About Timer Relays
More
Compact Spade-Terminal Relays






Fit these relays where standard spade-terminal relays are too big. You can connect them three ways. Plug them into a socket (sold separately), connect them with quick-disconnect terminals, or solder wires directly to the terminals. An LED indicator shows you the status of the relay, so you know it’s connected and wired correctly.
Relays that control 2 or more circuits have a lockable test button, so you can test their function. When you press the button, the relay switches contacts. Use this button when checking a relay for proper function before installing it, or when investigating issues with wired relays.
Relay sockets mount directly on 35 mm DIN rail (also known as DIN 3 rail) for fast installation. You can also mount them to a flat surface using screws.
For technical drawings and 3-D models, click on a part number.
Relays | Relay Sockets with Screw Terminals | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Maximum Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||
Relay-Socket Mount | ||||||||||||
8 | 24V AC | 46 | 15 A @ 120 V AC/24 V DC | 250V AC | 1.1" | 0.9" | 1.6" | 0.197" | 00000000 | 000000 | 0000000 | 000000 |
8 | 120V AC | 9 | 15 A @ 120 V AC/24 V DC | 250V AC | 1.1" | 0.9" | 1.6" | 0.197" | 00000000 | 00000 | 0000000 | 00000 |
8 | 24V DC | 37 | 15 A @ 120 V AC/24 V DC | 250V AC | 1.1" | 0.9" | 1.6" | 0.197" | 00000000 | 00000 | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||
Relay-Socket Mount | ||||||||||||
8 | 24V AC | 50 | 10 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
8 | 24V AC | 50 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 0000 |
8 | 120V AC | 10 | 10 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
8 | 120V AC | 10 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 0000 |
8 | 240V AC | 5 | 10 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
8 | 240V AC | 5 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 0000 |
8 | 12V DC | 75 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 0000 |
8 | 12V DC | 92 | 10 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
8 | 24V DC | 38 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 0000 |
8 | 24V DC | 46 | 10 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | ||||||||||||
Relay-Socket Mount | ||||||||||||
11 | 24V AC | 63 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
11 | 120V AC | 13 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
11 | 240V AC | 6 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
11 | 12V DC | 117 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
11 | 24V DC | 58 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.2" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
4 Circuits Controlled with 4 Off (Normally Open) or 4 On (Normally Closed)—4PDT | ||||||||||||
Relay-Socket Mount | ||||||||||||
14 | 24V AC | 50 | 8 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
14 | 24V AC | 63 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.6" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
14 | 120V AC | 10 | 8 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
14 | 120V AC | 13 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.6" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
14 | 240V AC | 5 | 8 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
14 | 240V AC | 6 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.6" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
14 | 12V DC | 92 | 8 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
14 | 12V DC | 125 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.6" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
14 | 24V DC | 6 | 15 A @ 120 V AC 12 A @ 24 V DC | 300V AC | 1.1" | 1.6" | 1.6" | 0.187" | 00000000 | 00000 | 0000000 | 00000 |
14 | 24V DC | 46 | 8 A @ 120 V AC/24 V DC | 300V AC | 1.1" | 0.9" | 1.6" | 0.11" | 000000000 | 00000 | 0000000 | 00000 |
Spade-Terminal Relays
Using a low-current signal, these relays are often used to control small motors and heaters. These relays attach to quick-disconnect terminals.
Surface mount relays, also known as power relays, have a slot on the flange for mounting them to flat surfaces.
Relay-socket mount relays, also known as ice cube relays, offer three ways to connect. Plug them into a socket (sold separately), connect them with quick-disconnect terminals, or solder wires directly to the terminals.
Relay-socket/surface mount relays can plug into a socket or mount to a flat surface.
Relay sockets mount directly on 35 mm DIN rail (also known as DIN 3 rail) for fast installation. They can also mount to a flat surface.




Relays | Relay Sockets with Screw Terminals | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Maximum Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||
5 | 24V AC | 84 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 000000 | 0000000 | 000000 |
5 | 120V AC | 18 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
5 | 240V AC | 9 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
5 | 12V DC | 100 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
5 | 24V DC | 51 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||
8 | 12V AC | 168 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
8 | 24V AC | 84 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
8 | 120V AC | 18 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
8 | 240V AC | 9 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
8 | 12V DC | 100 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
8 | 24V DC | 51 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
8 | 120V DC | 11 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | ||||||||||||
11 | 12V AC | 230 | 250V AC | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 000000 | 0000000 | 00000 |
11 | 24V AC | 115 | 250V AC | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
11 | 120V AC | 24 | 250V AC | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
11 | 240V AC | 12 | 250V AC | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
11 | 12V DC | 100 | 250V AC | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
11 | 24V DC | 51 | 250V AC | 1/2 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |



With Screw
Terminals
Relays | Relay Sockets with Screw Terminals | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Maximum Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||
8 | 24V AC | 46 | 250V AC | 1/2 hp @ 120 V AC | 1.8" | 0.9" | 1.4" | 0.2" | 00000000 | 000000 | 0000000 | 000000 |
8 | 120V AC | 9 | 250V AC | 1/2 hp @ 120 V AC | 1.8" | 0.9" | 1.4" | 0.2" | 00000000 | 00000 | 0000000 | 00000 |
8 | 24V DC | 37 | 250V AC | 1/2 hp @ 120 V AC | 1.8" | 0.9" | 1.4" | 0.2" | 00000000 | 00000 | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||
8 | 24V AC | 46 | 250V AC | 1/2 hp @ 120 V AC | 1.8" | 0.9" | 1.4" | 0.2" | 00000000 | 00000 | 0000000 | 00000 |
8 | 120V AC | 9 | 250V AC | 1/2 hp @ 120 V AC | 1.8" | 0.9" | 1.4" | 0.2" | 00000000 | 00000 | 0000000 | 00000 |
8 | 24V DC | 37 | 250V AC | 1/2 hp @ 120 V AC | 1.8" | 0.9" | 1.4" | 0.2" | 00000000 | 00000 | 0000000 | 00000 |
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | ||||||||||||
11 | 24V AC | 67 | 250V AC | 1/2 hp @ 240 V AC | 1.8" | 1.3" | 1.4" | 0.2" | 00000000 | 00000 | 0000000 | 00000 |
11 | 24V DC | 59 | 250V AC | 1/2 hp @ 240 V AC | 1.8" | 1.3" | 1.4" | 0.2" | 00000000 | 00000 | 0000000 | 00000 |

Number of Terminals | Input Voltage | Control Current, mA | Maximum Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
5 | 24V AC | 37 | 380V AC | 1/3 hp @ 120 V AC | 0.6" | 1.8" | 1.16" | 0.187" | 0000000 | 000000 |
5 | 24V DC | 21 | 380V AC | 1/3 hp @ 120 V AC | 0.6" | 1.8" | 1.16" | 0.187" | 0000000 | 0000 |
5 | 120V AC | 7 | 380V AC | 1/3 hp @ 120 V AC | 0.6" | 1.8" | 1.16" | 0.187" | 0000000 | 00000 |
Thin Spade-Terminal Relays



with Screw
Terminals

Spring-Clamp
Terminals
Save space in your control cabinet. These narrow relays are often used for low-current switching applications, such as on small motors and pilot lights. They plug into a socket (sold separately) for quick installation.
Relay sockets mount directly on 35 mm DIN rail (also known as DIN 3 rail). Those with screw terminals connect and disconnect wire when you turn the screws. They can also mount to a flat surface. Those with spring-clamp terminals connect and disconnect to wires without needing to turn screws. Insert a screwdriver into the slot to release the spring clamp holding the wire in place.
For technical drawings and 3-D models, click on a part number.
Relays | Relay Sockets with Screw Terminals | Relay Sockets with Spring-Clamp Terminals | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Maximum Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | Each | |||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||
Relay-Socket Mount | ||||||||||||||
5 | 24V AC | 44 | 10 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.187" | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
5 | 120V AC | 8 | 10 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.187" | 0000000 | 00000 | 0000000 | 0000 | 0000000 | 0000 |
5 | 240V AC | 4 | 10 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.187" | 0000000 | 00000 | 0000000 | 0000 | 0000000 | 0000 |
5 | 6V DC | 87 | 10 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.187" | 0000000 | 0000 | 0000000 | 0000 | 0000000 | 0000 |
5 | 12V DC | 43 | 10 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.187" | 0000000 | 0000 | 0000000 | 0000 | 0000000 | 0000 |
5 | 24V DC | 22 | 10 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.187" | 0000000 | 0000 | 0000000 | 0000 | 0000000 | 0000 |
5 | 48V DC | 11 | 10 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.187" | 0000000 | 0000 | 0000000 | 0000 | 0000000 | 0000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||||
Relay-Socket Mount | ||||||||||||||
8 | 24V AC | 44 | 5 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.098" | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
8 | 120V AC | 8 | 5 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.098" | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
8 | 240V AC | 4 | 5 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.098" | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
8 | 6V DC | 87 | 5 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.098" | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
8 | 12V DC | 43 | 5 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.098" | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
8 | 24V DC | 22 | 5 A @ 120 V AC/24 V DC | 380V AC | 1.1" | 0.5" | 1.4" | 0.098" | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
Solid State Spade-Terminal Relays
Often used for high-speed switching at low-current levels, these solid state relays have no moving parts, so they switch faster, last longer, and are quieter than mechanical switches.
Relay sockets mount directly on 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
Relay sockets with screw terminals can also mount to a flat surface.


