About Door Closers
When replacing an existing closer, remove the cover and match the model number and/or mounting hole pattern to a closer in our offering. Or, use one of our closers and a universal mounting plate that matches most hole patterns.
If you are installing a new closer, choose one that works for your door width. Due to added resistance from wind, closers typically accommodate smaller exterior doors than interior doors.
There are three typical mounting positions for door closers; many of our closers are versatile and can be mounted in any of these positions. To determine opening direction, stand on the side of the door where the closer will be mounted. If the door opens towards you it opens in; opens away from you it opens out.
Door Mount, Opens In—Also known as regular arm mount, this position allows the door to open in toward the closer.
Door Mount, Opens Out—Also known as parallel arm mount, the arm lays parallel with the door in the closed position.
Frame Mount, Opens Out—Also known as top frame mount, this position is often used for exterior doors.
About Hinges
More
Clean Room Hinges
Keep environments free of contaminants—plastic bushings on these metal hinges prevent metal-to-metal contact that can release particles as hinges open and close.
Hinges with a quick-disconnect pin make it easy to remove your door from its frame. These hinges come in two parts—one for the door and one for the frame—that you join and take apart without any special tools.
For technical drawings and 3-D models, click on a part number.
Door Leaf | Frame Leaf | No. of Mounting Holes | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Ht. | Wd. | O'all Wd. | Leaf Thick. | Range of Motion | Pin Dia. | Pin Travel | Pin Material | Mounting Fasteners Included | Straight | Countersunk | Mounting Screw Size | Each | |
Quick-Disconnect Pin | |||||||||||||||
316 Stainless Steel—Dull | |||||||||||||||
3 1/16" | 1 1/4" | 5 1/16" | 7/8" | 1 11/32" | 0.079" | 120° | 1/4" | 3/8" | 316 Stainless Steel | No | 2 | 2 | M5 | 000000 | 000000 |
Hold-Closed Half-Mortise Concealed Cabinet Hinges
Spring tension pulls the door closed when it’s open less than 10° and keeps it closed without a catch or latch. Also known as European hinges, only one cutout (mortise) is needed for these hinges—mount the frame leaf to the inside cabinet wall and mount the door leaf into a recessed cutout (mortise) on the inside of the cabinet door. Once mounted, the hinges will be completely hidden from the outside when the door is closed. They are commonly found on washroom and kitchen cabinetry. All of these hinges have a nonremovable pin to deter tampering.
Nickel-plated steel hinges have mild corrosion resistance. These hinges also have a quick-release clip for easy door removal.
Hinges for overlay doors are for doors that cover their frame.
Hinges for half overlay doors are for doors that cover half of their frame.
For technical drawings and 3-D models, click on a part number.
For Cutout | Door Leaf | Frame Leaf | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dp. | Dia. | Ht. | Wd. | Ht. | Wd. | O'all Wd. | Range of Motion | Capacity, lbs. | Pin Material | Mounting Fasteners Included | No. of Mounting Holes | Mounting Hole Style | Features | Each | |
For Overlay Door—Hold Closed | |||||||||||||||
Nickel-Plated Steel—Dull | |||||||||||||||
1/2" | 1 3/8" | 2 1/4" | 1 7/16" | 2 1/4" | 3" | 4 1/2" | 120° | 15 | Steel | Yes | 4 | Countersunk | Quick-Release Clip | 000000 | 00000 |
For Half Overlay Door—Hold Closed | |||||||||||||||
Nickel-Plated Steel—Dull | |||||||||||||||
1/2" | 1 3/8" | 2 1/4" | 1 7/16" | 2 1/4" | 3" | 4 1/2" | 120° | 15 | Steel | Yes | 4 | Countersunk | Quick-Release Clip | 0000000 | 0000 |
High-Traffic Door Closers
For frequently used doors, these closers last twice as long as standard door closers. They can replace Yale, Dorma, Falcon, Stanley, Parker, and Cal-Royal models with the same mounting hole pattern. All meet ANSI A156.4 Grade 1 durability, strength, and performance standards for door controls. Closers that meet UL 10C for fire-rated doors meet positive pressure fire test standards.
To determine door swing direction, stand on the side of the door where it swings away from you. If it opens to the right, select a right closer; if it opens to the left, select a left closer. Reversible closers are for right or left door-swing directions.
Free-moving closers pull doors shut after you've opened them.
Hold-open closers hold doors open until you close them with a slight push or pull on the door.
For Door Wd. | Opening Direction | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Interior | Exterior | For Door Swing Direction | Opening/Closing Action | Door Mount | Frame Mount | Range of Motion | Mounting Hardware Included | Specifications Met | Choose a Finish | Each | |
LCN 4040XP | |||||||||||
24"-60" | 24"-48" | Reversible | Free Moving | Opens In, Opens Out | Opens Out | 120° | Yes | ANSI A156.4 Grade 1 UL 10C UL Listed | 0000000 | 0000000 | |
24"-60" | 24"-48" | Reversible | Hold Open | Opens In, Opens Out | Opens Out | 120° | Yes | ANSI A156.4 Grade 1 | 0000000 | 000000 |