About Choosing a Heater
More
About Infrared Heating
More
Mobile Large-Space Electric Heaters
Roll to heat large areas such as shops, garages, and warehouses. All have a built-in thermostat.
Heaters | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Housing | Receptacles | |||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temp. Change | Airflow, cfm | Wattage, W | Current, A | Cord Lg., ft. | Ht. | Wd. | Dp. | Material | Color | Temp. Setting, °F | Each | Each | ||
208V AC, Three Phase—Three-Prong Plug (CS8365C) | |||||||||||||||
51,100 | 6,810 cu. ft. @ 10° F 3,400 cu. ft. @ 20° F 2,270 cu. ft. @ 30° F 1,700 cu. ft. @ 40° F | 800 | 15,000 | 42 | 8 | 39" | 27" | 21" | Painted Steel | Yellow | 40° to 100° | 0000000 | 000000000 | 0000000 | 0000000 |
240V AC, Single Phase—Four-Prong Plug (NEMA 14-50) | |||||||||||||||
34,100 | 4,540 cu. ft. @ 10° F 2,270 cu. ft. @ 20° F 1,510 cu. ft. @ 30° F 1,130 cu. ft. @ 40° F | 800 | 10,000 | 42 | 8 | 39" | 27" | 21" | Painted Steel | Yellow | 40° to 100° | 0000000 | 00000000 | 000000 | 00 |
240V AC, Three Phase—Three-Prong Plug (CS8365C) | |||||||||||||||
51,100 | 6,810 cu. ft. @ 10° F 3,400 cu. ft. @ 20° F 2,270 cu. ft. @ 30° F 1,700 cu. ft. @ 40° F | 800 | 15,000 | 36 | 8 | 39" | 27" | 21" | Painted Steel | Yellow | 40° to 100° | 0000000 | 00000000 | 0000000 | 000000 |
480V AC, Three Phase—Four-Prong Plug (NEMA L16-30) | |||||||||||||||
51,100 | 6,810 cu. ft. @ 10° F 3,400 cu. ft. @ 20° F 2,270 cu. ft. @ 30° F 1,700 cu. ft. @ 40° F | 800 | 15,000 | 18 | 8 | 39" | 27" | 21" | Painted Steel | Yellow | 40° to 100° | 0000000 | 00000000 | 000000 | 00 |
480V AC, Three Phase—Three-Prong Plug (CS8165C) | |||||||||||||||
102,300 | 13,640 cu. ft. @ 10° F 6,820 cu. ft. @ 20° F 4,540 cu. ft. @ 30° F 3,410 cu. ft. @ 40° F | 1,100 | 30,000 | 36 | 8 | 39" | 27" | 23" | Painted Steel | Yellow | 40° to 100° | 0000000 | 00000000 | 0000000 | 000000 |
600V AC, Three Phase—Four-Prong Plug (NEMA L20-30) | |||||||||||||||
51,100 | 6,810 cu. ft. @ 10° F 3,400 cu. ft. @ 20° F 2,270 cu. ft. @ 30° F 1,700 cu. ft. @ 40° F | 800 | 15,000 | 15 | 8 | 39" | 25" | 21" | Painted Steel | Yellow | 40° to 100° | 00000000 | 00000000 | 0000000 | 00000 |
Portable Large-Space Gas Heaters
Built for big jobs, these are powerful space heaters.
All have a safety shut-off that cuts the gas supply if the flame goes out.
Propane heaters have a regulator with a NGO connection (the same connection between your gas grill and propane tank).
Heaters with a built-in thermostat allow you to control the temperature. On heaters controlled with a knob, turn the knob to adjust heat output.
Style A heaters use convection to circulate warm air. They have a pilot light ignition and do not require electricity.
Style B heaters have an electronic spark ignition and are good for drafty areas where a pilot light could be extinguished.
