About Door Closers
When replacing an existing closer, remove the cover and match the model number and/or mounting hole pattern to a closer in our offering. Or, use one of our closers and a universal mounting plate that matches most hole patterns.
If you are installing a new closer, choose one that works for your door width. Due to added resistance from wind, closers typically accommodate smaller exterior doors than interior doors.
There are three typical mounting positions for door closers; many of our closers are versatile and can be mounted in any of these positions. To determine opening direction, stand on the side of the door where the closer will be mounted. If the door opens towards you it opens in; opens away from you it opens out.
Door Mount, Opens In—Also known as regular arm mount, this position allows the door to open in toward the closer.
Door Mount, Opens Out—Also known as parallel arm mount, the arm lays parallel with the door in the closed position.
Frame Mount, Opens Out—Also known as top frame mount, this position is often used for exterior doors.
High-Traffic Door Closers
For frequently used doors, these closers last twice as long as standard door closers. They can replace Yale, Dorma, Falcon, Stanley, Parker, and Cal-Royal models with the same mounting hole pattern. All meet ANSI A156.4 Grade 1 durability, strength, and performance standards for door controls. Closers that meet UL 10C for fire-rated doors meet positive pressure fire test standards.
To determine door swing direction, stand on the side of the door where it swings away from you. If it opens to the right, select a right closer; if it opens to the left, select a left closer. Reversible closers are for right or left door-swing directions.
Free-moving closers pull doors shut after you've opened them.
Hold-open closers hold doors open until you close them with a slight push or pull on the door.
For Door Wd. | Opening Direction | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Interior | Exterior | For Door Swing Direction | Opening/Closing Action | Door Mount | Frame Mount | Range of Motion | Mounting Hardware Included | Specifications Met | Choose a Finish | Each | |
LCN 4040XP | |||||||||||
24"-60" | 24"-48" | Reversible | Free Moving | Opens In, Opens Out | Opens Out | 120° | Yes | ANSI A156.4 Grade 1 UL 10C UL Listed | 0000000 | 0000000 | |
24"-60" | 24"-48" | Reversible | Hold Open | Opens In, Opens Out | Opens Out | 120° | Yes | ANSI A156.4 Grade 1 | 0000000 | 000000 |
High-Traffic Door Closers with Built-In Stop
A built-in stop prevents doors from opening too far—good when wall- or floor-stops can’t be used. Designed for frequently used doors, these closers last twice as long as standard door closers. They can replace Yale, Dorma, Falcon, Stanley, Parker, and Cal-Royal models with the same mounting hole pattern. These closers are reversible for right or left door-swing directions. All meet ANSI A156.4 Grade 1 durability, strength, and performance standards for door controls. Closers that meet UL 10C for fire-rated doors meet positive pressure fire test standards.
Free-moving closers pull doors shut after you've opened them.
Hold-open closers hold doors open until you close them with a slight push or pull on the door.
For Door Wd. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Interior | Exterior | For Door Swing Direction | Opening/Closing Action | Door Mount Opening Direction | Range of Motion | Mounting Hardware Included | Specifications Met | Choose a Finish | Each | |
LCN 4040XP | ||||||||||
24"-60" | 24"-48" | Reversible | Free Moving | Opens Out | 110° | Yes | ANSI A156.4 Grade 1 UL 10C UL Listed | 0000000 | 0000000 | |
24"-60" | 24"-48" | Reversible | Hold Open | Opens Out | 110° | Yes | ANSI A156.4 Grade 1 | 0000000 | 000000 |
Replacement Arms for Door Closers
Save time and money by replacing worn or damaged arms instead of the entire closer. These arms are reversible for right or left door-swing directions. All meet ANSI A156.4 Grade 1 durability, strength, and performance standards for door controls. They also meet UL 10C for fire-rated doors, which meet positive pressure fire test standards.
Use free-moving arms with free-moving closers that pull doors shut after you've opened them. Arms with a built-in stop prevent doors from opening too far.
Use hold-open arms with hold-open closers, which hold doors open until you close them with a slight push or pull on the door.
For Door Wd. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Interior | Exterior | For Door Swing Direction | Opening/Closing Action | Range of Motion | Mounting Hardware Included | Specifications Met | Features | Finish | Each | |
LCN 4040XP | ||||||||||
24"-60" | 24"-48" | Reversible | Free Moving | 120° | Yes | ANSI A156.4 Grade 1 UL 10C UL Listed | Built-In Stop | Gray | 0000000 | 0000000 |
24"-60" | 24"-48" | Reversible | Hold Open | 120° | Yes | ANSI A156.4 Grade 1 UL 10C UL Listed | __ | Gray | 0000000 | 000000 |