ix Industrial Ethernet Switches
Link industrial equipment with multiple computers to expand your data network. Use these switches with ix industrial connectors and cords.
For technical drawings and 3-D models, click on a part number.
Total No. of Sockets | Transmission Speed, Gb/s | Ht. | Wd. | Dp. | Housing Material | Voltage | Fasteners Included (Hole Dia.) | Temp. Range, °F | Wire Connection Type | Number of Terminals | Coding | For Cable Industry Designation | Specifications Met | Each | |
35 mm DIN-Rail Mount | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5 | 1 | 4 15/32" | 2 1/16" | 1" | Aluminum | 24V DC-48V DC | __ | -40° to 155° | Screw Terminals | 3 | A | Category 6A | IEC 61076-3-124 | 0000000 | 0000000 |
8 | 1 | 4 15/32" | 2 1/16" | 1" | Aluminum | 24V DC-48V DC | __ | -40° to 155° | Screw Terminals | 3 | A | Category 6A | IEC 61076-3-124 | 0000000 | 000000 |
Surface Mount | |||||||||||||||
5 | 1 | 4 7/16" | 3 5/32" | 15/16" | Aluminum | 24V DC-48V DC | No (0.157") | -40° to 155° | Screw Terminals | 3 | A | Category 6A | IEC 61076-3-124 | 0000000 | 000000 |
8 | 1 | 4 7/16" | 3 5/32" | 15/16" | Aluminum | 24V DC-48V DC | No (0.157") | -40° to 155° | Screw Terminals | 3 | A | Category 6A | IEC 61076-3-124 | 0000000 | 000000 |
Circuit Board ix Industrial Connectors
Mount ix Industrial
A-Coded Socket
Mount ix Industrial
B-Coded Socket
ix Industrial
A-Coded Socket
ix Industrial
B-Coded Socket
Add ix Industrial connections to printed circuit boards (PCBs). These connectors have a small profile—use them on smaller equipment or to create multiple connection points in a small space. They have metal locking tabs, which are less likely to break off than plastic ones. All are shielded to block interference from nearby devices. These connectors meet Canadian electrical standards and UL data transmission standards. They’re compatible with ix Industrial plugs that meet IEC 61076-3-124.
Choose A-coded connectors as an alternative to RJ45 and M12 Ethernet connectors.
Choose B-coded connectors for signaling applications such as linking a servomotor and encoder. They’re also an alternative to D-sub connectors.
For technical drawings and 3-D models, click on a part number.
Connection Type | Ethernet Connection Type | For Cable Industry Designation | Number of Wires | Housing Material | Environmental Rating | Specifications Met | Each | |
90° Elbow Horizontal Mount ix Industrial A-Coded Socket | ||||||||
---|---|---|---|---|---|---|---|---|
Shielded | ||||||||
Ethernet, ix Industrial | ix Industrial | Category 6A | 8 | Nickel-Plated Stainless Steel | IP20 | CAN/CSA-C22.2 No. 182.3, IEC 61076-3-124, UL 1977 | 0000000 | 00000 |
90° Elbow Horizontal Mount ix Industrial B-Coded Socket | ||||||||
Shielded | ||||||||
ix Industrial | __ | __ | 10 | Nickel-Plated Stainless Steel | IP20 | CAN/CSA-C22.2 No. 182.3, IEC 61076-3-124, UL 1977 | 0000000 | 0000 |
90° Elbow Vertical Mount ix Industrial A-Coded Socket | ||||||||
Shielded | ||||||||
Ethernet, ix Industrial | ix Industrial | Category 6A | 8 | Nickel-Plated Stainless Steel | IP20 | CAN/CSA-C22.2 No. 182.3, IEC 61076-3-124, UL 1977 | 0000000 | 0000 |
90° Elbow Vertical Mount ix Industrial B-Coded Socket | ||||||||
Shielded | ||||||||
ix Industrial | __ | __ | 10 | Nickel-Plated Stainless Steel | IP20 | CAN/CSA-C22.2 No. 182.3, IEC 61076-3-124, UL 1977 | 0000000 | 0000 |
Straight Vertical Mount ix Industrial A-Coded Socket | ||||||||
Shielded | ||||||||
Ethernet, ix Industrial | ix Industrial | Category 6A | 8 | Nickel-Plated Stainless Steel | IP20 | CAN/CSA-C22.2 No. 182.3, IEC 61076-3-124, UL 1977 | 0000000 | 0000 |
Straight Vertical Mount ix Industrial B-Coded Socket | ||||||||
Shielded | ||||||||
ix Industrial | __ | __ | 10 | Nickel-Plated Stainless Steel | IP20 | CAN/CSA-C22.2 No. 182.3, IEC 61076-3-124, UL 1977 | 0000000 | 0000 |
ix Industrial Cords
Securely connect equipment in data or signal applications, such as linking a servomotor and encoder. Because they have smaller connectors than standard cords, you can connect them to smaller equipment and snake them through tighter spaces. You can even use them to create multiple connection points in a compact area. These cords have a metal locking tab that secures the connectors to sockets and is less likely to break than plastic ones if yanked or bumped. All of these cords are shielded to block interference from nearby equipment. They will connect with any ix industrial sockets that meet IEC 61076-3-124. They also meet UL data transmission standards and Canadian electrical standards. You can also use them as an alternative to cords with D-sub connectors.
For technical drawings and 3-D models, click on a part number.
Length, ft. | Voltage | Current, A | Wire Gauge | Number of Wires | Cord OD | Shield Type | Temperature Range, °F | Features | Environmental Rating | Specifications Met | Color | Each | |
Shielded | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 50V AC/60V DC | 1.5 | 26 | 10 | 0.25" | Braid | -20° to 175° | Locking Tab | IP20 | CAN/CSA-C22.2 No. 182.3, IEC 61076-3-124, UL 1977 | Gray | 0000000 | 000000 |
3 1/4 | 50V AC/60V DC | 1.5 | 26 | 10 | 0.25" | Braid | -20° to 175° | Locking Tab | IP20 | CAN/CSA-C22.2 No. 182.3, IEC 61076-3-124, UL 1977 | Gray | 0000000 | 00000 |
5 | 50V AC/60V DC | 1.5 | 26 | 10 | 0.25" | Braid | -20° to 175° | Locking Tab | IP20 | CAN/CSA-C22.2 No. 182.3, IEC 61076-3-124, UL 1977 | Gray | 0000000 | 00000 |
9 3/4 | 50V AC/60V DC | 1.5 | 26 | 10 | 0.25" | Braid | -20° to 175° | Locking Tab | IP20 | CAN/CSA-C22.2 No. 182.3, IEC 61076-3-124, UL 1977 | Gray | 0000000 | 00000 |
16 1/2 | 50V AC/60V DC | 1.5 | 26 | 10 | 0.25" | Braid | -20° to 175° | Locking Tab | IP20 | CAN/CSA-C22.2 No. 182.3, IEC 61076-3-124, UL 1977 | Gray | 0000000 | 00000 |
24 1/2 | 50V AC/60V DC | 1.5 | 26 | 10 | 0.25" | Braid | -20° to 175° | Locking Tab | IP20 | CAN/CSA-C22.2 No. 182.3, IEC 61076-3-124, UL 1977 | Gray | 0000000 | 00000 |