Matching Flow Diagrams to Replace an Air Directional Control Valve
More
Choosing an Air Directional Control Valve
More
About Flow Control Valves
Also known as cylinder speed controls, flow control valves let you control the extension or retraction speed of your air cylinder. They regulate airflow as it passes from the valve's inlet to its outlet. Air flows freely in the opposite direction.
More
Inline Air Flow Control Valves
Designed to be mounted inline, these valves can be installed in an easy-to-reach location along your line. Flow control valves control the speed of air-powered equipment by adjusting the volume of airflow. They control flow in one direction as air moves from the inlet to the outlet. Air flows freely in the opposite direction. Typically, valves are installed to control flow as it exits the cylinder (meter out), but they may also be installed to control flow as it enters the cylinder (meter in). For the best control, mount them as close to the cylinder as possible to minimize the length of tubing or piping between the cylinder and the valve.
NPTF (Dryseal) threads are compatible with NPT threads.
Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port. Valves with barbed ports are for use with soft plastic or rubber tubing; insert the barbed port into the tubing.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
For technical drawings and 3-D models, click on a part number.
Inlet Pipe Size | Outlet Pipe Size | Flow Coefficient (Cv) | Maximum Flow Rate @ 100 psi | Max. Pressure, psi | Temp. Range, °F | Flow Adjustment Mechanism | Flow Control Type (ISO Designation) | Each | |
Nylon Plastic Body | |||||||||
---|---|---|---|---|---|---|---|---|---|
1/8 | 1/8 | 0.118 | 9.1 scfm | 145 | 35° to 155° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 000000 |
1/4 | 1/4 | 0.22 | 13.5 scfm | 145 | 35° to 155° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
3/8 | 3/8 | 0.352 | 20 scfm | 145 | 35° to 155° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
1/2 | 1/2 | 0.523 | 30.2 scfm | 145 | 35° to 155° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
Flow Rate @ 100 psi | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Inlet Pipe Size | For Outlet Tube ID | Flow Coefficient (Cv) | Min. | Max. | Max. Pressure, psi | Temp. Range, °F | Flow Adjustment Mechanism | Flow Control Type (ISO Designation) | Each | |
Brass Body | ||||||||||
1/8 | 3/16" | 0.1 | 1 scfm | 7 scfm | 250 | -40° to 250° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 000000 |
× Threaded Female
Outlet with Aluminum Body
Flow Rate @ 100 psi | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Inlet Pipe Size | Outlet Pipe Size | Flow Coefficient (Cv) | Min. | Max. | Max. Pressure, psi | Temp. Range, °F | Flow Adjustment Mechanism | Flow Control Type (ISO Designation) | Each | |
Aluminum Body | ||||||||||
1/8 | 1/8 | 0.8 | 1 scfm | 47 scfm | 250 | -40° to 250° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 000000 |
1/4 | 1/4 | 1.2 | 1 scfm | 66 scfm | 250 | -40° to 250° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
3/8 | 3/8 | 2.6 | 1 scfm | 149 scfm | 250 | -40° to 250° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
1/2 | 1/2 | 3.1 | 1 scfm | 173 scfm | 250 | -40° to 250° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 000000 |
Flow Rate @ 100 psi | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Inlet Thread Size | For Outlet Tube ID | Flow Coefficient (Cv) | Min. | Max. | Max. Pressure, psi | Temp. Range, °F | Flow Adjustment Mechanism | Flow Control Type (ISO Designation) | Each | |
Brass Body | ||||||||||
10-32 | 3/16" | 0.1 | 1 scfm | 7 scfm | 250 | -40° to 250° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 000000 |
Flow Rate @ 100 psi | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Inlet Thread Size | Outlet Thread Size | Flow Coefficient (Cv) | Min. | Max. | Max. Pressure, psi | Temp. Range, °F | Flow Adjustment Mechanism | Flow Control Type (ISO Designation) | Each | |