with Screw
Terminals
Relays | Relay Sockets with Screw Terminals | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Switching Current @ 240V AC | Max. Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | |||||||||||
4 | 5V DC, 6V DC, 12V DC, 24V DC | 2A | 264V AC | 1.1" | 0.5" | 1.4" | 0.187" | 0000000 | 000000 | 0000000 | 00000 |
8 | 5V DC, 6V DC, 12V DC, 24V DC | 3A | 48V DC | 1.102" | 0.85" | 1.437" | 0.187" | 000000 | 00000 | 0000000 | 00000 |
Circular-Pin Relays



8-Terminal
Relay

The circular pin terminals plug into relay sockets for easy installation. Also known as ice cube relays.
Relays rated for horsepower (hp) are built to handle tough, repetitive-use applications.
Relays with a lockable test button allow you to test whether a relay is working without an electrical signal. They’re helpful for testing relays before you install them, or for checking that installed relays are working properly.
Relay sockets (sold separately) mount to 35 mm DIN rail (also known as DIN 3 rail) or can be mounted to a flat surface.
Relays | Relay Sockets | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Features | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
8 | 24V AC | 84 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 000000 | 000000 | 0000000 | 00000 |
8 | 120V AC | 18 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 000000 | 00000 | 0000000 | 0000 |
8 | 12V DC | 100 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 0000000 | 00000 | 0000000 | 0000 |
8 | 24V DC | 52 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 000000 | 00000 | 0000000 | 0000 |
8 | 110V DC | 11 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 0000000 | 00000 | 0000000 | 0000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
8 | 12V AC | 193 | 10 A @ 240 V AC | 250V AC | __ | 1.4" | 1.4" | 2.1" | Lockable Test Button | 0000000 | 00000 | 0000000 | 0000 |
8 | 12V AC | 250 | 10 A @ 277 V AC/30 V DC | __ | 1/3 hp @ 120 V AC 1 hp @ 277 V AC | 1.4" | 1.38" | 2.2" | __ | 0000000 | 00000 | 0000000 | 0000 |
8 | 24V AC | 84 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 0000000 | 00000 | 0000000 | 0000 |
8 | 24V AC | 96 | 10 A @ 240 V AC | 250V AC | __ | 1.4" | 1.4" | 2.1" | Lockable Test Button | 0000000 | 00000 | 0000000 | 0000 |
8 | 24V AC | 96 | 10 A @ 240 V AC | 250V AC | __ | 1.4" | 1.4" | 2.1" | Lockable Test Button, LED Power Indicator | 0000000 | 00000 | 0000000 | 0000 |
8 | 120V AC | 18 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 0000000 | 00000 | 0000000 | 0000 |
8 | 120V AC | 19 | 10 A @ 240 V AC | 250V AC | __ | 1.4" | 1.4" | 2.1" | Lockable Test Button | 0000000 | 00000 | 0000000 | 0000 |
8 | 120V AC | 19 | 10 A @ 240 V AC | 250V AC | __ | 1.4" | 1.4" | 2.1" | Lockable Test Button, LED Power Indicator | 0000000 | 00000 | 0000000 | 0000 |
8 | 12V DC | 100 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 0000000 | 00000 | 0000000 | 0000 |
8 | 12V DC | 112 | 10 A @ 240 V AC | 250V AC | __ | 1.4" | 1.4" | 2.1" | Lockable Test Button | 0000000 | 00000 | 0000000 | 0000 |
8 | 24V DC | 52 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 0000000 | 00000 | 0000000 | 0000 |
8 | 24V DC | 55 | 10 A @ 240 V AC | 250V AC | __ | 1.4" | 1.4" | 2.1" | Lockable Test Button | 0000000 | 00000 | 0000000 | 0000 |
8 | 24V DC | 55 | 10 A @ 240 V AC | 250V AC | __ | 1.4" | 1.4" | 2.1" | Lockable Test Button, LED Power Indicator | 0000000 | 00000 | 0000000 | 0000 |
8 | 240V AC | 9 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 0000000 | 00000 | 0000000 | 0000 |
8 | 240V AC | 9 | 10 A @ 240 V AC | 250V AC | __ | 1.4" | 1.4" | 2.1" | Lockable Test Button | 0000000 | 00000 | 0000000 | 0000 |
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | |||||||||||||
11 | 24V AC | 84 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 0000000 | 00000 | 0000000 | 00000 |
11 | 24V AC | 96 | 10 A @ 240 V AC | 250V AC | __ | 1.4" | 1.4" | 2.1" | Lockable Test Button | 0000000 | 00000 | 0000000 | 00000 |
11 | 120V AC | 18 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 0000000 | 00000 | 0000000 | 00000 |
11 | 120V AC | 19 | 10 A @ 240 V AC | 250V AC | __ | 1.4" | 1.4" | 2.1" | Lockable Test Button, LED Power Indicator | 0000000 | 00000 | 0000000 | 00000 |
11 | 12V DC | 100 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 0000000 | 00000 | 0000000 | 00000 |
11 | 12V DC | 112 | 10 A @ 240 V AC | 250V AC | __ | 1.4" | 1.4" | 2.1" | Lockable Test Button | 0000000 | 00000 | 0000000 | 00000 |
11 | 24V DC | 52 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 0000000 | 00000 | 0000000 | 00000 |
11 | 24V DC | 55 | 10 A @ 240 V AC | 250V AC | __ | 1.4" | 1.4" | 2.1" | Lockable Test Button | 0000000 | 00000 | 0000000 | 00000 |
11 | 240V AC | 9 | 10 A @ 240 V AC/28 V DC | __ | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | __ | 0000000 | 00000 | 0000000 | 00000 |
11 | 240V AC | 9 | 10 A @ 240 V AC | 250V AC | __ | 1.4" | 1.4" | 2.1" | Lockable Test Button | 0000000 | 00000 | 0000000 | 00000 |
DIN-Rail Mount Interface Relays






