About Hazardous Location Environmental Ratings
More
Choosing an Electrical Switch
More
Hazardous Location 22 mm Panel-Mount Push-Button Switches
A housing seals in anything that could ignite flammable material, so you can use these switches where explosive gas, dust, and fibers may be. They actuate with a quick push. You’ll know they’re safe because they’re UL listed and meet NEC Class I, Division 2, Groups A, B, C, and D for hazardous locations. Install them in a standard panel cutout. The buttons are distinct colors to help you identify switches without reading labels.
Those that are illuminated make switches easier to see in low light.
Switches come with a contact block for each number of circuits they control. Additional contact blocks (sold separately) can be added to control more circuits or replace the included contact block.
For technical drawings and 3-D models, click on a part number.







No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Actuator Color | Switching Current @ Voltage | Dia. | Dp. Behind Panel | For Max. No. of Contact Blocks | Bulb Voltage | Each | |
Metal Base with Screw Terminals—(600V AC/300V DC Max. Voltage) | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Flush | ||||||||||||
1 | 1 Off (Normally Open) | Springs Back (Momentary) | 3 | SPST-NO | Black | 6 A @ 120 V AC, 2.8 A @ 24 V DC | 1 3/16" | 2 1/4" | 6 | __ | 0000000 | 0000000 |
1 | 1 Off (Normally Open) | Springs Back (Momentary) | 3 | SPST-NO | Green | 6 A @ 120 V AC, 2.8 A @ 24 V DC | 1 3/16" | 2 1/4" | 6 | __ | 0000000 | 000000 |
1 | 1 Off (Normally Open) | Springs Back (Momentary) | 3 | SPST-NO | White | 6 A @ 120 V AC, 2.8 A @ 24 V DC | 1 3/16" | 2 1/4" | 6 | __ | 0000000 | 000000 |
1 | 1 On (Normally Closed) | Springs Back (Momentary) | 3 | SPST-NC | Red | 6 A @ 120 V AC, 2.8 A @ 24 V DC | 1 3/16" | 2 1/4" | 6 | __ | 0000000 | 000000 |
Metal Base with Screw Terminals—Illuminated (600V AC/300V DC Max. Voltage) | ||||||||||||
Flush | ||||||||||||
1 | 1 Off (Normally Open) | Springs Back (Momentary) | 3 | SPST-NO | Green | 6 A @ 120 V AC, 2.8 A @ 24 V DC | 1 1/8" | 2 1/4" | 6 | 24V AC/24V DC | 0000000 | 000000 |
1 | 1 Off (Normally Open) | Springs Back (Momentary) | 3 | SPST-NO | White | 6 A @ 120 V AC, 2.8 A @ 24 V DC | 1 1/8" | 2 1/4" | 6 | 24V AC/24V DC | 0000000 | 000000 |
1 | 1 On (Normally Closed) | Springs Back (Momentary) | 3 | SPST-NC | Red | 6 A @ 120 V AC, 2.8 A @ 24 V DC | 1 1/8" | 2 1/4" | 6 | 24V AC/24V DC | 0000000 | 000000 |
Hazardous Location 30 mm Panel-Mount Push-Button Switches
Actuate these switches with a quick push. A housing seals in anything that could ignite flammable material, so you can use them where ignitable gas and dust may be present. You’ll know they’re safe because they meet NEC Class I Div. 2, Groups B, C, D for hazardous locations. Install them in a standard panel cutout.
Switches come with a contact block for each number of circuits they control. Additional contact blocks (sold separately) can be added to control more circuits, or to replace the included contact block.
For technical drawings and 3-D models, click on a part number.


No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Actuator Color | Switching Current @ Voltage | Max. Voltage | Dia. | For Max. Panel Thick. | Dp. Behind Panel | For Max. No. of Contact Blocks | Each | |
Plastic Base with Screw Terminals | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flush | |||||||||||||
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | Black | 6 A @ 120 V AC, 5.75 A @ 24 V DC | 250V DC 600V AC | 1 3/8" | 3/8" | 2 3/16" | 2 | 000000 | 0000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | Green | 6 A @ 120 V AC, 5.75 A @ 24 V DC | 250V DC 600V AC | 1 3/8" | 3/8" | 2 3/16" | 2 | 000000 | 000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | Red | 6 A @ 120 V AC, 5.75 A @ 24 V DC | 250V DC 600V AC | 1 3/8" | 3/8" | 2 3/16" | 2 | 000000 | 000000 |
Projecting | |||||||||||||
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | Black | 6 A @ 120 V AC, 5.75 A @ 24 V DC | 250V DC 600V AC | 1 3/8" | 3/8" | 2 3/16" | 2 | 000000 | 000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | Red | 6 A @ 120 V AC, 5.75 A @ 24 V DC | 250V DC 600V AC | 1 3/8" | 3/8" | 2 3/16" | 2 | 000000 | 000000 |

For Push-Button Style | No. of Circuits Controlled | Switch Starting Position | No. of Terminals | Industry Designation | Each | |
Projecting, Flush | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | 4 | DPST-1NO/1NC | 0000000 | 000000 |
Hazardous Location 30 mm Emergency
Stop Panel-Mount Push-Button Switches
Switches immediately cut power with a single push. Use these switches where ignitable gas and dust may be present. Their contact blocks are explosion proof and UL listed for Class I, Division 2, Groups B, C, and D hazardous locations. All are rated NEMA 4X and IP65 for protection from corrosion and washdowns. They include enough contact blocks to control the number of circuits listed.
Additional contact blocks (sold separately) can be added to control more circuits, or replace the included contact block.
For technical drawings and 3-D models, click on a part number.

