Choosing a Proximity Switch
More
Choosing an Electrical Switch
More
Magnetic Contact Alarm Switches
Wire contacts to an alarm system to alert when doors or windows are opened. Mount the magnet to the door or window and mount the switch to the frame. The alarm will activate when the magnet is pulled away by the opening door or window.
SPDT switches connect to an alarm system and to another device, such as a motion detector.
Style | No. of Circuits Controlled | Switch Starting Position | Industry Designation | Switching Current @ Voltage | Max. Sensing Distance | Wire Lead Lg., ft. | Lg. | Wd. | Ht. | Color | Environment | Environmental Rating | Each | |
Plastic Housing with Screw Terminals | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Screw On with Sealed Housing | ||||||||||||||
A | 1 | 1 Off (Normally Open) | SPST-NO | 0.5 A @ 100 V AC/100 V DC | 0.75" | __ | 2.5" | 0.56" | 0.5" | Gray | __ | NEMA 4X, NEMA 6, NEMA 12, IP67 | 0000000 | 00000 |
A | 1 | 1 Off (Normally Open) | SPST-NO | 0.5 A @ 100 V AC/100 V DC | 1.25" | __ | 3.93" | 0.75" | 0.62" | Gray | __ | NEMA 1, IP62 | 0000000 | 00000 |
A | 1 | 1 Off (Normally Open) | SPST-NO | 0.5 A @ 100 V AC/100 V DC | 1.25" | __ | 3.93" | 0.75" | 0.62" | White | __ | NEMA 1, IP62 | 0000000 | 00000 |
A | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 0.25 A @ 30 V AC/30 V DC | 0.75" | __ | 2.5" | 0.56" | 0.5" | White | __ | __ | 0000000 | 00000 |
A | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 0.25 A @ 30 V AC/30 V DC | 1.25" | __ | 3.93" | 0.75" | 0.62" | White | __ | __ | 0000000 | 00000 |
Plastic Housing with Wire Leads | ||||||||||||||
Adhesive Back with Sealed Housing | ||||||||||||||
A | 1 | 1 Off (Normally Open) | SPST-NO | 0.5 A @ 100 V AC/100 V DC | 0.62" | 1 | 1.5" | 0.25" | 0.37" | White | Corrosive, Oily, Outdoor, Washdown, Submersible | NEMA 4X, NEMA 6, NEMA 12, IP67 | 0000000 | 0000 |
Aluminum Housing with Wire Leads | ||||||||||||||
Screw On with Flexible Stainless Steel Conduit and Sealed Housing | ||||||||||||||
A | 1 | 1 Off (Normally Open) | SPST-NO | 0.5 A @ 100 V AC/100 V DC | 3" | 3 | 3" | 0.5" | 1" | __ | Corrosive, Washdown, Temporary Submersion | NEMA 4X, NEMA 6, NEMA 12, IP67 | 0000000 | 00000 |
A | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 0.25 A @ 30 V AC/30 V DC | 3" | 3 | 3" | 0.5" | 1" | __ | Corrosive, Washdown, Temporary Submersion | NEMA 4X, NEMA 6, NEMA 12, IP67 | 0000000 | 00000 |
B | 1 | 1 Off (Normally Open) | SPST-NO | 0.5 A @ 100 V AC/100 V DC | 3" | 3 | 3.5" | 1.5" | 1.5" | __ | Corrosive, Washdown, Temporary Submersion | NEMA 4X, NEMA 6, NEMA 12, IP67 | 0000000 | 00000 |
B | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 0.25 A @ 30 V AC/30 V DC | 3" | 3 | 3.5" | 1.5" | 1.5" | __ | Corrosive, Washdown, Temporary Submersion | NEMA 4X, NEMA 6, NEMA 12, IP67 | 0000000 | 00000 |
C | 1 | 1 Off (Normally Open) | SPST-NO | 0.5 A @ 100 V AC/100 V DC | 6" | 1 1/2 | 6.12" | 0.5" | 1" | __ | __ | __ | 00000000 | 00000 |
D | 1 | 1 Off (Normally Open) | SPST-NO | 0.5 A @ 100 V AC/100 V DC | 3" | 2 | 3.62" | 0.68" | 3" | __ | Corrosive, Oily, Outdoor, Washdown, Submersible | NEMA 4X, NEMA 6, NEMA 12, IP67 | 00000000 | 00000 |
Magnetically Actuated Switches
These switches actuate when a magnet comes within sensing distance, and reset when the magnet moves away. They’re often used to detect when a door or window opens. Mount the switch in a stationary position, such as a door frame, and mount the magnet to a movable object, such as the door. They do not include a safety relay and cannot be used with safety-guard doors found on machinery.
