How to Prime Your Pump
More
How to Determine Feet of Head
More
About Process Pumps
More
About Drum Pumps
More
Inline Water-Powered Metering Pumps for Chemicals
Inject chemicals into your water supply without using electricity—these pumps install directly in your pipeline and activate when water flows into the pump head. They provide consistent metering regardless of pressure and flow changes and have an adjustment dial for altering dosing concentration. Pumps are often used with bleach, cleaning solutions, and water-treatment chemicals. All are self-priming and create suction to draw liquid upward. Do not use with solids.
Intake | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Max. Pressure, psi | Max. Viscosity, cP | Concentration Ratio | Max. Temp., °F | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Dia. | Ht. | Includes | Each | |
0.05-14 | 85 | 200 | 1:500 to 1:50 | 100° | 3/4 | NPT | Male | 3/4 | NPT | Male | 6 5/16" | 19" | 6-ft. PVC Plastic Intake Tube | 0000000 | 0000000 |
0.05-14 | 85 | 200 | 1:3,000 to 1:333 | 100° | 3/4 | NPT | Male | 3/4 | NPT | Male | 6 5/16" | 21" | 6-ft. PVC Plastic Intake Tube | 0000000 | 00000000 |
0.05-14 | 85 | 1,700 | 1:100 to 1:10 | 100° | 3/4 | NPT | Male | 3/4 | NPT | Male | 6 5/16" | 19" | 6-ft. PVC Plastic Intake Tube | 0000000 | 00000000 |
0.05-14 | 85 | 1,700 | 1:200 to 1:20 | 100° | 3/4 | NPT | Male | 3/4 | NPT | Male | 6 5/16" | 19" | 6-ft. PVC Plastic Intake Tube | 0000000 | 00000000 |
Battery-Operated Drum Pumps with Nozzle for Fuel
Operating on a 12-volt battery, these pumps transfer and drain fuel such as gasoline, diesel fuel, and kerosene. Lock the nozzle with a padlock (not included).
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Pumps with metering nozzle record total volume up to 99,999.9 gallons.
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | ID | Lg., ft. | Nozzle Type | Each | |
12V DC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
15 | 12 | 30 | -15° | 150° | 1/4 hp | 20 | 8 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1" | 20"-34 3/4" | 3/4" | 12 | Metering, Manual Shut-Off | 0000000 | 0000000 |
Electric Drum Pumps with Nozzle for Fuel
Pump fuel in hazardous environments with flammable gases. Pumps are UL listed for Class I, Divisions 1 and 2, Group D.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Style B pumps have a metering nozzle that registers total volume up to 99,999.9 gallons. Lock with a padlock (not included). A bypass valve prevents pressure buildup when the nozzle is closed.
Anti-siphon kit prevents reverse flow with a vacuum breaker and includes all hose, fittings, and seals required for installation. Pedestal kit converts your pump from a drum mount to a pedestal mount.
Temp. Range, °F | Intake | Discharge | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max.Lift, ft. | For Drum Opening Size | Gender | Pipe Size | Thread Type | Hose ID | Hose Lg., ft. | Hose OD | Nozzle Type | Max. Shackle Dia. | Electrical Connection Type | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
20 | 22 | 10 | -40° | 150 | 1/3 hp | 5.5 | 10 | 2 NPT | Female | 1 1/4 | NPT | 3/4" | 12 | 1 1/8" | Lockable, Manual Shut-Off, Metering | 3/8" | Hardwire | 0000000 | 000000000 |
Calibration Columns
Calibrate the flow rate of metering pumps. A graduated scale with zero at the top lets you easily see how much fluid is lost over the course of a one-minute test. This will tell you your pump’s flow rate. Periodic testing helps alert you to issues in your system, such as worn or dirty valves. Checking the flow rate after performing maintenance ensures your pump is working properly.
Install the column between your reservoir and pump. They require shutoff access to your reservoir and an on/off valve (not included) at the point where they connect to your system. To start the test, open the on/off valve as the system is running to fill the column with fluid up to the zero mark. Shut off the valve and wait one minute before observing the liquid level in the column. After you've taken the reading, close the on/off valve to the column and reopen access to the reservoir.
