About Selecting Temperature Sensors
More
About Hazardous Location Environmental Ratings
More
Heat Detectors for Fire Alarm Systems


When the temperature climbs above the temperature rating, the detector sends a signal to your control panel.
Temperature Rating, °F | Dia. | Dp. | Tandem Signaling Capable | Electrical Connection | Number of Wire Leads | Voltage | Current | Specifications Met | Each | |
For Indoor Use | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
135° | 4 9/16" | 1 11/16" | No | Screw Terminals | __ | 12V DC 24V DC 120V AC | 1 A @ 12 V DC 1 A @ 24 V DC 3 A @ 120 V AC | FM Approved, UL Listed | 0000000 | 000000 |
194° | 4 9/16" | 1 11/16" | No | Screw Terminals | __ | 12V DC 24V DC 120V AC | 1 A @ 12 V DC 1 A @ 24 V DC 3 A @ 120 V AC | FM Approved, UL Listed | 0000000 | 00000 |
For Outdoor Use | ||||||||||
135° | 2" | 4 1/8" | No | Wire Leads | 4 | 12V DC 24V DC 120V AC | 1 A @ 12 V DC 1 A @ 24 V DC 5 A @ 120 V AC | FM Approved, UL Listed | 0000000 | 00000 |
194° | 2" | 4 1/8" | No | Wire Leads | 4 | 12V DC 24V DC 120V AC | 1 A @ 12 V DC 1 A @ 24 V DC 5 A @ 120 V AC | FM Approved, UL Listed | 0000000 | 00000 |
Smoke Detector Guards

Protect your detectors from damage and tampering.
Dia. | Dp. | Material | Color | Mount Type | Fasteners Included | Specifications Met | Each | |
8 1/4" | 2 3/4" | Polyester Coated Steel | White | Surface | Yes | UL Listed | 0000000 | 000000 |
Smoke Detector Testers

This spray smoke simulates fire conditions to make sure your detectors are working.
Extension arm and add-ons let you test out-of-reach smoke detectors. Up to five add-ons can be connected to the extension arm.
Fire Alarm Control Panels

Connect and monitor your fire alarm system. Control panel comes with all the circuitry needed to power and monitor devices for up to five zones. These devices can include up to 30 smoke or carbon monoxide detectors as well as an unlimited number of heat detectors and fire alarm stations. Indicators show the status of each zone. The control panel has one relay for connecting alarms such as buzzers, bells, and lights.
The control panel requires two 12-volt batteries (not included) for operation; in case of power failure, it will use the batteries as a backup power source.
For Max. Number of Zones | For Max. Number of Detectors | Ht. | Wd. | Dp. | Material | Color | Electrical Connection | Voltage | Batteries Included | Number of Batteries Required | Battery Size | Specifications Met | Each | |
5 | 30 | 19 1/2" | 14 1/4" | 3 3/4" | Steel | Red | Screw Terminals | 120V AC | No | 2 | 12V | UL Listed | 0000000 | 0000000 |
Fire Alarm Stations



Install these stations throughout your facility for quick access in case of a fire. When activated, they send a signal to your control panel.
Push-button station helps comply with ADA standards when properly installed.
Infrared Thermometers







