Ovens
Also known as gravity convection and laboratory ovens, heat rises from the base into the oven chamber and out through the top vents. Use these general purpose ovens for heating and curing up to 437° F. The control components are CSA certified and UL recognized.
NEMA 5-15 | |
NEMA 6-15 |
Inside | Overall | Shelf | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., cu. ft. | Temp. Setting (Accuracy) | Ht. | Wd. | Dp. | Ht. | Wd. | Dp. | No. of Shelves | Cap., lbs. | Type | Material | Insulation Material | Wattage, W | Current, A | Plug Type | NEMA Style | Each | |
120V AC—Single Phase | ||||||||||||||||||
0.7 | 93° to 437° F (±6° F) 34° to 225° C (±3° C) | 10" | 12" | 10" | 17" | 14" | 12" | 2 | 35 | Adjustable | Steel | Mineral Wool | 600 | 5 | Three Prong | 5-15 | 0000000 | 0000000 |
1.3 | 93° to 437° F (±6° F) 34° to 225° C (±3° C) | 13" | 13" | 13" | 21" | 15" | 15" | 2 | 35 | Adjustable | Steel | Mineral Wool | 750 | 6 | Three Prong | 5-15 | 0000000 | 000000 |
2 | 93° to 437° F (±6° F) 34° to 225° C (±3° C) | 16" | 18" | 12" | 25" | 20" | 14" | 2 | 35 | Adjustable | Steel | Mineral Wool | 1,200 | 11 | Three Prong | 5-15 | 0000000 | 000000 |
3 | 93° to 437° F (±6° F) 34° to 225° C (±3° C) | 21" | 18" | 14" | 30" | 20" | 16" | 2 | 35 | Adjustable | Steel | Mineral Wool | 1,500 | 13 | Three Prong | 5-15 | 0000000 | 00000000 |
240V AC—Single Phase | ||||||||||||||||||
2 | 93° to 437° F (±6° F) 34° to 225° C (±3° C) | 16" | 18" | 12" | 25" | 20" | 14" | 2 | 35 | Adjustable | Steel | Mineral Wool | 1,200 | 11 | Three Prong | 6-15 | 0000000 | 000000 |
3 | 93° to 437° F (±6° F) 34° to 225° C (±3° C) | 21" | 18" | 14" | 30" | 20" | 16" | 2 | 35 | Adjustable | Steel | Mineral Wool | 1,600 | 13 | Three Prong | 6-15 | 0000000 | 00000000 |
Replacement Shelf for 0.7 cu. ft. Cap. Oven | 0000000 | Each | 000000 |
Replacement Shelf Support for All Ovens | 0000000 | Each | 0000 |
Replacement Thermostat for 0.7 cu. ft. Cap. Oven | 000000 | Each | 00000 |
Replacement Shelf Support for 0.7 cu. ft., 1.3 cu. ft., 2 cu. ft., 3 cu. ft. Cap. Oven | 0000000 | Each | 0000 |
Replacement Thermometer for All Ovens | 000000 | Each | 00000 |
Replacement Thermostat for 1.3 cu. ft., 2 cu. ft., 3 cu. ft. Cap. Oven | 000000 | Each | 000000 |
Replacement Shelf for 2 cu. ft. Cap. Oven | 0000000 | Each | 00000 |
Replacement Shelf for 1.3 cu. ft. Cap. Oven | 0000000 | Each | 00000 |
Replacement Shelf for 3 cu. ft. Cap. Oven | 0000000 | Each | 00000 |
Forced-Air Ovens
These mechanical convection ovens have a blower to circulate air for more consistent heating throughout than gravity-style ovens. They heat and cure up to 550° F.
Inside | Overall | Shelf | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., cu. ft. | Temp. Setting, °F (Accuracy) | Ht. | Wd. | Dp. | Ht. | Wd. | Dp. | No. of Shelves | Cap., lbs. | Type | Material | Wattage, W | Current, A | Electrical Connection Type | NEMA Style | Features | Each | |
Ovens—120V AC (Single Phase) | ||||||||||||||||||
5.3 | 120° to 550° (±10° F) | 16" | 26" | 22" | 23" | 41" | 30" | 2 | 20 | Adjustable | Stainless Steel | 2,400 | 23 | Plug | 5-30 | On/Off Indicator Light | 0000000 | 000000000 |
7 | 120° to 350° (±10° F) | 18" | 28" | 24" | 23" | 41" | 30" | 2 | 20 | Adjustable | Stainless Steel | 2,000 | 20 | Plug | 5-20 | On/Off Indicator Light | 0000000 | 00000000 |
7 | 120° to 350° (±10° F) | 18" | 28" | 24" | 23" | 41" | 30" | 2 | 20 | Adjustable | Stainless Steel | 2,000 | 20 | Plug | 5-20 | On/Off Indicator Light, 12-hr. Timer | 0000000 | 00000000 |
Ovens—240V AC (Single Phase) | ||||||||||||||||||
7 | 120° to 350° (±10° F) | 18" | 28" | 24" | 23" | 41" | 30" | 2 | 20 | Adjustable | Stainless Steel | 2,000 | 11 | Hardwire | __ | On/Off Indicator Light | 0000000 | 00000000 |
36 | 120° to 400° (±2° F) | 36" | 36" | 48" | 47" | 40" | 55" | 2 | 50 | Adjustable | Stainless Steel | 6,600 | 33 | Hardwire | __ | On/Off Indicator Light | 0000000 | 000000000 |
High-Temperature Furnaces
Achieve temperatures as high as 1200° C for heat-treating metal.
