About Wire and Cable
More
About Industry Designation for Cable Insulation
More
Miniature Cable
- Use For: Automation, Interference Shielding, Continuous Motion
- Continuous Flex
- Temperature Range: -40° to 220° F
- Insulation: PVC Plastic
Often used in computers, small electronics, and electronic prototyping, this cable is very flexible with small gauge wire to handle tight curves in narrow spaces. It withstands continuous motion, so it’s also commonly used around heavy vibration and in automated tasks, including robotics. A braid shield blocks interference from nearby equipment.
Wire Gauge | Number of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | 10 ft. | 25 ft. | |
Shielded Stranded Wire | |||||||||
---|---|---|---|---|---|---|---|---|---|
200V AC | |||||||||
36 | 2 | 36/2 | 0.6 A @ 86° F | 0.06" | Black | Black, White | 0000000 | ||
36 | 3 | 36/3 | 0.6 A @ 86° F | 0.06" | Black | Black, Red, White | 0000000 | ||
36 | 4 | 36/4 | 0.5 A @ 86° F | 0.07" | Black | Black, Green, Red, White | 0000000 | ||
32 | 5 | 32/5 | 0.9 A @ 86° F | 0.08" | Black | Black, Green, Red, White, Yellow | 0000000 | ||
30 | 2 | 30/2 | 1.7 A @ 86° F | 0.07" | Black | Black, White | 0000000 | ||
30 | 3 | 30/3 | 1.7 A @ 86° F | 0.08" | Black | Black, Red, White | 0000000 | ||
30 | 4 | 30/4 | 1.4 A @ 86° F | 0.08" | Black | Black, Green, Red, White | 0000000 | ||
30 | 8 | 30/8 | 1.2 A @ 86° F | 0.1" | Black | Black, Blue, Brown, Green, Orange, Red, White, Yellow | 0000000 | ||
28 | 2 | 28/2 | 2.2 A @ 86° F | 0.09" | Black | Black, White | 0000000 | ||
28 | 3 | 28/3 | 2.2 A @ 86° F | 0.1" | Black | Black, Red, White | 0000000 | ||
28 | 4 | 28/4 | 1.8 A @ 86° F | 0.1" | Black | Black, Green, Red, White | 0000000 | ||
28 | 5 | 28/5 | 1.8 A @ 86° F | 0.11" | Black | Black, Green, Red, White, Yellow | 0000000 | ||
26 | 2 | 26/2 | 3 A @ 86° F | 0.11" | Black | Black, White | 0000000 | ||
26 | 3 | 26/3 | 3 A @ 86° F | 0.11" | Black | Black, Red, White | 0000000 | ||
26 | 4 | 26/4 | 2.4 A @ 86° F | 0.12" | Black | Black, Green, Red, White | 0000000 | ||
26 | 5 | 26/5 | 2.4 A @ 86° F | 0.13" | Black | Black, Green, Red, White, Yellow | 0000000 | ||
26 | 6 | 26/6 | 2.4 A @ 86° F | 0.15" | Black | Black, Blue, Green, Red, White, Yellow | 0000000 |
Thin-Insulation Control Cable
- Use For:
Unshielded: Automation
Double Shielded: Automation, Interference Shielding - Flexible
- Temperature Range: -40° to 220° F
- Insulation: Modified Polyphenylene Ether (mPPE) Plastic
Nearly two-thirds the diameter of standard control cable, this cable fits in tight spaces. The modified polyphenylene ether (mPPE) insulation is less than half the weight of the PVC insulation found on standard control cable, yet is more abrasion and cut resistant. Use it to send signal and data to operate, measure, or regulate automated equipment that requires cable to periodically flex and bend. It’s often used with conveyors, CNC machines, and to connect equipment to a control panel. Cable is flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
Double shielded cable has a layer of braid and foil shielding that provides excellent protection against signal interference from nearby equipment and devices.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | |||||||||||
600V AC | |||||||||||
20 | 3 | 20/3 | 6 A @ 86° F | 0.19" | Gray | Black, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
20 | 4 | 20/4 | 4 A @ 86° F | 0.21" | Gray | Black, Green, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 0000 | 0000 | |