Measure the temperature of dangerous, hard-to-reach, and moving surfaces without risking electrical shock or contamination. These thermometers are often used to locate and diagnose problems in electrical, heating, and ventilation systems. Maximum working distance is the distance a one foot target can be reliably measured.
Thermometers with adjustable emissivity can be calibrated for more accurate readings of shiny surfaces than thermometers with fixed emissivity.
Warning: These infrared thermometers are not intended for medical use. Use Non-Contact Forehead Thermometers for medical use.
Temperature Range | Resolution | Accuracy | Max. Working Distance, ft. | Emissivity | Response Time, sec. | Ht. | Wd. | Housing Material | Features | Specifications Met | Batteries Included | Each | ||
For Dark, Light, Shiny Surfaces | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Adjustable Emissivity | ||||||||||||||
A | -58° to 1200° F/-50° to 650° C | 0.1/0.1 | ±1% | 12 | 0.1 to 1 | 1 | 6 3/8" | 1 5/8" | Plastic | Automatic Shutoff, Laser Sight | CE Marked | Yes | 0000000 | 0000000 |
B | -58° to 1832° F/-50° to 1000° C | 0.1/0.1 | ±1% | 30 | 0.1 to 1 | 1 | 5 3/4" | 1 5/8" | Plastic | Automatic Shutoff, Laser Sight | CE Marked | Yes | 00000000 | 000000 |
C | -40° to 1022° F/-40° to 550° C | 0.1/0.1 | ±1% | 12 | 0.3 to 0.95 | 1 | 7" | 2" | Plastic | Automatic Shutoff, Laser Sight | CE Marked | Yes | 00000000 | 000000 |
D | -40° to 1202° F/-40° to 650° C | 0.1/0.1 | ±1% | 30 | 0.1 to 1 | 1 | 7" | 2" | Plastic | Automatic Shutoff, Laser Sight | CE Marked | Yes | 00000000 | 000000 |
D | -40° to 1472° F/-40° to 800° C | 0.1/0.1 | ±1% | 50 | 0.1 to 1 | 1 | 7" | 2" | Plastic | Automatic Shutoff, Laser Sight | CE Marked | Yes | 00000000 | 000000 |
E | -22° to 932° F/-30° to 500° C | 0.1/0.1 | ±1.5% | 10 | 0.1 to 1 | 1 | 6 7/8" | 3" | Plastic | Automatic Shutoff, Laser Sight | CE Marked | Yes | 0000000 | 000000 |
F | -4° to 1202° F/-20° to 650° C | 0.1/0.1 | ±1% | 12 | 0.1 to 1 | 1 | 7 7/16" | 2 3/16" | Plastic | Automatic Shutoff, Laser Sight, Waterproof | CE Marked | Yes | 00000000 | 000000 |
For Dark Surfaces | ||||||||||||||
Fixed Emissivity | ||||||||||||||
G | 0° to 750° F/-18° to 400° C | 0.1/0.1 | ±2% | 8 | 0.95 | 1 | 6" | 1 1/2" | Plastic | Automatic Shutoff, Laser Sight | CE Marked | Yes | 0000000 | 000000 |
Thermal Imaging Cameras

Detect hot spots, leaks, moisture problems, and construction defects invisible to the eye. These imaging guns translate thermal energy into a color image that indicates hotter areas as brighter and cooler areas as darker, so it’s easy to identify and diagnose problems on instrument panels, HVAC systems, and other equipment. To review footage at a later date, use them to take photos and videos. The lower a camera’s thermal sensitivity, the more precise heat differences it will detect for more detailed images. All are CE marked as meeting European standards for health, safety, and environmental protection. Some include a calibration certificate traceable to NIST stating they’ve passed a test for accuracy.

Temperature Range | Thermal Sensitivity (NETD) | Resolution | Accuracy | Emissivity | Ht. | Wd. | Screen Size | Housing Material | Specifications Met | Certification | Batteries Included | Each | ||
A | -4° to 752° F/-20° to 400° C | 60 mK | 160×120 | ±2% | 0.1 to 1 | 9 9/16" | 3 11/16" | 3 1/2" | Plastic | CE Marked | __ | Yes | 000000 | 000000000 |
A | -4° to 1200° F/-20° to 650° C | <40 mK | 320 x 240 | ±2% | 0.01 to 1 | 11" | 4 5/8" | 4" | Plastic | CE Marked | __ | Yes | 0000000 | 00000000 |
A | -4° to 1200° F/-20° to 650° C | <40 mK | 320 x 240 | ±2% | 0.01 to 1 | 11" | 4 5/8" | 4" | Plastic | CE Marked | Calibration Certificate Traceable to NIST | Yes | 00000000 | 00000000 |

