Plastic Syringes
Made of plastic, these syringes are shatter resistant and suitable for use with a variety of liquids. However, they’re not as scratch resistant as glass or stainless steel syringes and less precise than glass ones.
Syringes with a luer slip connection connect to needles with a luer lock connection simply by sliding the needle onto the fitting—it will be held in place by friction rather than a locking mechanism.
Autoclavable syringes can be sterilized for reuse. Repeated sterilization may lead to discoloration over time.
For technical drawings and 3-D models, click on a part number.
Capacity | Barrel | Each | Package | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ml | fl. oz. | Graduation Marks | OD | ID | Lg. | Material | Piston Material | Autoclavable | Each | Pkg. Qty. | Pkg. | ||
Luer Slip Connection | |||||||||||||
Clear | |||||||||||||
1 | 0.03 | 0.01 ml | 0.27" | 0.18" | 2 11/16" | Polypropylene Plastic | Silicone Rubber | No | 0000000 | 00000 | 10 | 00000000 | 000000 |
3 | 0.1 | 0.1 ml | 0.47" | 0.37" | 2 3/4" | Polypropylene Plastic | Rubber | No | 000000 | 00 | 10 | 0000000 | 0000 |
5 | 0.17 | 0.2 ml | 0.55" | 0.48" | 3 1/16" | Polypropylene Plastic | Rubber | No | 000000 | 00 | 10 | 0000000 | 0000 |
10 | 0.34 | 0.2 ml | 0.66" | 0.58" | 3 7/8" | Polypropylene Plastic | Rubber | No | 000000 | 00 | 10 | 0000000 | 0000 |
15 | 0.51 | 1 ml | 0.80" | 0.71" | 3 5/8" | Polypropylene Plastic | Santoprene Rubber | Yes | 0000000 | 0000 | __ | 000000 | 00 |
20 | 0.68 | 1 ml | 0.87" | 0.78" | 4 7/16" | Polypropylene Plastic | Rubber | No | 000000 | 00 | 5 | 0000000 | 0000 |
30 | 1.01 | 1 ml | 0.94" | 0.85" | 4 3/4" | Polypropylene Plastic | Natural Rubber | No | 0000000 | 0000 | __ | 000000 | 00 |
35 | 1.18 | 1 ml | 1.00" | 0.91" | 4 11/16" | Polypropylene Plastic | Santoprene Rubber | Yes | 0000000 | 0000 | __ | 000000 | 00 |
50 | 1.69 | 1 ml | 1.17" | 1.05" | 5 13/16" | Polypropylene Plastic | Natural Rubber | No | 0000000 | 0000 | __ | 000000 | 00 |
60 | 2.03 | 1 ml | 1.36" | 1.26" | 4 3/4" | Polypropylene Plastic | Santoprene Rubber | Yes | 0000000 | 0000 | __ | 000000 | 00 |
80 | 2.71 | 5 ml | 1.36" | 1.25" | 5 1/2" | Polypropylene Plastic | Santoprene Rubber | Yes | 0000000 | 0000 | __ | 000000 | 00 |
100 | 3.38 | 5 ml | 1.36" | 1.25" | 7" | Polypropylene Plastic | Santoprene Rubber | Yes | 0000000 | 0000 | __ | 000000 | 00 |
Glass Syringes
Made to a tighter tolerance than plastic syringes, these glass syringes are better at dispensing small, precise samples with little left over. They’re also durable and resistant to chemicals, so they’re unlikely to wear or warp from your samples, so they'll have a long, reliable life. Their precision makes them great for gas chromatography.
For quick and easy needle connections, choose between luer lock and luer slip syringes. Syringes with a luer slip connection use friction to hold a luer lock needle in place. Since they don’t have a locking mechanism like luer lock syringes, their connection isn’t as strong.
Syringes without a piston resist wear and are nearly frictionless to operate. Syringes with a piston are ideal for use with gases because the piston creates a leak-free, gastight seal against the barrel. They’re also great for liquids that don’t fully mix—the piston’s seal wipes off any deposits from liquids. With no deposits, the plunger won’t get stuck while dispensing. The piston’s seal is also tight enough that the plunger won’t retract on its own, so you can dispense from these syringes in a slow, controlled manner.
Autoclavable syringes must be disassembled before autoclaving. Keep in mind that repeated autoclaving can reduce their lifespan, so chemical sterilization is preferred.
For technical drawings and 3-D models, click on a part number.