Borosilicate glass calibration columns and their fittings stand up to sulfuric acid, hydrochloric acid, and other corrosive chemicals.
Volume | Graduations | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | Ht. | Flow Rate Range, gph | gal. | ml | gph | ml/min | Temp. Range, °F | O-Ring Material | Mounting Orientation | For Use With | Each | |
Borosilicate Glass Body with PTFE Plastic Fittings | ||||||||||||
Gallons per Hour, Milliliters per Minute | ||||||||||||
1/2 NPT Female | 13" | 0 to 1.5 | 1.5 | 100 | 0.02 | 1 | 40° to 150° | Fluoroelastomer Rubber | Vertical | Water, Gasoline, Diesel Fuel, Kerosene, Ammonium Hydroxide, Bleach, Chlorine, Citric Acid, Deionized Water, Ethylene Glycol, Fuel Oil, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Methyl Chloride, Motor Oil, Nitric Acid, Paint, Phosphoric Acid, Salt Water, Soap Solutions, Sodium Hydroxide, Sulfuric Acid | 00000000 | 0000000 |
1/2 NPT Female | 16 1/2" | 0 to 4 | 4 | 250 | 0.05 | 2 | 40° to 150° | Fluoroelastomer Rubber | Vertical | Water, Gasoline, Diesel Fuel, Kerosene, Ammonium Hydroxide, Bleach, Chlorine, Citric Acid, Deionized Water, Ethylene Glycol, Fuel Oil, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Methyl Chloride, Motor Oil, Nitric Acid, Paint, Phosphoric Acid, Salt Water, Soap Solutions, Sodium Hydroxide, Sulfuric Acid | 00000000 | 000000 |
3/4 NPT Female | 18" | 0 to 8 | 8 | 500 | 0.05 | 5 | 40° to 150° | Fluoroelastomer Rubber | Vertical | Water, Gasoline, Diesel Fuel, Kerosene, Ammonium Hydroxide, Bleach, Chlorine, Citric Acid, Deionized Water, Ethylene Glycol, Fuel Oil, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Methyl Chloride, Motor Oil, Nitric Acid, Paint, Phosphoric Acid, Salt Water, Soap Solutions, Sodium Hydroxide, Sulfuric Acid | 00000000 | 000000 |
3/4 NPT Female | 29" | 0 to 16 | 16 | 1,000 | 0.125 | 5 | 40° to 150° | Fluoroelastomer Rubber | Vertical | Water, Gasoline, Diesel Fuel, Kerosene, Ammonium Hydroxide, Bleach, Chlorine, Citric Acid, Deionized Water, Ethylene Glycol, Fuel Oil, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Methyl Chloride, Motor Oil, Nitric Acid, Paint, Phosphoric Acid, Salt Water, Soap Solutions, Sodium Hydroxide, Sulfuric Acid | 00000000 | 000000 |
1 NPT Female | 24" | 0 to 32 | 32 | 2,000 | 0.25 | 10 | 40° to 150° | Fluoroelastomer Rubber | Vertical | Water, Gasoline, Diesel Fuel, Kerosene, Ammonium Hydroxide, Bleach, Chlorine, Citric Acid, Deionized Water, Ethylene Glycol, Fuel Oil, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Methyl Chloride, Motor Oil, Nitric Acid, Paint, Phosphoric Acid, Salt Water, Soap Solutions, Sodium Hydroxide, Sulfuric Acid | 00000000 | 00000000 |
1 NPT Female | 39" | 0 to 64 | 64 | 4,000 | 0.25 | 20 | 40° to 150° | Fluoroelastomer Rubber | Vertical | Water, Gasoline, Diesel Fuel, Kerosene, Ammonium Hydroxide, Bleach, Chlorine, Citric Acid, Deionized Water, Ethylene Glycol, Fuel Oil, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Methyl Chloride, Motor Oil, Nitric Acid, Paint, Phosphoric Acid, Salt Water, Soap Solutions, Sodium Hydroxide, Sulfuric Acid | 00000000 | 00000000 |