Style C cameras connect wirelessly to your smart phone, displaying the thermal imaging on your phone’s screen.
Emissivity | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Thermal Sensitivity (NETD) | Resolution | Accuracy | For Dark Surfaces | For Dull Surfaces | For Light Surfaces | For Shiny Surfaces | Ht. | Wd. | Housing Material | Specifications Met | Batteries Included | Each | ||
Bluetooth C Connection | |||||||||||||||
C | -4° to 248° F/-20° to 120° C | 70 mK | 80 × 60 | ±5% | 0.95 | 0.8 | 0.6 | 0.3 | 5 7/8" | 1 1/2" | Rubber | CE Marked | Yes | 0000000 | 0000000 |
C | -4° to 752° F/-20° to 400° C | 70 mK | 160×120 | ±5% | 0.95 | 0.8 | 0.6 | 0.3 | 5 7/8" | 1 1/2" | Rubber | CE Marked | Yes | 0000000 | 000000 |
Pocket Infrared Thermometers with Calibration Certificate



To confirm the accuracy of noncontact temperature readings of dangerous and inaccessible surfaces, these thermometers come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy. Maximum working distance is the distance a one foot target can be reliably measured.
Thermometers with adjustable emissivity can be calibrated for more accurate readings of shiny surfaces than thermometers with fixed emissivity.
Warning: These infrared thermometers are not intended for medical use. Use Non-Contact Forehead Thermometers for medical use.
Temperature Range | Resolution | Accuracy | Max. Working Distance | Emissivity | Response Time, sec. | Ht. | Wd. | Housing Material | Specifications Met | Batteries Included | Each | ||
For Dark, Light, Shiny Surfaces | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Adjustable Emissivity | |||||||||||||
A | -67° to 482° F/-55° to 250° C | 0.1/0.1 | ±2° F/±1° C | 16" | 0.05 to 1 | 1 | 4" | 2" | Plastic | CE Marked | Yes | 0000000 | 000000 |
A | -30° to 430° F/-33° to 220° C | 0.5/0.2 | ±4° F/±2° C | 10" | 0.05 to 1 | 1 | 1 1/2" | 2 1/2" | Plastic | CE Marked | Yes | 0000000 | 00000 |
Fixed Emissivity | |||||||||||||
B | -27° to 428° F/-33° to 220° C | 0.1/0.1 | ±1.8° F/±1.0° C | 10" | 0.95 | 1 | 3 1/4" | 2 1/2" | Plastic | CE Marked | Yes | 0000000 | 00000 |
For Dark Surfaces | |||||||||||||
Fixed Emissivity | |||||||||||||
C | -7° to 230° F/-22° to 110° C | 0.1/0.1 | ±2.7° F/±1.5° C | 10" | 0.95 | 1 | 2 1/2" | 1 1/2" | Plastic | CE Marked | Yes | 0000000 | 00000 |
Infrared Thermometers with Calibration Certificate








