About Brightness
More
About Light Appearance
More
Hazardous Location Ceiling Lights


These lights are UL listed or CSA certified for hazardous locations where flammable/combustible gases, vapors, and liquids may be present. They have a sealed lens and can be hardwired to operate on any of the voltages listed.
Styles 1-2 can be used where hazardous material occurs infrequently. They have built-in LEDs that last longer, are more efficient, and generate less heat than other light technologies. Style 1 are housed in durable stainless steel. Style 2 have an acrylic lens that won’t turn yellow over time.
Lights with a cool appearance highlight white/blue tones that are good for inspecting.
All are IP66 rated for protection from washdowns. IP67 rated lights can be briefly submerged. NEMA 4X rated lights protect their parts from corrosion.

Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Lg. | Wd. | Ht. | Voltage | Light Appearance | Wattage | Housing Material | For Conduit Trade Size | Thread Type | Mounting Hardware Included | Environmental Rating | Specifications Met | Each | |
Fastener Mount | ||||||||||||||
1 | 24" | 4 3/4" | 7 1/4" | 120V AC, 208V AC, 240V AC, 277V AC | Cool (4,100K) | 27W | Stainless Steel | 3/4 | NPT | No | NEC Class I Division 2 Groups A, B, C, D; NEC Zone 2 Groups IIC, IIB, IIA; IP66; NEMA 4X; NEC Class II Division 2 Groups F, G | UL Listed, C-UL Listed, UL Marine Listed | 0000000 | 000000000 |

Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Lg. | Wd. | Ht. | Voltage | Light Appearance | Wattage | Housing Material | For Conduit Trade Size | Mounting Hardware Included | Environmental Rating | Specifications Met | Each | |
Fastener Mount | |||||||||||||
2 | 51 3/4" | 6 7/8" | 4 3/8" | 120V AC, 208V AC, 240V AC, 277V AC | Neutral (4,000K) | 54W | Fiberglass | 1/2 | No | NEC Class I Division 2 Groups A, B, C, D; NEC Zone 2 Groups IIC, IIB, IIA; IP66; IP67 | CSA Certified, CSA-US Certified | 0000000 | 000000000 |
Hazardous Location Ceiling and Wall Lights with Guard










Also known as jelly jar lights. These fixtures have a heat-resistant lens and a guard that protects the lens from breaking. They are CSA certified for hazardous locations where flammable/combustible gases, vapors, and liquids may be present. They are rated NEMA 4X for protection against corrosion and washdowns. Lights are sealed to keep moisture out. They can be hardwired to operate on any of the voltages listed. Some work with LED or incandescent bulbs (sold separately).
Styles 1, 2, 3, 5, and 6 can be used in environments where ignitable concentrations of flammable/combustible gases, vapors, and liquids or combustible dust occur infrequently, such as in the case of an accidental spill or failure of a ventilation system, and where combustible/ignitable fibers or flyings are present under normal operating conditions and/or during frequent equipment maintenance or failure. Rated for Class I, Division 2, Groups A, B, C, and D; Class II, Division 2, Groups F and G; and Class III, Divisions 1 and 2, these lights withstand acetylene, hydrogen, ethylene, propane, carbonaceous dusts, and nonconductive dusts.
Styles 4 and 7 can be used in environments where ignitable concentrations of hazardous material are present under normal operating conditions, and/or during frequent equipment maintenance or failure. Rated for Class I, Divisions 1 and 2, Groups C and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2, these lights withstand ethylene, propane, conductive or metal dusts, carbonaceous dusts, nonconductive dusts, and combustible/ignitable fibers or flyings.
O'all | Mounting Holes | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Dia. | Ht. | Dp. | Voltage | Bulbs Included | No. of Bulbs Required | Screw-In Base Size | Wattage | Max. Wattage per Bulb | Housing Material | For Conduit Trade Size | Thread Type | Mounting Hardware Included | No. of | Dia. | Specifications Met | Each | |
Built-In LED Bulbs | ||||||||||||||||||
Ceiling Thread On | ||||||||||||||||||
1 | 4 1/2" | 8 1/2" | __ | 120V AC, 277V AC | Built-In LED | __ | __ | 15W | __ | Polyester Plastic | 3/4 | NPT | No | __ | __ | CSA Certified, CSA-US Certified | 0000000 | 0000000 |
2 | 4 1/2" | 8 1/8" | __ | 120V AC, 277V AC | Built-In LED | __ | __ | 15W | __ | Polyester Plastic | 3/4 | NPT | No | 2 | 5/16" | CSA Certified, CSA-US Certified | 0000000 | 000000 |
Wall Thread On | ||||||||||||||||||
3 | 4 1/2" | 9 1/2" | 7 3/8" | 120V AC, 277V AC | Built-In LED | __ | __ | 15W | __ | Polyester Plastic | 3/4 | NPT | No | 2 | 5/16" | CSA Certified, CSA-US Certified | 0000000 | 000000 |
For Incandescent Bulbs | ||||||||||||||||||
Ceiling Fastener Mount | ||||||||||||||||||
2 | 4 3/4" | 10 7/8" | __ | 120V AC, 277V AC | No | 1 | Medium (Standard Household) | __ | 150W | Fiberglass | 3/4 | NPT | No | 2 | 5/16" | CSA Certified, CSA-US Certified | 00000000 | 000000 |
4 | 7 1/2" | 14 3/8" | __ | 120V AC, 208V AC, 240V AC | No | 1 | Medium (Standard Household) | __ | 150W | Aluminum | 3/4 | NPT | No | 4 | 5/16" | CSA Certified, MS16555-650, MS9321-9 | 0000000 | 000000 |
Ceiling Thread On | ||||||||||||||||||
5 | 4 1/2" | 11 1/4" | __ | 120V AC, 277V AC | No | 1 | Medium (Standard Household) | __ | 150W | Fiberglass | 3/4 | NPT | No | __ | __ | CSA Certified, CSA-US Certified | 00000000 | 000000 |
Wall Fastener Mount | ||||||||||||||||||
6 | 4 1/2" | 12 1/4" | 7 1/4" | 120V AC, 277V AC | No | 1 | Medium (Standard Household) | __ | 150W | Fiberglass | 3/4 | NPT | No | 2 | 5/16" | CSA Certified, CSA-US Certified | 00000000 | 000000 |
7 | 7 1/2" | 15 7/8" | 14 1/2" | 120V AC, 208V AC, 240V AC | No | 1 | Medium (Standard Household) | __ | 150W | Aluminum | 3/4 | NPT | No | 2 | 1/4" | CSA Certified, MS16555-650, MS9321-9 | 0000000 | 00000000 |
Hazardous Location Bay Lights

