Heat Exchangers
Also known as shell and tube heat exchangers, these transfer heat using liquid or steam that flows through the shell to heat or cool liquid in the tubes. They’re commonly used in refrigeration and engine cooling systems. Btu/hr. cooling capacity is based on cooling 180° F process water with 85° F water and a 10 psi pressure difference.
Heat exchangers with a 316 stainless steel shell and tubes are the most corrosion resistant.
Heat exchangers with baffled tubes direct liquid to make four passes through the tubes for more efficient heat transfer than other heat exchangers.
ASME BPVC VIII.1 heat exchangers meet the ASME Boiler and Pressure Vessel Code (BPVC) for construction of pressure vessels.
For technical drawings and 3-D models, click on a part number.
Shell-Side | Tube-Side | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heating/Cooling Cap., Btu/hr. | Surface Area, sq. ft. | No. of Passes | Min. Temp., °F | Max. Temp., °F | Pipe Size | Flow Cap., gpm | Max. Pressure, psi | Pipe Size | Flow Cap., gpm | Max. Pressure, psi | Lg. | Head Dia. | Each | |
Brass Shell and Baffled Copper Tube | ||||||||||||||
130,000 | 2.4 | 4 | -20° | 300° | 1 | 24 | 300 | 3/4 | 12 | 150 | 10 7/8" | 4 3/16" | 00000000 | 0000000 |
195,000 | 4.3 | 4 | -20° | 300° | 1 | 24 | 300 | 3/4 | 12 | 150 | 16 7/8" | 4 3/16" | 00000000 | 00000000 |
280,000 | 7.4 | 4 | -20° | 300° | 1 | 24 | 300 | 3/4 | 12 | 150 | 26 7/8" | 4 3/16" | 00000000 | 00000000 |
350,000 | 9.1 | 4 | -20° | 300° | 1 1/2 | 60 | 300 | 1 | 30 | 150 | 18 1/8" | 6 1/2" | 00000000 | 00000000 |
560,000 | 15.7 | 4 | -20° | 300° | 1 1/2 | 60 | 300 | 1 | 30 | 150 | 28 1/8" | 6 1/2" | 00000000 | 00000000 |
890,000 | 23 | 4 | -20° | 300° | 2 | 73 | 300 | 1 1/2 | 57 | 150 | 29" | 7 1/2" | 00000000 | 00000000 |
1,115,000 | 34 | 4 | -20° | 300° | 2 | 73 | 300 | 1 1/2 | 57 | 150 | 41" | 7 1/2" | 00000000 | 00000000 |
1,585,000 | 41 | 4 | -20° | 300° | 3 | 140 | 300 | 2 | 104 | 150 | 30 3/8" | 9 3/4" | 00000000 | 00000000 |
2,000,000 | 62 | 4 | -20° | 300° | 3 | 140 | 300 | 2 | 105 | 150 | 42 3/8" | 9 3/4" | 00000000 | 00000000 |
Steel Shell and Baffled Copper Tube | ||||||||||||||
195,000 | 4.3 | 4 | -20° | 300° | 1 | 22 | 300 | 3/4 | 12 | 150 | 17" | 4 1/2" | 0000000 | 00000000 |
280,000 | 7.4 | 4 | -20° | 300° | 1 | 30 | 300 | 3/4 | 12 | 150 | 27" | 4 1/2" | 0000000 | 00000000 |
350,000 | 9.1 | 4 | -20° | 300° | 1 1/2 | 32 | 300 | 1 | 30 | 150 | 18 11/16" | 6 3/4" | 0000000 | 00000000 |
560,000 | 15.7 | 4 | -20° | 300° | 1 1/2 | 43 | 300 | 1 | 30 | 150 | 28 11/16" | 6 3/4" | 0000000 | 00000000 |
890,000 | 23 | 4 | -20° | 300° | 2 | 51 | 300 | 1 1/2 | 57 | 150 | 29" | 7 3/4" | 0000000 | 00000000 |
1,115,000 | 34 | 4 | -20° | 300° | 2 | 103 | 300 | 1 1/2 | 57 | 150 | 41" | 7 3/4" | 0000000 | 00000000 |
1,585,000 | 41 | 4 | -20° | 300° | 3 | 103 | 300 | 2 | 104 | 150 | 30 1/2" | 10 1/2" | 0000000 | 00000000 |
2,000,000 | 62 | 4 | -20° | 300° | 3 | 103 | 300 | 2 | 105 | 150 | 42 1/2" | 10 1/2" | 0000000 | 00000000 |