Overall | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Max. Fuel Consumption, cfh | Inlet Pipe Size | Inlet Thread Type | Inlet Gender | Tube Connection Type | Thread Type | For Tube OD | Current, A | Cord Lg. | Ht. | Wd. | Dp. | Housing Material | Each | |
Natural Gas Heaters with Knob | ||||||||||||||||||
Pilot Light Ignition | ||||||||||||||||||
A | 100,000 | 13,300 cu. ft. @ 10° F 6,600 cu. ft. @ 20° F 4,400 cu. ft. @ 30° F 3,300 cu. ft. @ 40° F | Not Rated | 100 | __ | __ | Male | 37° Flared | UN/UNF (JIC) | 1/2" | __ | __ | 19" | 16" | 16" | Steel | 0000000 | 0000000 |
Natural Gas Heaters with Thermostat (40° to 105° F) | ||||||||||||||||||
Electronic Spark Ignition—120V AC, Single Phase, Three-Prong Plug (NEMA 5-15) | ||||||||||||||||||
B | 155,000 | 20,660 cu. ft. @ 10° F 10,330 cu. ft. @ 20° F 6,880 cu. ft. @ 30° F 5,160 cu. ft. @ 40° F | 625 | 155 | 1/2 | NPT | Female | __ | __ | __ | 2.1 | 4" | 16" | 9" | 24" | Steel | 0000000 | 000000 |
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Required Propane Tank Size, lbs. | Max. Fuel Consumption, lbs./hr. | Inlet Thread Type | Current, A | Cord Lg. | Ht. | Wd. | Dp. | Housing Material | Includes | Each | |
Propane Heaters with Knob | |||||||||||||||
Pilot Light Ignition | |||||||||||||||
A | 80,000 | 10,660 cu. ft. @ 10° F 5,330 cu. ft. @ 20° F 3,550 cu. ft. @ 30° F 2,660 cu. ft. @ 40° F | Not Rated | 20 | 4 | NGO | __ | __ | 16" | 19" | 22" | Steel | 20-ft. Hose | 0000000 | 0000000 |
A | 200,000 | 26,660 cu. ft. @ 10° F 13,330 cu. ft. @ 20° F 8,880 cu. ft. @ 30° F 6,660 cu. ft. @ 40° F | Not Rated | 100 | 9.5 | NGO | __ | __ | 19" | 15" | 28" | Steel | 20-ft. Hose | 0000000 | 000000 |
Electronic Spark Ignition—120V AC, Single Phase, Three-Prong Plug (NEMA 5-15) | |||||||||||||||
B | 125,000 | 16,660 cu. ft. @ 10° F 8,330 cu. ft. @ 20° F 5,550 cu. ft. @ 30° F 4,160 cu. ft. @ 40° F | 400 | 100 | 6 | NGO | 0.7 | 10" | 16" | 12" | 26" | Steel | 15-ft. Hose | 0000000 | 000000 |
Propane Heaters with Thermostat (40° to 105° F) | |||||||||||||||
Electronic Spark Ignition—120V AC, Single Phase, Three-Prong Plug (NEMA 5-15) | |||||||||||||||
B | 170,000 | 22,660 cu. ft. @ 10° F 11,330 cu. ft. @ 20° F 7,550 cu. ft. @ 30° F 5,660 cu. ft. @ 40° F | 625 | 100 | 8 | NGO | 2.1 | 4" | 16" | 9" | 24" | Steel | 10-ft. Hose | 0000000 | 000000 |
B | 400,000 | 53,330 cu. ft. @ 10° F 26,660 cu. ft. @ 20° F 17,770 cu. ft. @ 30° F 13,330 cu. ft. @ 40° F | 1,580 | 500 | 18.5 | NGO | 1.5 | 4" | 22" | 13" | 35" | Steel | 10-ft. Hose | 0000000 | 000000 |
Mobile Large-Space Kerosene and Diesel Heaters
Roll these powerful space heaters to where you need heat for big jobs. All have a built-in thermostat.
The electronic spark ignition makes them good for drafty areas where a pilot light could be extinguished. The safety shut-off cuts the gas supply if the flame goes out.
