About Actuated On/Off Valves
More
Matching Flow Diagrams to Replace an Air Directional Control Valve
More
Choosing an Air Directional Control Valve
More
Two-Speed Two-Action Air-Operated Air Directional Control Valves
Often used to extend and then retract a cylinder at different speeds, these valves create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Also known as pilot valves and 4-way valves, they use an air signal to actuate, so they're good for environments where electrical use may be dangerous. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion.
Valves without air-assisted spring return actuation go back to their starting position as soon as the air supply is removed.
Those with air-assisted spring return actuation require you to supply air to port P to go back to their starting position.
Valves with air pilot return actuation go back to their starting position when the air supply is moved from the first air pilot to the second air pilot.
NPTF (Dryseal) threads are compatible with NPT threads.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
For technical drawings and 3-D models, click on a part number.
O'all | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Min. Actuation Pressure, psi | No. of Flow Ports | No. of Air Pilot Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Air Pilot Size | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Lg. | Wd. | Ht. | Mounting Fasteners Included | Each | |
Threaded Female Inlet × Threaded Female Outlet × Threaded Female Pilot | ||||||||||||||||
Not Air-Assisted Spring Return Actuation | ||||||||||||||||
44 | 5 | 1 | 3/8 NPTF | 3/8 NPTF | Threaded | 1/8 NPT | 53.1 | 1.6 | 0-150 | 10 | 6 1/8" | 1 1/4" | 2 1/4" | No | 0000000 | 0000000 |
Air-Assisted Spring Return Actuation | ||||||||||||||||
44 | 5 | 1 | 1/8 NPT | 1/8 NPT | Threaded | 1/8 NPT | 43.1 | 1.3 | 0-145 | 26 | 4 1/8" | 7/8" | 1 3/8" | No | 00000000 | 00000 |
44 | 5 | 1 | 1/4 NPT | 1/4 NPT | Threaded | 1/8 NPT | 43.1 | 1.3 | 0-145 | 26 | 5 1/8" | 1" | 1 5/8" | No | 00000000 | 000000 |
44 | 5 | 1 | 1/2 NPTF | 1/2 NPTF | Threaded | 1/8 NPT | 165.9 | 5 | 0-150 | 26 | 6 5/8" | 1 1/2" | 2 1/2" | No | 0000000 | 000000 |
44 | 5 | 1 | 10-32 UNF | 10-32 UNF | Threaded | 10-32 UNF | 8.6 | 0.26 | 0-150 | 26 | 2 3/8" | 5/8" | 1" | No | 0000000 | 000000 |
Air Pilot Return Actuation | ||||||||||||||||
29 | 5 | 2 | 1/8 NPT | 1/8 NPT | Threaded | 1/8 NPT | 43.1 | 1.3 | 0-145 | 26 | 4 1/8" | 7/8" | 1 3/8" | No | 00000000 | 000000 |
29 | 5 | 2 | 1/4 NPT | 1/4 NPT | Threaded | 1/8 NPT | 43.1 | 1.3 | 0-145 | 26 | 5" | 1" | 1 5/8" | No | 00000000 | 000000 |
29 | 5 | 2 | 3/8 NPTF | 3/8 NPTF | Threaded | 1/8 NPT | 53.1 | 1.6 | 0-150 | 10 | 6 5/8" | 1 1/4" | 2 1/4" | No | 0000000 | 000000 |
29 | 5 | 2 | 1/2 NPTF | 1/2 NPTF | Threaded | 1/8 NPT | 165.9 | 5 | 0-150 | 26 | 6 5/8" | 1 1/2" | 2 1/2" | No | 0000000 | 000000 |
29 | 5 | 2 | 10-32 UNF | 10-32 UNF | Threaded | 10-32 UNF | 8.6 | 0.26 | 0-150 | 26 | 2 3/8" | 5/8" | 1" | No | 0000000 | 000000 |
Two-Speed Two-Action Air-Operated Air
Directional Control Valves with Full Shut-Off
In the off position, these valves stop equipment in a locked position with air pressure holding it in place. Often used to extend and then retract a cylinder at different speeds, they create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. They actuate by air signal, so they're good for environments where electrical use may be dangerous. Valves direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is by air, so they go back to their starting position when the air supply is moved from the first air pilot to the second air pilot. Also known as 4-way and 5/3 closed center valves.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Min. Actuation Pressure, psi | No. of Flow Ports | No. of Air Pilot Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Air Pilot Size | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Lg. | Wd. | Ht. | Mounting Fasteners Included | Each | |
