Any-Direction Constant-Flow-Rate Pumps for Water
Mount these pumps in any position, even upside down. Pumps have a subfractional horsepower motor rated for intermittent use (return to room temperature before restarting). Also known as diaphragm pumps, they are for use in low-flow spraying, draining, and washdown applications. They are self-priming, which means they create a suction force to draw liquid upward. Pumps can run dry and do not require an initial fill, so they’re a good choice for applications without a constant flow of liquid. Do not use with solids.
Battery-operated pumps operate on a 12-volt battery. They are commonly used with agricultural sprayers and washers.
Pumps with a pressure switch automatically shut off the pump at the maximum pressure.
For technical drawings and 3-D models, click on a part number.
Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Flow Rate @ Pressure | Max. ft. of Head | Max. Pressure, psi | Max. Temp., °F | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Max. Self-Priming Ht., ft. | Lg. | Wd. | Ht. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection and With Pressure Switch | ||||||||||||||||||
Hardwire | ||||||||||||||||||
A | 1.5 | 1.24 gpm @ 20 psi (46 ft. of head), 1.04 gpm @ 60 psi (138 ft. of head) | 346 | 150 | 170° | 1 | 3/8 | NPT | Female | 3/8 | NPT | Female | 8 | 9 3/8" | 3 3/8" | 4 1/8" | 0000000 | 0000000 |
Plug | ||||||||||||||||||
A | 1.4 | 1.15 gpm @ 20 psi (46 ft. of head), 0.84 gpm @ 60 psi (138 ft. of head) | 138 | 60 | 130° | 0.57 | 3/8 | NPT | Female | 3/8 | NPT | Female | 8 | 7 5/8" | 3 3/8" | 4 1/4" | 0000000 | 000000 |
A | 1.6 | 1.32 gpm @ 20 psi (46 ft. of head), 1.07 gpm @ 60 psi (138 ft. of head) | 231 | 100 | 170° | 0.95 | 3/8 | NPT | Female | 3/8 | NPT | Female | 8 | 8 5/8" | 3 3/8" | 4" | 0000000 | 000000 |
A | 1.7 | 1.52 gpm @ 20 psi (46 ft. of head), 0.03 gpm @ 60 psi (138 ft. of head) | 138 | 60 | 170° | 0.61 | 3/8 | NPT | Female | 3/8 | NPT | Female | 8 | 8 5/8" | 3 3/8" | 4" | 0000000 | 000000 |
A | 3 | 2.20 gpm @ 20 psi (46 ft. of head) | 104 | 45 | 120° | 0.7 | 1/2 | NPSM | Male | 1/2 | NPSM | Male | 8 | 8 3/4" | 5" | 4 1/2" | 0000000 | 000000 |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Plug | ||||||||||||||||||
A | 3.4 | 2.30 gpm @ 20 psi (46 ft. of head) | 92 | 40 | 120° | 1 | 1/2 | NPSM | Male | 1/2 | NPSM | Male | 8 | 7 5/8" | 5" | 4 3/8" | 0000000 | 000000 |
12V DC—With Thermal Overload Protection and With Pressure Switch | ||||||||||||||||||
Hardwire | ||||||||||||||||||
B | 5.3 | 4.30 gpm @ 20 psi (46 ft. of head), 3.40 gpm @ 60 psi (138 ft. of head) | 120 | 60 | 140° | 17 | 1/2 | NPSM | Male | 1/2 | NPSM | Male | 8 | 10" | 4 15/16" | 4" | 0000000 | 000000 |
12V DC—Without Thermal Overload Protection and With Pressure Switch | ||||||||||||||||||
Hardwire | ||||||||||||||||||
A | 1.8 | 1.45 gpm @ 20 psi (46 ft. of head), 1.22 gpm @ 60 psi (138 ft. of head) | 231 | 100 | 170° | 8.7 | 3/8 | NPT | Female | 3/8 | NPT | Female | 10 | 8 3/8" | 4" | 4 1/8" | 0000000 | 000000 |
A | 1.8 | 1.57 gpm @ 20 psi (46 ft. of head), 1.23 gpm @ 60 psi (138 ft. of head) | 138 | 60 | 170° | 7.2 | 3/8 | NPT | Female | 3/8 | NPT | Female | 12 | 8 3/8" | 4" | 4 1/8" | 0000000 | 000000 |
A | 3 | 2.69 gpm @ 20 psi (46 ft. of head) | 115 | 50 | 170° | 8 | 1/2 | NPSM | Male | 1/2 | NPSM | Male | 8 | 8 5/8" | 5" | 4 1/2" | 0000000 | 000000 |
A | 3.5 | 2.56 gpm @ 20 psi (46 ft. of head) | 115 | 50 | 130° | 9.9 | 1/2 | NPSM | Male | 1/2 | NPSM | Male | 9 | 8 5/8" | 5" | 4 1/2" | 0000000 | 000000 |