Heaters | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Air Filters | ||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Max. Fuel Consumption, gph | Fuel Tank Capacity, gal. | Current, A | Cord Lg. | Ht. | Wd. | Dp. | Housing Material | Temperature Setting, °F | Each | Each | ||
Electronic Spark Ignition—120V AC, Single Phase, Three-Prong Plug (NEMA 5-15) | |||||||||||||||
125,000 | 16,660 cu. ft. @ 10° F 8,330 cu. ft. @ 20° F 5,550 cu. ft. @ 30° F 4,160 cu. ft. @ 40° F | 520 | 1 | 10 | 2.5 | 4" | 25" | 23" | 38" | Steel | 40° to 105° | 000000 | 0000000 | 0000000 | 000000 |
175,000 | 23,330 cu. ft. @ 10° F 11,660 cu. ft. @ 20° F 7,770 cu. ft. @ 30° F 5,830 cu. ft. @ 40° F | 600 | 1.3 | 13 | 3.2 | 4" | 27" | 24" | 44" | Steel | 40° to 105° | 0000000 | 000000 | 0000000 | 00000 |
650,000 | 86,660 cu. ft. @ 10° F 43,330 cu. ft. @ 20° F 28,880 cu. ft. @ 30° F 21,660 cu. ft. @ 40° F | 3,600 | 5 | 50 | 7.1 | 4" | 49" | 31" | 70" | Steel | 40° to 105° | 0000000 | 00000000 | 000000 | 00 |
Portable Large-Space Kerosene and Diesel Heaters
Built for big jobs, this is a powerful space heater. It has a built-in thermostat.
The electronic spark ignition makes it good for drafty areas where a pilot light could be extinguished. The safety shut-off cuts the gas supply if the flame goes out.
Heaters | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Air Filters | ||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Max. Fuel Consumption, gph | Fuel Tank Capacity, gal. | Current, A | Cord Lg. | Ht. | Wd. | Dp. | Housing Material | Temperature Setting, °F | Each | Each | ||
Electronic Spark Ignition—120V AC, Single Phase, Three-Prong Plug (NEMA 5-15) | |||||||||||||||
75,000 | 10,000 cu. ft. @ 10° F 5,000 cu. ft. @ 20° F 3,330 cu. ft. @ 30° F 2,500 cu. ft. @ 40° F | 265 | 0.6 | 5 | 1.6 | 4" | 17" | 12" | 32" | Steel | 40° to 105° | 000000 | 0000000 | 0000000 | 000000 |
Portable Small-Space Electric Heaters
Carry these heaters to offices, workstations, and other small spaces. All have a built-in thermostat.
Plastic heater shuts off if tipped over or airflow is obstructed.
19,100 Btu/hr. heater has a bracket you can use as a stand or to mount to the wall or ceiling. When operating at 208 volts AC, maximum area heated and heat output are reduced by 25%.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Wattage, W | Current, A | Cord Lg., ft. | Ht. | Wd. | Dp. | Housing Material | Temperature Setting, °F | Each | |
120V AC, Single Phase—Two-Prong Plug (NEMA 1-15) | ||||||||||||
5,100 | __ | 25 | 1,500 | 12.5 | 6 | 9" | 9" | 5" | Plastic | 65° to 85° | 0000000 | 000000 |
120V AC, Single Phase—Three-Prong Plug (NEMA 5-15) | ||||||||||||
5,100 | 750 cu. ft. @ 10° F 370 cu. ft. @ 20° F 250 cu. ft. @ 30° F 190 cu. ft. @ 40° F | 120 | 1,500 | 12.5 | 6 | 11" | 9" | 13" | Steel | 0° to 80° | 0000000 | 000000 |
208V AC/240V AC, Single Phase—Three-Prong Plug (NEMA 6-30) | ||||||||||||
19,100 | 2,540 cu. ft. @ 10° F 1,270 cu. ft. @ 20° F 840 cu. ft. @ 30° F 630 cu. ft. @ 40° F | 260 | 5,600 | 23.4 | 6 | 18" | 14" | 12" | Steel | 35° to 85° | 0000000 | 000000 |
Direct Long-Range Mobile Electric Heaters
NEMA L15-20 Plug | NEMA L15-30 Plug | |
NEMA L16-20 Plug | NEMA L20-30 Plug |
Roll these heaters to warm people at large worksites.