No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Actuator Color | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | For Max. No. of Contact Blocks | Each | |
Metal Base with Screw Terminals | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Pull Reset | ||||||||||||
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | Red | 6 A @ 120 V AC, 5.75 A @ 24 V DC | 250V DC 600V AC | 1 1/2" | 2 3/16" | 2 | 000000 | 0000000 |
Turn Reset | ||||||||||||
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | Red | 6 A @ 120 V AC, 5.75 A @ 24 V DC | 250V DC 600V AC | 1 1/2" | 2 3/16" | 2 | 000000 | 000000 |

No. of Circuits Controlled | Switch Starting Position | No. of Terminals | Industry Designation | Each | |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | 4 | DPST-1NO/1NC | 0000000 | 000000 |
Hazardous Location Enclosed Push-Button Switches





Use these switches where ignitable gas and dust may be present. They're rated for use in hazardous locations.
For technical drawings and 3-D models, click on a part number.
Mounting | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Message (Actuator Color) | No. of Circuits Controlled per Button | Switch Starting Position | Switch Action | No. of Terminals per Button | Industry Designation | Switching Current @ Voltage | Max. Voltage | Conduit Trade Size | Fasteners Included | No. of Holes | Hole Dia. | Each | |
With Screw Terminals | |||||||||||||
1 Mushroom Button | |||||||||||||
Stop (Red) | 1 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 10 A @ 120 V AC | 600V AC | 3/4 | No | 2 | 3/16" | 0000000 | 0000000 |
1 Flush Button | |||||||||||||
Start (Black) | 1 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | 10 A @ 120 V AC | 600V AC | 3/4 | No | 2 | 5/16" | 0000000 | 000000 |
1 Flush Button and 1 Projecting Button | |||||||||||||
Start (Green), Stop (Red) | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 2 | DPST-1NO/1NC | 10 A @ 120 V AC | 600V AC | 3/4 | No | 2 | 9/32" | 0000000 | 000000 |
Hazardous Location Enclosed Lever Switches

Use these switches where ignitable gas, dust, and fibers may be present. They're UL and C-UL listed for hazardous locations.
For technical drawings and 3-D models, click on a part number.
Mounting | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Actuator Color | Message (Switch Position) | No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Fasteners Included | No. of Holes | Hole Dia. | Each | |
3 Positions | |||||||||||||
With Screw Terminals | |||||||||||||
Gray | Hand (Left), Off (Center), Auto (Right) | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 10 A @ 120 V AC | 600V AC | No | 2 | 5/16" | 0000000 | 0000000 |
Hazardous Location Foot Switches


These switches are rated for environments where hazardous material is present. Press the pedal with your foot for hands-free operation. They have an oversized guard that accommodates bulky footwear.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment. See About Hazardous Location Environmental Ratings.
Mounting | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switch Action | Industry Designation | Switching Current @ Voltage | Fasteners Included | No. of Holes | Hole Dia. | Environmental Rating | Each | |
1 Speed with Screw Terminals | ||||||||||
Aluminum Housing with 1 Pedal, Oversized Guard, and Back Pivot | ||||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Springs Back (Momentary) | SPDT | 20 A @ 125 V AC/250 V AC | No | 6 | 0.28" | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups F, G NEC Zone 1 Group IIA IP41 NEMA 2 NEMA 7 NEMA 9 | 0000000 | 0000000 |
2 | 2 Off (Normally Open) or 2 On (Normally Closed) | Springs Back (Momentary) | DPDT | 20 A @ 125 V AC/250 V AC | No | 6 | 0.28" | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups F, G NEC Zone 1 Group IIA IP41 NEMA 2 NEMA 7 NEMA 9 | 0000000 | 000000 |
Aluminum Housing with 2 Pedals, Oversized Guard, and Back Pivot | ||||||||||
2 | 1 Off (Normally Open) or 1 On (Normally Closed) | Springs Back (Momentary) | SPDT | 20 A @ 125 V AC/250 V AC | No | 6 | 0.28" | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups F, G NEC Zone 1 Group IIA IP41 NEMA 2 NEMA 7 NEMA 9 | 0000000 | 000000 |
Hazardous Location Cable-Pull Emergency Stop Switches

Safe to use near ignitable gases and dust, the housing on these switches seals in anything that could ignite flammable material. All are UL listed and CSA certified for use in hazardous locations. Yank the cable anywhere along your line to quickly cut power in emergencies. They have positive-force, snap-open contacts that open a circuit when actuated, even if a spring fails or the contacts stick. The contacts will remain open until you tension the cable and reset the switch. Use the tension indicator to visually confirm that they’re reset correctly.
For technical drawings and 3-D models, click on a part number.
Mounting | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Max. Cable Lg., ft. | No. of Circuits Controlled | Switch Starting Position | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Actuation Force, lbs. | Conduit Trade Size | Fasteners Included | Hole Dia. (No. of Holes) | Hole Thread Size (No. of Holes) | Features | Each | |
With Screw Terminals | ||||||||||||||
1 Direction (NEMA 4; NEMA 7; NEMA 9; NEMA 13; NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G) | ||||||||||||||
200 | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 3 | SPDT | 10 A @ 600 V AC, 10 A @ 250 V DC | 250V DC/600V AC | 25 | 1/2 | No | 1/4" (2) | 5/16"-18 (2) | Tension Indicator | 0000000 | 000000000 |
200 | 2 | 2 On (Normally Closed) | 4 | DPST-NC | 10 A @ 600 V AC, 10 A @ 250 V DC | 250V DC/600V AC | 25 | 1/2 | No | 1/4" (2) | 5/16"-18 (2) | Tension Indicator | 0000000 | 00000000 |