20 | 7 | 20/7 | 4 A @ 86° F | 0.24" | Gray | Black, Blue, Brown, Green, Orange, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
20 | 9 | 20/9 | 4 A @ 86° F | 0.3" | Gray | Black, Blue, Brown, Green, Orange, Purple, Red, White, Yellow | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
20 | 12 | 20/12 | 3 A @ 86° F | 0.3" | Gray | Beige, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
18 | 2 | 18/2 | 8 A @ 86° F | 0.21" | Gray | Black, Red | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 0000 | 0000 | |
18 | 3 | 18/3 | 8 A @ 86° F | 0.22" | Gray | Black, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 0000 | 0000 | |
18 | 4 | 18/4 | 6 A @ 86° F | 0.24" | Gray | Black, Green, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 0000 | 0000 | |
18 | 5 | 18/5 | 6 A @ 86° F | 0.26" | Gray | Black, Green, Orange, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 0000 | |
18 | 7 | 18/7 | 6 A @ 86° F | 0.28" | Gray | Black, Blue, Brown, Green, Orange, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
18 | 12 | 18/12 | 4 A @ 86° F | 0.35" | Gray | Beige, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
16 | 3 | 16/3 | 12 A @ 86° F | 0.25" | Gray | Black, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 0000 | |
16 | 4 | 16/4 | 9 A @ 86° F | 0.27" | Gray | Black, Green, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
14 | 3 | 14/3 | 24 A @ 86° F | 0.28" | Gray | Black, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
14 | 4 | 14/4 | 19 A @ 86° F | 0.31" | Gray | Black, Green, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
Double-Shielded Stranded Wire | |||||||||||
600V AC | |||||||||||
20 | 3 | 20/3 | 6 A @ 86° F | 0.23" | Gray | Black, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 0000 | 0000 | |
20 | 4 | 20/4 | 4 A @ 86° F | 0.24" | Gray | Black, Green, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
20 | 7 | 20/7 | 4 A @ 86° F | 0.27" | Gray | Black, Blue, Brown, Green, Orange, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
20 | 9 | 20/9 | 4 A @ 86° F | 0.33" | Gray | Black, Blue, Brown, Green, Orange, Purple, Red, White, Yellow | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
20 | 12 | 20/12 | 3 A @ 86° F | 0.34" | Gray | Beige, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
18 | 2 | 18/2 | 8 A @ 86° F | 0.24" | Gray | Black, Red | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 0000 | 0000 | |
18 | 3 | 18/3 | 8 A @ 86° F | 0.25" | Gray | Black, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
18 | 4 | 18/4 | 6 A @ 86° F | 0.27" | Gray | Black, Green, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
18 | 5 | 18/5 | 6 A @ 86° F | 0.29" | Gray | Black, Green, Orange, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
18 | 7 | 18/7 | 6 A @ 86° F | 0.31" | Gray | Black, Blue, Brown, Green, Orange, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
18 | 12 | 18/12 | 4 A @ 86° F | 0.39" | Gray | Beige, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
16 | 3 | 16/3 | 12 A @ 86° F | 0.28" | Gray | Black, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
16 | 4 | 16/4 | 9 A @ 86° F | 0.3" | Gray | Black, Green, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
14 | 3 | 14/3 | 24 A @ 86° F | 0.32" | Gray | Black, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
14 | 4 | 14/4 | 19 A @ 86° F | 0.34" | Gray | Black, Green, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 |
Thin-Insulation Continuous-Flex Cable
- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -40° to 175° F
- Insulation:
Outer: Polyurethane Rubber