Capacity | Barrel | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
ml | fl. oz. | Graduation Marks | OD | ID | Lg. | Material | Color | Autoclavable | Each | |
Syringes | ||||||||||
0.01 | 0.0003 | 0.0001 ml | 0.26" | 0.02" | 3 3/16" | Borosilicate Glass | Clear | Yes | 0000000 | 000000 |
0.025 | 0.0008 | 0.00025 ml | 0.31" | 0.03" | 3 3/8" | Borosilicate Glass | Clear | Yes | 0000000 | 00000 |
0.05 | 0.001 | 0.0005 ml | 0.31" | 0.04" | 3 1/2" | Borosilicate Glass | Clear | Yes | 0000000 | 00000 |
0.1 | 0.003 | 0.001 ml | 0.31" | 0.06" | 3 1/2" | Borosilicate Glass | Clear | Yes | 0000000 | 00000 |
0.25 | 0.008 | 0.0025 ml | 0.31" | 0.09" | 3 1/2" | Borosilicate Glass | Clear | Yes | 0000000 | 00000 |
0.5 | 0.016 | 0.005 ml | 0.31" | 0.14" | 3 1/2" | Borosilicate Glass | Clear | Yes | 0000000 | 00000 |
Syringes with PTFE Plastic Piston | ||||||||||
0.01 | 0.0003 | 0.0001 ml | 0.26" | 0.02" | 3 5/8" | Borosilicate Glass | Clear | Yes | 0000000 | 00000 |
0.025 | 0.0008 | 0.00025 ml | 0.31" | 0.03" | 3 5/8" | Borosilicate Glass | Clear | Yes | 0000000 | 00000 |
0.05 | 0.0001 | 0.0005 ml | 0.31" | 0.04" | 3 5/8" | Borosilicate Glass | Clear | Yes | 0000000 | 00000 |
0.1 | 0.003 | 0.001 ml | 0.31" | 0.06" | 3 5/8" | Borosilicate Glass | Clear | Yes | 0000000 | 00000 |
0.25 | 0.008 | 0.0025 ml | 0.31" | 0.09" | 3 5/8" | Borosilicate Glass | Clear | Yes | 0000000 | 00000 |
0.5 | 0.016 | 0.005 ml | 0.31" | 0.13" | 3 1/2" | Borosilicate Glass | Clear | Yes | 0000000 | 00000 |
5 | 0.169 | 0.05 ml | 0.53" | 0.41" | 3 13/16" | Borosilicate Glass | Clear | Yes | 0000000 | 00000 |
10 | 0.338 | 0.1 ml | 0.70" | 0.57" | 3 1/2" | Borosilicate Glass | Clear | Yes | 0000000 | 000000 |
Precision-Dispensing Glass Syringes
A turn of the threaded plunger dispenses extremely small quantities—as small as a speck of dust. The fine threads on these syringes inch the plunger forward with every turn for a controlled, precise flow. You won’t accidentally push too much out with these syringes.
A glass barrel adds to their precision. It’s made to a tighter tolerance than a plastic barrel, so the plunger seals against the barrel and wipes it clean as it moves, dispensing every last drop. The glass barrel is also durable and resistant to chemicals, so it’s unlikely to wear or warp from your sample for a long, reliable life. Thanks to their precision, these syringes are often used for gas chromatography.
Attach a needle with a luer slip connection. Slide a needle onto the fitting and friction will hold it in place.
Before autoclaving these syringes, disassemble them. Keep in mind that autoclaving can reduce their lifespan, so chemical sterilization is preferred.
For technical drawings and 3-D models, click on a part number.
Capacity | Barrel | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
ml | fl. oz. | Dispensing Quantity per Revolution | Graduation Marks | OD | ID | Lg. | Material | Piston Material | Autoclavable | Features | Each | |
Luer Slip Connection | ||||||||||||
Clear | ||||||||||||
0.025 | 0.001 | 0.33 µL | 0.00025 ml | 0.31" | 0.03" | 3 11/16" | Borosilicate Glass | PTFE Plastic | Yes | Threaded Plunger | 0000000 | 000000 |
0.1 | 0.003 | 1.32 µL | 0.001 ml | 0.31" | 0.06" | 3 5/8" | Borosilicate Glass | PTFE Plastic | Yes | Threaded Plunger | 0000000 | 00000 |
1 | 0.034 | 13.23 µL | 0.01 ml | 0.36" | 0.18" | 3 13/16" | Borosilicate Glass | PTFE Plastic | Yes | Threaded Plunger | 0000000 | 000000 |
2.5 | 0.085 | 37.79 µL | 0.025 ml | 0.38" | 0.29" | 3 13/16" | Borosilicate Glass | PTFE Plastic | Yes | Threaded Plunger | 0000000 | 00000 |
Syringe Filters
Filter out contaminants when drawing in and dispensing from syringes with a luer lock connection.
PES filters are the easiest to push samples through. They have strong, tight fibers that won't get clogged or break as easily as standard filters. Use them with large volumes and samples with plenty of debris.
