Selecting an Immersion Heater
More
Hanging Immersion Heaters for Water
Sized to fit drums, these heaters have a bracket to hook on the side of drums and in bung openings. They quickly and efficiently heat liquid through direct contact. An adjustable thermostat automatically turns the heater on when the temperature drops below the set temperature and off when it rises above the set temperature. Adjust the set temperature with the dial. Heaters are for use in metal containers; they should not be used in plastic containers.
Hang-on heaters have a bracket to hook on the side of containers.
Stainless steel heating elements have good corrosion resistance.
Note: Immerse the heating element in liquid up to at least the minimum coverage level to prevent heater failure.
Heating Element | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Container Cap., gal. | Wattage, W | Watt Density, W/sq. in. | Voltage | Electrical Phase | Current, A | Lg. | Wd. | Min. Coverage | Temp. Control Range, °F | Electrical Connection Type | NEMA Style | Cord Lg., ft. | Each | |
316 Stainless Steel Heating Element | ||||||||||||||
8 to 20 | 4,000 | 56 | 240V AC | Single | 16.7 | 26" | 13" | 4 1/2" | 60° to 250° | Plug | 6-30 | 6 | 00000000 | 0000000 |
8 to 20 | 6,000 | 65 | 240V AC | Single | 25 | 26" | 17" | 4 1/2" | 60° to 250° | Plug | 6-30 | 6 | 00000000 | 000000 |
Hanging Immersion Heaters for Chemical Solutions
Hook these heaters on the side of small drums and pails to quickly and efficiently heat liquid through direct contact. All are for use in metal containers; they should not be used in plastic containers. An adjustable thermostat automatically turns the heater on when the temperature drops below the set temperature and off when it rises above the set temperature. Adjust the set temperature with the dial. The heating element is 316 stainless steel for excellent resistance to harsh chemicals.
Note: Immerse the heating element in liquid up to at least the minimum coverage level to prevent heater failure.
Heating Element | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Container Cap., gal. | Wattage, W | Watt Density, W/sq. in. | Voltage | Electrical Phase | Current, A | Dia. | Wd. | Min. Coverage | Overall Lg. | Temperature Control Method | NEMA Style | Cord Lg., ft. | For Use With | Each | |
With Adjustable Thermostat (70° to 212° F) | |||||||||||||||
6" Lg. 316 Stainless Steel Heating Element | |||||||||||||||
1 to 5 | 500 | 25 | 120V AC | Single | 4.3 | __ | 1 3/8" | 4 1/2" | 9 3/4" | Dial | 5-15 | 6 | Ammonium Hydroxide (0-3%) Ammonium Hydroxide (3-6%) Deionized Water Ethylene Glycol Motor Oil Water | 0000000 | 0000000 |
1 to 5 | 1,100 | 56 | 120V AC | Single | 9.6 | __ | 1 3/8" | 4 1/2" | 9 3/4" | Dial | 5-15 | 6 | Ammonium Hydroxide (0-3%) Ammonium Hydroxide (3-6%) Deionized Water Motor Oil Water | 0000000 | 000000 |
20" Lg. 316 Stainless Steel Heating Element | |||||||||||||||
5 to 10 | 500 | 12 | 120V AC | Single | 4.3 | __ | 1 3/8" | 18 1/2" | 23 1/2" | Dial | 5-15 | 6 | Ammonium Hydroxide (0-3%) Ammonium Hydroxide (3-6%) Deionized Water Ethylene Glycol Motor Oil Nitric Acid (0-3%) Nitric Acid (3-6%) Phosphoric Acid (0-3%) Phosphoric Acid (3-6%) Sodium Hydroxide (0-3%) Sodium Hydroxide (3-6%) Water | 0000000 | 000000 |
5 to 10 | 1,100 | 25 | 120V AC | Single | 9.6 | __ | 1 3/8" | 18 1/2" | 23 1/2" | Dial | 5-15 | 6 | Ammonium Hydroxide (0-3%) Ammonium Hydroxide (3-6%) Deionized Water Ethylene Glycol Motor Oil Nitric Acid (0-3%) Nitric Acid (3-6%) Phosphoric Acid (0-3%) Phosphoric Acid (3-6%) Sodium Hydroxide (0-3%) Sodium Hydroxide (3-6%) Water | 0000000 | 000000 |
With Adjustable Thermostat (70° to 250° F) | |||||||||||||||
14" Lg. 316 Stainless Steel Heating Element | |||||||||||||||
5 to 10 | 1,500 | 19 | 120V AC | Single | 13 | 13" | __ | 5" | 14 1/2" | Dial | 5-15 | 6 | Ammonium Hydroxide (0-3%) Ammonium Hydroxide (3-6%) Deionized Water Ethylene Glycol Motor Oil Phosphoric Acid (0-3%) Phosphoric Acid (3-6%) Water | 00000000 | 000000 |
5 to 10 | 1,500 | 23 | 120V AC | Single | 13 | 10 1/2" | __ | 5" | 14 1/2" | Dial | 5-15 | 6 | Ammonium Hydroxide (0-3%) Ammonium Hydroxide (3-6%) Deionized Water Ethylene Glycol Motor Oil Water | 00000000 | 000000 |
5 to 10 | 1,500 | 34 | 120V AC | Single | 13 | 7" | __ | 5" | 14 1/2" | Dial | 5-15 | 6 | Ammonium Hydroxide (0-3%) Ammonium Hydroxide (3-6%) Deionized Water Motor Oil Water | 00000000 | 000000 |
Hanging Immersion Heaters for Coolant
Use the attached bracket to hook these heaters on the side of drums and in bung openings. They quickly and efficiently heat liquid through direct contact. With a lower watt density than heaters for water or chemicals, these heaters can heat coolant without creating hot spots or damaging the heating element. An adjustable thermostat automatically turns the heater on when the temperature drops below the set temperature and off when it rises above the set temperature. Adjust the set temperature with the dial. Heaters are for use in metal containers; they should not be used in plastic containers.
Hang-on heaters have a bracket to hook on the side of containers.
Stainless steel heating elements have good corrosion resistance.
Note: Immerse the heating element in liquid up to at least the minimum coverage level to prevent heater failure.
Heating Element | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Container Cap., gal. | Wattage, W | Watt Density, W/sq. in. | Voltage | Electrical Phase | Current, A | Lg. | Wd. | Min. Coverage | Temp. Control Range, °F | Electrical Connection Type | NEMA Style | Cord Lg., ft. | For Use With | Each | |
316 Stainless Steel Heating Element | |||||||||||||||
8 to 20 | 1,000 | 14 | 120V AC | Single | 8.3 | 26" | 13" | 4 1/2" | 60° to 250° | Plug | 5-15 | 6 | Ethylene Glycol, Water | 00000000 | 0000000 |
8 to 20 | 1,500 | 16 | 120V AC | Single | 12.5 | 26" | 17" | 4 1/2" | 60° to 250° | Plug | 5-15 | 6 | Ethylene Glycol, Water | 00000000 | 000000 |