About Motor Switches and Starters
More
Choosing an Electrical Switch
More
Push-Button Hazardous Location Enclosures
UL and C-UL classified, these enclosures safely house push-button controls and electronics where there’s explosive dust and gas. They have holes already drilled to standard button sizes and conduit connections that let you route wire through the enclosure, saving you effort and time. NEMA rated, they also protect what’s inside from dust, rain, and spraying water.
For technical drawings and 3-D models, click on a part number.
Inside | Connection | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Columns | Number of Rows | Height | Width | Depth | Height | Width | Depth | Environment | Thread Type | Pipe Size | Features | Specifications Met | Color | Each | |
Aluminum with Lift-Off Cover and Screw Closure | |||||||||||||||
For 19 mm Push Button | |||||||||||||||
1 | 1 | 4 1/2" | 4 1/2" | 4 3/8" | 3" | 3" | 3 7/8" | Corrosive, Damp, Dusty, Hazardous Location, Outdoor, Washdown | NPT | 3/4 | Grounding Stud; Mounting Feet | UL Classified, C-UL Classified | Gray | 0000000 | 0000000 |
1 | 2 | 7 1/16" | 4 1/2" | 4 3/16" | 6" | 3" | 3 3/4" | Corrosive, Damp, Dusty, Hazardous Location, Outdoor, Washdown | NPT | 3/4 | Grounding Stud; Mounting Feet | UL Classified, C-UL Classified | Gray | 0000000 | 000000 |
1 | 3 | 8 1/8" | 4 1/2" | 4 3/16" | 7" | 3" | 3 11/16" | Corrosive, Damp, Dusty, Hazardous Location, Outdoor, Washdown | NPT | 3/4 | Grounding Stud; Mounting Feet | UL Classified, C-UL Classified | Gray | 0000000 | 000000 |
1 | 4 | 10 1/16" | 4 1/2" | 4 1/4" | 9" | 3" | 3 3/4" | Corrosive, Damp, Dusty, Hazardous Location, Outdoor, Washdown | NPT | 1 | Grounding Stud; Mounting Feet | UL Classified, C-UL Classified | Gray | 0000000 | 000000 |
1 | 5 | 12 1/16" | 4 1/2" | 4 1/4" | 11" | 3" | 3 3/4" | Corrosive, Damp, Dusty, Hazardous Location, Outdoor, Washdown | NPT | 1 1/4 | Grounding Stud; Mounting Feet | UL Classified, C-UL Classified | Gray | 0000000 | 000000 |
1 | 6 | 14 1/16" | 4 1/2" | 4 1/8" | 13" | 3" | 3 5/8" | Corrosive, Damp, Dusty, Hazardous Location, Outdoor, Washdown | NPT | 1 1/4 | Grounding Stud; Mounting Feet | UL Classified, C-UL Classified | Gray | 0000000 | 000000 |
1 | 7 | 16" | 4 1/2" | 4 1/8" | 15" | 3" | 3 5/8" | Corrosive, Damp, Dusty, Hazardous Location, Outdoor, Washdown | NPT | 1 1/4 | Grounding Stud; Mounting Feet | UL Classified, C-UL Classified | Gray | 0000000 | 000000 |
Hazardous Location Enclosures
For use in hazardous locations, these enclosures are rated NEMA 7 and 9 and meet UL Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2. They are also rated NEMA 4 for protection from dirt and washdowns.
Panels are for mounting components inside enclosures.
For technical drawings and 3-D models, click on a part number.