Ensure the accuracy of noncontact temperature readings of dangerous and inaccessible surfaces with these thermometers that come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy. Maximum working distance is the distance a one foot target can be reliably measured.
Thermometers with adjustable emissivity can be calibrated for more accurate readings of shiny surfaces than thermometers with fixed emissivity.
Warning: These infrared thermometers are not intended for medical use.
Temperature Range | Resolution | Accuracy | Max. Working Distance, ft. | Emissivity | Response Time, sec. | Ht. | Wd. | Housing Material | Specifications Met | Batteries Included | Each | ||
For Dark Surfaces | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Fixed Emissivity | |||||||||||||
A | -76° to 932° F/-60° to 500° C | 0.1/0.1 | ±2% | 2 | 0.95 | 1 | 7" | 1 1/2" | Plastic | CE Marked | Yes | 0000000 | 0000000 |
B | -58° to 1832° F/-50° to 1000° C | 0.1/0.1 | ±1.5% | 50 | 0.95 | 1 | 9" | 2 1/4" | Plastic | CE Marked | Yes | 00000000 | 000000 |
For Dark, Light, Shiny Surfaces | |||||||||||||
Adjustable Emissivity | |||||||||||||
C | -58° to 1200° F/-50° to 650° C | 0.1/0.1 | ±1% | 12 | 0.1 to 1 | 1 | 6 3/8" | 1 5/8" | Plastic | CE Marked | Yes | 0000000 | 000000 |
D | -40° to 1202° F/-40° to 650° C | 0.1/0.1 | ±1% | 30 | 0.1 to 1 | 1 | 7" | 2" | Plastic | CE Marked | Yes | 00000000 | 000000 |
D | -40° to 1472° F/-40° to 800° C | 0.1/0.1 | ±1% | 50 | 0.1 to 1 | 1 | 7" | 2" | Plastic | CE Marked | Yes | 00000000 | 000000 |
E | -40° to 1022° F/-40° to 550° C | 0.1/0.1 | ±1% | 12 | 0.3 to 0.95 | 1 | 7" | 2" | Plastic | CE Marked | Yes | 00000000 | 000000 |
F | -4° to 1202° F/-20° to 650° C | 0.1/0.1 | ±1% | Not Rated | 0.1 to 1 | 0.5 | 7 3/8" | 2 3/16" | Plastic | CE Marked | Yes | 00000000 | 000000 |
G | -58° to 1832° F/-50° to 1000° C | 0.1/0.1 | ±1% | Not Rated | 0.1 to 1 | 0.5 | 5 11/16" | 1 11/16" | Plastic | CE Marked | Yes | 00000000 | 000000 |
H | -58° to 3992° F/-50° to 2200° C | 0.1/0.1 | ±1% | Not Rated | 0.1 to 1 | 0.1 | 8" | 2" | Plastic | CE Marked | Yes | 00000000 | 000000 |
Fixed Emissivity | |||||||||||||
B | -4° to 630° F/-20° to 330° C | 0.1/0.1 | ±2% | Not Rated | 0.95 | 0.5 | 6 1/4" | 1 9/16" | Plastic | CE Marked | Yes | 00000000 | 000000 |
Pocket Infrared Thermometers