Continuous-Duty Any-Direction Constant-Flow-Rate Pumps for Water and Coolants
Rated for continuous use, this pump is often used to move caustics such as antifreeze and salt water. Mount it in any position, even upside down. Also known as a diaphragm pump, it is typically used for low-flow spraying, draining, and washdown applications. Pump has a pressure switch that automatically shuts off the pump at the maximum pressure. It is self-priming, which means it creates a suction force to draw liquid upward. Pump can run dry and does not require an initial fill, so it’s a good choice for applications without a constant flow of liquid. Do not use with solids.
Intake | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Flow Rate @ Pressure | Max. Pressure, psi | Max. Viscosity, cP | Max. Temp. Range, °F | hp | Current, A | Tube Connection Type | Gender | For Tube ID | Tube Connection Type | Gender | For Tube ID | Lg. | Wd. | Ht. | Each | |
120V AC, Single Phase—With Thermal Overload Protection and Pressure Switch | |||||||||||||||||
Plug | |||||||||||||||||
3 | 2.50 gpm @ 20 psi (46 ft. of head) | 40 | 250 | 130° | 3/16 | 1.8 | Barbed | Male | 1/2" | Barbed | Male | 1/2" | 10 7/8" | 5 3/8" | 5 5/8" | 0000000 | 0000000 |
Compact Constant-Flow-Rate Pumps for Water and Oil
Designed to fit into small equipment, these pumps have miniature gears and a subfractional horsepower motor for low-flow applications. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Intake | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | hp | Current, A | Tube Connection Type | Gender | For Tube ID | Tube Connection Type | Gender | For Tube ID | Lg. | Wd. | Ht. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
0.43 gpm (55 oz./min.) | 20 | 800 | 10° to 180° | Subfractional | 1.5 | Barbed | Male | 3/16" | Barbed | Male | 3/16" | 4 3/8" | 3" | 3 3/4" | 0000000 | 0000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
0.43 gpm (55 oz./min.) | 20 | 800 | 10° to 180° | Subfractional | 1.5 | Barbed | Male | 3/16" | Barbed | Male | 3/16" | 4 3/8" | 3" | 3 3/4" | 0000000 | 000000 |
Harsh-Environment Compact Constant-Flow-Rate Pumps for Water and Oil
An aluminum enclosure around the motor provides protection in dusty and dirty environments. Designed to fit into small equipment, these pumps have miniature gears and a subfractional horsepower motor for low-flow applications. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Intake | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | hp | Current, A | Tube Connection Type | Gender | For Tube ID | Tube Connection Type | Gender | For Tube ID | Lg. | Wd. | Ht. | Each | |
12V DC—Without Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
0.61 gpm (78 oz./min.) | 20 | 800 | 10° to 180° | Subfractional | 2.2 | Barbed | Male | 3/16" | Barbed | Male | 3/16" | 4" | 1 3/4" | 2 1/2" | 0000000 | 000000 |
24V DC—Without Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
0.61 gpm (78 oz./min.) | 20 | 800 | 10° to 180° | Subfractional | 1.4 | Barbed | Male | 3/16" | Barbed | Male | 3/16" | 4" | 1 3/4" | 2 1/2" | 0000000 | 000000 |
High-Pressure Constant-Flow-Rate Pumps
Commonly called rotary vane pumps, these are designed to pump water at high pressures in low-flow applications. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. They have a built-in bypass relief valve to prevent pressure buildup. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Intake | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Pressure, psi | Max. Viscosity | Temp. Range, °F | hp | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Lg. | Wd. | Ht. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