76 and 128-cu. in. capacity furnaces have an LED that shows actual or set-point temperature in ° C; an indicator light flashes when set temperature is reached. The safety switch shuts off the furnace when the door is opened.
For technical drawings and 3-D models, click on a part number.
Inside | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., cu. in. | Temp. Setting (Accuracy) | Ht. | Wd. | Dp. | Ht. | Wd. | Dp. | Material | Wattage, W | Current, A | Plug Type | NEMA Style | Each | |
550 | 77° to 2,192° F (±9° F) 25° to 1,200° C (±5° C) | 8" | 8" | 9" | 23" | 19" | 25" | Steel | 3,360 | 14 | Three Prong | 6-20 | 0000000 | 000000000 |
Programmable High-Temperature Furnaces
Program time, temperature, and rate of temperature change. These furnaces reach temperatures as high as 2192° F for heat-treating metal. These furnaces have six programmable parameters: 1) delay start, 2) rate of temperature change, 3) target temperature, 4) temperature timer, 5) memory retrieval, and 6) °C/°F digital display. Link two three-stage programs to create a six-stage operation. A maximum of 10 programs can be stored with up to a seven-day delay. An LCD shows internal temperature, countdown time, and program number.
For technical drawings and 3-D models, click on a part number.
Inside | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., cu. in. | Temp. Setting (Accuracy) | Ht. | Wd. | Dp. | Ht. | Wd. | Dp. | Material | Wattage, W | Current, A | Plug Type | NEMA Style | Cord Lg., ft. | Each | |
550 | 77° to 2,192° F (±9° F) 25° to 1,200° C (±5° C) | 8" | 8" | 9" | 23" | 19" | 25" | Steel | 3,360 | 28 | Three Prong | 5-50 | 6 | 0000000 | 000000000 |
Inside | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., cu. in. | Temp. Setting (Accuracy) | Ht. | Wd. | Dp. | Ht. | Wd. | Dp. | Material | Wattage, W | Current, A | Plug Type | NEMA Style | Cord Lg., ft. | Each | |
550 | 77° to 2,192° F (±9° F) 25° to 1,200° C (±5° C) | 8" | 8" | 9" | 23" | 19" | 25" | Steel | 3,360 | 14 | Three Prong | 6-20 | 6 | 0000000 | 000000000 |
1,750 | 77° to 2,192° F (±9° F) 25° to 1,200° C (±5° C) | 12" | 12" | 12" | 28" | 23" | 30" | Steel | 7,333 | 31 | Three Prong | 6-50 | 6 | 0000000 | 00000000 |
Replacement Door Switch for 550 cu. in. and 1,750 cu. in. Cap. Furnace | 000000000 | Each | 000000 |
Replacement Heating Plate for 550 cu. in. Cap. Furnace | 000000000 | Each | 00000000 |
Replacement Control Circuit Board for 550 cu. in. and 1,750 cu. in. Cap. Furnace | 000000000 | Each | 000000 |
Replacement Thermocouple for 550 cu. in. and 1,750 cu. in. Cap. Furnace | 000000000 | Each | 00000 |
Replacement Power Switch for 550 cu. in. and 1,750 cu. in. Cap. Furnace | 000000000 | Each | 00000 |
Replacement Heating Plate for 1,750 cu. in. Cap. Furnace | 000000000 | Each | 00000000 |
Ultraviolet Curing Chambers
Safely cure light-activated adhesives, coatings, and ink or strengthen 3D-printed resin parts with UV light in these enclosed chambers. Also known as flood curing, they evenly cure your parts. They work just like a microwave. Plug them in, set your time, and they’re ready to cure.
Chambers with a turntable are ideal for large and intricate 3D printed parts. The turntable rotates parts under the lights for even exposure while curing. Because these chambers use low-intensity LED bulbs and only operate when the door is closed, additional UV-protective glasses or clothing while using them are not required.
Chambers with a shelf create a deep, consistent cure and work best with small and flat parts. You can position parts closer to the bulb with the adjustable shelf for a faster curing. An automatic lamp shutter covers and reduces power to the bulb when you open the door. You should always wear UV-protective glasses and clothing when the system is turned on because of their high-intensity light. To remotely monitor and control these chambers, connect them to a computer or PLC.
Chambers and replacement bulbs that cannot be sold to Canada are restricted by regulations on limiting mercury content.
For technical drawings and 3-D models, click on a part number.