Isolate input and output circuits to prevent damage from voltage spikes, reduce signal interference, and amplify signal. These relays interface between your controller and components—they receive a signal from the controller to switch power on or off to the components. All have an LED indicator that shows you if your switch is actuated, so you know it’s connected and wired correctly. Use them to communicate signals to devices like motors or sensors. Mount them on 35 mm DIN rail (also known as DIN 3 rail).
Relays with spring-clamp terminals connect and disconnect to wires without needing to turn screws. Because there is no screw, these connections have less risk of loosening over time than screw terminals, even when there is vibration.
Relays with a fuse holder slot give you the option for additional overload protection. If the current exceeds the fuse’s rating, the fuse will blow and break the circuit. This prevents the relay from overheating, breaking, or causing a fire. The fuse holder is sold separately. You can use these relays without the fuse holder as a standard interface relay.
Relays with PLC output protection prevent voltage spikes created by the relay from damaging the output channel on your programmable logic controller (PLC).
For technical drawings and 3-D models, click on a part number.
Relays with Relay Sockets | Replacement Relays | Fuse Holders | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ 240V AC | hp @ Switching Voltage | Ht. | Wd. | Dp. | Features | Each | Each | Each | |||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||
With Screw Terminals | ||||||||||||||
5 | 24V AC | 45 | 16A | 1/3 hp @ 120 V AC | 3.3" | 0.6" | 2.7" | LED Indicator, PLC Output Protection | 0000000 | 000000 | 0000000 | 000000 | 000000 | 00 |
5 | 120V AC | 8 | 16A | 1/3 hp @ 120 V AC | 3.3" | 0.6" | 2.7" | LED Indicator, PLC Output Protection | 0000000 | 00000 | 0000000 | 00000 | 000000 | 00 |
5 | 24V AC, 24V DC | 11 | 6A | __ | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 00000000 | 00000 | 0000000 | 0000 | 00000000 | 00000 |
5 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC, 60V DC, 240V DC | 19 | 6A | __ | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 00000000 | 00000 | 0000000 | 0000 | 00000000 | 0000 |
5 | 120V AC, 120V DC | 5 | 6A | __ | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 00000000 | 00000 | 0000000 | 0000 | 00000000 | 0000 |
5 | 24V DC | 20 | 16A | 1/3 hp @ 120 V AC | 3.3" | 0.6" | 2.7" | LED Indicator, PLC Output Protection | 0000000 | 00000 | 0000000 | 0000 | 000000 | 00 |
With Spring-Clamp Terminals | ||||||||||||||
5 | 24V AC, 24V DC | 11 | 6A | __ | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 00000000 | 00000 | 0000000 | 0000 | 00000000 | 0000 |
5 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC, 60V DC, 240V DC | 19 | 6A | __ | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 00000000 | 00000 | 0000000 | 0000 | 00000000 | 0000 |
5 | 120V AC, 120V DC | 5 | 6A | __ | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 00000000 | 00000 | 0000000 | 0000 | 00000000 | 0000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||||
With Screw Terminals | ||||||||||||||
8 | 24V AC | 45 | 8A | 1/4 hp @ 120 V AC | 3.3" | 0.6" | 2.7" | LED Indicator, PLC Output Protection | 0000000 | 00000 | 0000000 | 00000 | 000000 | 00 |
8 | 120V AC | 8 | 8A | 1/4 hp @ 120 V AC | 3.3" | 0.6" | 2.7" | LED Indicator, PLC Output Protection | 0000000 | 00000 | 0000000 | 00000 | 000000 | 00 |
8 | 24V DC | 20 | 8A | 1/4 hp @ 120 V AC | 3.3" | 0.6" | 2.7" | LED Indicator, PLC Output Protection | 0000000 | 00000 | 0000000 | 0000 | 000000 | 00 |
With Spring-Clamp Terminals | ||||||||||||||
8 | 120V AC | 12 | 10A | 1/3 hp @ 120 V AC | 3.9" | 1.2" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
8 | 24V DC | 40 | 10A | 1/3 hp @ 120 V AC | 3.9" | 1.2" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | ||||||||||||||
With Screw Terminals | ||||||||||||||
11 | 24V AC | 53 | 10A | 1/3 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
11 | 120V AC | 12 | 10A | 1/3 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
11 | 12V DC | 86 | 10A | 1/3 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
11 | 24V DC | 40 | 10A | 1/3 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
4 Circuits Controlled with 4 Off (Normally Open) or 4 On (Normally Closed)—4PDT | ||||||||||||||
With Screw Terminals | ||||||||||||||
14 | 24V AC | 53 | 7A | 1/8 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
14 | 120V AC | 12 | 7A | 1/8 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
14 | 12V DC | 86 | 7A | 1/8 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
14 | 24V DC | 40 | 7A | 1/8 hp @ 120 V AC | 3.1" | 1.1" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
With Spring-Clamp Terminals | ||||||||||||||
14 | 24V AC | 53 | 7A | 1/8 hp @ 120 V AC | 3.9" | 1.2" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
14 | 12V DC | 86 | 7A | 1/8 hp @ 120 V AC | 3.9" | 1.2" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
14 | 24V DC | 40 | 7A | 1/8 hp @ 120 V AC | 3.9" | 1.2" | 3.3" | LED Indicator, PLC Output Protection | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
Interface Safety Relays

