About Sump, Water-Removal, Condensate, and Submersible Pumps
More
About Process Pumps
More
How to Determine Feet of Head
More
How to Prime Your Pump
More
Air-Powered Constant-Flow-Rate Pumps
Commonly called piston pumps, these are often used in high-pressure applications, such as hydrostatic testing of pipelines, tanks, and valves. Flow and outlet liquid pressure can be controlled by varying the air pressure. To calculate discharge liquid pressure, multiply the air pressure by the ratio shown in the table. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
For technical drawings and 3-D models, click on a part number.
Flow Rate, gpm | Air Pressure, psi | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 0 psi | @ 3,000 psi | Max. ft. of Head | Max. Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Air Consumption, scfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
86:1 Discharge Liquid to Inlet Air Pressure Ratio | |||||||||||||||
0.19 | 0.17 | 28,764 | 12,470 | 100 | 15 | 145 | 20 | 1/4 Female | 3/8 Female | 1/4 Female | 4 5/8" | 4" | 9" | 0000000 | 000000000 |
28:1 Discharge Liquid to Inlet Air Pressure Ratio | |||||||||||||||
0.58 | 0.13 | 9,365 | 4,060 | 100 | 15 | 145 | 20 | 1/4 Female | 3/8 Female | 1/4 Female | 4 5/8" | 4" | 9" | 0000000 | 00000000 |
11:1 Discharge Liquid to Inlet Air Pressure Ratio | |||||||||||||||
4.76 | __ | 3,679 | 1,595 | 100 | 15 | 145 | 45 | 1/2 Female | 1 Female | 1/2 Female | 10 3/4" | 7" | 12 1/4" | 0000000 | 00000000 |
High-Pressure Constant-Flow-Rate Pumps without Motor for Pressure Washing
Also known as plunger pumps, these can provide pressures up to 3,000 psi. Use them for washdowns, drain jetting, and other pressurized water-spraying applications. Connect them directly to an electric motor to alter the pump speed. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
For technical drawings and 3-D models, click on a part number.
Intake | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Pressure, psi | Temp. Range, °F | Required hp | For NEMA Frame | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Lg. | Wd. | Ht. | For Shaft Dia. | Each | |
2 | 2,000 | -20° to 160° | 2.7 | 56C | 3/8 | NPT | Female | 3/8 | NPT | Female | 8 1/4" | 8 5/8" | 6 1/2" | 5/8" | 00000000 | 0000000 |
3 | 3,000 | -20° to 140° | 6 1/5 | 182TC, 184TC | 1/2 | NPT | Female | 3/8 | NPT | Female | 9 1/2" | 9 1/4" | 7 1/8" | 1 1/8" | 00000000 | 000000 |
4 | 2,000 | -20° to 140° | 5 1/2 | 182TC, 184TC | 1/2 | NPT | Female | 3/8 | NPT | Female | 9 1/2" | 9 1/4" | 7 1/8" | 1 1/8" | 00000000 | 000000 |
Mobile Gasoline-Powered Sewage Water-Removal Pumps
Wheel these pumps to remote areas with no power. They can handle sewage water with thick sludge, silt, and debris up to 2" in diameter. Pumps are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Mount up to 20 feet above your liquid source. All have a pull-start engine. They are not submersible. These pumps cannot be sold to Canada due to import regulations.
Pump with a tank capacity of 1.6 gallons includes an electric starter that operates on a 12-volt battery (sold separately). It cannot be sold outside the United States because of energy efficiency requirements.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
Intake (NPT) | Discharge (NPT) | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 30 Ft. of Head | @ 60 Ft. of Head | @ 90 Ft. of Head | @ 100 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To, ft. | Temp. Range, °F | Horsepower | Pipe Size | Gender | Pipe Size | Gender | Ht. | Wd. | Lg. | Cannot Be Sold To | Each | |
1.6 gal. Tank Capacity | ||||||||||||||||||
530 | 335 | 110 | 20 | 103 | 2" | 20 | 40° to 180° | 13 hp | 4 | Female | 4 | Female | 31" | 38" | 45" | Outside United States | 00000000 | 000000000 |
1.7 gal. Tank Capacity | ||||||||||||||||||
460 | 275 | 75 | __ | 100 | 2" | 20 | 40° to 180° | 13 hp | 4 | Male | 4 | Male | 37" | 38" | 45" | Canada | 00000000 | 00000000 |
Gasoline-Powered Water-Removal Pumps
Fill the fuel tank with gasoline to remove water at sites without power. These pumps are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. They can be mounted up to 20 feet above your liquid source. All have a pull-start engine. Pumps are not submersible. They cannot be sold to the regions listed due to import and engine regulations.