Keep these small thermometers in your pocket or toolkit to spot check the temperature of dangerous, hard-to-reach, and moving surfaces without touching them. Maximum working distance is the distance a one foot target can be reliably measured.
Thermometers with adjustable emissivity can be calibrated for more accurate readings of shiny surfaces than thermometers with fixed emissivity.
Thermometers with laser sight have a red beam of light to indicate the precise area being measured.
Thermometers with Bluetooth wirelessly send temperature results to an app downloaded to your smartphone. Use the app to adjust the emissivity.
Warning: These infrared thermometers are not intended for medical use.
Temperature Range | Resolution | Accuracy | Max. Working Distance | Emissivity | Response Time, sec. | Ht. | Wd. | Features | Housing Material | Environmental Rating | Batteries Included | Each | ||
For Dark Surfaces | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Fixed Emissivity | ||||||||||||||
A | -27° to 482° F/-33° to 250° C | 0.1/0.1 | ±2% | Not Rated | 0.95 | 1 | 6" | 1/2" | Automatic Shutoff | Brass | __ | Yes | 0000000 | 000000 |
B | -27° to 932° F/-33° to 500° C | 0.1/0.1 | ±2% | 6" | 0.95 | 1 | 6" | 1" | Automatic Shutoff, Backlit Display, Laser Sight | Plastic | __ | Yes | 0000000 | 00000 |
C | -25° to 999° F/-32° to 535° C | 0.1/0.1 | ±5° F/±3° C | 2ft. | 0.95 | 1 | 8 1/16" | 2 7/16" | Automatic Shutoff, Laser Sight | Plastic | __ | Yes | 0000000 | 000000 |
C | -13° to 482° F/-25° to 250° C | 0.1/0.1 | ±2% | Not Rated | 95 | 1 | 3 1/8" | 1 1/4" | Min./Max. Memory | Plastic | IP65 | Yes | 0000000 | 00000 |
For Dark, Dull, Light, Shiny Surfaces | ||||||||||||||
Adjustable Emissivity | ||||||||||||||
F | -22° to 480° F/-30° to 250° C | 0.1/0.1 | ±2.7% | __ | 0.1 to 1 | 1 | 5 1/2" | 1 3/8" | Data Logging Capabilities, Laser Sight, Bluetooth, Min./Max. Memory | Plastic | __ | Yes | 0000000 | 000000 |
For Dark, Light, Shiny Surfaces | ||||||||||||||
Adjustable Emissivity | ||||||||||||||
D | -22° to 572° F/-30° to 300° C | 0.1/0.1 | ±2% | 6" | 0.2 to 0.99 | 0.5 | 4 1/2" | 1.7" | Automatic Shutoff, Laser Sight | Plastic | IP40 | Yes | 0000000 | 000000 |
E | 32° to 932° F/0° to 500° C | 1/1 | ±3.6° F/±2° C | 15ft. | 0.7 to 0.95 | 1 | 6 5/16" | 1 11/16" | Automatic Shutoff, Laser Sight | Plastic | IP67 | Yes | 0000000 | 000000 |
Infrared Thermometer Transmitters
Monitor the temperature of molten steel, furnaces, glass, and other hazardous surfaces without touching them. A built-in transmitter reads surface energy levels and converts them to analog and digital output values that can be read by a receiving device, such as a PLC. Because of this, you can use these transmitters for measuring and switching applications.
Adjust set points, emissivity range, and other settings on-site using the buttons on the transmitters. Connect transmitters to an IO-link controller (not included) to change settings remotely and alert you to errors on PLCs and human-machine interfaces.
Plug these transmitters into shielded M12 sockets since they're extremely prone to signal interference. These transmitters connect using two wires to send a 4-20mA current output and four wires to use the switching output and IO-link. Connect to pin 5 to utilize the test function to verify that the transmitter's signal processing is working correctly. To view transmitter wiring diagrams, select a part number and click Product Detail.
Their lenses resist scratches, which could cause transmitters to lose focus. All are IP-rated for protection against dust and low-pressure jets of water. Made of 303 stainless steel, these transmitters resist corrosion.
Transmitters can be used on all surfaces. For best results when measuring at an angle or working on round or uneven surfaces, use transmitters with laser sight.
Transmitters with a wavelength range of 0.78–1.06 microns are best for use with glass. Use transmitters with a wavelength range of 1–1.7 microns on metal, ceramics, and graphite. Transmitters with a wavelength range of 8–14 microns are useful for plastic, fabrics, food products, and other metal-free surfaces.
Add accessories to protect your infrared thermometer transmitter in hot or dirty environments. Air purges flush out dust, moisture, and other contaminants on transmitter lenses that can interfere with infrared radiation focus and cause inaccurate readings. Cooling jackets connect to a compressed air or water line to keep temperature transmitters from overheating. Protective covers prevent dirt buildup and excessive exposure to light, which can cause transmitters to lose focus. Insulating tubes prevent overheating by protecting thermometers against heat from mounting brackets or other surfaces.
For technical drawings and 3-D models, click on a part number.