Inside | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wavelength, nm | Light Intensity | Ht. | Wd. | Dp. | Ht. | Wd. | Dp. | Wattage, W | Cord Lg., ft. | Housing Material | Each | |
405 | Not Rated | 17 3/4" | 15 3/4" | 15 3/4" | 24" | 19" | 17 3/4" | 90 | 5 | Aluminum | 0000000 | 000000000 |
Chambers | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inside | Overall | Replacement Bulbs | |||||||||||||||
Wavelength, nm | Light Intensity | Ht. | Wd. | Dp. | Ht. | Wd. | Dp. | Max. Wattage per Bulb, W | No. of Bulbs Included | Cord Lg., ft. | Housing Material | Includes | Cannot Be Sold To | Each | Each | ||
320-390 | 115 mW/cm² @ 3" | 9" | 9" | 10 1/4" | 19" | 12" | 16" | 400 | 1 | 7 1/2 | Aluminum | UV Protective Glasses | Canada | 0000000 | 000000000 | 0000000 | 0000000 |
Handheld Ultraviolet Disinfectant Lamps
Disinfect phones, door knobs, masks, and other small objects. Using ultraviolet germicidal irradiation (UVGI), these portable lamps kill viruses, bacteria, and other microbes in seconds. Lightweight with a durable plastic housing, they’re designed to be carried from place to place. To guard from UV rays, wear eye protection and cover exposed skin while disinfecting.
These lamps cannot be sold to Canada due to import regulations.
For technical drawings and 3-D models, click on a part number.
Battery-powered lamps let you disinfect where outlets aren’t available. Place them 1" to 2" away from nonporous objects or surfaces and shine for six to eight seconds to fully disinfect. These lamps are small enough to fit in a briefcase or glove compartment. They’re rechargeable and will automatically shut off after five minutes to save battery life.
Overall | Housing | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Light Intensity | Wavelength, nm | Maximum Wattage per Bulb | Bulbs Included | Length | Width | Height | Plug Type | Cord Length, ft. | Batteries Included | Battery Type | Material | Color | Cannot Be Sold To | Each | |
1,000µ W/cm 2 @ 1" | 273 | 6W | Yes | 11 7/8" | 1" | 1" | USB-A | 3 | Yes | Rechargeable | Plastic | White | Canada | 0000000 | 0000000 |
Electric-powered lamps plug into outlets, allowing for uninterrupted disinfecting. An ergonomic handle makes them easy to maneuver and prevents operator fatigue. For hands-free use, mount them on a stand.
Ultraviolet Disinfectant Chambers
These chambers kill viruses, bacteria, and other microbes with ultraviolet germicidal irradiation (UVGI). Use them to disinfect small items, especially those that could be damaged by liquid chemical cleaners. They’re enclosed to protect users, with a UV-blocking window and an auto shut-off function if the door is opened while they’re running. Similar to microwaves, these chambers let you adjust energy and time settings based on what you’re putting inside. Program up to 10 presets to save time when disinfecting with frequently used settings. A built-in radiometer monitors UV levels, making sure the correct level of UVGI energy is delivered even as the bulbs age. Bulbs should be replaced after 5,000 hours of use.
These chambers cannot be sold to Canada due to import regulations.
For technical drawings and 3-D models, click on a part number.
Inside | Overall | Housing | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Light Intensity | Wavelength, nm | Maximum Wattage per Bulb | Number of Bulbs Required | Bulbs Included | Height | Width | Depth | Height | Width | Depth | Plug Type | Cord Length, ft. | Material | Color | Cannot Be Sold To | Each | |
7 mW/cm 2 @ 6" | 254 | 8W | 6 | Yes | 6" | 11" | 14" | 10 1/2" | 16" | 17" | Three Prong | 8 | Aluminum | Black, White | Canada | 0000000 | 000000000 |
Ultraviolet Disinfectant Lamps
Mount these lamps to a ceiling or wall to disinfect lab tools, respirators, and small surfaces such as countertops. These lamps kill viruses, bacteria, and other microbes with ultraviolet germicidal irradiation (UVGI). They’re commonly used in areas that could be damaged by liquid cleaners or chemical disinfectants.
Always wear eye and skin protection when operating. Since these lamps don’t produce ozone, it’s safe to enter the disinfected area as soon as they’re turned off. For best results, replace the bulbs after 1,000 hours of use.
These lamps cannot be sold to Canada due to import regulations.
For technical drawings and 3-D models, click on a part number.
O'all | Mounting Holes | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Light Intensity | Wavelength, nm | Max. Wattage per Bulb | No. of Bulbs Required | Bulbs Included | Lg. | Wd. | Ht. | Cord Lg., ft. | Mounting Hardware Included | No. of | Dia. | Cannot Be Sold To | Each | |
Ceiling and Wall Mount—Stationary | ||||||||||||||
White Aluminum Housing—Three-Prong Plug | ||||||||||||||
2 mW/cm 2 @ 10" | 254 | 40W | 2 | Yes | 49 5/8" | 6" | 4 1/4" | 8 | No | 4 | 1/4" | Canada | 0000000 | 000000000 |
2 mW/cm 2 @ 5" | 254 | 20W | 2 | Yes | 24" | 6" | 4 1/4" | 8 | No | 4 | 1/4" | Canada | 0000000 | 000000 |