NEMA 4X rated switches are protected from corrosion and washdowns. These switches are also rated IP67 for protection from temporary submersion.
For technical drawings and 3-D models, click on a part number.
Magnetically Actuated Switches | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mounting Thread | Replacement Magnets | |||||||||||||||
No. of Circuits Controlled | Switch Starting Position | Industry Designation | Switching Current @ Voltage | Max. Voltage | Max. Sensing Distance | No. of Wire Leads | Dia. | Lg. | Wd. | Ht. | Size | Each | Each | |||
Plastic Housing with Wire Leads | ||||||||||||||||
A | 1 | 1 Off (Normally Open) | SPST-NO | 1 A @ 24 V DC | 200V DC | 0.44" | 2 | __ | 1.1" | 0.33" | 0.21" | __ | 000000000 | 000000 | 000000000 | 000000 |
A | 1 | 1 On (Normally Closed) | SPST-NC | 1 A @ 24 V DC | 150V DC | 0.25" | 2 | __ | 1.1" | 0.33" | 0.21" | __ | 000000000 | 00000 | 000000000 | 00000 |
A | 1 | 1 On (Normally Closed) | SPST-NC | 1 A @ 24 V DC | 150V DC | 0.31" | 2 | __ | 1.1" | 0.33" | 0.21" | __ | 000000000 | 00000 | 000000000 | 00000 |
B | 1 | 1 Off (Normally Open) | SPST-NO | 1 A @ 24 V DC | 200V DC | 0.31" | 2 | __ | 1.125" | 0.75" | 0.25" | __ | 000000000 | 00000 | 000000000 | 00000 |
B | 1 | 1 Off (Normally Open) | SPST-NO | 2 A @ 24 V DC | 400V DC | 0.25" | 2 | __ | 1.13" | 0.75" | 0.25" | __ | 00000000 | 00000 | 000000000 | 00000 |
B | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 1 A @ 24 V DC | 150V DC | 0.2" | 3 | __ | 1.13" | 0.75" | 0.25" | __ | 00000000 | 00000 | 000000000 | 00000 |
B | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 1 A @ 24 V DC | 150V DC | 0.44" | 3 | __ | 1.125" | 0.75" | 0.25" | __ | 000000000 | 00000 | 000000000 | 00000 |
C | 1 | 1 Off (Normally Open) | SPST-NO | 1 A @ 24 V DC | 200V DC | 0.25" | 2 | 0.31" | 1.5" | __ | __ | 5/16"-24 | 000000000 | 00000 | 000000000 | 00000 |
C | 1 | 1 Off (Normally Open) | SPST-NO | 2 A @ 24 V DC | 400V DC | 0.2" | 2 | 0.31" | 1.5" | __ | __ | 5/16"-24 | 00000000 | 00000 | 000000000 | 00000 |
C | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 1 A @ 24 V DC | 150V DC | 0.13" | 3 | 0.31" | 1.5" | __ | __ | 5/16"-24 | 00000000 | 00000 | 000000000 | 00000 |
C | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 1 A @ 24 V DC | 150V DC | 0.31" | 3 | 0.31" | 1.5" | __ | __ | 5/16"-24 | 000000000 | 00000 | 000000000 | 00000 |
D | 1 | 1 Off (Normally Open) | SPST-NO | 0.4 A @ 24 V DC | 170V DC | 0.15" | 2 | 0.18" | 0.43" | __ | __ | __ | 00000000 | 00000 | 000000000 | 00000 |
D | 1 | 1 Off (Normally Open) | SPST-NO | 1 A @ 24 V DC | 200V DC | 0.31" | 2 | 0.25" | 1" | __ | __ | __ | 000000000 | 00000 | 000000000 | 00000 |
D | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 1 A @ 24 V DC | 150V DC | 0.19" | 3 | 0.25" | 1" | __ | __ | __ | 000000000 | 00000 | 000000000 | 00000 |
F | 1 | 1 Off (Normally Open) | SPST-NO | 1 A @ 24 V DC | 200V DC | 0.56" | 2 | __ | 1.75" | 0.25" | 0.26" | __ | 000000000 | 00000 | 000000000 | 00000 |
F | 1 | 1 Off (Normally Open) | SPST-NO | 2 A @ 24 V DC | 400V DC | 0.62" | 2 | __ | 1.75" | 0.25" | 0.26" | __ | 000000000 | 00000 | 000000000 | 00000 |
F | 1 | 1 Off (Normally Open) | SPST-NO | 3 A @ 24 V DC | 400V DC | 0.94" | 2 | __ | 2.625" | 0.34" | 0.34" | __ | 000000000 | 00000 | 000000000 | 00000 |
F | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 1 A @ 24 V DC | 150V DC | 0.62" | 3 | __ | 1.75" | 0.25" | 0.26" | __ | 000000000 | 00000 | 000000000 | 00000 |
F | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 3 A @ 24 V DC | 120V DC | 0.81" | 3 | __ | 2.625" | 0.34" | 0.34" | __ | 000000000 | 000000 | 000000000 | 00000 |
G | 1 | 1 Off (Normally Open) | SPST-NO | 2 A @ 24 V DC | 400V DC | 0.94" | 2 | __ | 2.53" | 0.625" | 0.75" | __ | 000000000 | 00000 | 000000000 | 00000 |
G | 1 | 1 Off (Normally Open) | SPST-NO | 3 A @ 24 V DC | 400V DC | 0.94" | 2 | __ | 2.53" | 0.625" | 0.75" | __ | 000000000 | 00000 | 000000000 | 00000 |
Plastic Housing with Wire Leads—NEMA 4X, IP67 | ||||||||||||||||
A | 1 | 1 Off (Normally Open) | SPST-NO | 2 A @ 30 V AC, 2 A @ 60 V DC | 250V AC/250V DC | 0.8" | 2 | __ | 3.16" | 0.79" | 0.59" | __ | 00000000 | 000000 | 00000000 | 00000 |
B | 1 | 1 Off (Normally Open) | SPST-NO | 80 mA @ 120 V AC | 250V AC | 0.4" | 2 | __ | 1.13" | 0.71" | 0.25" | __ | 00000000 | 000000 | 00000000 | 00000 |
D | 1 | 1 Off (Normally Open) | SPST-NO | 80 mA @ 120 V AC | 250V AC | 0.1" | 2 | 0.24" | 1.12" | __ | __ | __ | 00000000 | 000000 | 00000000 | 00000 |
Stainless Steel Housing with Wire Leads | ||||||||||||||||
E | 1 | 1 Off (Normally Open) | SPST-NO | 1 A @ 24 V DC | 200V DC | 0.38" | 2 | 0.31" | 1.25" | __ | __ | 5/16"-24 | 000000000 | 00000 | 000000000 | 00000 |
E | 1 | 1 Off (Normally Open) | SPST-NO | 2 A @ 24 V DC, 2 A @ 120 V AC | 400V AC | 0.13" | 2 | 0.31" | 1.25" | __ | __ | 5/16"-24 | 00000000 | 00000 | 000000000 | 00000 |
E | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 0.8 A @ 24 V DC | 150V DC | 0.2" | 3 | 0.31" | 1.25" | __ | __ | 5/16"-24 | 00000000 | 00000 | 000000000 | 00000 |
E | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 1 A @ 24 V DC | 150V DC | 0.44" | 3 | 0.31" | 1.25" | __ | __ | 5/16"-24 | 000000000 | 00000 | 000000000 | 00000 |
Aluminum Housing with Wire Leads | ||||||||||||||||
E | 1 | 1 Off (Normally Open) | SPST-NO | 1 A @ 24 V DC | 200V DC | 0.56" | 2 | 0.31" | 1.5" | __ | __ | 5/16"-24 | 000000000 | 00000 | 000000000 | 00000 |
E | 1 | 1 Off (Normally Open) | SPST-NO | 2 A @ 24 V DC | 400V DC | 0.31" | 2 | 0.31" | 1.5" | __ | __ | 5/16"-24 | 000000000 | 00000 | 000000000 | 00000 |
E | 1 | 1 Off (Normally Open) | SPST-NO | 2.5 A @ 24 V DC | 400V DC | 0.19" | 2 | 0.31" | 1.25" | __ | __ | 5/16"-24 | 00000000 | 00000 | 000000000 | 00000 |
E | 1 | 1 Off (Normally Open) | SPST-NO | 3 A @ 24 V DC | 400V DC | 0.56" | 2 | 0.38" | 2.125" | __ | __ | 3/8"-27 | 000000000 | 00000 | 000000000 | 00000 |
E | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 1 A @ 24 V DC | 150V DC | 0.31" | 3 | 0.31" | 1.5" | __ | __ | 5/16"-24 | 000000000 | 00000 | 000000000 | 00000 |
E | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 1 A @ 24 V DC | 150V DC | 0.31" | 3 | 0.31" | 1.5" | __ | __ | 5/16"-24 | 000000000 | 00000 | 000000000 | 00000 |
E | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 3 A @ 24 V DC | 120V DC | 0.44" | 3 | 0.38" | 2.125" | __ | __ | 3/8"-27 | 000000000 | 000000 | 000000000 | 00000 |
Tamper-Resistant Magnetically Actuated Switches
Prevent unauthorized use—these switches require coded magnets (sold separately) to actuate, and cannot be bypassed using ordinary magnets. They actuate when a magnet comes within sensing distance, and reset when the magnet moves away. Mount the switch in a stationary position, such as a door frame, and mount the magnet to a movable object, such as the door. They’re often used to detect when a door or window opens, and can be used with movable machine guards. All are rated IP67 for protection from temporary submersion.