Transmitters | Mounting Brackets | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wavelength Range, microns | Temperature Range | Resolution | Accuracy | Digital Display Type | Emissivity | Response Time, sec. | Length | Diameter | Housing Material | Output Type | Each | Each | ||
Bracket Mount with Scratch-Resistant Lens | ||||||||||||||
0.78 - 1.06 | 932° to 4532° F/500° to 2500° C | 1° F/1° C | ±0.3% | LED | 0.1 to 1.1 | 0.002 | 8 7/16" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 00000000 | 000000000 | 00000000 | 000000 |
1 - 1.7 | 482° to 2912° F/250° to 1600° C | 1° F/1° C | ±0.5% | LED | 0.1 to 1.1 | 0.002 | 8 7/16" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 00000000 | 00000000 | 00000000 | 00000 |
8 - 14 | 32° to 1831° F/0° to 1000° C | 1° F/0.5° C | ±1% | LED | 0.1 to 1.1 | 0.1 | 7 1/2" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 00000000 | 00000000 | 00000000 | 00000 |
Bracket Mount with Scratch-Resistant Lens and Laser Sight | ||||||||||||||
1 - 1.7 | 482° to 2912° F/250° to 1600° C | 1° F/1° C | ±0.5% | LED | 0.1 to 1.1 | 0.002 | 9 7/16" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 00000000 | 00000000 | 00000000 | 00000 |
8 - 14 | 32° to 1831° F/0° to 1000° C | 1° F/0.5° C | ±1% | LED | 0.1 to 1.1 | 0.1 | 8 1/8" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 00000000 | 00000000 | 00000000 | 00000 |
Hazardous Location Infrared Thermometers

These thermometers are rated for environments where hazardous material is present. They measure the temperature of surfaces without making contact and are often used to locate and diagnose problems in electrical, heating, and ventilation systems. Maximum working distance is the distance a one foot target can be reliably measured.
Thermometers with adjustable emissivity can be calibrated for more accurate readings of shiny surfaces than thermometers with fixed emissivity.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment. See About Hazardous Location Environmental Ratings.
Warning: These infrared thermometers are not intended for medical use. Use Non-Contact Forehead Thermometers for medical use.
Batteries | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Resolution | Accuracy | Max. Working Distance, ft. | Emissivity | Response Time, sec. | Ht. | Wd. | Housing Material | Environmental Rating | Included | Size | No. Required | Each | |
For Dark, Dull Surfaces | ||||||||||||||
Fixed Emissivity | ||||||||||||||
0° to 752° F/-18° to 400° C | 0.2/0.2 | ±2% | 8 | 0.95 | 0.5 | 6" | 1 1/2" | Plastic | IEC Zone 1 Groups IIC, IIB, IIA | Yes | 9V | 1 | 0000000 | 0000000 |
For Dark, Dull, Light, Shiny Surfaces | ||||||||||||||
Adjustable Emissivity | ||||||||||||||
-40° to 1472° F/-40° to 800° C | 0.1/0.1 | ±1% | 30 | 0.1 to 1 | 0.5 | 7" | 2" | Plastic | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Zone 1 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA | Yes | AAA | 2 | 0000000 | 00000000 |
Noncontact Infrared Temperature Sensors
Monitor the temperature of hazardous, sensitive, and hard-to-reach surfaces without touching them. IP or NEMA rated, these sensors are protected against dust and washdowns.
Sensors for nonmetal surfaces measure the temperature of plastics, fabrics, ceramics, and hot adhesives.
Sensors for metal surfaces measure the temperature of both solid metals, such as heating elements, and molten metals.
Sensors with a thermocouple output communicate with devices that read thermocouple signals, so they work as replacements for thermocouples with the same output type.
Sensors with a micro USB cord and terminal block connect to your computer. Use the downloadable software to change the measurement temperature range and the output scale.
Secure your sensor with a mounting bracket or mounting stud. Mounting brackets attach to flat surfaces. Mounting studs thread into holes.
Air purges flush dust, moisture, and other contaminants from the sensor lens to prevent inaccurate readings.
For technical drawings and 3-D models, click on a part number.