Brass Body | ||||||||||
1/4"-28 | 1/4"-28 | 0.1 | 1 scfm | 8 scfm | 250 | -40° to 250° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 000000 |
Flow Rate @ 73 psi | Flow Rate @ 100 psi | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Inlet Tube OD | For Outlet Tube OD | Flow Coefficient (Cv) | Min. | Max. | Min. | Max. | Max. Pressure, psi | Temp. Range, °F | Flow Adjustment Mechanism | Flow Control Type (ISO Designation) | Each | |
PBT Plastic Body | ||||||||||||
1/8" | 1/8" | 0.1 | 0 scfm | 4 scfm | __ | __ | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 000000 |
5/32" | 5/32" | 0.13 | 0 scfm | 5.2 scfm | __ | __ | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
3/16" | 3/16" | 0.19 | __ | __ | 0 scfm | 6.1 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
3/16" | 3/16" | 0.25 | __ | __ | 0 scfm | 8 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
1/4" | 1/4" | 0.19 | 0 scfm | 9.2 scfm | __ | __ | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
1/4" | 1/4" | 0.42 | 0 scfm | 15.6 scfm | __ | __ | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
1/4" | 1/4" | 0.47 | 0 scfm | 18.4 scfm | __ | __ | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
5/16" | 5/16" | 0.47 | 0 scfm | 18.4 scfm | __ | __ | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
5/16" | 5/16" | 0.67 | 0 scfm | 26.4 scfm | __ | __ | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
3/8" | 3/8" | 0.93 | 0 scfm | 37 scfm | __ | __ | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
3/8" | 3/8" | 1.06 | 0 scfm | 37 scfm | __ | __ | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
1/2" | 1/2" | 1.41 | 0 scfm | 55.6 scfm | __ | __ | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
4mm | 4mm | 0.13 | 0 scfm | 5.2 scfm | __ | __ | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
6mm | 6mm | 0.23 | 0 scfm | 9.2 scfm | __ | __ | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
6mm | 6mm | 0.29 | 0 scfm | 11.6 scfm | __ | __ | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
6mm | 6mm | 0.42 | 0 scfm | 16.8 scfm | __ | __ | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
8mm | 8mm | 0.47 | 0 scfm | 18.4 scfm | __ | __ | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
8mm | 8mm | 0.67 | 0 scfm | 26.4 scfm | __ | __ | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
10mm | 10mm | 0.93 | 0 scfm | 36.8 scfm | __ | __ | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 000000000 | 00000 |
12mm | 12mm | 0.93 | 0 scfm | 37 scfm | __ | __ | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
Flow Rate @ 100 psi | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Inlet Tube ID | For Outlet Tube ID | Flow Coefficient (Cv) | Min. | Max. | Max. Pressure, psi | Temp. Range, °F | Flow Adjustment Mechanism | Flow Control Type (ISO Designation) | Each | |
Brass Body | ||||||||||
3/16" | 3/16" | 0.1 | 1 scfm | 7 scfm | 250 | -40° to 250° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 000000 |
Inline Air Flow Control Valves with Flow Indicator
A flow indicator on these valves provides a relative measure of the air flowing through the valve, from off to full volume, similar to the volume dial on a speaker. The indicator’s numeric increments make it easy to set the valve to the same flow rate with each use. They adjust the volume of airflow to control the speed of air-powered equipment. Valves control flow in one direction as air moves from the inlet to the outlet. Air flows freely in the opposite direction. Typically, valves are installed to control flow as it exits the cylinder (meter out), but they may also be installed to control flow as it enters the cylinder (meter in). Designed to be mounted inline, they can be installed in an easy-to-reach location along your line. For the best control, mount them as close to the cylinder as possible to minimize the length of tubing or piping between the cylinder and the valve.
NPTF (Dryseal) threads are compatible with NPT threads.
Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
Flow Rate @ 73 psi | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Inlet Pipe Size | Outlet Pipe Size | Flow Coefficient (Cv) | Min. | Max. | Max. Pressure, psi | Temp. Range, °F | Flow Adjustment Mechanism | Flow Control Type (ISO Designation) | Each | |
Aluminum Body | ||||||||||
1/4 | 1/4 | 0.82 | 0 scfm | 34.45 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 000000 |
3/8 | 3/8 | 0.82 | 0 scfm | 34.45 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
Flow Rate @ 100 psi | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Inlet Pipe Size | Outlet Pipe Size | Flow Coefficient (Cv) | Min. | Max. | Max. Pressure, psi | Temp. Range, °F | Flow Adjustment Mechanism | Flow Control Type (ISO Designation) | Each | |
Brass Body | ||||||||||
1/8 | 1/8 | 1.4 | 15 scfm | 32 scfm | 250 | 0° to 180° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 000000 |
1/4 | 1/4 | 1.22 | 28 scfm | 75 scfm | 250 | 0° to 180° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
3/8 | 3/8 | 2.58 | 59 scfm | 139 scfm | 250 | 0° to 180° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 000000 |
1/2 | 1/2 | 5.51 | 126 scfm | 183 scfm | 250 | 0° to 180° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 000000 |
3/4 | 3/4 | 6.12 | 140 scfm | 327 scfm | 250 | 0° to 180° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 000000 |
Flow Rate @ 73 psi | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Inlet Pipe Size | Outlet Pipe Size | Flow Coefficient (Cv) | Min. | Max. | Max. Pressure, psi | Temp. Range, °F | Flow Adjustment Mechanism | Flow Control Type (ISO Designation) | Each | |
Aluminum Body | ||||||||||
1/4 | 1/4 | 0.82 | 0 scfm | 32.4 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 000000 |
3/8 | 3/8 | 0.82 | 0 scfm | 32.4 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
Flow Rate @ 73 psi | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Inlet Tube OD | For Outlet Tube OD | Flow Coefficient (Cv) | Min. | Max. | Max. Pressure, psi | Temp. Range, °F | Flow Adjustment Mechanism | Flow Control Type (ISO Designation) | Each | |
PBT Plastic Body | ||||||||||
1/8" | 1/8" | 0.06 | 0 scfm | 2.52 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 000000 |
5/32" | 5/32" | 0.08 | 0 scfm | 3.36 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
1/4" | 1/4" | 0.08 | 0 scfm | 5.18 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
1/4" | 1/4" | 0.22 | 0 scfm | 8.64 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
1/4" | 1/4" | 0.29 | 0 scfm | 12.18 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
5/16" | 5/16" | 0.29 | 0 scfm | 13.82 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
3/8" | 3/8" | 0.53 | 0 scfm | 20.74 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
3/8" | 3/8" | 0.6 | 0 scfm | 25.21 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
1/2" | 1/2" | 0.77 | 0 scfm | 30.24 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
4mm | 4mm | 0.08 | 0 scfm | 3.36 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
6mm | 6mm | 0.08 | 0 scfm | 5.18 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
6mm | 6mm | 0.22 | 0 scfm | 8.64 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
6mm | 6mm | 0.29 | 0 scfm | 12.18 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
8mm | 8mm | 0.26 | 0 scfm | 10.37 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
8mm | 8mm | 0.42 | 0 scfm | 17.65 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
10mm | 10mm | 0.29 | 0 scfm | 19 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
10mm | 10mm | 0.53 | 0 scfm | 20.74 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
12mm | 12mm | 0.77 | 0 scfm | 30.24 scfm | 145 | 25° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 00000000 | 00000 |
Inline Corrosion-Resistant Air Flow Control Valves
Made of stainless steel and plastic parts, these valves are more corrosion resistant than valves made of brass, aluminum, or zinc. They control the speed of air-powered equipment by adjusting the volume of airflow. Use them to control flow in one direction as air moves from the inlet to the outlet. Air flows freely in the opposite direction. Typically, valves are installed to control flow as it exits the cylinder (meter out), but they may also be installed to control flow as it enters the cylinder (meter in). They’re designed to be mounted inline, allowing you to install them in an easy-to-reach location along your line. For the best control, mount them as close to the cylinder as possible to minimize the length of tubing between the cylinder and the valve. Insert plastic or soft metal tubing into the push-to-connect ports.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
For technical drawings and 3-D models, click on a part number.