Inner: Modified Polyphenylene Ether (mPPE) Plastic
For use in tight spaces, this cable has up to a 40% smaller OD than standard continuous-flex cable so it fits in tight spaces. The inner insulation is modified polyphenylene ether (mPPE), making the cable nearly half the weight of standard continuous-flex cable. Often used in automated applications such as robotics and cable carriers, it withstands continuous motion without degrading data or signal transmission.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | |
Stranded Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | |||||||||||||
20 | 2 | 20/2 | 5.6 A @ 86° F | 0.18" | 1" | Gray | Black, Green/Yellow | UL Recognized Component, CSA Certified | 0000000 | ||||
20 | 3 | 20/3 | 5.6 A @ 86° F | 0.19" | 1.1" | Gray | Black, Green/Yellow | UL Recognized Component, CSA Certified | 0000000 | ||||
18 | 2 | 18/2 | 7.9 A @ 86° F | 0.19" | 1.2" | Gray | Black, Green/Yellow | UL Recognized Component, CSA Certified | 0000000 | ||||
18 | 3 | 18/3 | 7.9 A @ 86° F | 0.2" | 1.3" | Gray | Black, Green/Yellow | UL Recognized Component, CSA Certified | 0000000 |
Thin-Insulation Wire
- Use for buildings, motors, panel and equipment (hook-up)
- Flexible
- Temperature Range: -40° to 220° F
- Insulation: Modified Polyphenylene Ether (mPPE) Plastic
Nearly half the diameter and up to 40% lighter than standard wire of the same gauge and voltage, this wire fits in tight spaces. Also known as hook-up wire, it’s good for wiring electrical panels and plant floor equipment, or can be used as an alternative to building wire. It’s flame rated VW-1 to meet requirements for preventing the spread of flames, based on a timed test with vertically suspended material.
For technical drawings and 3-D models, click on a part number.
Per Ft. | |||||||||
---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Strand Count | Current | OD | Specifications Met | Choose an Outer Insulation Color | Length, ft. | 1-499 | 500-Up | |
Stranded Wire | |||||||||
600V AC | |||||||||
28 | 7/36 | 1 A @ 86° F | 0.03" | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | ||
26 | 7/34 | 1 A @ 86° F | 0.04" | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000 | 000 | ||
24 | 7/32 | 2 A @ 86° F | 0.04" | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000 | 000 | ||
22 | 7/30 | 3 A @ 86° F | 0.05" | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000 | 000 | ||
20 | 10/30 | 6 A @ 86° F | 0.06" | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000 | 000 | ||
18 | 16/30 | 8 A @ 86° F | 0.07" | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000 | 000 | ||
16 | 26/30 | 12 A @ 86° F | 0.08" | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000 | 000 | ||
14 | 41/30 | 24 A @ 86° F | 0.1" | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 0000 | 000 | ||
12 | 65/30 | 30 A @ 86° F | 0.12" | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 0000 | 0000 | ||
10 | 105/30 | 43 A @ 86° F | 0.14" | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 0000 | 0000 |
High-Temperature Thin-Insulation Wire
- Use for ovens, furnaces, panel and equipment (hook-up),
- Flexible
- Temperature Range: -235° to 570° F
- Insulation: PFA Plastic
With a slim PFA plastic insulation, this wire has the same heat resistance as standard high-temperature wire but its diameter is one-third the size for use in tight spaces. It withstands water, sunlight, and chemicals, making it good for use in oil and gas applications. It’s also known as hook-up wire.
For technical drawings and 3-D models, click on a part number.