Coded magnets include tamper-resistant one-way screws for mounting. To remove screws, see one-way bits and drivers.
Safety relays are required in safety applications with switches that control two or three circuits.
For technical drawings and 3-D models, click on a part number.
Switches | Coded Magnets | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Industry Designation | Switching Current @ Voltage | Max. Voltage | Input Voltage | Max. Sensing Distance | Dia. | Lg. | Mounting Thread Size | Environmental Rating | Each | Each | ||
Plastic Housing with Wire Leads | ||||||||||||||
1 | 1 On (Normally Closed) | SPST-NC | 6.3 A @ 120 V AC | 250V AC | 24V DC | 0.2" | 1.2" | 3.1" | M30 | IP67 | 0000000 | 0000000 | 0000000 | 000000 |
Switches | Coded Magnets | Safety Relays | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Industry Designation | Switching Current @ Voltage | Max. Voltage | Input Voltage | Max. Sensing Distance | Lg. | Wd. | Ht. | Environmental Rating | Each | Each | Each | |||
Plastic Housing with Wire Leads | ||||||||||||||||
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | DPST-1NO/1NC | 0.5 A @ 120 V AC/120 V DC | 120V DC 120V AC | 120V DC 120V AC | 0.2" | 3.5" | 1" | 0.5" | IP67 | 0000000 | 0000000 | 0000000 | 000000 | 0000000 | 0000000 |
3 | 1 Off (Normally Open) and 2 On (Normally Closed) | 3PST-1NO/2NC | 10 mA @ 24 V DC | 24V DC | 24V DC | 0.2" | 3.5" | 1" | 0.5" | IP67 | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 000000 |
Circuit Board Magnetically Actuated Switches
Mounted to your circuit board, these switches trigger when magnetic components get near, and reset as they move away. They’re often used to turn on electronics, such as starting up a laptop when you open it. To install, push the contacts through holes in a circuit board, then solder them in place.
Switches with a plastic housing withstand impact better than switches with a glass housing. The plastic also forms an airtight seal to block out contaminants. Use them in dusty or dirty environments where an optical switch might fail.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Industry Designation | Switching Current @ Voltage | Max. Voltage | Wire Dia. | OD | Lg. | Specifications Met | Pkg. Qty. | Pkg. | |
1 | 1 Off (Normally Open) | SPST-NO | 0.5 A @ 200 V DC | 250V DC | 0.02" | 0.1" | 0.6" | UL Recognized Component, C-UL Recognized Component | 20 | 0000000 | 000000 |
No. of Circuits Controlled | Switch Starting Position | Industry Designation | Switching Current @ Voltage | Max. Voltage | Wire Dia. | Lg. | Wd. | Ht. | Protection Type | Environmental Rating | Specifications Met | Includes | Pkg. Qty. | Pkg. | |
1 | 1 Off (Normally Open) | SPST-NO | 0.5 A @ 200 V DC | 250V DC | 0.02" | 0.6" | 0.1" | 0.1" | Hermetically Sealed | NEC Class I Division 2 Groups A, B, C, D | UL Recognized Component, C-UL Recognized Component | Magnet | 20 | 0000000 | 000000 |
DC Magnetic-Object Proximity Switches
These switches detect magnetic objects—or objects with a magnet attached—through non-magnetic walls. They’re often used to count magnetic items on a conveyor belt that are too far for other proximity switches to detect and in food plants to track cleaners through stainless steel pipe. Producing a PNP signal output, these switches are commonly used with programmable logic controllers (PLCs). Resistant to dust, heat, and vibration, switches will stand up to harsh environments. Magnets are sold separately.