For permanent installation, add a thermostat (sold separately). A relay (not included) is required between the heater and thermostat.
Heaters | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Wall-Mount Thermostats | ||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Wattage, W | Current, A | Cord Lg., ft. | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Each | Each | ||
240V AC, Three Phase—Four-Prong Plug (NEMA L15-20) | |||||||||||||
14,900 | 430 sq. ft. @ 10° F 210 sq. ft. @ 20° F 140 sq. ft. @ 30° F 110 sq. ft. @ 40° F | 4,300 | 10.4 | 8 | 38" | 20" | 17" | Aluminum | No | 0000000 | 000000000 | 0000000 | 0000000 |
240V AC, Three Phase—Four-Prong Plug (NEMA L15-30) | |||||||||||||
32,400 | 950 sq. ft. @ 10° F 470 sq. ft. @ 20° F 320 sq. ft. @ 30° F 240 sq. ft. @ 40° F | 9,500 | 22.9 | 8 | 53" | 20" | 17" | Aluminum | No | 0000000 | 00000000 | 0000000 | 000000 |
480V AC, Three Phase—Four-Prong Plug (NEMA L16-20) | |||||||||||||
14,900 | 430 sq. ft. @ 10° F 210 sq. ft. @ 20° F 140 sq. ft. @ 30° F 110 sq. ft. @ 40° F | 4,300 | 5.2 | 8 | 38" | 20" | 17" | Aluminum | No | 0000000 | 00000000 | 0000000 | 000000 |
32,400 | 950 sq. ft. @ 10° F 470 sq. ft. @ 20° F 320 sq. ft. @ 30° F 240 sq. ft. @ 40° F | 9,500 | 11.4 | 8 | 53" | 20" | 17" | Aluminum | No | 0000000 | 00000000 | 0000000 | 000000 |
600V AC, Three Phase—Four-Prong Plug (NEMA L20-30) | |||||||||||||
14,900 | 430 sq. ft. @ 10° F 210 sq. ft. @ 20° F 140 sq. ft. @ 30° F 110 sq. ft. @ 40° F | 4,300 | 4.3 | 8 | 38" | 20" | 17" | Aluminum | No | 00000000 | 000000 | 0000000 | 000000 |
32,400 | 950 sq. ft. @ 10° F 470 sq. ft. @ 20° F 320 sq. ft. @ 30° F 240 sq. ft. @ 40° F | 9,500 | 9.5 | 8 | 53" | 20" | 17" | Aluminum | No | 00000000 | 00000000 | 0000000 | 000000 |
Direct Long-Range Portable Gas Heaters
Place at large worksites and other well-ventilated areas. These heaters have a safety shut-off that cuts the gas supply if the flame goes out.
Propane heaters with a regulator have a NGO connection (the same connection between your gas grill and propane tank).
Barrier ring guard kits keep you from accidentally bumping into heaters. They are often used in areas with high foot traffic.