PTFE filters have better chemical resistance than nylon filters.
Glass filters are often used before plastic filters to capture larger particles.
For technical drawings and 3-D models, click on a part number.
Housing | ||||||
---|---|---|---|---|---|---|
Removes Particle Size Down To, microns | Dia. | Material | Color | Connection Type | Each | |
Nylon Plastic | ||||||
0.22 | 1" | Polypropylene Plastic | Semi-Clear White | Luer Lock × Luer Slip | 00000000 | 00000 |
0.45 | 1" | Polypropylene Plastic | Semi-Clear White | Luer Lock × Luer Slip | 00000000 | 0000 |
PES Plastic | ||||||
0.22 | 1" | Polypropylene Plastic | Semi-Clear White | Luer Lock × Luer Slip | 00000000 | 0000 |
0.45 | 1" | Polypropylene Plastic | Semi-Clear White | Luer Lock × Luer Slip | 00000000 | 0000 |
PTFE Plastic | ||||||
0.22 | 1" | Polypropylene Plastic | Semi-Clear White | Luer Lock × Luer Slip | 00000000 | 0000 |
0.45 | 1" | Polypropylene Plastic | Semi-Clear White | Luer Lock × Luer Slip | 00000000 | 0000 |
Borosilicate Glass | ||||||
0.7 | 1" | Polypropylene Plastic | Semi-Clear White | Luer Lock × Luer Slip | 00000000 | 0000 |
1 | 1" | Polypropylene Plastic | Semi-Clear White | Luer Lock × Luer Slip | 00000000 | 0000 |
Housing | |||||||
---|---|---|---|---|---|---|---|
Removes Particle Size Down To, microns | Dia. | Material | Color | Connection Type | Pkg. Qty. | Pkg. | |
Nylon Plastic | |||||||
0.22 | 1" | Polypropylene Plastic | Semi-Clear White | Luer Lock × Luer Slip | 100 | 00000000 | 0000000 |
0.45 | 1" | Polypropylene Plastic | Semi-Clear White | Luer Lock × Luer Slip | 100 | 00000000 | 000000 |
PES Plastic | |||||||
0.22 | 1" | Polypropylene Plastic | Semi-Clear White | Luer Lock × Luer Slip | 10 | 00000000 | 00000 |
0.45 | 1" | Polypropylene Plastic | Semi-Clear White | Luer Lock × Luer Slip | 10 | 00000000 | 00000 |
PTFE Plastic | |||||||
0.22 | 1" | Polypropylene Plastic | Semi-Clear White | Luer Lock × Luer Slip | 100 | 00000000 | 000000 |
0.45 | 1" | Polypropylene Plastic | Semi-Clear White | Luer Lock × Luer Slip | 100 | 00000000 | 000000 |
Borosilicate Glass | |||||||
1 | 1" | Polypropylene Plastic | Semi-Clear White | Luer Lock × Luer Slip | 100 | 00000000 | 000000 |
PTFE-Coated Stainless Steel Dispensing Needles with Luer Lock Connection
Precisely dispense sticky adhesives and liquids. The needle is stainless steel, so it stays rigid during application. It’s coated with slippery PTFE to prevent clogging, even from instant-bonding adhesives. Attach them to syringes that have a luer lock or luer slip connection.
For technical drawings and 3-D models, click on a part number.
Needle | Base | ||||||||
---|---|---|---|---|---|---|---|---|---|
Gauge | Lg. | ID | OD | Material | Material | Color | Pkg. Qty. | Pkg. | |
Straight Needle with Blunt Flat Tip | |||||||||
18 | 1/2" | 0.034" | 0.072" | PTFE-Coated 304 Stainless Steel | Polypropylene Plastic | Dark Gray | 5 | 000000000 | 00000 |
18 | 1" | 0.034" | 0.072" | PTFE-Coated 304 Stainless Steel | Polypropylene Plastic | Dark Gray | 5 | 000000000 | 0000 |
21 | 1/2" | 0.026" | 0.065" | PTFE-Coated 304 Stainless Steel | Polypropylene Plastic | Dark Gray | 5 | 000000000 | 0000 |
21 | 1" | 0.026" | 0.065" | PTFE-Coated 304 Stainless Steel | Polypropylene Plastic | Dark Gray | 5 | 000000000 | 0000 |
25 | 1/2" | 0.011" | 0.050" | PTFE-Coated 304 Stainless Steel | Polypropylene Plastic | Pink | 5 | 000000000 | 0000 |
25 | 1" | 0.011" | 0.050" | PTFE-Coated 304 Stainless Steel | Polypropylene Plastic | Pink | 5 | 000000000 | 0000 |