5-30 Plug × NEMA L5-30 Socket | ||||||||||||
3 | 10 | 30 | 125V AC | Without Power-Indicating Light | 0.67" | PVC Plastic | STW | __ | UL Listed, C-UL Listed | Yellow | 00000000 | 00000 |
NEMA L6-20 Plug × NEMA L6-20 Socket | ||||||||||||
3 | 10 | 20 | 250V AC | Without Power-Indicating Light | 0.57" | PVC Plastic | SJT | __ | UL Listed, C-UL Listed | Black | 00000000 | 000000 |
Sure-Grip Locking Electronic Equipment Cord Splitters



Create secure, vibration-resistant connections on both ends—these cord splitters have a hospital-grade plug and locking sockets. To keep them from detaching, the plug forms an extra-tight connection with outlets. Once they’re locked onto male receptacles, the sockets stay put until you unlock them. The SJTW cord has a water-resistant outer insulation. Use with computers, lab equipment, and office machines that have IEC connections.
For technical drawings and 3-D models, click on a part number.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Features | Temperature Range | Specifications Met | Color | Each | |
NEMA 5-15 Plug × IEC C13 Socket | ||||||||||||
16 | 13 | 125V AC | 10 | 0.33" | PVC Plastic | SJTW | Green Dot | 0° F to 220° F | UL Listed, C-UL Listed | Gray | 0000000 | 000000 |
T-Slotted Framing Outlet Strips



Add electrical outlets to workstations with these outlet strips that mount on T-slotted rails. They have surge suppression to protect sensitive electronics from voltage spikes.
For technical drawings and 3-D models, click on a part number.
For Rail Ht. | No. of Sockets | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Single | Double | Triple | Quad | Total No. of Outlets | NEMA 5-15 | NEMA 5-20 | Outlet Ctr.-to-Ctr. | Cord Lg., ft. | Lg. | Current, A | Voltage | Protection Type | Specifications Met | Mounting Fasteners Included | Each | |
NEMA 5-15 and NEMA 5-20 Socket with NEMA 5-20 Plug | ||||||||||||||||
1 1/2" 1" 25mm 30mm 40mm 45mm | 2" 3" 50mm 60mm 80mm 90mm | 3" 4 1/2" 75mm 120mm | 4" 6" 100mm 160mm | 12 | 10 | 2 | 2 1/2" | 15 | 36" | 20 | 120V AC | Surge Suppression | UL Listed | Yes | 00000000 | 0000000 |