These relays pair the transmission reliability of an interface relay with the fail-safe operation of a safety relay. Use them to communicate signals to devices like motors or sensors. They have interlocking contacts—also known as force-guided or mechanically linked contacts—so opposing contacts won't close at the same time. This minimizes the chance of arcing, so electricity won't jump across the contacts and interfere with your relay or system. They also have an interface that isolates input and output circuits to prevent damage from voltage spikes, reduce signal interference, and amplify signal. Mount them on 35 mm DIN rail (also known as DIN 3 rail). The relays disconnect from the socket for quick replacement.
Relays with LED indicator light up when the relay is on, so you’ll know it’s wired correctly and can tell at a glance whether it’s on or off.
Relays | Replacement Relays | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage | hp @ Switching Voltage | Mechanical Life Cycles | Ht. | Wd. | Dp. | Features | Each | Each | ||
2 Circuits Controlled with 1 Off (Normally Open) and 1 On (Normally Closed)—DPST-1NO/1NC | ||||||||||||||
6 | 12V DC | 63 | 3 A @ 240 V AC/24 V DC | 250V AC, 125V DC | __ | 10,000,000 | 1.1" | 0.5" | 1.1" | Interlocked Opposing Contacts, LED Indicator | 0000000 | 000000 | 0000000 | 000000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||||
8 | 24V DC | 29 | 8 A @ 240 V AC | 250V AC | 1/2 hp @ 230 V AC | 10,000,000 | 3.1" | 0.6" | 2.4" | Interlocked Opposing Contacts | 0000000 | 00000 | 0000000 | 00000 |
Ice Cube Trays

Make ice cubes in your freezer.
Lg. | Wd. | Ht. | Makes Number of Cubes | Material | Color | Space Saving Features | Pkg. Qty. | Pkg. | |
11" | 4" | 1 1/2" | 14 | Plastic | White | Stackable | 2 | 0000000 | 00000 |
Ice Packs

Durable and reusable, these packs are less messy and keep contents colder longer than ice. Often used with beverages and food, they keep things cold but not frozen. All flex to wrap around objects and fit into tight spaces. The packs consist of smaller cubes that can be cut apart and used individually.