Per Ft. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Strand Count | Current | OD | Specifications Met | Wire Material | Choose an Outer Insulation Color | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | ||||||||||
600V AC | ||||||||||
28 | 7/36 | 1.4 A @ 86° F | 0.03" | UL Recognized Component | Nickel-Plated Copper | 0000000 | 00000 | 00000 | ||
26 | 19/38 | 1.8 A @ 86° F | 0.03" | UL Recognized Component | Nickel-Plated Copper | 0000000 | 0000 | 0000 | ||
24 | 19/36 | 3.5 A @ 86° F | 0.04" | UL Recognized Component | Nickel-Plated Copper | 0000000 | 0000 | 0000 | ||
22 | 19/34 | 5.3 A @ 86° F | 0.04" | UL Recognized Component | Nickel-Plated Copper | 00000000 | 0000 | 0000 | ||
20 | 19/32 | 8.8 A @ 86° F | 0.05" | UL Recognized Component | Nickel-Plated Copper | 00000000 | 0000 | 0000 | ||
18 | 19/30 | 12.4 A @ 86° F | 0.06" | UL Recognized Component | Nickel-Plated Copper | 00000000 | 0000 | 0000 | ||
16 | 19/29 | 17.7 A @ 86° F | 0.07" | UL Recognized Component | Nickel-Plated Copper | 00000000 | 0000 | 0000 |
Mini Cords
With a higher maximum current than nano M8 and micro M12 cords, these mini cords are often used with automated systems, motors, and pumps. A threaded housing securely mates with other mini connections and won’t shake loose from vibration. They have a standard pole layout and housing thread size to reduce the chance you’ll mis-mate connectors. These cords are unshielded, so they’re best for use where signal interference is not a concern.
When mated, these cords meet IP ratings for protection from dust and temporary submersion.
Thread adapters connect plugs and sockets that both have internal threads.
Caps protect connectors and maintain their IP ratings when not in use.
For technical drawings and 3-D models, click on a part number.
Cord | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | Face Dia. | Lg., ft. | Current, A | Voltage | Housing Thread Size | Wire Gauge | OD | Insulation Material | Temp. Range, °F | Shielding | Specifications Met | Color | Each | |
Plug (External Thread) × Socket (Internal Thread) | ||||||||||||||
3 | 0.875" | 1/2 | 12 | 600V AC/600V DC | 7/8"-16 | 16 | 0.39" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 000000 |
3 | 0.875" | 1 1/2 | 12 | 600V AC/600V DC | 7/8"-16 | 16 | 0.39" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
3 | 0.875" | 3 | 12 | 600V AC/600V DC | 7/8"-16 | 16 | 0.39" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
3 | 0.875" | 6 1/2 | 12 | 600V AC/600V DC | 7/8"-16 | 16 | 0.39" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
4 | 0.875" | 1/2 | 10 | 600V AC/600V DC | 7/8"-16 | 16 | 0.42" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
4 | 0.875" | 1 1/2 | 10 | 600V AC/600V DC | 7/8"-16 | 16 | 0.42" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
4 | 0.875" | 3 | 10 | 600V AC/600V DC | 7/8"-16 | 16 | 0.42" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
4 | 0.875" | 6 1/2 | 10 | 600V AC/600V DC | 7/8"-16 | 16 | 0.42" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
4 | 0.875" | 9 1/2 | 10 | 600V AC/600V DC | 7/8"-16 | 16 | 0.42" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
5 | 0.875" | 1/2 | 9 | 600V AC/600V DC | 7/8"-16 | 16 | 0.5" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
5 | 0.875" | 1 1/2 | 9 | 600V AC/600V DC | 7/8"-16 | 16 | 0.5" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
5 | 0.875" | 3 | 9 | 600V AC/600V DC | 7/8"-16 | 16 | 0.5" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
5 | 0.875" | 6 1/2 | 9 | 600V AC/600V DC | 7/8"-16 | 16 | 0.5" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
5 | 0.875" | 9 1/2 | 9 | 600V AC/600V DC | 7/8"-16 | 16 | 0.5" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 000000 |
Plug (External Thread) × 90° Elbow Socket (Internal Thread) | ||||||||||||||
3 | 0.875" | 1/2 | 12 | 600V AC/600V DC | 7/8"-16 | 16 | 0.39" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
