We will reply to your message within an hour.
More
Use a single valve to create motion and control the speed of that motion.
Air pressure must be supplied to both inlets before the output port will open, allowing air flow to downstream components. Also known as "and" valves.
Also known as blocking valves, these valves allow airflow while an air signal is applied to the air pilot. When the signal stops, the valve closes, trapping air in the system.
Mount these valves directly to cylinder ports, eliminating additional tubing between the cylinder and valve for better control than inline valves. They control the speed of air-powered equipment by adjusting the volume of airflow.
Designed to be mounted inline, these valves can be installed in an easy-to-reach location along your line. They control the speed of air-powered equipment by adjusting the volume of airflow.
A swiveling outlet port on these valves makes connections from any direction. They control the speed of air-powered equipment by adjusting the volume of airflow.
Designed to be mounted inline, these valves can be placed in an easy-to-reach location along your line to control the speed of air-powered equipment by adjusting the volume of airflow. A numeric indicator provides a relative measure of airflow, similar to the volume dial on a speaker, so it's easy to set the same flow rate with each use.
A numeric indicator provides a relative measure of airflow, similar to the volume dial on a speaker, so it's easy to set the same flow rate with each use. Mount them directly to cylinder ports, eliminating additional tubing between the cylinder and valve for better control than inline valves. They control the speed of air-powered equipment by adjusting the volume of airflow.
A fine-adjustment dial allows tighter control of airflow and cylinder speed than other flow control valves. They control the speed of air-powered equipment by adjusting the volume of airflow entering or exiting.
Prevent accidental airflow changes with these valves, which require an adjustment tool to alter their flow rate. They control the speed of air-powered equipment by adjusting the volume of airflow.
Mount these valves directly to cylinder ports, eliminating additional tubing between the cylinder and valve for better control than inline valves. Made of plastic and stainless steel parts, they have excellent corrosion resistance. They control the speed of air-powered equipment by adjusting the volume of airflow.
Designed to be mounted inline, these valves can be placed in easy-to-reach locations. Made of plastic and stainless steel parts, they have excellent corrosion resistance. They control the speed of air-powered equipment by adjusting the volume of airflow.
These valves handle pressure up to 265 psi. They control the speed of air-powered equipment by adjusting the volume of airflow entering or exiting.
Protect air-powered equipment in emergency shut-off situations—when system pressure drops, these valves automatically close to stop cylinder motion, even at mid-stroke. They control the speed of air-powered equipment by adjusting the volume of airflow entering or exiting.
Prevent damage to your equipment by limiting startup airflow and then gradually raising the airflow rate to operating levels.
Control the flow of exhaust air while also regulating the exhaust air speed. These valves dump exhaust air to the atmosphere without routing it back through a directional control valve. The 90° elbow shape allows you to install them in tight spaces. Also known as quick exhaust valves.
Install these valves in the exhaust ports of air directional control valves to control exhaust air speed without needing access to your cylinder.
These valves open to allow flow in one direction and close when flow stops or reverses direction.
Prevent air from escaping an air storage tank when the air compressor is not running. These valves open to allow flow into the tank and close when flow stops or reverses direction.
Designed for use in dust-collection systems, these diaphragm valves periodically burst air to knock debris from filters.
Convert a continuous stream of air into a series of quick pulses, reducing air consumption by up to 50% and improving performance in air-blowing applications such as cleaning and drying.
For use with threaded pipe, these valves are available with NPT, NPTF, BSPP, BSPT, and UNI/UNF (JIC) connections.
With a shorter end-to-end length than other check valves, these fit in tight spaces.
At 1 1/2" long or less, these valves fit in confined spaces.
Plastic provides a lightweight alternative to metal.
To achieve the maximum possible flow, internal components are designed to reduce flow resistance.
With few moving parts to wear out, these valves withstand frequent opening and closing, pulsating flow, and rapid flow reversal.
Rated for up to twice the pressure of standard check valves, these can withstand pressures up to 3,000 psi.
The heat-resistant rubber seal withstands temperatures up to 500° F.
Barbs grip onto tubing, providing a secure hold.
For more durability than plastic barbed check valves, these have a stainless steel body.
Insert tubing into the fitting—no heat, solder, or flux required.
Sandwich these valves between two ANSI flanges for backflow prevention at a fraction of the weight of flanged check valves and a reduced pipeline footprint.
Less than half the end-to-end length of standard flange-mount check valves, these can be installed in pipelines with limited clearance.
Two sleeves give the fittings extra gripping power. They bite into tubing as you tighten the nut to form a strong seal. All are compatible with Swagelok®, Let-Lok, and Parker A-Lok fittings.
With internal components that resist wear from frequent operation, these valves can cycle as often as once per second.
Also known as luer lock couplings, quick-turn fittings consist of a plug and a socket that connect with a half turn, so you can easily connect and disconnect your line.
Visually inspect flow and debris accumulation through the transparent valve body.
Weld these valves to unthreaded pipe for a smooth, flush connection that provides maximum flow.
Bolt to ANSI flanges.
To reduce installation time and allow for maintenance without detaching pipe connections, these valves insert into a union fitting.
Insert tubing into the fittings—no heat, solder, or flux required.
To reduce installation time and allow for maintenance without detaching pipe connections, these valves have union fittings.
These valves open to allow flow in one direction and close when flow stops or reverses.
Valves have NPT connections for use with threaded pipe.