Use these lights in large, open areas such as warehouses and manufacturing spaces where the ceiling is up to 30-ft. high. They are ETL and C-ETL listed for Class I Division 2 Groups A, B, C, and D, Class II Divisions 1 and 2, Groups E, F, and G, and Class III Divisions 1 and 2 for use in environments where ignitable concentrations of acetylene, hydrogen, ethylene, and propane occur infrequently, such as in the case of an accidental spill or failure of a ventilation system. With built-in LEDs, these lights last longer, are more efficient, and generate less heat than other light technologies. They produce a neutral light appearance, which creates a balanced environment for general work areas. These lights produce a wide beam of uniform light. Lights can be hardwired to operate on any of the voltages listed. Thread onto 3/4 NPT conduit to suspend lights from the ceiling.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Bay Light Type | Lg. | Wd. | Ht. | Equiv. Metal Halide Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | For Conduit Trade Size | Thread Type | Gender | Mounting Hardware Included | Each | |
Built-In LED Bulbs | ||||||||||||||
High | 12 5/8" | 9 1/2" | 10 3/8" | 400W | 120V AC, 208V AC, 240V AC, 277V AC | 11,200 | Neutral (4,000K) | 80W | 3/4 | NPT | Female | No | 0000000 | 0000000 |
Hazardous Location Recessed Wall Lights

Mount lights in recessed spaces so the lens is flush with the wall. These fixtures are ETL and C-ETL listed for Class I, Division 2, Groups A, B, C, and D; and Class II, Division 2, Groups F and G for use where ignitable concentrations of hazardous material occur infrequently, such as in the case of an accidental spill or failure of a ventilation system. They withstand acetylene, hydrogen, ethylene, propane, carbonaceous dusts, and nonconductive dusts. These lights are often used in freestanding buildings, such as paint spray booths, so the back opens like a door for changing light bulbs from the outside. They can be hardwired to operate on any of the voltages listed. They work with tubular fluorescent bulbs (sold separately).
Lights | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mounting Holes | Bulbs | ||||||||||||||
Lg. | Wd. | Ht. | Voltage | Bulbs Included | No. of Bulbs Required | Max. Wattage per Bulb | Housing Material | Mounting Hardware Included | No. of | Dia. | Specifications Met | Each | Pkg. Qty. | Pkg. | ||
For Tubular T8 Fluorescent Bulbs | ||||||||||||||||
53 1/4" | 21 3/4" | 5 3/4" | 120V AC, 277V AC | No | 4 | 32W | Steel | Yes | 12 | 5/16" | ETL Listed, C-ETL Listed | 00000000 | 0000000 | 6 | 0000000 | 000000 |
Hazardous Location Large-Area Floodlights

These lights are UL listed for Class I, Division 2, Groups A, B, C, and D for environments where ignitable concentrations of acetylene, hydrogen, ethylene, and propane occur infrequently, such as in the case of an accidental spill or failure of a ventilation system. They can be hardwired to operate on any of the voltages listed. They require a metal halide bulb (sold separately). These floodlights cannot be sold to California due to local energy efficiency regulations.
Lights | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Bulbs | ||||||||||||||
Voltage | Bulbs Included | No. of Bulbs Required | Max. Wattage per Bulb | Wd. | Ht. | Dp. | For Conduit Trade Size | Thread Type | Gender | Mounting Hardware Included | Cannot Be Sold To | Each | Each | ||
For Blown Tubular BT37 Metal Halide Bulbs | |||||||||||||||
120V AC, 208V AC, 240V AC, 277V AC | No | 1 | 400W | 17 1/4" | 16 1/4" | 7 5/8" | 1/2 | NPT | Female | Yes | CA | 0000000 | 0000000 | 0000000 | 000000 |