Sensor | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Measuring Range, °F | Min. Object Size Detected | Max. Sensing Distance | Wavelength, microns | Resolution | Accuracy | Response Time, sec. | Lg. | Dia. | Cable Lg., ft. | Input Voltage | For Panel Cutout Dia. | Thread Size | Includes | Environmental Rating | Each | |
0-5V DC, 0-10V DC, Thermocouple Type K Output Signal | ||||||||||||||||
Adjustable Emissivity (0.1-1.1) | ||||||||||||||||
-40° to 1,886° | 0.24" | 2.6ft. | 8-14 | 15:1 | ±3° F below 200° F ±1.5% above 200° F | 0.025 | 3 1/2" | 1/2" | 3.25 | 5V DC-30V DC | 1/2" | M12 | 3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters) | IP65 | 0000000 | 0000000 |
4-20 mA Output Signal | ||||||||||||||||
Adjustable Emissivity (0.1-1.1) | ||||||||||||||||
-58° to 1,886° | 0.26" | 3.2ft. | 8-14 | 15:1 | ±2° F below 200° F ±1% above 200° F | 0.014 | 1 1/8" | 1/2" | 3.25 | 5V DC-30V DC | 1/2" | M12 | 3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters) | IP65, NEMA 4 | 0000000 | 000000 |

Sensor | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Measuring Range, °F | Min. Object Size Detected | Max. Sensing Distance | Wavelength, microns | Resolution | Accuracy | Response Time, sec. | Lg. | Dia. | Cable Lg., ft. | Input Voltage | For Panel Cutout Dia. | Thread Size | Includes | Environmental Rating | Each | |
4-20 mA Output Signal | ||||||||||||||||
Adjustable Emissivity (0.1-1.1) | ||||||||||||||||
122° to 662° | 0.26" | 3.6ft. | 2.3 | 22:1 | ±(0.3% of Temperature Measured + 3.6° F) | 0.02 | 1 1/4" | 1/2" | 3.25 | 5V DC-30V DC | 1/2" | M12 | 3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters) | IP65, NEMA 4 | 0000000 | 0000000 |

For Sensor Dia. | Ht. | Wd. | Dp. | Material | Mounting Fasteners Included | Each | |
1/2" | 1 1/8" | 3/4" | 7/8" | 304 Stainless Steel | Yes | 0000000 | 000000 |

Thread | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Sensor Dia. | Size | Pitch, mm | Lg. | Ht. | Wd. | Dp. | Material | Each | |
1/2" | M12 | 1 | 1/4" | 7/8" | 3/4" | 1/2" | 303 Stainless Steel | 0000000 | 000000 |

For Sensor Connection Thread | ||||
---|---|---|---|---|
Size | Pitch | Material | Each | |
M12 | 1 mm | 303 Stainless Steel | 0000000 | 000000 |
Heat Stress Monitors
Measure temperature, humidity, and radiant heat in your work area to keep your team safe from heat-related hazards. These monitors help you avoid dangerous conditions and comply with OSHA standards for a safe work environment. They use a variety of measurements from your surroundings to calculate the heat stress index and the wet bulb globe temperature (WBGT), which tell you how hot it feels. Set a maximum wet bulb globe temperature, and an alarm will go off when heat reaches the safety limit.
These monitors have two sensors. One measures temperature, humidity, dew point, and wet globe temperature. The other measures black globe temperature, which is the effect of direct solar radiation on an exposed surface. Carry monitors with you to measure different areas, or mount to your tripod to measure conditions over time.
To maintain their accuracy, monitors should be calibrated once a year. You can calibrate the monitor yourself using humidity standards. These standards contain a known humidity, so you can adjust your monitor until it reads the humidity correctly.
Monitors that come with a calibration certificate traceable to NIST have passed a test for accuracy.
Power these monitors with the included batteries, or add a power adapter to plug them in.
Add a memory card to store your readings and export them to a computer.
Import regulations restrict sales to the listed areas.