Heaters | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Overall | Replacement Thermocouples | |||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Max. Fuel Consumption, cfh | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Dia. | Housing Material | For Use Outdoors | Each | Each | ||
Pilot Light Ignition | |||||||||||||||
125,000 | 3,660 sq. ft. @ 10° F 1,830 sq. ft. @ 20° F 1,220 sq. ft. @ 30° F 910 sq. ft. @ 40° F | 125 | 1/2 | NPT | Female | 35" | 15" | 15" | __ | Steel | Yes | 0000000 | 0000000 | 0000000 | 000000 |
212,000 | 6,210 sq. ft. @ 10° F 3,100 sq. ft. @ 20° F 2,070 sq. ft. @ 30° F 1,550 sq. ft. @ 40° F | 215 | 1/2 | NPT | Female | 50" | __ | __ | 18" | Steel | No | 0000000 | 000000 | 0000000 | 00000 |
Heaters | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Overall | Replacement Thermocouples | |||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Required Propane Tank Size, lbs. | Max. Fuel Consumption, lbs./hr. | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Dia. | Housing Material | For Use Outdoors | Includes | Each | Each | ||
Pilot Light Ignition | |||||||||||||||||
35,000 | 1,020 sq. ft. @ 10° F 510 sq. ft. @ 20° F 340 sq. ft. @ 30° F 260 sq. ft. @ 40° F | 20 | 2 | __ | NGO | __ | 35" | 10" | 13" | __ | Steel | Yes | 20-ft. Hose with Regulator | 000000 | 0000000 | 0000000 | 000000 |
125,000 | 3,660 sq. ft. @ 10° F 1,830 sq. ft. @ 20° F 1,220 sq. ft. @ 30° F 910 sq. ft. @ 40° F | 40 | 6 | __ | NGO | __ | 35" | 15" | 15" | __ | Steel | Yes | 20-ft. Hose with Regulator | 0000000 | 000000 | 0000000 | 00000 |
200,000 | 5,860 cu. ft. @ 10° F 2,930 cu. ft. @ 20° F 1,950 cu. ft. @ 30° F 1,460 cu. ft. @ 40° F | 100 | 9 | 1/2 | NPT | Female | 50" | __ | __ | 18" | Steel | No | __ | 0000000 | 000000 | 0000000 | 00000 |
For Heat Output, Btu/hr. | Each | |
200,000 212,000 | 0000000 | 0000000 |
For Heat Output, Btu/hr. | Each | |
125,000 | 0000000 | 00000 |
For Heat Output, Btu/hr. | Each | |
125,000 | 0000000 | 00000 |
For Heat Output, Btu/hr. | Each | |
125,000 | 0000000 | 00000 |
Electric Desk Heaters
Stay warm at a desk, counter, or table. The housings for these heaters maintain a low temperature, so they’re safe to touch and minimize heat damage to surfaces if the heater tips over. These heaters will also automatically shut off if they tip over or overheat.
Control them with the on-off switch or a thermostat. Freestanding heaters have a built-in thermostat. Wall-mount/freestanding heaters have a built-in floor stand and can mount under desks. You can add an optional thermostat (sold separately).
Overall | Housing | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Wattage, W | Current, A | Cord Lg., ft. | Ht. | Wd. | Dp. | Material | Color | Control Type | Features | Each | |
120V AC, Single Phase, Two-Prong Plug (NEMA 1-15) | |||||||||||||
5,120 | 150 sq. ft. @ 10° F 75 sq. ft. @ 20° F 50 sq. ft. @ 30° F 37 sq. ft. @ 40° F | 750 | 12.5 | 6 | 10 3/4" | 7 1/2" | 5 1/2" | Plastic | Silver | Knob, Thermostat | Safe-Touch Housing, Automatic Shut-Off | 0000000 | 000000 |
Heaters | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Housing | Thermostats | |||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Wattage, W | Current, A | Cord Lg., ft. | Ht. | Wd. | Dp. | Material | Color | Control Type | Features | Each | Each | ||
120V AC, Single Phase, Three-Prong Plug (NEMA 5-15) | |||||||||||||||
500 | 10 sq. ft. @ 10° F 7 sq. ft. @ 20° F 5 sq. ft. @ 30° F 4 sq. ft. @ 40° F | 170 | 1.5 | 7 | 15" | 22" | 1" | Painted Steel | White | On-Off Switch, Thermostat | Safe-Touch Housing, Automatic Shut-Off | 0000000 | 0000000 | 0000000 | 0000000 |
Direct Short-Range Portable Electric Heaters
Move these heaters to worksites, loading docks, and other cold spots to warm people in indoor and sheltered outdoor areas.
For permanent installation, add a thermostat (sold separately). For 480V AC heater, a relay (not included) is required between the heater and thermostat.