3 | 0.875" | 1 1/2 | 12 | 600V AC/600V DC | 7/8"-16 | 16 | 0.39" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
3 | 0.875" | 3 | 12 | 600V AC/600V DC | 7/8"-16 | 16 | 0.39" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
3 | 0.875" | 6 1/2 | 12 | 600V AC/600V DC | 7/8"-16 | 16 | 0.39" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
3 | 0.875" | 9 1/2 | 12 | 600V AC/600V DC | 7/8"-16 | 16 | 0.39" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
3 | 0.875" | 16 | 12 | 600V AC/600V DC | 7/8"-16 | 16 | 0.39" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 000000 |
3 | 0.875" | 32 1/2 | 12 | 600V AC/600V DC | 7/8"-16 | 16 | 0.39" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 000000 |
4 | 0.875" | 1/2 | 10 | 600V AC/600V DC | 7/8"-16 | 16 | 0.42" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
4 | 0.875" | 1 1/2 | 10 | 600V AC/600V DC | 7/8"-16 | 16 | 0.42" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
4 | 0.875" | 3 | 10 | 600V AC/600V DC | 7/8"-16 | 16 | 0.42" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
4 | 0.875" | 6 1/2 | 10 | 600V AC/600V DC | 7/8"-16 | 16 | 0.42" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
4 | 0.875" | 9 1/2 | 10 | 600V AC/600V DC | 7/8"-16 | 16 | 0.42" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
4 | 0.875" | 16 | 10 | 600V AC/600V DC | 7/8"-16 | 16 | 0.42" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 000000 |
4 | 0.875" | 32 1/2 | 10 | 600V AC/600V DC | 7/8"-16 | 16 | 0.42" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 000000 |
5 | 0.875" | 1/2 | 9 | 600V AC/600V DC | 7/8"-16 | 16 | 0.5" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
5 | 0.875" | 1 1/2 | 9 | 600V AC/600V DC | 7/8"-16 | 16 | 0.5" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
5 | 0.875" | 3 | 9 | 600V AC/600V DC | 7/8"-16 | 16 | 0.5" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
5 | 0.875" | 6 1/2 | 9 | 600V AC/600V DC | 7/8"-16 | 16 | 0.5" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
5 | 0.875" | 9 1/2 | 9 | 600V AC/600V DC | 7/8"-16 | 16 | 0.5" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 000000 |
5 | 0.875" | 16 | 9 | 600V AC/600V DC | 7/8"-16 | 16 | 0.5" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 000000 |
5 | 0.875" | 32 1/2 | 9 | 600V AC/600V DC | 7/8"-16 | 16 | 0.5" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 000000 |
Plug (Internal Thread) × Socket (Internal Thread) | ||||||||||||||
2 | 0.55" | 6 | 13 | 600V AC/600V DC | 7/8"-16 | 16 | 0.41" | PVC Plastic | 0° to 220° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 00000000 | 00000 |
3 | 0.55" | 6 | 13 | 600V AC/600V DC | 7/8"-16 | 16 | 0.41" | PVC Plastic | 0° to 220° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 00000000 | 00000 |
4 | 0.55" | 6 | 10 | 600V AC/600V DC | 7/8"-16 | 16 | 0.42" | PVC Plastic | 0° to 220° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 00000000 | 00000 |
5 | 0.55" | 6 | 8 | 600V AC/600V DC | 7/8"-16 | 16 | 0.5" | PVC Plastic | 0° to 220° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 00000000 | 00000 |
6 | 0.55" | 6 | 8 | 600V AC/600V DC | 7/8"-16 | 16 | 0.54" | PVC Plastic | 0° to 220° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 00000000 | 00000 |
7 | 0.7" | 6 | 8 | 600V AC/600V DC | 1"-16 | 16 | 0.62" | PVC Plastic | 0° to 220° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 00000000 | 000000 |
8 | 0.7" | 6 | 7 | 600V AC/600V DC | 1"-16 | 16 | 0.61" | PVC Plastic | 0° to 220° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 00000000 | 000000 |
12 | 0.8" | 6 | 5 | 600V AC/600V DC | 1 1/8"-16 | 16 | 0.71" | PVC Plastic | 0° to 220° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 00000000 | 000000 |
M22 Power Cords
Similar to branches extending from a tree, these cords disperse power from a main power line to run a chain of devices. Power high-amperage fans, pumps, and other machines in motor controls, conveyors, and sorting and packaging systems. All quickly connect and disconnect for easy installation and maintenance.
