No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Position Designation | Switching Current @ Voltage | Max. Voltage | Bulb Voltage | Quick-Disconnect Tab Wd. | Bulb Type | Choose a Color | Each | |
2 Position with Quick-Disconnect Terminals—Illuminated | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For 1 7/32" Ht.×7/16" Wd. Panel Cutout | |||||||||||||
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 3 | SPST-NO | On-Off | 20 A @ 125 V AC | 125V AC | 125V AC | 0.25" | Neon | 0000000 | 00000 | |
For 1 7/32" Ht.×7/8" Wd. Panel Cutout | |||||||||||||
2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | On-Off | 20 A @ 125 V AC | 125V AC | 125V AC | 0.25" | Neon | 0000000 | 00000 |
Design-Your-Own Rocker Switches
Choose from a variety of messages and colored lenses to combine a rocker with a base for a complete switch.
Bases with an on-on position designation alternate power between sets of terminals.
Note: Illuminated switches include a bulb. If wiring the switch and the bulb to the same circuit, the circuit voltage must not exceed bulb voltage.
For technical drawings and 3-D models, click on a part number.
No. of Positions | Position Illuminated | No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Position Designation | Color | Switching Current @ Voltage | Max. Voltage | Bulb Voltage | Quick-Disconnect Tab Wd. | Each | |
2 | Top | 1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 4 | SPST-NO | On-Off | Black | 15 A @ 125 V AC, 15 A @ 28 V DC | 30V DC 250V AC | 14V DC | 0.25" | 0000000 | 000000 |
2 | Top | 2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 6 | DPST-NO | On-Off | Black | 15 A @ 125 V AC, 15 A @ 28 V DC | 30V DC 250V AC | 14V DC | 0.25" | 0000000 | 00000 |
2 | Top/Bottom | 1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 6 | SPST-NO | On-Off | Black | 15 A @ 125 V AC, 15 A @ 28 V DC | 30V DC 250V AC | 14V DC | 0.25" | 0000000 | 00000 |
2 | Top/Bottom | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 7 | SPDT | On-On | Black | 15 A @ 125 V AC, 15 A @ 28 V DC | 30V DC 250V AC | 14V DC | 0.25" | 0000000 | 00000 |
2 | Top/Bottom | 2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 8 | DPST-NO | On-Off | Black | 15 A @ 125 V AC, 15 A @ 28 V DC | 30V DC 250V AC | 14V DC | 0.25" | 0000000 | 00000 |
2 | Top/Bottom | 2 | 2 Off (Normally Open) or 2 On (Normally Closed) | Stays Switched (Maintained) | 10 | DPDT | On-On | Black | 15 A @ 125 V AC, 15 A @ 28 V DC | 30V DC 250V AC | 14V DC | 0.25" | 0000000 | 00000 |
3 | Top/Bottom | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 7 | SPDT | On-Off-On | Black | 15 A @ 125 V AC, 15 A @ 28 V DC | 30V DC 250V AC | 14V DC | 0.25" | 0000000 | 00000 |
3 | Top/Bottom | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Springs Back (Momentary) | 7 | SPDT | (On)-Off-(On) | Black | 15 A @ 125 V AC, 15 A @ 28 V DC | 30V DC 250V AC | 14V DC | 0.25" | 0000000 | 00000 |
3 | Top/Bottom | 2 | 2 Off (Normally Open) or 2 On (Normally Closed) | Stays Switched (Maintained) | 10 | DPDT | On-Off-On | Black | 15 A @ 125 V AC, 15 A @ 28 V DC | 30V DC 250V AC | 14V DC | 0.25" | 0000000 | 00000 |
3 | Top/Bottom | 2 | 2 Off (Normally Open) or 2 On (Normally Closed) | Springs Back (Momentary) | 10 | DPDT | (On)-Off-(On) | Black | 15 A @ 125 V AC, 15 A @ 28 V DC | 30V DC 250V AC | 14V DC | 0.25" | 0000000 | 00000 |
Miniature Rocker Switches
Maximize space in a panel—these switches are smaller than most standard rocker switches.
Note: Illuminated switches include a bulb. If wiring the switch and the bulb to the same circuit, the circuit voltage must not exceed bulb voltage.