Threaded Female Inlet × Threaded Female Outlet × Threaded Female Air Pilot | ||||||||||||||||
44 | 5 | 2 | 1/8 NPT | 1/8 NPT | Threaded | 1/8 NPT | 42 | 0.5 | 26-145 | 26 | 4 3/4" | 7/8" | 1 3/8" | No | 00000000 | 0000000 |
44 | 5 | 2 | 1/4 NPT | 1/4 NPT | Threaded | 1/8 NPT | 73 | 0.95 | 26-145 | 26 | 5 5/8" | 1" | 1 5/8" | No | 00000000 | 000000 |
Single-Action Air-Operated Air Directional Control Valves
These valves create one action, such as extending a cylinder. Also known as 3/2 or pilot valves, they use an air signal to actuate, so they're good for environments where electrical use may be dangerous. They direct airflow from an inlet to your equipment and exhaust return airflow to create motion. In the off position, they exhaust air pressure from the system, allowing equipment to reset so the action can be repeated.
Normally closed valves normally block airflow, and remain closed until actuated. Valves that are both normally closed and normally open can be installed to normally block airflow, or to normally allow flow and remain open until actuated.
Valves with spring return actuation go back to their starting position as soon as the air supply is removed. Valves with air pilot return actuation go back to their starting position when the air supply is moved from the first air pilot to the second air pilot.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
For technical drawings and 3-D models, click on a part number.
O'all | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Min. Actuation Pressure, psi | No. of Flow Ports | No. of Air Pilot Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Air Pilot Size | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Lg. | Wd. | Ht. | Mounting Fasteners Included | Each | |
Normally Closed Valve Starting Position | ||||||||||||||||
Spring Return Actuation | ||||||||||||||||
44 | 3 | 1 | 1/8 NPT | 1/8 NPT | Threaded | 1/8 NPT | 24.9 | 0.75 | 0-145 | 26 | 3 1/2" | 7/8" | 1 3/8" | No | 00000000 | 0000000 |
44 | 3 | 1 | 1/4 NPT | 1/4 NPT | Threaded | 1/8 NPT | 24.9 | 0.75 | 0-145 | 26 | 4 1/4" | 1" | 1 5/8" | No | 00000000 | 000000 |
44 | 3 | 1 | 3/8 NPTF | 3/8 NPTF | Threaded | 1/8 NPT | 53.1 | 1.6 | 0-150 | 10 | 5 1/8" | 1 1/4" | 2 1/4" | No | 0000000 | 000000 |
Normally Open/Normally Closed Valve Starting Position | ||||||||||||||||
Air Pilot Return Actuation | ||||||||||||||||
29 | 3 | 2 | 1/8 NPT | 1/8 NPT | Threaded | 1/8 NPT | 24.9 | 0.75 | 0-145 | 26 | 3 1/2" | 7/8" | 1 3/8" | No | 00000000 | 000000 |
29 | 3 | 2 | 1/4 NPT | 1/4 NPT | Threaded | 1/8 NPT | 24.9 | 0.75 | 0-145 | 26 | 4 1/8" | 1" | 1 5/8" | No | 00000000 | 000000 |
29 | 3 | 2 | 3/8 NPTF | 3/8 NPTF | Threaded | 1/8 NPT | 53.1 | 1.6 | 0-150 | 10 | 5 1/2" | 1 1/4" | 2 1/4" | No | 0000000 | 000000 |
Threaded Air-Driven Diverting Valves
- Valve Type: Ball
- For Use With: Air, Argon, Helium, Krypton, Neon, Oil, Steam, Water, Xenon
- Seal Material: PTFE Plastic
- Specifications Met: C-UL Listed, UL Listed
To divert flow between ports more quickly than motor-driven valves, these operate on compressed air. You must control the air to the actuator using either the included electric pilot valve or a manual on/off valve (not included). Valves don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and wear. Valves are standard port, so they slightly restrict flow.