These cords are UL and C-UL listed, so they meet American and Canadian safety standards. They comply with TC-ER requirements, meaning they withstand being hit and crushed when exposed. An STOOW rating means their inner and outer insulation resist oil and water. IP and NEMA rated when connected, these cords resist corrosion and seal out dust and water from weather and washdowns. They can even be under water for brief periods of time.
Lengthen your power line and reach more devices in your system by adding M22 connectors or M35 cords and connectors. Reducing tees join equipment with M22 connections to equipment with M35 connections.
Add a cap to protect these cords from dust when they’re not in use.
Optional locking clips stop your cord from coming loose when used with equipment that carries high amperage.
For technical drawings and 3-D models, click on a part number.
Housing Thread | Cord | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | Face Dia. | Lg., ft. | Current, A | Voltage | Size | Type | Wire Gauge | OD | Insulation Material | Industry Designation | Temp. Range, °F | Environmental Rating | Specifications Met | Color | Each | |
Plug (External Thread) × Socket (Internal Thread) | ||||||||||||||||
4 | 0.59" | 3 | 15 | 600V AC/600V DC | 7/8"-16 | UNS | 14 | 0.57" | PVC Plastic | STOOW, TC-ER | -40° to 190° | NEMA 6P, IP67 | UL Listed, C-UL Listed, UL 2237 | Black | 0000000 | 000000 |
4 | 0.59" | 6 1/2 | 15 | 600V AC/600V DC | 7/8"-16 | UNS | 14 | 0.57" | PVC Plastic | STOOW, TC-ER | -40° to 190° | NEMA 6P, IP67 | UL Listed, C-UL Listed, UL 2237 | Black | 0000000 | 00000 |
4 | 0.59" | 16 | 15 | 600V AC/600V DC | 7/8"-16 | UNS | 14 | 0.57" | PVC Plastic | STOOW, TC-ER | -40° to 190° | NEMA 6P, IP67 | UL Listed, C-UL Listed, UL 2237 | Black | 0000000 | 00000 |
4 | 0.59" | 32 1/2 | 15 | 600V AC/600V DC | 7/8"-16 | UNS | 14 | 0.57" | PVC Plastic | STOOW, TC-ER | -40° to 190° | NEMA 6P, IP67 | UL Listed, C-UL Listed, UL 2237 | Black | 0000000 | 000000 |
4 | 0.59" | 49 | 15 | 600V AC/600V DC | 7/8"-16 | UNS | 14 | 0.57" | PVC Plastic | STOOW, TC-ER | -40° to 190° | NEMA 6P, IP67 | UL Listed, C-UL Listed, UL 2237 | Black | 0000000 | 000000 |
Face Dia. | Housing Thread Size | ||||||||
---|---|---|---|---|---|---|---|---|---|
(A) | (B) | (C) | (A) | (B) | (C) | Housing Material | Color | Each | |
Plug (External Thread) × Socket (Internal Thread) × Socket (Internal Thread) | |||||||||
0.87" | 0.59" | 0.87" | 1 3/8"-16 UNS | 7/8"-16 UNS | 1 3/8"-16 UNS | PVC Plastic | Black | 0000000 | 000000 |
Material | Color | Each | |
PVC Plastic | Black | 0000000 | 00000 |
M29 Power Cords
Often used in automation systems such as conveyors and sorters, these cords have plug and socket ends, so they quickly connect and disconnect for maintenance and do not need to be hardwired. Because these cords carry higher currents than micro and mini cords, they can power equipment such as motors, fans, pumps, and automated machine tools. They are shielded to block out interference from nearby equipment. These cords meet UL 2237 and UL 2238, so they can be used in motor branch circuits of industrial machinery. They also meet TC-ER crush and impact requirements for exposed runs in cable carriers. IP rated, they protect against dust, washdowns, and temporary submersion.