Enclosures | Panels | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Dp. | Wall Thick. | Environment | Environmental Rating | Specifications Met | Each | Each | ||
Aluminum with Lift-Off Cover and Screw Closure | ||||||||||
10 1/4" | 10 1/4" | 6" | 1/2" | Hazardous Location, Washdown | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IP66 NEMA 4 NEMA 7 NEMA 9 | UL Listed, UL 698, UL 886, UL 1203, CSA Certified | 0000000 | 000000000 | 0000000 | 0000000 |
12 1/4" | 12 1/4" | 8" | 1/2" | Hazardous Location, Washdown | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IP66 NEMA 4 NEMA 7 NEMA 9 | UL Listed, UL 698, UL 886, UL 1203, CSA Certified | 0000000 | 00000000 | 0000000 | 000000 |
12 1/4" | 14 1/4" | 8 1/4" | 1/2" | Hazardous Location, Washdown | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IP66 NEMA 4 NEMA 7 NEMA 9 | UL Listed, UL 698, UL 886, UL 1203, CSA Certified | 0000000 | 00000000 | 0000000 | 000000 |
Aluminum with Hinged Cover and Screw Closure | ||||||||||
16 1/2" | 16 1/2" | 8 3/4" | 3/4" | Hazardous Location, Washdown | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IP66 NEMA 4 NEMA 7 NEMA 9 | UL Listed, UL 698, UL 886, UL 1203, CSA Certified | 0000000 | 00000000 | 0000000 | 000000 |
16 1/2" | 16 1/2" | 10 3/4" | 3/4" | Hazardous Location, Washdown | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IP66 NEMA 4 NEMA 7 NEMA 9 | UL Listed, UL 698, UL 886, UL 1203, CSA Certified | 0000000 | 00000000 | 0000000 | 000000 |
Hazardous Location Enclosed Disconnect Switches
With a housing that’s designed to contain an explosion, these switches are safe to use in areas where ignitable concentrations of flammable or combustible gas, dust, or fibers may be present. They meet NEC Class I Div. 1 and 2, Groups B, C, D, and Class II, Div. 1 and 2, Groups E, F, and G. Use them to cut power and keep it isolated, so equipment won’t accidentally start up during inspection or maintenance.
Made from aluminum, these switches also resist corrosion in wet or oily areas. They have a lockout, so you can secure them in the off position with a padlock (not included).
For technical drawings and 3-D models, click on a part number.
Switching | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Switch Action | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Environmental Rating | Each | ||
Powder-Coated Aluminum Housing with Red Actuator | ||||||||||
3 Circuits with Lockout | ||||||||||
A | 30 | 600V AC | Stays Switched (Maintained) | 3PST | Three (30 hp @ 600 V AC) | 8 1/16" | 5 3/4" | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Zone 1 Groups IIB, IIA NEMA 4X NEMA 7 NEMA 9 | 0000000 | 000000000 |
Powder-Coated Aluminum Housing with Yellow Actuator | ||||||||||
3 Circuits with Lockout | ||||||||||
B | 60 | 600V AC | Stays Switched (Maintained) | 3PST | Three (40 hp @ 600 V AC) | 13 1/16" | 8 1/8" | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Zone 1 Groups IIB, IIA NEMA 4X NEMA 7 NEMA 9 | 0000000 | 00000000 |
B | 100 | 600V AC | Stays Switched (Maintained) | 3PST | Three (50 hp @ 600 V AC) | 13 1/16" | 8 1/8" | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Zone 1 Groups IIB, IIA NEMA 4X NEMA 7 NEMA 9 | 0000000 | 00000000 |
Hazardous Location Enclosed Motor Switches
Safely turn motors on and off near ignitable gases and dust—the housing on these switches seals in anything that could ignite flammable material. Made from aluminum, the housing is lightweight and durable. It guards against water, oil, and other materials that could cause damage. Even in harsh conditions, there’s no need to mount these switches inside an electrical panel.
You need to grip and twist the lever to actuate these switches, so they won’t accidentally turn on or off if something bumps into them. In addition to starting and stopping motors, they work with other circuits, such as lighting and electric heat circuits. They don’t provide overload protection.
For technical drawings and 3-D models, click on a part number.
Switching | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Electrical Phase (hp) | Switch Starting Position | Industry Designation | Current, A | Voltage | Ht. | Wd. | Wire Connection Type | Environmental Rating | Specifications Met | Each | |
Stays Switched (Maintained) | ||||||||||||
2 | Single (3 hp @ 240 V AC) | 2 Off (Normally Open) | DPST-NO | 30 | 600V AC | 6.5" | 3" | Screw Terminals | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 NEMA 9 | UL Listed, C-UL Listed, CSA Certified | 0000000 | 0000000 |
3 | Three (7 1/2 hp @ 240 V AC) | 3 Off (Normally Open) | 3PST-NO | 30 | 600V AC | 6.5" | 3" | Screw Terminals | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 NEMA 9 | UL Listed, C-UL Listed, CSA Certified | 0000000 | 000000 |