Maximum sensing distance in the table below represents switches used with the magnet shown. Sensing distance will vary depending on the magnetic strength of the object your switch is detecting.
For technical drawings and 3-D models, click on a part number.
Switches | Magnets | Cables with Socket | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switch Starting Position | Dia., mm | Max. Sensing Distance, mm | Magnetic Sensitivity | Signal Output Type | Switching Frequency, kHz | Input Voltage | Current Output | Lg., mm | Cable Lead Lg., ft. | Temp. Range, °F | Each | Each | Each | |||
Nickel-Plated Brass Housing with Plastic Face (IP67) | ||||||||||||||||
Flush with 3-Pole Nano M8 Plug | ||||||||||||||||
1 Off (Normally Open) | 8 | 55 | 10 G | PNP | 1 | 10V DC-30V DC | 200mA | 46 | __ | -10° to 165° | 0000000 | 0000000 | 0000000 | 000000 | 0000000 | 000000 |
1 On (Normally Closed) | 8 | 55 | 10 G | PNP | 1 | 10V DC-30V DC | 200mA | 46 | __ | -10° to 165° | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
Flush with 4-Pole Micro M12 Plug | ||||||||||||||||
1 Off (Normally Open) | 12 | 55 | 10 G | PNP | 1 | 10V DC-30V DC | 200mA | 46 | __ | -10° to 165° | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
1 Off (Normally Open) | 12 | 81 | 6 G | PNP | 1 | 10V DC-30V DC | 200mA | 63 | __ | -10° to 165° | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
1 Off (Normally Open) | 18 | 105 | 4 G | PNP | 5 | 10V DC-30V DC | 200mA | 60 | __ | -10° to 165° | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
1 On (Normally Closed) | 18 | 69 | 7 G | PNP | 5 | 10V DC-30V DC | 200mA | 50 | __ | -10° to 165° | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
Flush with Wire Leads | ||||||||||||||||
1 Off (Normally Open) | 8 | 55 | 10 G | PNP | 1 | 10V DC-30V DC | 200mA | 48 | 6 1/2 | -10° to 165° | 0000000 | 000000 | 0000000 | 00000 | 000000 | 00 |
1 Off (Normally Open) | 12 | 81 | 6 G | PNP | 1 | 10V DC-30V DC | 200mA | 50 | 6 1/2 | -10° to 165° | 0000000 | 000000 | 0000000 | 00000 | 000000 | 00 |
1 Off (Normally Open) | 18 | 105 | 4 G | PNP | 5 | 10V DC-30V DC | 200mA | 58 | 6 1/2 | -10° to 165° | 0000000 | 000000 | 0000000 | 00000 | 000000 | 00 |
1 On (Normally Closed) | 8 | 55 | 10 G | PNP | 1 | 10V DC-30V DC | 200mA | 48 | 10 | -10° to 165° | 0000000 | 000000 | 0000000 | 00000 | 000000 | 00 |
1 On (Normally Closed) | 12 | 55 | 10 G | PNP | 1 | 10V DC-30V DC | 200mA | 48 | 6 1/2 | -10° to 165° | 0000000 | 000000 | 0000000 | 00000 | 000000 | 00 |
Circuit Board DC Magnetic-Object Proximity Switches
Send signals in response to changing magnetic fields to trigger processes or monitor position, speed, and current. These switches communicate with devices such as programmable logic controllers (PLCs) and microcontrollers. They’re also known as hall effect sensors. To install, push their contacts through holes in a circuit board, then solder them in place.
Maintained switches change their output signal based on the polarity of a magnetic field. They’re often used to monitor movement, such as tracking the speed and position of a shaft. These switches output a high-voltage signal when they detect a north pole, and a low-voltage signal for a south pole. When the magnetic field is removed, they maintain the same output signal.