Air-to-divert/air-to-return valves require air pressure to divert flow to the right-port outlet and air pressure to return flow to the left-port outlet.
Air-to-divert/spring-return valves require air pressure to divert flow to the right-port outlet. They automatically return flow to the left-port outlet when the air turns off to ensure the valve only diverts flow to the right port when air is on.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Air | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flow Pattern | Flow Coefficient (Cv) | Max. Pressure | Max. Steam Pressure | Pressure Range, psi | Connection | Pressure Drop | Min. Pressure Drop Required | Temp. Range, °F | Valve Lg. | O'all Ht. | Wire Connection Type | Vacuum Rating, in. of Hg | Each | |
Brass Body—NPT Female × NPT Female × NPT Female | |||||||||||||||
Single Acting: Air-to-Divert / Spring Return—120V AC | |||||||||||||||
1/4 | L-Pattern | 3.26 | 400 psi @ 175° F | 100 psi @ 340° F | 60 to 125 | 1/4 NPT Female | Zero Pressure Drop | None | -4° to 340° | 2 11/16" | 5 7/8" | DIN | 29 | 0000000 | 0000000 |
3/8 | L-Pattern | 3.5 | 400 psi @ 175° F | 100 psi @ 340° F | 60 to 125 | 1/4 NPT Female | Zero Pressure Drop | None | -4° to 340° | 2 11/16" | 5 7/8" | DIN | 29 | 0000000 | 000000 |
1/2 | L-Pattern | 4.2 | 400 psi @ 175° F | 100 psi @ 340° F | 60 to 125 | 1/4 NPT Female | Zero Pressure Drop | None | -4° to 340° | 2 7/8" | 5 7/8" | DIN | 29 | 0000000 | 000000 |
3/4 | L-Pattern | 7 | 400 psi @ 175° F | 100 psi @ 340° F | 60 to 125 | 1/4 NPT Female | Zero Pressure Drop | None | -4° to 340° | 3 3/16" | 6" | DIN | 29 | 0000000 | 000000 |
1 | L-Pattern | 12.83 | 400 psi @ 175° F | 100 psi @ 340° F | 60 to 125 | 1/4 NPT Female | Zero Pressure Drop | None | -4° to 340° | 3 3/4" | 6 9/16" | DIN | 29 | 0000000 | 000000 |
1 1/2 | L-Pattern | 29.75 | 400 psi @ 175° F | 100 psi @ 340° F | 60 to 125 | 1/4 NPT Female | Zero Pressure Drop | None | -4° to 340° | 4 7/8" | 8 3/16" | DIN | 29 | 0000000 | 000000 |
2 | L-Pattern | 43.76 | 400 psi @ 175° F | 100 psi @ 340° F | 60 to 125 | 1/4 NPT Female | Zero Pressure Drop | None | -4° to 340° | 5 3/4" | 10 5/16" | DIN | 29 | 0000000 | 000000 |
Double Acting: Air-to-Divert / Air-to-Return—120V AC | |||||||||||||||
1/4 | L-Pattern | 3.26 | 400 psi @ 175° F | 100 psi @ 340° F | 60 to 125 | 1/4 NPT Female | Zero Pressure Drop | None | -4° to 340° | 2 11/16" | 4 3/4" | DIN | 29 | 0000000 | 000000 |
3/8 | L-Pattern | 3.5 | 400 psi @ 175° F | 100 psi @ 340° F | 60 to 125 | 1/4 NPT Female | Zero Pressure Drop | None | -4° to 340° | 2 11/16" | 4 3/4" | DIN | 29 | 0000000 | 000000 |
1/2 | L-Pattern | 4.2 | 400 psi @ 175° F | 100 psi @ 340° F | 60 to 125 | 1/4 NPT Female | Zero Pressure Drop | None | -4° to 340° | 2 7/8" | 4 3/4" | DIN | 29 | 0000000 | 000000 |
3/4 | L-Pattern | 7 | 400 psi @ 175° F | 100 psi @ 340° F | 60 to 125 | 1/4 NPT Female | Zero Pressure Drop | None | -4° to 340° | 3 3/16" | 4 15/16" | DIN | 29 | 0000000 | 000000 |
1 | L-Pattern | 12.83 | 400 psi @ 175° F | 100 psi @ 340° F | 60 to 125 | 1/4 NPT Female | Zero Pressure Drop | None | -4° to 340° | 3 3/4" | 6 9/16" | DIN | 29 | 0000000 | 000000 |
1 1/2 | L-Pattern | 29.75 | 400 psi @ 175° F | 100 psi @ 340° F | 60 to 125 | 1/4 NPT Female | Zero Pressure Drop | None | -4° to 340° | 4 7/8" | 7 3/4" | DIN | 29 | 0000000 | 000000 |