Steel Shell and Copper Tube | ||||||||||||||
Not Rated | 15 | 2 | Not Rated | 400° | 2 1/2 (Inlet); 1 1/4 (Outlet) | 38 | 100 | 1 1/4 | 38 | 100 | 28 5/8" | 6" | 0000000 | 00000000 |
316 Stainless Steel Shell and Baffled 316 Stainless Steel Tube | ||||||||||||||
130,000 | 2.4 | 4 | -20° | 450° | 1 | 32 | 225 | 3/4 | 12 | 150 | 10 3/8" | 4 3/16" | 00000000 | 00000000 |
195,000 | 4.3 | 4 | -20° | 450° | 1 | 32 | 225 | 3/4 | 12 | 150 | 16 3/8" | 4 3/16" | 00000000 | 00000000 |
280,000 | 7.4 | 4 | -20° | 450° | 1 | 32 | 225 | 3/4 | 12 | 150 | 26 3/8" | 4 3/16" | 00000000 | 00000000 |
350,000 | 9.1 | 4 | -20° | 450° | 1 1/2 | 76 | 225 | 1 | 30 | 150 | 17 13/16" | 6 1/2" | 00000000 | 00000000 |
560,000 | 15.7 | 4 | -20° | 450° | 1 1/2 | 76 | 225 | 1 | 30 | 150 | 27 13/16" | 6 1/2" | 00000000 | 00000000 |
890,000 | 23 | 4 | -20° | 450° | 2 | 126 | 225 | 1 1/2 | 57 | 150 | 28 1/8" | 7 1/2" | 00000000 | 00000000 |
1,115,000 | 34 | 4 | -20° | 450° | 2 | 126 | 225 | 1 1/2 | 57 | 150 | 40 1/8" | 7 1/2" | 00000000 | 00000000 |
1,585,000 | 41 | 4 | -20° | 450° | 3 | 220 | 225 | 2 | 104 | 150 | 28" | 9 3/4" | 00000000 | 00000000 |
2,000,000 | 62 | 4 | -20° | 450° | 3 | 220 | 225 | 2 | 105 | 150 | 40" | 9 3/4" | 00000000 | 00000000 |
Shell-Side | Tube-Side | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heating/Cooling Cap., Btu/hr. | Surface Area, sq. ft. | No. of Passes | Min. Temp., °F | Max. Temp., °F | Pipe Size | Flow Cap., gpm | Max. Pressure, psi | Pipe Size | Flow Cap., gpm | Max. Pressure, psi | Lg. | Head Dia. | Each | |
150,000 | 4.5 | 2 | -20° | 375° | 2 (Inlet); 1 (Outlet) | 44 | 150 | 1 1/2 | 44 | 150 | 28 1/2" | 7 1/4" | 0000000 | 000000000 |
420,000 | 6.8 | 2 | -20° | 375° | 2 (Inlet); 1 (Outlet) | 44 | 150 | 1 1/2 | 44 | 150 | 40 1/2" | 7 1/4" | 0000000 | 00000000 |
720,000 | 9.2 | 2 | -20° | 375° | 3 (Inlet); 1 (Outlet) | 44 | 150 | 1 1/2 | 44 | 150 | 52 1/2" | 7 1/4" | 0000000 | 00000000 |
1,350,000 | 17.4 | 2 | -20° | 375° | 2 1/2 (Inlet); 1 (Outlet) | 175 | 150 | 2 | 175 | 150 | 53 1/4" | 10 1/2" | 0000000 | 00000000 |
Shell-Side | Tube-Side | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heating/Cooling Cap. | Surface Area, sq. ft. | No. of Passes | Max. Temp., °F | Pipe Size | Flow Cap., gpm | Max. Pressure, psi | Pipe Size | Flow Cap., gpm | Max. Pressure, psi | Lg. | Head Dia. | Each | |
Not Rated | 30.2 | 2 | 400° | 4 (Inlet); 1 1/2 (Outlet) | 100 | 100 | 2 | 100 | 100 | 39 3/4" | 8 1/8" | 0000000 | 000000000 |
Not Rated | 38.8 | 2 | 400° | 4 (Inlet); 1 1/2 (Outlet) | 100 | 100 | 2 | 100 | 100 | 51 3/4" | 8 1/8" | 0000000 | 00000000 |
Not Rated | 72.4 | 2 | 400° | 6 (Inlet); 2 (Outlet) | 180 | 100 | 2 1/2 | 180 | 100 | 53" | 10 1/8" | 0000000 | 00000000 |
High-Efficiency Heat Exchangers
Stacked, corrugated plates maximize contact with liquid or steam flowing through these brazed plate heat exchangers for faster heat transfer than shell and tube heat exchangers. Plates are brazed in a vacuum furnace to ensure 100% sealed construction.