Momentary switches change their output signal based on whether a magnetic field is present. They’re often used to trigger a process in response to changing magnetic fields, such as turning on a light when a door opens. When they detect a north or south pole, they output a low-voltage signal. When they don’t detect a magnetic field at all, they output a high-voltage signal.
For technical drawings and 3-D models, click on a part number.
Switch Action | Switch Starting Position | Setpoint, G | Approximate Difference Between Setpoint and Reset Point, G | Switching Frequency, kHz | Switching Current @ Voltage | Max. Voltage | Wire Dia. | Lg., mm | Wd., mm | Ht., mm | Temp. Range, °F | Pkg. Qty. | Pkg. | |
Plastic Housing | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Maintained | 1 Off (Normally Open) or 1 On (Normally Closed) | 90 | __ | 10 | 5 mA @ 24 V DC | 24V DC | 0.015" | 3 | 4 | 2 | -40° to 185° | 10 | 0000000 | 000000 |
Momentary | 1 On (Normally Closed) | 395 | 40 | Not Rated | 0.008 mA @ 3 V DC | 5.5V DC | 0.015" | 3 | 4 | 2 | -40° to 255° | 10 | 0000000 | 00000 |
Magnetic-Contact Door Chimes
No electricity or batteries are needed—as your door opens, the magnet and contact disc are separated, sounding a mechanical chime. The chime can be deactivated.
O'all | Volume | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Material | Color | Control | @ Distance | For Use Outdoors | Mount Type | Mount. Fasteners Included | Each | |
5 3/4" | 2" | 2 3/4" | Plastic | Brown | Fixed | 88 dB @ 10 ft. | No | Surface | Yes | 0000000 | 000000 |
Key-Controlled Door Alarms with Strobe Light
Attract more attention with a strobe light as well as an audible alarm. Arm and disarm these alarms with a key. They sound an alarm and emit short, intense bursts of light when a door is opened without authorization and the alarm and magnetic contact are separated. All require a mortise lock cylinder (sold separately) for operation.
Mount an optional rim lock cylinder (not included) on the opposite side of the door to arm and disarm these alarms from the outside.
Keypad-Controlled Door Alarms
Arm and disarm these alarms with a programmable code. They sound an alarm when a door is opened without authorization and the alarm and magnetic contact are separated.
An optional exterior keypad (sold separately) allows the alarm to be armed and disarmed from the outside.
O'all | Mount. Location | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Material | Color | Volume | Sound Pattern | Combination Type | For Use Outdoors | Batteries Included | Features | Alarm | Contact | Mount. Fasteners Included | Each | |
2 1/2" | 9" | 2 3/8" | Painted Aluminum | Dark Brown | 95 dBA @ 10 ft. | Continuous, Pulse | Five Numbers | No | Yes | LED Indicating Light | Door | Door Frame | Yes | 0000000 | 0000000 |
2 1/2" | 9" | 2 3/8" | Aluminum | __ | 95 dBA @ 10 ft. | Continuous, Pulse | Five Numbers | No | Yes | LED Indicating Light | Door | Door Frame | Yes | 0000000 | 000000 |
Optional Exterior Keypad | 0000000 | Each | 0000000 |
Key-Controlled Door Alarms
Arm and disarm these alarms with a key. They sound an alarm when a door is opened without authorization and the alarm and magnetic contact are separated. All require a mortise lock cylinder (sold separately) for operation.
Mount an optional rim lock cylinder (not included) on the opposite side of the door to arm and disarm these alarms from the outside.
O'all | Mount. Location | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Material | Appearance | Color | Volume @ Distance | Sound Pattern | For Use Outdoors | Batteries Included | Features | Alarm | Contact | Mount. Fasteners Included | Each | |
2 1/2" | 9" | 2 3/8" | Painted Aluminum | __ | Dark Brown | 95 dBA @ 10 ft. | Continuous, Pulse | No | Yes | LED Indicating Light | Door | Door Frame | Yes | 0000000 | 0000000 |
2 1/2" | 9" | 2 3/8" | Aluminum | Dull | __ | 95 dBA @ 10 ft. | Continuous, Pulse | No | Yes | LED Indicating Light | Door | Door Frame | Yes | 0000000 | 000000 |