2 | L-Pattern | 43.76 | 400 psi @ 175° F | 100 psi @ 340° F | 60 to 125 | 1/4 NPT Female | Zero Pressure Drop | None | -4° to 340° | 5 3/4" | 9 1/16" | DIN | 29 | 0000000 | 000000 |
Flanged Air-Driven Diverting Valves
- Valve Type: Ball
- For Use With: Air, Argon, Helium, Krypton, Neon, Oil, Steam, Water, Xenon
- Seal Material: Viton® Fluoroelastomer Rubber
Automatically divert flow between ports in flanged pipelines with these valves that operate on compressed air for faster actuation than motor-driven valves. You must control the air to the actuator using either an electric pilot valve (sold separately) or a manual on/off valve (not included). Valves do not require a minimum pressure drop between the inlet and outlet for operation. Valves are standard port, so they slightly restrict flow.
The actuator is secured to the valve body with a bracket for easy disassembly, maintenance, and repair. A visual flow indicator on the top of the actuator shows which direction flow is being diverted.
Air-to-divert/air-to-return valves require air pressure to divert flow to the right-port outlet and air pressure to return flow to the left-port outlet.
Air-to-divert/spring-return valves require air pressure to divert flow to the right-port outlet. They automatically return flow to the left-port outlet when the air turns off to ensure the valve only diverts flow to the right port when air is on.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Bolts | Air | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Pressure Class | Flange OD | Hole Size | No. of Holes | Circle Dia. | Included | Flow Coefficient (Cv) | Max. Pressure | Max. Steam Pressure @ Temp. | Pressure Range, psi | Connection | Pressure Drop | Temp. Range, °F | Actuation Time | Valve Lg. | Each | |
316 Stainless Steel Body—Flanged × Flanged × Flanged | |||||||||||||||||
Single Acting: Air-to-Divert / Spring Return | |||||||||||||||||
2 | 150 | 6" | 3/4" | 4 | 4 3/4" | No | 133.4 | 275 psi @ 100° F | 50 psi @ 295° F | 40 to 120 | 1/4 NPT Female | Zero Pressure Drop | 0° to 300° | 1.2 sec. | 4 1/2" | 0000000 | 000000000 |
3 | 150 | 7 1/2" | 3/4" | 4 | 6" | No | 313.2 | 275 psi @ 100° F | 50 psi @ 295° F | 40 to 120 | 1/4 NPT Female | Zero Pressure Drop | 0° to 300° | 1.2 sec. | 5 7/8" | 0000000 | 00000000 |
4 | 150 | 9" | 3/4" | 8 | 7 1/2" | No | 504.6 | 275 psi @ 100° F | 50 psi @ 295° F | 40 to 120 | 1/4 NPT Female | Zero Pressure Drop | 0° to 300° | 1.2 sec. | 6 1/4" | 0000000 | 00000000 |
Double Acting: Air-to-Divert / Air-to-Return | |||||||||||||||||
2 | 150 | 6" | 3/4" | 4 | 4 3/4" | No | 133.4 | 275 psi @ 100° F | 50 psi @ 295° F | 40 to 120 | 1/8 NPT Female | Zero Pressure Drop | 0° to 300° | 0.75 sec. | 4 1/2" | 0000000 | 00000000 |
3 | 150 | 7 1/2" | 3/4" | 4 | 6" | No | 313.2 | 275 psi @ 100° F | 50 psi @ 295° F | 40 to 120 | 1/8 NPT Female | Zero Pressure Drop | 0° to 300° | 0.75 sec. | 5 7/8" | 0000000 | 00000000 |
4 | 150 | 9" | 3/4" | 8 | 7 1/2" | No | 504.6 | 275 psi @ 100° F | 50 psi @ 295° F | 40 to 120 | 1/4 NPT Female | Zero Pressure Drop | 0° to 300° | 1 sec. | 6 1/4" | 0000000 | 00000000 |
- Valve Type: Solenoid
- For Use With: Air, Argon, Helium, Krypton, Neon, Oil, Water, Xenon
Flow Pattern | Valve Starting Position | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | Actuation Time | Valve Lg. | Each | |
