How to Prime Your Pump
More
How to Determine Feet of Head
More
About Process Pumps
More
Low-Maintenance Plastic Circulation Pumps for Water and Coolants
Eliminate seal wear and leakage with pumps that use magnets to turn the impeller. They’re often used with electroplating and photographic solutions. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.

Flow Rate, gpm | Intake | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 5 ft. of Head | @ 10 ft. of Head | Max. ft of Head | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Current, A | Tube Connection Type | Gender | For Tube ID | Tube Connection Type | Gender | For Tube ID | Lg. | Wd. | Ht. | Each | |
115V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Plug | ||||||||||||||||||
3 | 1 | 0.1 | 10.6 | 4 | 20 | 35° to 150° | 0.8 | Barbed | Male | 1/2" | Barbed | Male | 1/2" | 6 3/4" | 3 3/4" | 4 7/8" | 0000000 | 0000000 |

Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 5 ft. of Head | @ 10 ft. of Head | Max. ft of Head | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | hp | Current, A | Tube Connection Type | Gender | For Tube ID | Tube Connection Type | Gender | For Tube ID | Lg. | Wd. | Ht. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug | |||||||||||||||||||
5 | 2 | __ | 7 | 3 | 20 | 35° to 150° | 1/50 | 0.94 | Barbed | Male | 5/8" | Barbed | Male | 5/8" | 7 5/8" | 3 1/2" | 5 1/4" | 0000000 | 0000000 |
7 | 7 | 5 | 19 | 8 | 20 | 35° to 150° | 1/25 | 1.65 | Barbed | Male | 5/8" | Barbed | Male | 5/8" | 8 1/4" | 3 1/2" | 5 1/4" | 0000000 | 000000 |

Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 10 ft. of Head | @ 20 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | hp | Current, A | Pipe Size | Gender | Thread Type | Pipe Size | Gender | Thread Type | Lg. | Wd. | Ht. | Each | |
115V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug | |||||||||||||||||||
9 | 5 | __ | 16.1 | 7 | 20 | 35° to 150° | 1/20 hp | 1.4 | 1/2 | Female | NPT | 1/2 | Male | NPT | 8 7/8" | 3 3/4" | 4 7/8" | 0000000 | 0000000 |
14 | 11 | 4 | 24.7 | 10 | 20 | 35° to 150° | 1/10 hp | 1.7 | 1 | Female | NPT | 1/2 | Male | NPT | 9 5/8" | 5 1/2" | 4 7/8" | 0000000 | 000000 |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug | |||||||||||||||||||
8 | 5 | __ | 14.6 | 6 | 20 | 35° to 150° | 1/30 | 1.5 | 1/2 | Female | NPT | 1/2 | Male | NPT | 8 1/2" | 4" | 4 3/8" | 0000000 | 000000 |
11 | 8 | 3 | 23.7 | 10 | 20 | 35° to 150° | 1/12 | 2.4 | 1/2 | Female | NPT | 1/2 | Male | NPT | 9" | 4" | 4 3/8" | 0000000 | 000000 |
12 | 9 | 2 | 21.9 | 9 | 20 | 35° to 150° | 1/12 | 2.4 | 3/4 | Female | NPT | 1/2 | Male | NPT | 9 7/8" | 4" | 5" | 0000000 | 000000 |
15 | 12 | 8 | 34.6 | 15 | 20 | 35° to 150° | 1/8 | 2.1 | 1/2 | Female | NPT | 1/2 | Male | NPT | 8 3/8" | 5 1/2" | 5 5/8" | 0000000 | 000000 |
17 | 13 | 8 | 27.5 | 11 | 20 | 35° to 150° | 1/8 | 2 | 1 | Female | NPT | 1/2 | Male | NPT | 8 3/4" | 5 1/2" | 5 1/2" | 0000000 | 000000 |
Harsh-Environment Low-Maintenance Plastic
Circulation Pumps for Water and Coolants

These pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. The impeller is turned with magnets to eliminate seal wear and leakage for a long service life. Pumps are often used with electroplating and photographic solutions. They are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Pumps | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | Impellers | |||||||||||||||
Max. Flow Rate, gpm | @ 5 ft. of Head | @ 10 ft. of Head | @ 20 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug | |||||||||||||||||||
10 | __ | 6 | __ | 16.3 | 7 | 20 | 1/25 | 1.3 | 1/2 | Female | 1/2 | Male | 9" | 4" | 5" | 00000000 | 0000000 | 000000 | 00 |
14 | __ | 12 | 4 | 24.3 | 10 | 20 | 1/10 | 1.7 | 1 | Female | 1/2 | Male | 10 7/8" | 5 1/2" | 5" | 00000000 | 000000 | 000000 | 00 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
10 | 7 | 5 | __ | 16.3 | 7 | 20 | 1/20 | 0.8 | 1/2 | Female | 1/2 | Male | 8 1/2" | 4" | 4 3/8" | 0000000 | 000000 | 000000 | 00 |
14 | __ | 12 | 4 | 24.3 | 10 | 20 | 1/10 | 0.7 | 1 | Female | 1/2 | Male | 10 5/8" | 5 1/2" | 5" | 0000000 | 000000 | 000000 | 00 |
120/240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
18 | 17 | 15 | 11 | 29 | 50 | 5 | 1/5 | 2.6/1.3 | 1 | Female | 1/2 | Male | 12 1/4" | 7 1/4" | 7" | 0000000 | 000000 | 0000000 | 0000000 |
Plug | |||||||||||||||||||
20 | __ | 17 | 11 | 29.3 | 10 | 20 | 1/8 | 3/1.4 | 1 | Female | 1/2 | Male | 11 1/4" | 5 1/4" | 7 3/8" | 0000000 | 000000 | 000000 | 00 |
High-Flow Harsh-Environment Low-Maintenance
Plastic Circulation Pumps for Water and Coolants

A powerful motor provides twice the flow rate of other extended-life circulation pumps. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Magnets turn the impeller to eliminate seal wear and leakage for a long service life. These pumps are often used with electroplating and photographic solutions. They are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | Impellers | ||||||||||||||||
Max. Flow Rate, gpm | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | @ 60 ft. of Head | Max. ft. of Head | Max. Pressure, psi | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | Each | ||
120/240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Hardwire | ||||||||||||||||||||
32 | 25 | 19 | __ | __ | __ | 40.5 | 17 | 1/3 | 5/2.5 | 1 | Female | 3/4 | Male | 16 1/4" | 8 7/8" | 7" | 00000000 | 000000000 | 000000 | 00 |
38 | 32 | 28 | 21 | __ | __ | 51 | 21 | 1/2 | 9.4/4.7 | 1 | Female | 3/4 | Male | 16 1/4" | 8 7/8" | 7" | 00000000 | 00000000 | 000000 | 00 |
53 | __ | 41 | 33 | 28 | 1 | 60 | 50 | 3/4 | 10/5 | 1 1/2 | Female | 1 | Male | 17 7/8" | 9" | 9" | 0000000 | 00000000 | 0000000 | 0000000 |
53 | 42 | 37 | 28 | 18 | __ | 58.9 | 25 | 3/4 | 11.8/5.9 | 1 1/2 | Female | 1 | Male | 17 1/4" | 8 5/8" | 8 1/2" | 00000000 | 00000000 | 000000 | 00 |
240/460V AC, Three Phase—With Thermal Overload Protection | ||||||||||||||||||||
Hardwire | ||||||||||||||||||||
38 | 32 | 28 | 21 | __ | __ | 51 | 21 | 1/2 | 1.8/0.9 | 1 | Female | 3/4 | Male | 15 1/4" | 8 3/4" | 7" | 00000000 | 00000000 | 000000 | 00 |
53 | 42 | 37 | 28 | 18 | __ | 58.9 | 25 | 3/4 | 2.9/1.5 | 1 1/2 | Female | 1 | Male | 17 1/4" | 8 5/8" | 8 5/8" | 00000000 | 00000000 | 000000 | 00 |
Extended-Life Inline Circulation Pumps for Water

Eliminate seal wear and leakage—these pumps have magnets that turn the impeller for a long service life. Install them directly in your pipeline for applications such as hot-water circulation and hydronic heating and cooling. Mount vertically or horizontally; the electrical conduit box must be placed on the bottom. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 5 ft. of Head | @ 10 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | hp | Current, A | Pipe Size | Gender | Thread Type | Pipe Size | Gender | Thread Type | Lg. | Wd. | Ht. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
4 | __ | __ | 4.3 | 150 | 1 | 35° to 250° | 1/100 | 0.5 | 1/2 | Male | NPT | 1/2 | Male | NPT | 5 3/8" | 3 3/8" | 6 5/8" | 0000000 | 0000000 |
6 | 5 | 3 | 12.1 | 150 | 1 | 35° to 250° | 1/25 | 1.4 | 1/2 | Male | NPT | 1/2 | Male | NPT | 5 3/8" | 3 3/8" | 7 3/4" | 0000000 | 000000 |
Extended-Life Plastic Circulation Pumps for Chemicals

