Portable Multi-Gas Detectors

When this detector senses high levels of combustible and toxic gases, it alerts you with an audible alarm, warning light, and vibrating alarm. You can adjust the alarm trigger points to suit your environment. There is also a motion sensor that sounds an alarm if the user becomes disabled.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check requires a regulator and cylinder (sold separately).
Note: LEL is lower explosive limit.
Detects (Measuring Range) | Volume | Temperature Range, °F | Batteries Included | Environmental Rating | Each | |
Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (0-100% LEL), Oxygen (0-30% Vol.), Carbon Monoxide (0-1,999 ppm), Hydrogen Sulfide (0-200 ppm) | 95 dBA @ 30 cm. | -40° to 140° | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 0 Groups IIC, IIB, IIA IP68 | 00000000 | 000000000 |
Surface-Mount Multi-Gas Detectors

An audible alarm and warning light alert you to the presence of propane, methane, hydrogen, and carbon monoxide. This detector has a relay for connection to auxiliary alarm systems. A programmable timer allows you to set whether the relay alarm is triggered immediately, or after 4 or 8 minutes of continuous gas exposure. The reset button suspends the alarm and restarts the cycle for 5 to 8 minutes in case of false alarm.
Import regulations restrict sales to the listed areas.
Detects (Trigger Point) , ppm | Volume | Temperature Range, ° F | Ht. | Wd. | Dp. | Voltage | Cord Lg., ft. | Fasteners Included | Mounting Hole Dia. | Cannot Be Sold To | Each | |
Propane (420); Methane (5,000); Hydrogen (200); Carbon Monoxide (150) | 80 dB @ 10 ft. | -20° to 120° | 6 3/4" | 3 1/4" | 1 3/4" | 120V AC | 6 | No | 3/16" | Canada | 0000000 | 0000000 |
Portable Multi-Gas Detectors with Probe

Use the probe to test the air in a hazardous area before entering. Great for confined spaces. This detector alerts you with an audible alarm, warning light, and vibrating alarm in the presence of combustible and toxic gases. You can adjust the alarm trigger points to suit your environment. There is also a motion sensor that sounds an alarm if the user becomes disabled.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check requires a regulator and cylinder (sold separately).
Note: LEL is lower explosive limit.
Detects (Measuring Range) | Volume | Temperature Range, °F | Batteries Included | Includes | Tube Lg., ft. | Environmental Rating | Each | |
Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (0-100% LEL), Oxygen (0-30% Vol.), Carbon Monoxide (0-1,999 ppm), Hydrogen Sulfide (0-200 ppm) | 95 dBA @ 30 cm. | -40° to 140° | Yes | Sampling Probe, Tubing Assembly, Rechargeable Lithium Ion Battery for Probe | 25 | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 0 Groups IIC, IIB, IIA IP68 | 00000000 | 000000000 |
Early-Warning Surface-Mount Hydrogen Detectors

This detector triggers a “caution” alert when a small amount of hydrogen is detected and a second “danger” alert if levels continue to rise. When hydrogen concentration reaches 1% by volume, a yellow warning light illuminates and the first relay closes to trigger a remote exhaust fan and/or alarm. When hydrogen reaches 2%, a red warning light illuminates, an alarm sounds, and the second relay closes to activate another remote exhaust fan and/or alarm.
Use the optional remote and cable to keep an eye on the detector’s alert status from a distance. Remote has a buzzer and the same yellow and red warning lights as the detector.
Trigger Point, % Vol. | Volume | Temperature Range, ° F | Ht. | Wd. | Dp. | Electrical Connection | Voltage | Fasteners Included | Mounting Hole Dia. | Each | |
1; 2 | 60 dB @ 10 ft. | 14° to 104° | 7" | 4 3/4" | 2 1/2" | Screw Terminals | 120V AC, 240V AC | No | 3/16" | 00000000 | 000000000 |
Surface-Mount Hydrogen Detectors

An audible alarm and warning light alert you to the presence of hydrogen. This detector has a relay for connection to auxiliary alarm systems. A programmable timer allows you to set whether the relay alarm is triggered immediately, or after 4 or 8 minutes of continuous gas exposure. The reset button suspends the alarm and restarts the cycle for 5 to 8 minutes in case of false alarm.
Import regulations restrict sales to the listed areas.
Trigger Point, ppm | Volume | Temperature Range, ° F | Ht. | Wd. | Dp. | Voltage | Cord Lg., ft. | Fasteners Included | Mounting Hole Dia. | Cannot Be Sold To | Each | |
8,000 | 80 dB @ 10 ft. | -20° to 120° | 6 3/4" | 3 1/4" | 1 3/4" | 120V AC | 6 | No | 3/16" | Canada | 0000000 | 0000000 |
Gas Leak Detectors for Hard-to-Reach Areas

Identify a variety of small leaks quickly and access hard-to-reach areas with the flexible probe. An audible signal increases in intensity the closer you get to the leak. Intrinsically safe for Class I, Divisions I and 2, Groups A, B, C, and D hazardous locations.
Product regulatations restrict sales to the listed areas.
Detection Trigger Point, ppm | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Methane (Natural Gas) | Propane | Hydrogen | Butane | Acetone | Methanol | Ammonia | Gasoline | Chlorine | Acetylene | Ethane | Ethylene | Hydrogen Sulfide | Batteries Included | Container Type | Cannot Be Sold To | Each | |
5 | 5 | 5 | 5 | 50 | 50 | 20 | 1 | 1 | 50 | 5 | 500 | 5 | Yes | Plastic Carrying Case | Outside North America | 0000000 | 0000000 |
Acoustic Imaging Gas Leak Detectors
Locate leaks up to 10 times faster than traditional leak-detecting methods. These detectors use 124 microphones to determine the precise location and size of leaks in compressed air and specific gas systems. The screen displays a high-resolution acoustic image that’s overlaid on a digital live shot of your facility to help you visualize the leak. It also displays analytics related to the leak, such as the rate and the potential cost savings of patching your system. You can capture the on-screen view through photos and video to review later. With a built-in flashlight, they remain accurate even in low-light spaces. Light enough to carry with one hand, you can bring these detectors on the go. A 650 ft. range means you can use them from one end of your facility to another, or to detect in hard-to-reach systems.
Connect the detector to your computer using Wi-Fi or the included USB cable to quickly transfer collected data.

Max. Working Distance, ft. | Measuring Range, kHz | Screen Size | Resolution Range | Data Connection Type | Wt., lbs. | Housing Material | Temp. Range, °F | Environmental Rating | Batteries Included | Container Type | Includes | Features | Each | |