110V AC | ||||||||
---|---|---|---|---|---|---|---|---|
Aluminum Body with Screw Terminals | ||||||||
L-Pattern | Normally Closed | 1.68 | 120 psi @ 80° F | 35° to 130° | 0.2 sec. | 3 7/8" | 0000000 | 000000 |
24V DC | ||||||||
Aluminum Body with Screw Terminals | ||||||||
L-Pattern | Normally Closed | 1.68 | 120 psi @ 80° F | 35° to 130° | 0.2 sec. | 3 7/8" | 0000000 | 00000 |
High-Purity Air-Driven Diverting Valves for Food and Beverage
- Valve Type: Plug
- For Use With: Beverage, Food
- Seal Material: EPDM Rubber
- Specifications Met: 3-A Certified 53-06
Often used in sanitary valve manifolds, these valves can be cleaned in place to eliminate the risk of cross contamination in food, beverage, and dairy lines. They are 3-A certified and electropolished to a 23 Ra finish for smooth internal surfaces that prevent product buildup and inhibit bacteria growth to maintain sanitary standards. All have sanitary quick-clamp fittings for easy disassembly. Valves operate on compressed air to automatically divert flow between ports more quickly than motor-driven valves. You must control the air to the actuator using either an electric pilot valve (not included) or a manual on/off valve (not included). Body is 316 stainless steel for excellent corrosion resistance. The actuator is secured to the valve body with a bracket for easy disassembly, maintenance, and repair.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Air | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube OD | Flow Pattern | Flow Coefficient (Cv) | Max. Pressure | Pressure Range, psi | Connection | Max. Temp., °F | Actuation Time | Valve Lg. | Port-to-Port Lg. | Interior Smoothness | Each | |
316 Stainless Steel Body—Quick Clamp × Quick Clamp × Quick Clamp | ||||||||||||
Single Acting: Air-to-Divert / Spring Return | ||||||||||||
1" | L-Pattern, U-Pattern | 15 | 175 psi @ 190° F | 70 to 115 | 1/4 NPT Female | 190° | 2 sec. | 3 7/16" | 2 1/4" | 23 Ra | 0000000 | 000000000 |
2" | L-Pattern, U-Pattern | 54 | 75 psi @ 190° F | 70 to 115 | 1/4 NPT Female | 190° | 2 sec. | 5 1/16" | 3 1/8" | 23 Ra | 0000000 | 00000000 |
3" | L-Pattern, U-Pattern | 119 | 70 psi @ 190° F | 70 to 115 | 1/4 NPT Female | 190° | 2 sec. | 6 9/16" | 3 7/8" | 23 Ra | 0000000 | 00000000 |
Air-Driven Diverting Valves for Food and Beverage
- Valve Type: Ball
- For Use With: Beverage, Food
- Seal Material: PTFE Plastic
For food and beverage systems that require frequent cleaning, these valves have sanitary quick-clamp connections for easy disassembly. They operate on compressed air to divert flow between ports between ports more quickly than motor-driven valves. You must control the air supply to the actuator using either an electric pilot valve (not included) or a manual on/off valve (not included). These valves don’t require a minimum pressure drop between the inlet and outlet for operation. All are full port, so they do not restrict flow.
Body is 316 stainless steel for excellent corrosion resistance. The actuator is directly mounted to the valve body to minimize movement and wear. A visual flow indicator on the top of the actuator shows which direction flow is being diverted.
Air-to-divert/air-to-return valves require air pressure to divert flow to the right-port outlet and air pressure to return flow to the left-port outlet.