These pumps have the best chemical resistance of all our circulation pumps. Instead of a shaft seal, they use magnets to turn the impeller, reducing wear and leakage. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Pipe Size | Overall | Maintenance Kits | Replacement Impellers | |||||||||||||||||
Max. Flow Rate, gpm | @ 10 ft. of Head | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | @ 60 ft. of Head | Max. ft. of Head | Max. Viscosity, cP | hp | Current, A | Intake (Gender) | Discharge (Gender) | Lg. | Wd. | Ht. | Each | Each | Each | |||
120V AC, 240V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||||||
Hardwire | |||||||||||||||||||||
23 | __ | 20 | 10 | __ | __ | __ | 35 | __ | 1/4 | 2.07/4.14 | 1 (Female) | 1 (Female) | 14 3/8" | 5 1/8" | 7 7/8" | 0000000 | 000000000 | 00000000 | 000000 | 00000000 | 0000000 |
26 | __ | 26 | 12 | __ | __ | __ | 35 | __ | 1/3 | 3.24/6.84 | 1 (Female) | 1 (Female) | 16 5/16" | 6 1/8" | 8 3/16" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
240V AC, 460V AC, Three Phase—Without Thermal Overload Protection | |||||||||||||||||||||
Hardwire | |||||||||||||||||||||
57 | 57 | 53 | 30 | 25 | __ | __ | 45 | __ | 1/2 | 1.1/2.2 | 1 1/2 (Female) | 1 1/2 (Female) | 18 3/8" | 8 7/8" | 11 5/16" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
90 | 90 | 84 | 74 | 61 | 49 | __ | 70 | __ | 1 | 1.5/3 | 1 1/2 (Female) | 1 1/2 (Female) | 18 7/8" | 6 5/16" | 10 1/8" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
120V AC, 208–240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||||
Hardwire | |||||||||||||||||||||
38 | 36 | 32 | 27 | 21 | __ | __ | 49 | 5 | 1/2 | 7.5/3.7-3.7 | 1 (Female) | 3/4 (Male) | 15 1/2" | 9" | 8 1/4" | 0000000 | 00000000 | 00000000 | 0000 | 00000000 | 000000 |
53 | 53 | 46 | 40 | 33 | 23 | 2 | 60 | 5 | 1 | 9.2/6.3-4.6 | 1 1/2 (Female) | 1 (Male) | 17 13/16" | 9 1/8" | 8 3/16" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
208–240V AC, 460V AC, Three Phase—Without Thermal Overload Protection | |||||||||||||||||||||
Hardwire | |||||||||||||||||||||
30 | 31 | 26 | 20 | 7 | __ | __ | 41 | 5 | 1/3 | 0.6/1.3-1.2 | 1 (Female) | 3/4 (Male) | 15 1/16" | 9 1/4" | 7 3/8" | 0000000 | 00000000 | 00000000 | 0000 | 00000000 | 000000 |
38 | 36 | 32 | 27 | 21 | __ | __ | 49 | 5 | 1/2 | 1.7/1.7-0.8 | 1 (Female) | 3/4 (Male) | 15 1/16" | 9 1/8" | 7 3/16" | 0000000 | 00000000 | 00000000 | 0000 | 00000000 | 000000 |
53 | 53 | 46 | 40 | 33 | 23 | 2 | 60 | 5 | 1 | 1.1/3.3-2.2 | 1 1/2 (Female) | 1 (Male) | 16 9/16" | 9 1/8" | 7 3/8" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
82 | 82 | 82 | 81 | 80 | 71 | 61 | 85 | 5 | 2 | 2.4/4.9-4.8 | 2 (Male) | 1 1/2 (Male) | 20 11/16" | 10 3/8" | 10" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 00000000 |
120 | 120 | 120 | 120 | 112 | 105 | 92 | 95 | 5 | 3 | 3.9/8-7.8 | 2 (Male) | 1 1/2 (Male) | 24 3/8" | 11 1/2" | 10 1/2" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 00000000 |
Impellers for Circulation Pumps

Match your pump’s manufacturer and model number to choose the right replacement impeller.
For Pump Model Number | For Pump Part Number | Kit Number | Each | |
Anderson Process | ||||
---|---|---|---|---|
AM Series | TM2FE-ER-VT-076-AA | TM-M3L23E-Z | 00000000 | 0000000 |
AM Series | TM2GE-ER-VT-090-AA | TM-M5L02E-Z | 00000000 | 000000 |
AMX Series | TM4HC-EC-VT-090-BA | TM-X0L05EC | 00000000 | 000000 |
AMX Series | TM4KC-EC-VT-108-BA | TM-X1L05EC | 00000000 | 000000 |
March | ||||
Series 4 & 5 | TE-5C-MD | 0150-0148-0200 | 0000000 | 000000 |
Series 5.5 | 0151-0027-0300, 0151-0027-0900 | 0151-0046-0300 | 00000000 | 000000 |
Series 6 | 0153-0002-0400, 0153-0002-0500 | 0153-0043-0500 | 00000000 | 000000 |
Series 7 | 0155-0173-0200, 0155-0174-0200 | 0155-0160-0200 | 00000000 | 000000 |
Series 7 & 7.5 | TE-7R-MD | 0155-0165-0100 | 0000000 | 000000 |
Series 7.5 | 0156-0001-0100 | 0156-0004-0200 | 00000000 | 00000000 |
Series 8 | 0157-0008-0200 | 0157-0050-0500 | 00000000 | 00000000 |