Heaters | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Wall-Mount Thermostats | ||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Wattage, W | Current, A | Cord Lg., ft. | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Each | Each | ||
120V AC, Single Phase—Three-Prong Plug (NEMA 5-15) | |||||||||||||
4,900 | 140 sq. ft. @ 10° F 70 sq. ft. @ 20° F 50 sq. ft. @ 30° F 40 sq. ft. @ 40° F | 1,450 | 12.1 | 15 | 29" | 12" | 14" | Aluminum | Yes | 0000000 | 0000000 | 0000000 | 0000000 |
208V AC, Single Phase—Three-Prong Plug (NEMA L6-20) | |||||||||||||
10,700 | 310 sq. ft. @ 10° F 160 sq. ft. @ 20° F 100 sq. ft. @ 30° F 80 sq. ft. @ 40° F | 3,100 | 15.1 | 8 | 50" | 12" | 14" | Aluminum | Yes | 0000000 | 00000000 | 0000000 | 000000 |
240V AC, Single Phase—Three-Prong Plug (NEMA L6-20) | |||||||||||||
10,700 | 310 sq. ft. @ 10° F 160 sq. ft. @ 20° F 100 sq. ft. @ 30° F 80 sq. ft. @ 40° F | 3,100 | 13.1 | 8 | 50" | 12" | 14" | Aluminum | Yes | 0000000 | 00000000 | 0000000 | 000000 |
480V AC, Single Phase—Three-Prong Plug (NEMA L8-20) | |||||||||||||
10,700 | 310 sq. ft. @ 10° F 160 sq. ft. @ 20° F 100 sq. ft. @ 30° F 80 sq. ft. @ 40° F | 3,100 | 6.6 | 8 | 50" | 12" | 14" | Aluminum | Yes | 0000000 | 00000000 | 0000000 | 000000 |
Direct Short-Range Gas Heaters
Built for outdoor use, these heaters warm people at worksites and other cold spots without access to electricity. Connect heaters to a propane tank and light with a match. They have a regulator with a NGO connection (the same connection between your gas grill and propane tank). All have a safety shut-off that cuts the gas supply if the flame goes out.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Burners | Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Required Propane Tank Size, lbs. | Max. Fuel Consumption, lbs./hr. | Inlet Thread Type | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Each | |
Propane Heaters | ||||||||||||
External Lighter Ignition | ||||||||||||
1 | 15,000 | 440 sq. ft. @ 10° F 220 sq. ft. @ 20° F 150 sq. ft. @ 30° F 110 sq. ft. @ 40° F | 20 | 1 | NGO | 13" | 10" | 8" | Steel | Yes | 000000 | 000000 |
2 | 30,000 | 880 sq. ft. @ 10° F 440 sq. ft. @ 20° F 290 sq. ft. @ 30° F 220 sq. ft. @ 40° F | 20 | 1.5 | NGO | 16" | 17" | 7" | Steel | Yes | 000000 | 000000 |
3 | 45,000 | 1,320 sq. ft. @ 10° F 660 sq. ft. @ 20° F 450 sq. ft. @ 30° F 330 sq. ft. @ 40° F | 20 | 2 | NGO | 12" | 27" | 6" | Steel | Yes | 0000000 | 000000 |
High-Volume Low-Heat Air Blowers
Combine high-volume airflow with low-heat output for warming and drying. These blowers tilt to direct airflow.
Noise-reducing blowers are quieter than all of the other blowers.
Blowers with a fixed airflow rate are portable, so you can carry them from job to job.
UL and C-UL Listed blowers meet U.S. and Canadian safety standards.
Use the optional wye adapters to direct air into two hoses for more complete drying.