Copper-brazed heat exchangers have a Btu/hr. cooling capacity based on cooling water from 120° to 100° F using 70° F water.
ASME BPVC VIII.1 copper-brazed heat exchangers have a Btu/hr. cooling capacity based on cooling 100 SSU oil to 125° F using 85° F water.
Nickel-brazed heat exchangers have a Btu/hr. cooling capacity based on cooling oil from 140° to 120° F using 70° F water.
ASME BPVC VIII.1 heat exchangers meet the ASME Boiler and Pressure Vessel Code (BPVC) for construction of pressure vessels.
For technical drawings and 3-D models, click on a part number.
Overall | Mounting Hole | Mounting Stud | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heating/Cooling Cap., Btu/hr. | Surface Area, sq. ft. | Temp. Range, °F | Pipe Size | Thread Type | Gender | Flow Cap., gpm | Max. Pressure, psi | Ht. | Wd. | Dp. | No. of | Dia. | No. of | Thread Size | Lg. | Each | |
Heat Exchangers | |||||||||||||||||
Copper-Brazed 316 Stainless Steel Plate | |||||||||||||||||
69,000 | 2.2 | -320° to 350° | 3/4 | NPT | Male | 7 | 450 | 9 1/8" | 3 1/2" | 2 5/8" | __ | __ | 2 | M8 | 20mm | 00000000 | 0000000 |
80,000 | 3 | -320° to 350° | 1 | NPT | Male | 8 | 450 | 13 3/16" | 5" | 1 1/4" | __ | __ | 4 | M10 | 20mm | 00000000 | 000000 |
185,000 | 6.8 | -320° to 350° | 1 | NPT | Male | 19 | 450 | 13 3/16" | 5" | 2" | __ | __ | 4 | M8 | 20mm | 00000000 | 000000 |
390,000 | 14.3 | -320° to 350° | 1 | NPT | Male | 40 | 450 | 13 3/16" | 5" | 4" | __ | __ | 4 | M10 | 20mm | 00000000 | 000000 |
570,000 | 21.9 | -320° to 350° | 1 1/4 | NPT | Male | 58 | 450 | 13 3/16" | 5" | 5 3/4" | __ | __ | 4 | M8 | 20mm | 00000000 | 00000000 |
998,000 | 36.8 | -320° to 350° | 2 | NPT | Male | 105 | 300 | 20 5/16" | 9 13/16" | 3.06" | __ | __ | 4 | 1/2"-13 | 1 1/2" | 00000000 | 00000000 |
1,710,000 | 63 | -320° to 350° | 2 | NPT | Male | 170 | 300 | 20 5/16" | 9 13/16" | 4.86" | __ | __ | 4 | 1/2"-13 | 1 1/2" | 00000000 | 00000000 |
Nickel-Brazed 316 Stainless Steel Plate | |||||||||||||||||
16,000 | 3.1 | -320° to 390° | 1 | NPT | Male | 4 | 360 | 13 3/16" | 4 7/8" | 2 3/16" | __ | __ | 4 | M10 | 13/16" | 0000000 | 000000 |
37,000 | 6.8 | -320° to 390° | 1 | NPT | Male | 9 | 360 | 13 3/16" | 4 7/8" | 3 1/16" | __ | __ | 4 | M10 | 13/16" | 0000000 | 00000000 |
56,000 | 10.6 | -320° to 390° | 1 | NPT | Male | 13 | 360 | 13 3/16" | 4 7/8" | 4" | __ | __ | 4 | M10 | 13/16" | 0000000 | 00000000 |
74,000 | 14.3 | -320° to 390° | 1 | NPT | Male | 18 | 360 | 13 3/16" | 4 7/8" | 4 7/8" | __ | __ | 4 | M10 | 13/16" | 0000000 | 00000000 |