0.8 | 240 | Not Rated | 30° to 195° | 1/4 | 5 | 3/8 | NPT | Female | 3/8 | NPT | Female | 12" | 6" | 6" | 00000000 | 0000000 |
120/240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
1.8 | 240 | Not Rated | 30° to 195° | 1/3 | 5.6/2.8 | 3/8 | NPT | Female | 3/8 | NPT | Female | 12" | 6" | 6" | 00000000 | 000000 |
2.3 | 240 | Not Rated | 30° to 195° | 1/2 | 7.2/3.6 | 3/8 | NPT | Female | 3/8 | NPT | Female | 12" | 6" | 6" | 00000000 | 000000 |
Submersible Pumps for Water
Submerge these pumps to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Hardwire pumps must be wired to a plug (not included).
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
A | Plug | 2.8 | 1.7 | __ | 7 | 35° to 120° | 1/125 hp | 0.6 | Screened | 1/4 | NPT | Male | 6 | 3 5/8" | 2 7/8" | 3 1/2" | 0000000 | 0000000 |
A | Plug | 5 | 4 | 2.2 | 12.2 | 35° to 120° | 1/40 hp | 0.8 | Screened | 1/4 | NPT | Male | 6 | 4 1/4" | 2 7/8" | 4 7/8" | 0000000 | 000000 |
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
115V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
B | Plug | 5.6 | 4.3 | 0.8 | 11.1 | 35° to 85° | 1/15 hp | 0.8 | Screened | 1/4 | NPT | Male | 6 | 4" | 3 7/8" | 5 3/8" | 0000000 | 000000 |
B | Plug | 8.9 | 6.9 | 2.5 | 13 | 35° to 85° | 1/10 hp | 1.2 | Screened | 1/2 | NPT | Male | 6 | 4 1/2" | 4" | 5 5/8" | 0000000 | 00000 |
115V AC, Single Phase—Without Thermal Overload Protection | ||||||||||||||||||
B | Plug | 3.5 | 1.5 | __ | 7.1 | 35° to 85° | 1/25 hp | 0.5 | Screened | 1/4 | NPT | Male | 6 | 3 7/8" | 3 1/2" | 4 5/8" | 0000000 | 00000 |
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
C | Plug | 3.5 | 2.5 | __ | 10.2 | 35° to 120° | 1/150 hp | 1.1 | Screened | 1/4 | NPT | Male | 6 | 4 5/8" | 4 1/8" | 4 1/8" | 0000000 | 0000000 |
C | Plug | 5.4 | 4.5 | 2.2 | 12.3 | 35° to 120° | 1/40 hp | 1.7 | Screened | 1/4 | NPT | Male | 6 | 4 5/8" | 5" | 5" | 0000000 | 000000 |
C | Plug | 5.4 | 4.5 | 2.2 | 12.3 | 35° to 120° | 1/40 hp | 1.7 | Screened | 1/4 | NPT | Male | 18 | 4 5/8" | 5" | 5" | 0000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
C | Hardwire | 5.4 | 4.5 | 2.2 | 12.3 | 35° to 120° | 1/40 hp | 0.7 | Screened | 1/4 | NPT | Male | 12 | 4 5/8" | 5" | 5" | 0000000 | 000000 |
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
D | Plug | 7.9 | 6.6 | 3.4 | 13.4 | 35° to 120° | 1/28 hp | 1.4 | Screened | 3/8 | NPT | Male | 6 | 4" | 4" | 4 5/8" | 0000000 | 0000000 |
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
115V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
E | Plug | 20 | 12 | 4 | 15 | 35° to 85° | 1/15 hp | 1 | Screened | 3/4 | NPT | Male | 15 | 5 1/4" | 3 3/4" | 6 3/8" | 00000000 | 0000000 |
Submersible/Open-Air Pumps for Water
These pumps can be submerged or connected remotely to a pipe in your line. Use them to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Max. Flow Rate, gpm | Intake | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Plug | ||||||||||||||||
2.8 | 1.7 | 7 | 35° to 120° | 1/125 hp | 0.6 | 1/4 × 1/2 | NPT × NPT | Female × Male | 1/4 | NPT | Male | 3 3/8" | 3 3/4" | 2 3/4" | 0000000 | 0000000 |
Impact-Resistant Submersible Pumps for Water
The durable epoxy-coated aluminum housing handles hard knocks in rough waters. Submerge these pumps to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Hardwire pumps must be wired to a plug (not included).