O'all | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Setting, °F | Airflow, cfm | Tip Dia. | Nozzle Lg. | Lg. | Wd. | Ht. | Ht. Adjustability | Wattage, W | Heating Element Material | Housing Material | Plug Type | NEMA Style | Features | Specifications Met | Each | ||
120V AC | |||||||||||||||||
Adjustable Airflow | |||||||||||||||||
C | 100°, 120° | 106-230 | 2 1/4" | 16" | 30" | 9" | 40" | Fixed | 1,800 | Mica | Aluminum | Three Prong | 5-15 | __ | C-UL Listed UL Listed | 0000000 | 0000000 |
D | 100°, 120° | 106-230 | 2 1/4" | 16" | 30" | 9" | 52" | Adjustable | 1,800 | Mica | Aluminum | Three Prong | 5-15 | __ | C-UL Listed UL Listed | 0000000 | 000000 |
Fixed Airflow | |||||||||||||||||
E | 110°, 130° | 175 | 2 1/4" | 16" | 26" | 9" | 52" | Adjustable | 1,800 | Mica | Aluminum | Three Prong | 5-15 | Handle, Noise Reducing | __ | 0000000 | 000000 |
Mobile Heat Lamps
Roll these lamps to your work surface and position the head anywhere along the stand, 18”-30” from what you want to heat. Use for spot-drying paint, adhesive, and other surface coatings and fillers. They’re also known as infrared and radiant heaters.
Adjustable-temperature lamp lets you regulate heat using three switch controls and up to seven bulbs (not included). Lamp is not for use with water-based primers and paint.
Fixed-temperature lamps have a head that rotates for horizontal or vertical positioning.
Note: Do not use in hazardous locations, such as enclosed areas exposed to fumes.
For Bulb | Stand O'all | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dia. | Dp. | Duty Cycle | Type | Base Size | Base Type | Max. Wattage per Bulb, W | Bulbs Included | No. of Bulbs Required | Ht., ft. | Wd. | Dp. | Housing Material | Plug Type | NEMA Style | Each | |
120V AC, 120V DC—Single Phase | ||||||||||||||||
18" | 11" | Intermittent | Infrared | Medium (Standard Household) | Screw In | 250 | No | 7 | 6 | 26 1/2" | 30" | Steel | Three Prong | 5-15 | 000000 | 0000000 |
Fixed Temperature | NEMA 5-15 |
NEMA 6-20 |
Heat Lamps | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Stand O'all | Replacement Heating Elements | ||||||||||||||
Wattage, W | Lg. | Wd. | Dp. | Duty Cycle | Operating Temp. Range, °F | Ht., ft. | Wd. | Dp. | Housing Material | Plug Type | NEMA Style | Each | Each | ||
120V AC, 120V DC—Single Phase | |||||||||||||||
1,500 | 36" | 3 1/2" | 3 1/2" | Intermittent | 1125° to 1325° | 6 | 26 1/2" | 30" | Steel | Three Prong | 5-15 | 00000000 | 0000000 | 0000000 | 0000000 |
2,000 | 36" | 3 1/2" | 3 1/2" | Intermittent | 1125° to 1325° | 6 | 26 1/2" | 30" | Steel | Three Prong | 5-15 | 0000000 | 000000 | 0000000 | 000000 |
240V AC, 240V DC—Single Phase | |||||||||||||||
1,500 | 36" | 3 1/2" | 3 1/2" | Intermittent | 1125° to 1325° | 6 | 26 1/2" | 30" | Steel | Three Prong | 6-20 | 00000000 | 000000 | 0000000 | 000000 |
2,000 | 36" | 3 1/2" | 3 1/2" | Intermittent | 1125° to 1325° | 6 | 26 1/2" | 30" | Steel | Three Prong | 6-20 | 0000000 | 000000 | 0000000 | 000000 |
Hand-Held Heat Lamps
Position these lamps at any angle to heat, dry, soften, or defrost. They’re also known as infrared and radiant heaters.
Note: Do not use in hazardous locations, such as enclosed areas exposed to fumes.
O'all | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Operating Temp. | Duty Cycle | On/Off Time | Max. Wattage per Bulb, W | Bulbs Included | Rated Bulb Life, hrs. | Dia. | Ht. | Dp. | Housing Material | Reflector Material | Plug Type | Includes | Features | Each | |
Heat Lamps—120V AC (Single Phase) | |||||||||||||||
182° F @ 12" 363° F @ 5" | Intermittent | 30 Minutes On, 20 Minutes Off | 600 | Yes | 75 | 4" | 11 1/2" | 4 1/2" | Plastic | Aluminum | Two Prong | Protective Dark Glasses | Swivel Handle | 0000000 | 0000000 |