Heat Stress
Monitor
Air Temp. | Black Globe Temp. | Wet Bulb Globe Temp. | Barometric Pressure | Relative Humidity | Mounting | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Range, °F | Accuracy, °F | Range, °F | Accuracy, °F | Range, °F | Accuracy, °F | Range | Accuracy | Range | Accuracy | Fasteners Included | No. of Holes | Hole Thread Size | Data Connection Type | Cannot Be Sold To | Each | |
Heat Stress Monitors | ||||||||||||||||
Monitors | ||||||||||||||||
32° to 122° | ±1.1° | 32° to 176° | ±1.8° | 59° to 132° | ±3.6° | 8.9in. of Hg to 32.5in. of Hg | ±0.044" Hg | 0% to 100% | ±5% | No | 1 | 1/4"-20 | __ | Canada | 0000000 | 0000000 |
Monitors With NIST Certificate | ||||||||||||||||
32° to 122° | ±1.1° | 32° to 176° | ±1.8° | 59° to 132° | ±3.6° | 8.9in. of Hg to 32.5in. of Hg | ±0.044" Hg | 0% to 100% | ±5% | No | 1 | 1/4"-20 | __ | Canada | 0000000 | 000000 |
Data Logging Heat Stress Monitors | ||||||||||||||||
Monitors | ||||||||||||||||
32° to 122° | ±1.5° | 32° to 176° | ±1.1° | 32° to 132° | ±3.6° | __ | __ | 5% to 95% | ±3% | No | 1 | 1/4"-20 | Standard SD Card | Canada | 0000000 | 000000 |
Monitors With NIST Certificate | ||||||||||||||||
32° to 122° | ±1.5° | 32° to 176° | ±1.1° | 32° to 132° | ±3.6° | __ | __ | 5% to 95% | ±3% | No | 1 | 1/4"-20 | Standard SD Card | Canada | 0000000 | 000000 |

Relative Humidity | Relative Humidity Accuracy | Each | |
33%, 75% | ±1% | 0000000 | 0000000 |

Inside | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Height | Width | Depth | Height | Width | Depth | Weight, lbs. | Color | Material | Lock Type | Foam Type | Each | |
5 3/4" | 13" | 12" | 5 1/2" | 12" | 9 1/2" | 4 1/2 | Black | Plastic | Padlockable | Cubed | 0000000 | 000000 |

Memory Card Type | Capacity | Includes | Each | |
Standard SD, microSDHC | 16GB | Adapter | 0000000 | 000000 |
Night-Vision Monoculars

View clear and crisp images in dimly lit or completely dark areas. These aren’t the blurry, green night-vision goggles you see in movies—they have a built-in infrared illuminator that amplifies available light for a clear image. Rather than adjusting a lens, just press a button to zoom in on faraway objects. This also lets you operate the device using only one hand. Their built-in camera captures images and records videos. Upload your recordings to your PC from the included microSD card.
Batteries | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Magnification | Lens Dia., mm | Field of View | Resolution | Lg. | Wd. | Included | Size | No. Required | Container Type | Each | |
2X, 4X | 20 | 10° | 640 × 480 | 5" | 2 1/2" | No | AAA | 3 | Pouch | 0000000 | 0000000 |
Motion-Sensing Modules for Development Boards
By detecting body heat, these modules sense when people are moving. Connect them to your development board to integrate them into alarm systems, automated lighting, and other applications.
Modules with a fixed infrared motion and thermal sensor can detect if a person is moving or even just present within the sensing distance. That means you could use them to automate lighting in an office where workers are sitting still. To connect them to your device, solder on wires or headers. For a solderless connection, use a Qwiic cord.

Output Data | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Sensing Distance | Field of View | Accuracy | Resolution, bit | Frequency, Hz | Input Voltage | I2C Address | No. of Qwiic Connections | Lg. | Wd. | Each | |
I2C Communication Protocol—Qwiic Connection | |||||||||||
4 m | 80° | ±0.3° C | 16 | 30 | 1.7-3.6V DC | 0x5A | 2 | 1" | 1" | 0000000 | 000000 |