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Plug | ||||||||||||||||
A | 2.8 | 1.7 | __ | 7 | 35° to 120° | 1/200 hp | 1.1 | Screened | 1/4 | NPT | Male | 4 1/4" | 4 1/8" | 4 1/8" | 0000000 | 0000000 |
B | 5 | 3.4 | 1.2 | 11.8 | 35° to 120° | 1/40 hp | 1.7 | Screened | 1/4 | NPT | Male | 4 3/4" | 3 1/2" | 5 1/2" | 000000 | 000000 |
B | 13.5 | 12.4 | 10.2 | 24.5 | 35° to 120° | 1/12 hp | 3.5 | Screened | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | 000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
A | 3.4 | 2 | __ | 7.4 | 35° to 120° | 1/150 hp | 0.4 | Screened | 1/4 | NPT | Male | 4 1/4" | 4 1/8" | 4 1/8" | 0000000 | 000000 |
B | 13.5 | 12.4 | 10.2 | 24.5 | 35° to 120° | 1/12 hp | 1.6 | Screened | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | 0000000 | 000000 |
Extended-Life Submersible/Open-Air Pumps for Water
These pumps can be submerged or connected remotely to a pipe in your line. Magnets turn the impeller so there's no shaft seal to wear out. Use to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 0 Ft. of Head | @ 1 Ft. of Head | @ 3 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Tube Connection Type | For Tube ID | Tube Connection Type | For Tube ID | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||
Plug | 2.3 | 2 | 1.5 | 4.6 | 3" | 35° to 160° | 1/200 hp | 0.5 | Barbed | 3/8" | Barbed | 3/8" | 3 1/4" | 3 3/4" | 4 1/2" | 0000000 | 0000000 |
Plug | 3 | 2.6 | 1.8 | 4.6 | 3" | 35° to 160° | 1/200 hp | 0.5 | Barbed | 1/2" | Barbed | 1/2" | 3 1/4" | 3 3/4" | 4 1/2" | 0000000 | 000000 |
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 0 Ft. of Head | @ 1 Ft. of Head | @ 3 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||||
Plug | 3 | 2.6 | 1.8 | 4.6 | 3" | 35° to 160° | 1/200 hp | 0.5 | 1/4 | NPT | Male | 1/4 | NPT | Male | 3 1/4" | 3 3/4" | 4 1/2" | 0000000 | 0000000 |
Impact-Resistant Submersible/Open-Air Pumps for Water
Protected from impact by a durable epoxy-coated aluminum housing, these pumps can be submerged or connected remotely to a pipe in your line. Use to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Hardwire pumps must be wired to a plug (not included).