For Inlet Tube OD | For Outlet Tube OD | Flow Coefficient (Cv) | Maximum Flow Rate @ 73 psi | Max. Pressure, psi | Temp. Range, °F | Flow Adjustment Mechanism | Flow Control Type (ISO Designation) | Each | |
Push-to-Connect Female Inlet × Push-to-Connect Female Outlet | |||||||||
---|---|---|---|---|---|---|---|---|---|
PBT Plastic Body | |||||||||
1/8" | 1/8" | 0.1 | 4 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 000000 |
5/32" | 5/32" | 0.1 | 4 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
5/32" | 5/32" | 0.13 | 5.2 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
3/16" | 3/16" | 0.1 | 4 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
3/16" | 3/16" | 0.29 | 11.6 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
1/4" | 1/4" | 0.1 | 4 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
1/4" | 1/4" | 0.19 | 9.2 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
1/4" | 1/4" | 0.42 | 16.8 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
1/4" | 1/4" | 0.46 | 18.4 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
5/16" | 5/16" | 0.46 | 18.4 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
5/16" | 5/16" | 0.66 | 26.4 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
3/8" | 3/8" | 0.78 | 36.8 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
3/8" | 3/8" | 1.05 | 42 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
1/2" | 1/2" | 1.17 | 55.6 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
3.2mm | 3.2mm | 0.1 | 4 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
4mm | 4mm | 0.1 | 4 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
4mm | 4mm | 0.13 | 5.2 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
6mm | 6mm | 0.1 | 4 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
6mm | 6mm | 0.23 | 9.2 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
6mm | 6mm | 0.29 | 11.6 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
6mm | 6mm | 0.42 | 16.8 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
8mm | 8mm | 0.46 | 18.4 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
8mm | 8mm | 0.66 | 26.4 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
10mm | 10mm | 0.92 | 36.8 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
10mm | 10mm | 1.05 | 42 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
12mm | 12mm | 0.92 | 36.8 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
12mm | 12mm | 1.39 | 55.6 scfm | 145 | 32° to 140° | Dial | Exiting Cylinder (Meter Out), Entering Cylinder (Meter In) | 0000000 | 00000 |
Two-Action Electrically Operated Air Directional Control Valves
Also known as 4-way and 5/2 valves, these valves create two actions, such as extending and then retracting a double-acting cylinder. Apply voltage to the electrical connection to actuate. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is by spring, so they return to their original position as soon as voltage is removed.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
For technical drawings and 3-D models, click on a part number.
O'all | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Size | Outlet Size | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating | Lg. | Wd. | Ht. | Mount Type | Mounting Fasteners Included | Choose a Voltage | Each | |
Threaded Female Inlet × Threaded Female Outlet—Push-to-Connect Exhaust | ||||||||||||||
4 | 1/4 NPT | 1/4 NPT | 45 | 0.75 | 44-145 | Not Rated | 5 1/16" | 7/8" | 1 3/8" | Screw In, Inline | No | 0000000 | 0000000 |
Input-Selecting Air Directional Control Valves
Also known as shuttle valves and "or" valves, these valves select between the higher of two inlet pressures to power one outlet port. They're often used in emergency systems where the lower pressure input acts as a backup to the higher pressure input.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | For Inlet Tube OD | For Outlet Tube OD | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating | Lg. | Wd. | Ht. | Mount Type | Each | |
Push-to-Connect Female Inlet × Push-to-Connect Female Outlet | ||||||||||||
3 | 5/32" | 5/32" | 27.12 | 0.48 | 0-125 | Not Rated | 1 5/8" | 5/8" | 1 1/8" | Inline | 0000000 | 000000 |
3 | 1/4" | 1/4" | 27.12 | 0.48 | 0-125 | Not Rated | 1 5/8" | 5/8" | 1 1/8" | Inline | 0000000 | 00000 |
Inline Air-Release Valves for Water
- Max. Pressure: 125 psi
- Temperature Range: 40° to 240° F
Eliminate air pockets without stopping flow—these valves have an internal wire brush that traps air bubbles and discharges them through the top relief port while allowing inline flow from the inlet to the outlet. They are often used to increase efficiency in heating and cooling systems. The vented relief port exhausts discharge directly. Valves have a durable bronze body for a long service life.