For technical drawings and 3-D models, click on a part number.
Wire Leads | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Position Designation | Switching Current @ Voltage | Max. Voltage | Bulb Voltage | No. of | Lg. | Quick-Disconnect Tab Wd. | Bulb Type | Choose a Color | Each | |
2 Position with Quick-Disconnect Terminals—Illuminated | |||||||||||||||
For 3/4" Ht.×1/2" Wd. Panel Cutout | |||||||||||||||
2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | On-Off | 9 A @ 125 V AC | 125V AC | 125V AC | __ | __ | 0.187" | Neon | 0000000 | 000000 | |
2 Position with Wire Leads—Illuminated | |||||||||||||||
For 3/4" Ht.×1/2" Wd. Panel Cutout | |||||||||||||||
2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | On-Off | 9 A @ 125 V AC | 125V AC | 125V AC | 4 | 12" | __ | Neon | Green | 00000000 | 00000 |
2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | On-Off | 9 A @ 125 V AC | 125V AC | 125V AC | 4 | 12" | __ | Neon | Red | 00000000 | 00000 |
2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | On-Off | 9 A @ 125 V AC | 125V AC | 125V AC | 4 | 12" | __ | Neon | Yellow | 00000000 | 00000 |
Rocker Light Switches
Similar to a seesaw, these switches have an actuator that pivots when pressed to turn them on or off. They’re often used to control lighting, but they also work with AC motor loads up to 80% of the current rating. All fit standard wall plates (not included) and won’t stick out from your wall as much as toggle light switches.
Switches with spring-clamp terminals are quicker to install than those with screw terminals. Just push your bare wires into the connectors.
Illuminated switches glow when turned off, making them easy to spot in the dark.
Wall switch lockouts (sold separately) mount over switches to secure them in the on or off position.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | No. of Terminals | Switch Action | Switching Current @ Voltage | Terminal Location | Specifications Met | Choose a Color | Each | |
WIth Screw Terminals | ||||||||
---|---|---|---|---|---|---|---|---|
Illuminated | ||||||||
1 | 2 | Stays Switched (Maintained) | 15 A @ 120 V AC | Side | UL Listed, C-UL Listed | 0000000 | 000000 | |
With Spring-Clamp Terminals | ||||||||
Illuminated | ||||||||
1 | 2 | Stays Switched (Maintained) | 20 A @ 120 V AC/277 V AC | Back | UL Listed, C-UL Listed, CSA Certified | 0000000 | 00000 |
Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Max. No. of Padlocks | For Max. Padlock Shackle Dia. | Lg. | Wd. | Dp. | Color | Language | Message | Specifications Met | Each | |
1 | 9/32" | 4 3/4" | 1 3/4" | 1" | Red | English/Spanish, English/French | Danger—Locked Out Do Not Remove, Peligro—Cerrado No Lo Quite, Danger—Locked Out Do Not Remove, Danger—Verrouille Ne Pas Enlever | OSHA Compliant 29 CFR 1910.147 | 00000000 | 000000 |
Multi-Way Rocker Light Switches
Also known as three-way switches, these are often used in large, open workspaces and can be wired on opposite ends of the room to control lights on the same circuit. They work in pairs to control lights from two different locations. Actuate the switch by pressing on the wide, flat area. With a slim, low-profile design, they protrude less than toggle switches. All fit standard wall plates (not included).
Switches with spring-clamp terminals install quickly to create a secure connection. Just push a stripped wire into the clamp—no need to bend wire and screw it down.
Wall switch lockouts (sold separately) mount over switches to secure them in the on or off position.
Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Max. No. of Padlocks | For Max. Padlock Shackle Dia. | Lg. | Wd. | Dp. | Color | Language | Message | Specifications Met | Each | |
1 | 9/32" | 4 3/4" | 1 3/4" | 1" | Red | English/Spanish, English/French | Danger—Locked Out Do Not Remove, Peligro—Cerrado No Lo Quite, Danger—Locked Out Do Not Remove, Danger—Verrouille Ne Pas Enlever | OSHA Compliant 29 CFR 1910.147 | 00000000 | 000000 |