Wheel kits (sold separately) include two 10" diameter wheels, hardware, and fasteners.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 20 Ft. of Head | @ 50 Ft. of Head | @ 70 Ft. of Head | @ 90 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Tank Cap., qt. | Temp. Range, °F | Horsepower | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Cannot Be Sold To | Each | |
220 | 180 | 140 | 100 | 125 | 1" | 20 ft. | 2.84 | 32° to 180° | 5 hp | 2 | NPT | Female | 2 | NPT | Female | 20" | 19 1/2" | 24" | Canada | 00000000 | 0000000 |
340 | 280 | 220 | 140 | 110 | 3/4" | 20 ft. | 5.5 | 40° to 180° | 8 hp | 3 | NPT | Female | 3 | NPT | Male | 23 1/2" | 22 1/2" | 31" | Canada | 00000000 | 00000000 |
Wheel Kit | 00000000 | Each | 0000000 |
Includes | Each | |
20 ft. of PVC Suction Hose (2 NPS Male × 2 NPS Female) 50 ft. of PVC Discharge Hose (2 NPS Male × 2 NPS Female) Suction Strainer Two Steel Adapters (2 NPS Male × 2 NPT Male) | 0000000 | 0000000 |
20 ft. of PVC Suction Hose (3 NPS Male × 3 NPS Female) 50 ft. of PVC Discharge Hose (3 NPS Male × 3 NPS Female) Suction Strainer Two Steel Adapters (3 NPS Male × 3 NPT Male) | 0000000 | 000000 |
Lightweight Plastic Gasoline-Powered Water-Removal Pumps
With a polypropylene housing, these pumps are about half the weight of other gasoline-powered pumps. Fill the fuel tank with gasoline to remove water at sites without power. Pumps are self-priming, which means that they create a suction force to draw liquid upward and fill the pump chamber. Mount up to 20 feet above your liquid source. They have a pull-start engine.
Wheel kits (sold separately) include two 10" diameter wheels, hardware, and fasteners.
Pumps cannot be sold to Canada due to import regulations.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 20 Ft. of Head | @ 50 Ft. of Head | @ 70 Ft. of Head | @ 90 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Tank Cap., qt. | Temp. Range, °F | Horsepower | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Cannot Be Sold To | Each | |
132 | 106 | 84 | 56 | 115 | 7/16" | 20 ft. | 2.28 | 40° to 130° | 5 hp | 2 | NPT | Female | 2 | NPT | Female | 19" | 16" | 13" | Canada | 000000 | 0000000 |
Includes | Each | |
20 ft. of PVC Suction Hose (2 NPS Male × 2 NPS Female) 50 ft. of PVC Discharge Hose (2 NPS Male × 2 NPS Female) Suction Strainer Two Steel Adapters (2 NPS Male × 2 NPT Male) | 0000000 | 0000000 |
Corrosion-Resistant Gasoline-Powered Water-Removal Pumps
Built with high-chromium stainless steel components, this pump stands up to salt water with up to 25% sand by volume and resists wear caused by abrasive particles. Fill the fuel tank with gasoline to remove water at sites without power. Pump is self-priming, which means it creates a suction force to draw liquid upward and fill the pump chamber. Mount up to 20 feet above your liquid source. Pump has a pull-start engine. It is not submersible. This pump cannot be sold to Canada due to import regulations.
Wheel kits (sold separately) include two 10" diameter wheels, hardware, and fasteners.
Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 20 Ft. of Head | @ 50 Ft. of Head | @ 70 Ft. of Head | @ 90 Ft. of Head | Max. Feet of Head, ft. | Max. Solids Dia. | Removes Water Down To | Tank Cap., qt. | Temp. Range, °F | Horsepower | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Cannot Be Sold To | Each | |
153 | 125 | 93 | 58 | 98 | 1/2" | 10 ft. | 3.8 | 40° to 160° | 5 hp | 2 | NPT | Female | 2 | NPT | Female | 20" | 20" | 25" | Canada | 0000000 | 000000000 |
Wheel Kit | 00000000 | Each | 0000000 |
Includes | Each | |
20 ft. of PVC Suction Hose (2 NPS Male × 2 NPS Female) 50 ft. of PVC Discharge Hose (2 NPS Male × 2 NPS Female) Suction Strainer Two Steel Adapters (2 NPS Male × 2 NPT Male) | 0000000 | 0000000 |