Connect these cords to control cabinets and equipment with M29 power receptacles (sold separately).
For technical drawings and 3-D models, click on a part number.
Housing Thread | Cord | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | Face Dia. | Lg., ft. | Current, A | Voltage | Size | Type | Wire Gauge | OD | Insulation Material | Industry Designation | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
Shielded Plug (External Thread) × Shielded Socket (Internal Thread) | |||||||||||||||
4 | 1" | 3 | 25 | 600V AC/600V DC | 1 1/8"-16 | UNS | 12 | 0.65" | PVC Plastic | TC-ER | -10° to 190° | IP67, IP68 | UL Listed, C-UL Listed, UL 2237, UL 2238 | 0000000 | 0000000 |
4 | 1" | 6 1/2 | 25 | 600V AC/600V DC | 1 1/8"-16 | UNS | 12 | 0.65" | PVC Plastic | TC-ER | -10° to 190° | IP67, IP68 | UL Listed, C-UL Listed, UL 2237, UL 2238 | 0000000 | 000000 |
4 | 1" | 16 | 25 | 600V AC/600V DC | 1 1/8"-16 | UNS | 12 | 0.65" | PVC Plastic | TC-ER | -10° to 190° | IP67, IP68 | UL Listed, C-UL Listed, UL 2237, UL 2238 | 0000000 | 000000 |
4 | 1" | 32 1/2 | 25 | 600V AC/600V DC | 1 1/8"-16 | UNS | 12 | 0.65" | PVC Plastic | TC-ER | -10° to 190° | IP67, IP68 | UL Listed, C-UL Listed, UL 2237, UL 2238 | 0000000 | 000000 |
4 | 1" | 49 | 25 | 600V AC/600V DC | 1 1/8"-16 | UNS | 12 | 0.65" | PVC Plastic | TC-ER | -10° to 190° | IP67, IP68 | UL Listed, C-UL Listed, UL 2237, UL 2238 | 0000000 | 000000 |
M29 Power Receptacles
Mount these receptacles to control cabinets and equipment in order to quickly connect and disconnect M29 power cords. Because they carry higher currents than micro and mini receptacles, they often power motors, fans, pumps, and machine tools in automated systems. They meet UL 2237 and UL 2238, so they can be used in motor branch circuits of industrial machinery. IP rated, they protect against dust, washdowns, and temporary submersion.
For technical drawings and 3-D models, click on a part number.
Housing | Wire Lead | Mounting | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | Face Dia. | Current, A | Voltage | Thread Size | Thread Type | Material | Gauge | Lg., ft. | Pipe Size | Thread Type | For Panel Cutout Dia. | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
Male Panel-Mount Receptacle with Wire Leads (External Thread) | ||||||||||||||||
4 | 1" | 25 | 600V AC/600V DC | 1 1/8"-16 | UNS | PVC Plastic | 12 | 3 | 3/4 | NPT | 1.12" | -40° to 190° | IP67, IP68 | UL Listed, C-UL Listed, UL 2237, UL 2238 | 0000000 | 000000 |
Female Panel-Mount Receptacle with Wire Leads (Internal Thread) | ||||||||||||||||
4 | 1" | 25 | 600V AC/600V DC | 1 1/8"-16 | UNS | PVC Plastic | 12 | 3 | 1/2 | NPT | 0.87" | -40° to 190° | IP67, IP68 | UL Listed, C-UL Listed, UL 2237, UL 2238 | 0000000 | 00000 |