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Features | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug | |||||||||||||||||||
A | 3.4 | 2 | __ | 7.4 | 35° to 120° | 1/150 hp | 1.1 | 1/4 × 1/2 | NPT × NPT | Female × Male | 1/4 | NPT | Male | 4 1/8" | 4 1/8" | 4 5/8" | __ | 0000000 | 0000000 |
B | 5 | 3.4 | 1.2 | 11.8 | 35° to 120° | 1/40 hp | 1.7 | 3/8 | NPT | Female | 1/4 | NPT | Male | 4 3/4" | 3 1/2" | 5 1/2" | Removable Intake Screen | 000000 | 000000 |
B | 8.3 | 5.6 | 3.5 | 17.3 | 35° to 120° | 1/15 hp | 3.2 | 1/2 | NPT | Female | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | Removable Intake Screen | 000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
B | 5 | 3.4 | 1.2 | 11.8 | 35° to 120° | 1/40 hp | 0.7 | 3/8 | NPT | Female | 1/4 | NPT | Male | 4 3/4" | 3 1/2" | 5 1/2" | Removable Intake Screen | 0000000 | 000000 |
B | 10 | 8.6 | 6.9 | 21 | 35° to 120° | 1/15 hp | 1.4 | 1/2 | NPT | Female | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | Removable Intake Screen | 0000000 | 000000 |
Extended-Life Submersible Pumps for Water
Magnets turn the impeller so there's no shaft seal to wear out. Submerge these pumps to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry.
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 0 Ft. of Head | @ 1 Ft. of Head | @ 3 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | ||||||||||||||||
Plug | ||||||||||||||||
3 | 2.6 | 1.8 | 4.6 | 3" | 35° to 160° | 1/200 hp | 0.5 | Screened | 1/4 | NPT | Male | 3 1/4" | 3 3/4" | 3 7/8" | 0000000 | 0000000 |
Precise-Flow Electric Drum Pumps for Water, Oil, and Chemicals
For accurate dispensing in extremely low-flow applications, adjust flow in 2% increments. These pumps are compatible with chemicals such as ammonia and etching and cleaning solutions.
Temp. Range, °F | Intake | Discharge | Pumps | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Each | |
120V AC, Single Phase | ||||||||||||||||
Plug | ||||||||||||||||
0.001-0.01 | 100 | 30 | 1,500 | 35° | 125° | 1/30 hp | 1.7 | 2" | Tube Nut Connector | 3/8" | 20ft. | 1/4" | 1/4" | 20ft. | 0000000 | 0000000 |
0.001-0.1 | 100 | 30 | 1,500 | 35° | 100° | 1/16 hp | 0.6 | 2" | Drum Connector | 3/8" | 20ft. | 1/4" | 1/4" | 20ft. | 0000000 | 00000000 |
Miniature Low-Flow Air Compressors/Vacuum Generators
These air compressors/vacuum generators are continuous duty and must be hardwired. They do not require lubricant and produce nonlubricated air.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Pressure, psi | Max. Flow Rate @ psi | Vacuum Rating, in. of Hg | Full Load Current | Vol., dBA | Lg. | Wd. | Ht. | For Tube ID | Lubricant Required | Electrical Connection Type | Each | |
12V DC | ||||||||||||
3 | 0.019 cfm @ 3 0.042 cfm @ 0 | 12 | 40 mA | 45 | 1 3/4" | 15/16" | 1 5/16" | 0.14" | No | Hardwire | 0000000 | 0000000 |
10 | 0.064 cfm @ 10 0.117 cfm @ 0 | 22 | 442 mA | 45 | 3 1/16" | 1 3/16" | 2 3/16" | 0.16" | No | Hardwire | 0000000 | 000000 |
12 | 0.148 cfm @ 12 0.254 cfm @ 0 | 25 | 2.3 A | 52 | 4 7/8" | 1 7/8" | 3 1/16" | 0.13" | No | Hardwire | 0000000 | 000000 |
3.5-7V DC | ||||||||||||
2 | 0.008 cfm @ 2 0.013 cfm @ 0 | 12 | 32-37 mA | 45 | 1 5/8" | 11/16" | 1" | 0.12" | No | Hardwire | 0000000 | 000000 |