Air-to-divert/spring-return valves require air pressure to divert flow to the right-port outlet. They automatically return flow to the left-port outlet when the air turns off to ensure the valve only diverts flow to the right port when air is on.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
For Tube | Air | Mounting Holes | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ID | OD | Flow Pattern | Flow Coefficient (Cv) | Max. Pressure | Pressure Range, psi | Connection Pipe Size | Connection Gender | Pressure Drop | Temp. Range, °F | Actuation Time | Valve Lg. | Mounting Fasteners Included | No. of | Dia. | Each | |
316 Stainless Steel Body—Quick Clamp × Quick Clamp × Quick Clamp | ||||||||||||||||
Single Acting: Air-to-Divert / Spring Return | ||||||||||||||||
3/8" | 1/2" | L-Pattern | 6 | 115 psi @ 120° F | 80 to 150 | 1/8 | Female | Zero Pressure Drop | -30° to 500° | 1 sec. | 4 21/64" | No | 4 | 3/8" | 0000000 | 000000000 |
5/8" | 3/4" | L-Pattern | 16 | 115 psi @ 120° F | 80 to 150 | 1/4 | Female | Zero Pressure Drop | -30° to 500° | 1 sec. | 5 33/64" | No | 5 | 7/16" | 0000000 | 00000000 |
7/8" | 1" | L-Pattern | 31 | 115 psi @ 120° F | 80 to 150 | 1/4 | Female | Zero Pressure Drop | -30° to 500° | 1 sec. | 6 19/64" | No | 6 | 7/16" | 0000000 | 00000000 |
1 3/8" | 1 1/2" | L-Pattern | 75 | 115 psi @ 120° F | 80 to 150 | 1/4 | Female | Zero Pressure Drop | -30° to 500° | 2 sec. | 7 7/8" | No | 7 | 3/4" | 0000000 | 00000000 |
1 7/8" | 2" | L-Pattern | 140 | 115 psi @ 120° F | 80 to 150 | 1/4 | Female | Zero Pressure Drop | -30° to 500° | 2 sec. | 8 21/32" | No | 8 | 3/4" | 0000000 | 00000000 |
Double Acting: Air-to-Divert / Air-to-Return | ||||||||||||||||
3/8" | 1/2" | L-Pattern | 6 | 115 psi @ 120° F | 80 to 150 | 1/8 | Female | Zero Pressure Drop | -30° to 500° | 1 sec. | 4 21/64" | No | 9 | 3/8" | 0000000 | 000000 |
5/8" | 3/4" | L-Pattern | 16 | 115 psi @ 120° F | 80 to 150 | 1/8 | Female | Zero Pressure Drop | -30° to 500° | 1 sec. | 5 33/64" | No | 10 | 7/16" | 0000000 | 00000000 |
7/8" | 1" | L-Pattern | 31 | 115 psi @ 120° F | 80 to 150 | 1/4 | Female | Zero Pressure Drop | -30° to 500° | 1 sec. | 6 19/64" | No | 11 | 7/16" | 0000000 | 00000000 |
1 3/8" | 1 1/2" | L-Pattern | 75 | 115 psi @ 120° F | 80 to 150 | 1/4 | Female | Zero Pressure Drop | -30° to 500° | 1 sec. | 7 7/8" | No | 12 | 3/4" | 0000000 | 00000000 |
1 7/8" | 2" | L-Pattern | 140 | 115 psi @ 120° F | 80 to 150 | 1/4 | Female | Zero Pressure Drop | -30° to 500° | 1 sec. | 8 21/32" | No | 13 | 3/4" | 0000000 | 00000000 |
- Valve Type: Solenoid
- For Use With: Beverage, Food
- Seal Material: Buna-N Rubber
Flow Pattern | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Min. Pressure Drop Required | Temp. Range, °F | Actuation Time | Valve Lg. | Each | |
120V AC | |||||||||
---|---|---|---|---|---|---|---|---|---|
Aluminum Body with DIN Connection | |||||||||
L-Pattern | 1.4 | 150 psi @ 120° F | Pressure Drop Assisted | 5 psi | 35° to 120° | 1 sec. | 5 13/16" | 0000000 | 0000000 |
24V DC | |||||||||
Aluminum Body with DIN Connection | |||||||||
L-Pattern | 1.4 | 150 psi @ 120° F | Pressure Drop Assisted | 5 psi | 35° to 120° | 1 sec. | 5 13/16" | 0000000 | 000000 |