120,000 | 40.7 | -320° to 390° | 2 | NPT | Male | 30 | 390 | 20 15/16" | 10 11/16" | 4 1/16" | __ | __ | 4 | M12 | 1 3/16" | 0000000 | 00000000 |
ASME BPVC.VIII.1 Heat Exchangers | |||||||||||||||||
Copper-Brazed 316 Stainless Steel Plate | |||||||||||||||||
5,000 | 4.8 | -310° to 450° | 3/4 | NPT | Male | 27 | 435 | 8 7/16" | 3 3/16" | 4 7/16" | 2 | 9/32" | __ | __ | __ | 0000000 | 000000 |
12,000 | 7.9 | -310° to 450° | 1 | NPT | Male | 29 | 435 | 12 3/16" | 4 3/8" | 4 1/4" | 2 | 13/32" | __ | __ | __ | 0000000 | 000000 |
17,000 | 10.7 | -310° to 450° | 1 | NPT | Male | 37 | 435 | 12 3/16" | 4 3/8" | 5 1/4" | 2 | 13/32" | __ | __ | __ | 0000000 | 000000 |
50,000 | 15.6 | -310° to 450° | 1 | NPT | Male | 22 | 435 | 20 11/16" | 4 3/8" | 4 1/4" | 2 | 13/32" | __ | __ | __ | 0000000 | 000000 |
75,000 | 26.8 | -310° to 450° | 1 | NPT | Male | 34 | 435 | 20 11/16" | 4 3/8" | 6 3/16" | 2 | 13/32" | __ | __ | __ | 0000000 | 00000000 |
125,000 | 29.7 | -310° to 450° | 2 | NPT | Male | 57 | 435 | 24 5/16" | 7 1/2" | 5 3/4" | 2 | 1/2" | __ | __ | __ | 0000000 | 00000000 |
380,000 | 82.8 | -310° to 450° | 2 | NPT | Male | 141 | 435 | 24 5/16" | 7 1/2" | 11 1/2" | 2 | 1/2" | __ | __ | __ | 0000000 | 00000000 |
Heat Exchangers for Sampling
Surface
Area
Surface
Area
Often used to monitor boiler water quality without shutting down the system, these heat exchangers cool hot liquid samples to safe temperatures for testing. Sample liquid flows through the tubes, and cold water from an external water supply flows around the tubes to cool the liquid in the tubes. Cooled sample water then flows out of the heat exchanger for analysis.
316 stainless steel tubes have the best corrosion resistance.
Heat exchangers with 1.3 or 1.64 sq. ft. surface area are often used for sampling liquid from a boiler. Heat exchangers with 3.8 sq. ft. surface area are good for sampling steam from a boiler or for continuously cooling sample water.
For technical drawings and 3-D models, click on a part number.
Shell-Side | Tube-Side | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Surface Area, sq. ft. | Pipe Size | Thread Type | Gender | Flow Cap., gpm | Max. Pressure, psi | Max. Temp., °F | Pipe Size | Thread Type | Gender | Flow Cap., gpm | Max. Pressure, psi | Max. Temp., °F | Lg. | Head Dia. | Each | |
Steel Shell and 316 Stainless Steel Tube | ||||||||||||||||
1.3 | 1/4 | NPT | Female | 2 | 150 | 450° | 1/4 | NPT | Female | 4 | 1,200 | 750° | 17 1/4" | 3 1/2" | 0000000 | 0000000 |
3.8 | 3/8 | NPT | Female | 2 | 150 | 450° | 1/4 | NPT | Female | 4 | 4,900 | 750° | 32 5/8" | __ | 0000000 | 00000000 |